SDR 98UAL900285Girt Bar · out of adjustDOOR 3R WOULD NOT ARM. *S/D* SLIDE ARMED LIGHT DID NOT COME ON WHEN SLIDE ARMED. FOUND GIRT BAR OUT OF SEQUENCE. READJUSTED GIRT BAR. OPS CHECKS NORMAL.SDR 98UAL900263Smoke Detector · failedLANDED SFO UNDER AMBER ALERT DUE TO OVERHEAT LIGHT AND SMOKE INDICATION IN FORWARD EQUIPMENT BAY. *S/D* AIRCRAFT EXPERIENCED A SMOKE INDICATION. MAINTENANCE REPLACED BOTH EQUIPMENT COOLING SMOKE DETECTORS. REPLACED RELAY K10506 ALTERNATE MODE RELAY.SDR 98UAL900259Oven · dirtyFOOD WRAPPER IN FORWARD OVEN CAUGHT FIRE. HALON EXTINGUISHER USED TO PUT FIRE OUT. *S/D* FOOD WRAPPER WAS NOT PROPERLY INSTALLED. REMOVED WRAPPER, CLEANED OVEN, OPS NORMAL.SDR 98UAL900260Actuator · brokenRETURNED TO DEN DUE TO LOSS OF LEFT HYDRAULIC SYSTEM. NORMAL LANDING. *S/D* LEFT MLG TRUCK POSITION ACTUATOR BLEED PLUG CAME LOOSE, CAUSING FLUID LOSS. ACTUATOR REPLACED. AIRCRAFT TO BE TESTED FOR PROPER FUSE OPERATION.SDR 98UAL900248Wire · brokenRETURNED TO FIELD DUE TO PARTIAL ELECTICAL FAILURE. WIRE W2018-0003-06 WAS FOUND BROKEN AT L GENERATOR CIRCUIT BREAKER C901 PHASE C. LOSS OF PHASE C AT L GEN CB CAUSED PARTIAL ELECTRICAL FAILURE. THE WIRE TERMINAL HAD BROKEN DUE TO A ONE-TIME OVERSTRESS APPSDR DL757981177Oil Line · crackedTHE MAIN OIL BEARING MANIFOLD SCAVENGE LINE CRACKED AT AN ELBOW WHERE IT GOES INTO THE TOWER SHAFT, MFG NR 1A821101. REPLACED LINE.SDR 98UAL900228Pressurization · malfunctionedCABIN ALTITUDE AUTO 1 AND 2 STATUS MESSAGES, AND AUTO INOP LIGHT ON OVERHEAD ILLUMINATED. UNSCHEDULED LANDING WAS MADE INTO DEN.SDR 98UAL900224Engine · failedLANDED DEN UNDER AMBER ALERT WITH NR 1 ENGINE SHUTDOWN DUE TO LOSS OF OIL PRESSURE.SDR 98UAL900225Valve · failedDIVERTED TO SFO DUE TO A BLEED VALVE PROBLEM. *S/D* LEFT ENGINE BLEED SYSTEM WAS CLOSING OFF DUE TO TEMPERATURE. LEFT ENGINE FAN AIR MODULATING VALVE TEMPERATURE SENSOR AND LEFT ENGINE AIR BLEED OVERTEMP SENSOR REPLACED. NO PNEUMATIC WRITE-UPS SINCE DIVERSSDR 98UAL900218Battery Pack · dischargedEMERGENCY FLOOR LIGHTS INOP ROW 9 TO ROW 16. BATTERY NOT SECURE IN POWER SUPPLY. *S/D* BATTERY WAS NOT SECURE IN POWER SUPPLY. REPLACED BATTERY AND SECURED FASTENERS.SDR 98UAL900190Light · illuminatedESCAPE SLIDE GIRT BAR ENGAGEMENT LIGHT AT DOOR 2R INOP. RELAMPING DID NOT HELP. *S/D* PROBLEM DUPLICATED BY TAPPING ON RH GIRT BAR SENSOR S10221 WHICH MADE SLIDE LIGHT COME ON. REPLACED S10221 PER MM AND OPS CHECKS NORMAL.SDR 98UAL900193Tire · blownLANDED UNDER AMBER ALERT DUE TO A SUSPECTED BLOWN TIRE.SDR 98UAL900194Window · damagedRETURNED TO FIELD SHORTLY AFTER TAKEOFF DUE TO LOOSE PASSENGER WINDOW FRAME. *S/D* BOTH PASSENGER WINDOWS AT ROW SIX ON THE RIGHT HAND SIDE OF FUSELAGE EXHIBITED DAMAGE DUE TO MISPLACEMENT OF GROUND POWER