SDR UALA2012012000439Floor Panel · damagedFLOOR SOFT IN AISLE NEAR 34C AND 35C. FLOOR PANEL AT AISLE ROW 35 - 2" SOFT SPOT, 4" FROM EDGE OF PANEL. ACP'D INTERIM REPAIR PER MM. INSTALLED ALUM METAL 0.071" THICKNESS OVERLAP ON SOFTNESS AREA. REPLACE FLOOR PANEL AT NEXT "C" CHECK.SDR UALA2012012000426Floorbeam · corrodedFLOORBEAM STA 395 RBL 55 HAS CORROSION AT NUT CLIP HOLE. REPAIRED PER ECRA 5310-05 433 ON SCAL LOG PAGE 9957145.SDR UALA2012012000440Mechanism · out of adjustCAP WINDOW LOCKING MECHANISM HARD TO MOVE. ADJUSTED LEFT SLIDING WINDOW LOCKING HANDLE MECHANISM.SDR UALA2012011900414Duct · dirtyCOCKPIT NOISE. ACP'D NOISE CHECK PER MM, FAILED CHECK 76 DCB. REMOVED OVERHEAD DISTRIBUTION DUCT NOZZLE ASSY AND RESTRICTOR PLATE ASSY AT ROW 37 AND FOUND RESTRICTOR PLATE HOLES 90% BLOCKED WITH DEBRIS. CLEANED OVERHEAD DISTRIBUTION DUCT FROM ROW 12 TO 37. SDR UALA2012012000427Unknown · malfunctionedLEFT CENTER FUEL PUMP LOW PRESS DOES NOT ILLUMINATE, BULB CHECKS GOOD. MEL PROCEDURE COMPIED WITH, EICAS MESSAGE CHK'D OKAY. RESET SYS RAN PUMPS WITH FUEL DOOR OPENED, OPS OK. CLOSED DOOR PUMPS OFF.SDR UALA2012012000438Connector · looseALTN STAB TRIM CB B19 POPS WHEN ELEC PEDESTAL TRIM SWITCHES ARE MOVED. FOUND STCM CONN D01847 LOOSE BY 1 TURN. REMOVED & INSPECTED LOCK MECH. CLEANED & SECURED. CHECKED ALL REMAINING CONNECTORS OKAY. OPERATED ALT SYS MANY TIMES OK.SDR UALA2012011900392Structure · damagedLWR AFT FUSELAGE, INSTALLED 2 EA DOUBLERS AT STA 1393 AND 1433 STR 28 REF TASK CARD 59745401C. INSTALLED 2EA DOUBLERS REF WC 59745401C.SDR UALA2012011900394Skin · buckledFUSELAGE SKIN BUCKLED AROUND SEVERAL RIVETS STA 607-613 STRINGER 16 L. ACCOMPLISHED REPAIR ON FUSELAGE SKIN DURING HMV CHECK AT SCAL PER ECRA 5330-04185 ON LOG 9954986.SDR UALA2012011900424Seal · leakingLOUD HISS COMING FROM AFT PART OF F/O SIDE WINDOW. F/O SLIDING WINDOW BULB SEAL LEAKS ACCESSIVELY DURING PRESSURIZATION, BULB SEAL IS DEFORMED ALSO. RPLD F/O SLIDING WINDOW BULB SEAL. PRESSURIZED ACFT TO 4D PSI, STILL HAVE LEAKAGE AT FWD LWR PORTION OF WINDSDR UALA2012011800370Frame · corrodedAFT PIT FRAME HAS CORROSION BS 1500, STR 30 & STR 29L. MAJOR REPAIR ACCOMPLISHED. RMV'D CORROSION ON FAIL SAFE & FOUND MATERIAL REMAINING AFTER BLEND-OUT TO BE .071\ FROM AN ORIGINAL .080\. RMV'D FAILSAFE CHORD, AND SPLICED IN REPAIR WITH 2 NEWLY FABRICATEDSDR UALA2012011800371Floorbeam · corrodedPASSENGER CABIN MAIN DECK FLOORBEAM STA 377 RBL 48-63 IS CORRODED UPPER CAP. MAJOR REPAIR ACCOMPLISHED. REPAIRED DURING HMV 4 PER ECRA 5310-05432. WORK ACCMP'D ON SCAL LOG 99556 62.SDR UALA2012011900391Floorbeam · corrodedPASSENGER CABIN MAIN DECK FLOORBEAM STA 377 RBL 48-63 IS CORRODED UPPER CAP. ACCOMPLISHED REPAIR DURING HMV 4 PER ECRA 5310-05432. WORK ACCOMPLISHED ON SCAL LOG 99556 62.SDR UALA2012011900415Skate Angle · crackedNR 1 ENG PYLON SKATE ANGLES CRACKED. EG MANDATED SKATE ANGLE REPLACEMENT. PARTS IN HAND. IN FUEL TANK REMOVING ANGLES.