UNIT ON RAMP PRIOR TO DEPARTURE. ACCOMPLISHED VISUALSDR 98UAL900175Tube · failed testDURING SHOP OVERHAUL OF SLIDE/RAFT, IT FAILED THE AIR RETENTION TEST. FAILURE DUE TO POROSITY IN THE UPPER TUBE INFLATABLE MATERIAL. SLIDE/RAFT SENT TO VENDOR FOR REPAIR.SDR 98UAL900159Fseu · failedFLAPS WOULD NOT MOVE PAST 20 DEGREES. DIVERTED TO LAX. *S/D* FOUND FAULTY NR 1 FSEU. REPLACED FSEU, OPERATIONALLY CHECKED AND FOUND SYSTEM NORMAL.SDR 98UAL900156Reservoir · blownDOOR 2L HARD TO OPEN ON ARRIVAL AT GATE. *S/D* FOUND 2L DOOR OUT OF SEQUENCE AFTER DOOR OPENED PARTIALLY FROM OUTSIDE WHILE STILL ARMED. FOUND EMERGENCY POWER RESERVOIR BLOWN. REPLACED RESERVOIR AND RESEQUENCED DOOR, OPS CHECKS NORMAL.SDR 98UAL900150Bulb · failedEMERGENCY SLIDE LIGHT INOP, DOOR 4L. LAMP BURNED OUT. REPLACED.SDR 98UAL900136Compressor · stalledRETURNED TO FIELD AFTER HEARING LOUD NOISE AND SEEING A FLASH FROM THE RIGHT SIDE OF AIRCRAFT. ENGINES OPERATED NORMALLY UPON RETURN. *S/D* AUTOTHROTTLES ON, NO ABNORMAL INDICATIONS ON ANY ENG INSTRUMENT, NO EICAS MESSAGES. RETURNED TO ORD WITH NO FURTHER SDR 98UAL900126Compressor · damagedRETURNED TO SEA UNDER AMBER ALERT DUE TO NR 1 ENGINE COMPRESSOR STALL. *S/D* THE NR 1 ENGINE INGESTED ICE AND SUSTAINED DAMAGE TO THE HIGH PRESSURE COMPRESSOR. THE 6TH STAGE BLADES WERE FOUND TORN. THE DAMAGED BLADES WERE REPLACED. AS A PRECAUTIONARY, THESDR 98UAL900125Rod · brokenRETURNED TO ORD DUE TO NOISE IN NOSE GEAR AREA WHEN GEAR WAS RETRACTED. *S/D* RIGHT NOSE GEAR STRUT DOOR AND OPERATING ROD WAS DAMAGED FROM POSSIBLE DOOR IMPACT WITH BAGGAGE CART. REPLACED ROD AND DOOR.SDR 98UAL900121Seal · failedFLIGHT DIVERTED TO LAX AND LANDED UNDER AMBER ALERT DUE TO LOSS OF LEFT HYDRAULIC SYSTEM. *S/D* RUDDER RATIO CHANGE ACTUATOR ROD SEAL FAILED. REPLACED RRCA AND SERVICED LEFT SYSTEM.SDR 98UAL900137Bearing · wornUPON ARRIVAL, AGENT COULD NOT FULLY OPEN DOOR 2L. DOOR ONLY SWINGS TO THREE QUARTERS OF FULL TRAVEL. *S/D* REPLACED DOOR 2L ROTARY SNUBBER AND UPPER AND LOWER HINGE LINK BEARINGS, OPS CHECKED NORMAL.SDR 98UAL900106Pseu · defectiveRETURNED TO FIELD AT LAX UNDER AMBER ALERT DUE TO A NOSE GEAR INDICATION PROBLEM. *S/D* PSEU WAS GIVING FALSE SIGNALS. NOSE DOWN LOCK SYSTEM 1 AND 2 WAS OUT OF ADJUSTMENT. READJUSTED NOSE DOWN LOCK SYSTEM 1 AND 2.SDR 98UAL900105Disagree Light · illuminatedAIRCRAFT DIVERTED TO SLC DUE TO TE FLAPS DISAGREEMENT INDICATION. *S/D* AIRCRAFT OPERATIONALLY CHECKED GOOD, NO DISCREPANCIES FOUND.SDR DL757980512Actuator · crackedDURING CLIMB-OUT, LEFT ENG WOULD NOT REACH COMMANDED CLIMB EPR N2 IND 100 FF MATCHED RT ENG EVENT RECORD PUSHED AT HIGHER ALT. LEFT ENG EPR IND CONT TO FALL OFF OIL TEMP REACHED 129. REPLACED STATOR VANE ACTUATOR AND BRACKET.SDR 9803605644Stator Alt · failedDURING TAKEOFF ROLL, THE NR 2 ENGINE PRIMARY CONTROL MESSAGE ANUNCIATED AND THERE WAS NO EPR INDICATION. TAKEOFF WAS ABORTED AT 10 KNOTS AND THE AIRCRAFT RETURNED TO THE GATE. MAINTENANCE REPLACED THE NR 2 EEC STATOR ALTERNATOR.SDR 98UAL900083Axle · crackedAIRCRAFT AT MAINTENANCE BASE FOR GEAR CHANGE. NEW RT MLG AFT INBD AXLE SHEARED AFTER DE-JACKING OF AIRCRAFT. *S/D* HEAT DAMAGE INDUCED BY OEM FINISH GRINDING ON THE OD CHROME PLATE, 19.25 INCHES FROM AXLE THREADED END. REPLACED AXLE AND INSPECTED REMAININGSDR 98UAL900078Fseu · failedFLIGHT CREW UNABLE TO FULLY EXTEND FLAPS. DIVERTED TO LAX. *S/D* FOUND FAULTY FSEU NUMBER 1. REPLACED FSEU AND OPERATIONALLY CHECKED GOOD.SDR 98UAL900079Actuator · failedON TAKEOFF CREW HAD TO USE OVERRIDE TO RAISE GEAR. *S/D* BLOWN PISTON SEAL IN TRUCK POSITION ACTUATOR. REPLACED ACTUATOR.SDR 98UAL900063Handle · not closedNO WATER PRESSURE AND LOUD NOISE FROM REAR OF AIRCRAFT. RETURNED TO FIELD. *S/D* THE POTABLE WATER SERVICE FILL VALVE HANDLE HAD BEEN LEFT IN THE OPEN POSITION DURING SERVICING. POTABLE WATER SERVICE FILL HANDLE WAS CLOSED. NO DEFECTS WERE FOUND.SDR 98UAL900048Light · defectiveLEFT MAIN GEAR, NO GREEN LIGHT WITH GEAR DOWN. EXTENDED GEAR BY ALTERNATE METHOD. LANDED UNDER AMBER ALERT. *S/D* REPLACED THE LEFT GEAR INDICATION LIGHT ASSEMBLY.SDR 98UAL900046Oil Line · blockedNUMBER 2 ENGINE OIL QUANTITY DROPPED, OIL PRESSURE FLUCTUATED AND DROPPED TO 100 PSI. CREW SHUT DOWN ENGINE. *S/D* OIL LOSS WAS DUE TO EXCESSIVE CARBON IN THE NR 5 BEARING OIL SCAVENGE LINE. THE NR 5 BEARING OIL NOZZLE WAS BLOCKED BECAUSE THE LAST CHANCE FSDR 98ZZZX1117Bearing · failedENGINE REMOVED FOR METAL IN CHIP COLLECTORS, NRS 1, 2, AND 3. DISASSEMBLY INSPECTION REVEALED FAILED NR 2 MAIN BEARING. ONE BALL SPALLED AND BEARING CAGE MUSHROOMED ON OD, SILVER PLATE WORN OFF ONLY AT SPALLED BALL AREA. BEARING FORWARDED TO PRATT & WHITNEYSDR 98UAL900031Fire Detector · failedLEFT ENGINE HAD FIRE LP2 INDICATION. *S/D* FOUND LOWER CORE NUMBER 2 LOOP FAULTED. REPLACED THE DETECTOR ASSEMBLY AND THE SYSTEM OPERATIONALLY CHECKED NORMAL.SDR 98UAL900033Lamp · failedEMERGENCY SLIDE LIGHT FOR RIGHT-HAND OVERWING SLIDE IS INOP. *S/D* RELAMPED.SDR 9800095641Compressor · stalledDURING TAKEOFF ROLL, THE NR 2 ENGINE EXPERIENCED A COMPRESSOR STALL. TAKEOFF WAS ABORTED AT 10 KTS. BORESCOPE INSPECTION REVEALED COMPRESSOR DAMAGE. MAINTENANCE REPLACED THE NR 2 ENGINE.SDR 97UAL900895Handle · brokenAT DEPARTURE CHECK, FLIGHT CREW DISCOVERED AFT RAFT OPEN LOCK HANDLE BROKEN. *S/D* CAUSE NOT DETERMINED. ACCOMPLISHED INTERIM REPAIR. OPERATIONAL CHECK OF HANDLE WITH INTERIM REPAIR OK. REPLACED HANDLE AT NEXT MAINTENANCE OPPORTUNITY.SDR 97UAL900879Hose · rupturedLANDED UNDER