REF SMC1, INBD AFT SKATE ANGLE REMOVED FOR REPLACEMENT. STARTED PICKING UP FASTENER HOLES & INSTALLING NUT PLATES. REPLACED SKATE ANGLSDR UALA2012011700362Light · inoperativeEMERGENCY LIGHT OUTSIDE OF DOOR 1RT INOP. RELAMPED AND REPAIRED SOCKET.SDR UALA2012011600326Module · faultyCARGO FIRE SYST FAIL LIGHT DOES NOT ILLUMINATE ON TEST. REPLACED SWITCH MASTER MODULE AND CARD M10427, TESTS OKAY.SDR UALA2012011600351Generator · leakingHYDRAULIC MOTOR GENERATOR LEAKING. REPLACED HMG, LEAK CKS OKAY.SDR UALA2012011600322Light · inoperativeCENTER LAV FLOOR EEL LIGHT INOP. FOUND BROKEN WIRE TAPE. REPLACED EEL STRIP, OPS CHECKED NORMAL.SDR UALA2012011600323Pca · faultyAUTOSPEED BRK SYS FAILUIRE, RTFL. SPOILER AUTO STOW MOTOR ACTIVATED DURING CLIMB WITH SPOILER LEVER STOWED. REPLACED NR 9 SPOILER PCA PER MM.SDR UALA2012011600317Door Frame · corrodedAFT CARGO AFT DOOR FRAME HAS A CORRODED HOLE APPROX .0250 DIA STA 1440 ABOVE STA S27R. REPAIR ACCOMPLISHED DURING HMV 4 ON SCAL LOG 9957898 PER ECRA 5310-05436.SDR UALA2012011600318Rod · out of positionPASSENGER ENTRY-SERVICE DOORS L CTR NOISE FROM AIR LEAK (PROG TEXT: ACCOMPLISH CHRONIC REVIEW). FOUND UPPER AND LOWER GATE DIAPHRAGM SEAL NYLON RODS OUT OF RETAINERS. RE-INSTALLED RODS SEALS GATE CORNERS AND PRESSURIZED AND LEAKED CHECK, OKAY.SDR UALA2012011600321Light · inoperativeRIGHT WW RED UNSAFE LIGHT INOP. RELAMPED, NO HELP. VERIFIED NO POWER AT SOCKET SWITCH NOT AT SEAMM. REPLACED LAMP AND SECURED WIRING.SDR UALA2012011600349Skin · dentedDENT REPORTED ON LT FUSELAGE FORWARD OF DOOR 2L. DENT AT BS 620 STR 15L AND MEASURES 1 X 1 X .09 OPBLM. ACP EDDY CURRENT, NO CRACK PERFORMED INTERIM REPAIR PER ECRA 5330-04 194 PART 1 OK TO CONTINUE AND PERMANENT REPAIR OF THE FUSELAGE SKIN AND STRINGER AS RSDR UALA2012011200262Light · inoperativeEEL LIGHTS ON SEAT NR 1 AND SEAT NR 20 IS INOP. RELAMPED AFT EEL STRIP AT 1AB PER MM AND SECURED EEL STRIP CONNECTOR AT 20ABC. BOTH STRIPS OP OK.SDR UALA2012011200263Girt Bar · dirtyL1 DOOR WOULD NOT DISARM. FOUND DEBRIS IN GIRTBAR PAWL AREA. REMOVED, CLEANED, AND ADJUSTED SLIDE PACK STRAPS, OPS OKAY.SDR UALA2012011200264Actuator · leakingFOUND LEFT WING AILERON INBD ACTUATOR LEAKING FROM ROD END SEAL. REPLACED LEFT WING AILERON INBD ACTUATOR.SDR UALA2012011100244Controller · uncontrollableUNABLE TO CONTROL TEMP BOTH PACKS-ONE PACK-TRIM AIR ON OR OFF. REPLACED ZONE TEMP CONTROLLER PER MM AND RT PACK TEMP CONTROLLER PER MM. RAN BOTH PACKS OFF OF APU AIR IN MANY DIFFERENT TEMP CONFIGURATIONS AND TEMP CONTROL WAS NORMAL.SDR UALA2012011100245Pressure Switch · failedAC MOTOR PUMP, WITH HYDRAULIC PUMP OFF. LOW PRESSURE LIGHT DID NOT ILLUMINATE OR EICAS MESSAGE DISPLAY, CENTER PUMP NUMBER 1. EICAS MESSAGE DISPLAYS CORRECTLY. REPLACED LOW PRESSURE SWITCH.SDR UALA2012011100246Unknown · odorFLIGHT ATTENDANT NOTIFIED COCKPIT OF A SMOKE ODOR BY DOOR 2, ODOR WENT AWAY AFTER 5 MINUTES. ODOR WAS AROUND THE OVERWING EXITS ROW 20. CHECKED CEILING, ENTRY AND WINDOW LIGHTS AROUND EXIT ALL WORKING NORMALLY. CHECKED READING/CALL LIGHTS AND OPERATED VIDESDR UALA2012011100249Gcu · inoperativeRIGHT GENERATOR CONTROL UNIT INOPERATIVE