AMBER ALERT. LEFT HYDRAULIC QUANTITY DROPPED TO ZERO WITH ASSOCIATED WARNINGS THAT INDICATED TRUE HYDRAULIC LOSS IN THE LEFT SYSTEM. LEFT PUMPS SHUT DOWN. *S/D* REPLACED THE LEFT MLG DRAG BRACE DOWNLOCK ACTUATOR HOSE. THE HOSE WAS LEAKING WHESDR 97UAL900881Valve · frozenDURING THE SHOP OVERHAUL OF AN EVACUATION SLIDE REMOVED FOR EXPIRATION OF TIME, THE UNIT FAILED TO FLAT FIRE. MECHANIC PULLED THE FIRING LINE WITH A FORCE OF 20 LBS AND THE BOTTLE VALVE DID NOT OPEN. THE BOTTLE VALVE MANUFACTURER (CARLTON) HAS THE VALVE, (P/SDR 97UAL900867Valve · defectiveDURING ROUTINE SHOP MAINTENANCE, EVACUATION SLIDE FAILED TO INFLATE. UPON PARTIAL DISASSEMBLY OF THE BOTTLE VALVE BODY THE COUPLING PIN (P/N 10003-0005-293) WAS FOUND TO BE BADLY BENT AND SHAFT (P/N B18116-1) WAS SPREAD. THE BOTTLE VALVE WAS REPLACED.SDR 97UAL900841Lamp · inoperativeAFT LEFT HAND EEL LIGHTS AT DOOR 4L ARE INOP. REPLACED LAMP, CHECKS OK.SDR 97UAL900842Slide · disassembledAT DEPARTURE TIME FOUND APPROXIMATELY 15 FEET OF GREEN CORD HANGING OUT OF DOOR 4R. SLIDE REPLACED. *S/D* CAUSE UNKNOWN. REPLACED DOOR SLIDE.SDR 97UAL900840Mechanism · out of adjustRETURNED TO FIELD DUE TO DOOR 4L HANDLE POPPING UP. *S/D* DOOR OUT OF ADJUSTMENT. WHILE PRESSURIZED, THE DOOR HANDLE WAS ABLE TO MOVE, WHEN A SMALL AMOUNT OF FORCED WAS APPLIED, DUE TO LOSS OF OVERCENTER. ADJUSTED LOWER GATE, COCKING PUSH ROD, DOOR STOP PISDR 97UAL900839Idg · failedLEFT GENERATOR DRIVE OFF LIGHT ON DURING DEPARTURE. RETURNED TO FIELD. *S/D* THE INTEGRATED DRIVE GENERATOR HAD INTERNAL PISTON FAILURE. REPLACED LEFT (NR 1) INTEGRATED DRIVE GENERATOR.SDR 97UAL900844Regulator · corrodedDURING SHOP OVERHAUL OF SLIDE REMOVED FOR EXPIRATION OF TIME THE REGULATOR BODY AREA WAS FOUND TO BE BADLY CORRODED. *S/D* REPLACED REGULATOR.SDR 97UAL900845Regulator · corrodedDURING SHOP OVERHAUL OF SLIDE REMOVED FOR EXPIRATION OF TIME THE REGULATOR BODY AREA, SPRING AND PISTON WERE FOUND TO BE CORRODED. REPLACED REGULATOR.SDR 97UAL900846Regulator · corrodedDURING SHOP OVERHAUL OF SLIDE REMOVED FOR EXPIRATION OF TIME THE REGULATOR VALVE AREA AND PISTON WAS FOUND TO BE BADLY CORRODED. REPLACED REGULATOR.SDR 97UAL900823Handle · brokenLEAD SEAL BROKEN ON WATER FIRE EXTINGUISHER. *S/D* CHARGE HANDLE WAS FOUND FROZEN OPEN WITH CORROSION. REPLACED BOTTLE.SDR 97UAL900822Slide · disconnectedNR 1 RT SLIDE ENGAGE LIGHT INOP. *S/D* RESECURED GIRT MECHANISM, OPS CHECKED NORMAL.SDR 97UAL900806Lvdt · failedON CLIMBOUT LOUD NOISE HEARD AND EGT WENT TO 705. RIGHT ENGINE WAS SHUTDOWN. *S/D* ENGINE EXPERIENCED A COMPRESSOR STALL DUE TO AN INOP STATOR VANE ACTUATOR (SVA) FEEDBACK CHANNEL. THIS SITUATION CAUSED THE SVA TO GO TO FAIL-SAFE POSITION (FULL OPEN). WHE
Back to Pratt & Whitney PW2037