EICAS MESSAGE ILLUMINATED AFTER ENGINE START. REPLACED GENERATOR CONTROL UNIT PER MM AND RAN BOTH ENGINES PER JRH AND FOUND GENERATOR TO BE OPERATING NORMAL.SDR UALA2012011100247B-Nut · leakingFOUND SMALL AMOUNT OF STRAW COLORED FLUID UNDER RT AILERON ON WALKAROUND. SECURED FOUR B-NUTS. RAN AILERONS THRU SEVERAL CYCLES, NO LEAKS NOTED.SDR UALA2012010900183Cartridge · faultyL4 DOOR DIFFICULT TO ARM AND DISARM. REPLACED OVERCENTER SPRING CARTRIDGE. ALSO CLEANED AND LUBED ARM DISARM MECHANISM. OPS CHECKED GOOD.SDR UALA2012010900184Rod · damagedR4 DOOR ARM DISARM INDICATOR ATTACH ROD IS RUBBING OTHER LINKAGE AT FWD END AND IS DAMAGED. REMOVED AND REPLACED ATTACH ROD PER AMM, OPS CHECKED GOOD.SDR UALA2012010900185Rod · out of adjustL4 DOOR ARM DISARM INDICATOR ATTACH ROD IS RUBBING THE LINKAGE AT FWD END AND IS DAMAGED. REPLACED ARM DISARM INDICATOR ATTACH ROD AND ADJUSTED PER AMM. ACCOMPLISHED INSPECTION FOUND SECURE, OPS NORMAL. NO RUBBING.SDR UALA2012010900174Transducer · intermittentNO LAND 3 DISP ON ASA WITH SYS ENGAGED IN CMD. SOURCE SELECT IN 2 (1=L ,2=C, 3=R) POS. CREW COMMENTS: LEFT AP SAME THING. FOUND FAULT FEEL POS-FCC C. FLIGHT FAULT CODES ARE FLT 5-132221,122221, FLT 22-132221, FLT 30-132221, FLT 40-122221, CARRIED OUT TRANSDR UALA2012010900171Module · faultySTATUS MSG 'ELEV ASYM' DISPLAYED. FOUND BOTH SRM'S HAD ELV ASSY ACT FAULT BALLS (CONT OF AMIS ITEM 0322003). BOTH SRM RESET MSG BY ITSELF. PERFORM BOTH SRM TEST AND YAW DAMPER TEST AND RUDDER RATIO TEST ALL PASS, N FAULT IN HIS MCDP. GRD TEST MCDP TEST 8,6SDR UALA2012010900165Cartridge · dirtyR4 DOOR DIFFICULT TO ARM AND DISARM. TROUBLESHOT PER FIM. CLEANED OVERCENTER SPRING CARTRIDGE. DOOR ARMS AND DISARMS NORMALLY NOW.SDR UALA2012010900209Idg · defectiveRIGHT GENERATOR TRIPPING ON ENGINE START. SEVERAL POWER LEADS FOUND SLIGHTLY LOOSE ON IDG. SECURED POWER LEADS PER AMM. ACP ENG RUN AT GATE. CKS OKAY. AIRCRAFT RETURN TO GATE. RIGHT ENGINE GENERATOR TRIPPING OFF LINE. REPLACED IDG PER AMM, OPS CK GOOD.SDR UALA2012010900208Switch · faultyELEVATOR C HYD PRESS STATUS ON SHUTDOWN. CHRONIC SUPPLEMENTAL DATA UPDATE REPLACED S10002 IAW FIM, SYSTEM OPS CKS NORMAL.SDR UALA2012011100243Fitting · leakingFLUID LEAKING FROM LEFT AILERON AREA. SECURED LOOSE HYD LINE FITTING AFT OF LEFT OUTBOARD AILERON PCA.SDR UALA2012010900211Cap · missingWINDOW R1 LOWER RT CORNER WINDOW HT WIRE CAP MISSING. INSTALLED CAP.SDR UALA2012010900213Wire · overheatedWIRING IN E&E COMPARTMENT JUST AFT OF RT OF TUNNEL HAS SIGNS OF OVERHEAT. SEE SMC10 WD24-53-51 DUE TO CHAFING AGAINST METAL CLAMP ON AC DUCT BELOW FLOORBOARD. SLEEVING DAMAGED ON WIRE RPR'D PER BOEING STD PRACTICES 20-10-13, PG 47.SDR UALA2012010900210Circuit Card · faultyR ENG BLEED OFF EICAS MSG ON TAKEOFF. REPLACE R ENGINE SPEED CARD. RAN ENGINE PER JRH, OPS CKS OKAY.SDR UALA2012010900207Thermocouple · faultyAPU ALTITUDE NO START - COLD SOAKED. APU SHUTDOWN AFTER REACHING 95 PERCENT SPEED AFTER 10 SECONDS. APU RAN STABILIZED AT 100 PERCENT FOR 1 MIN THEN APU FAULT AND APU GEN EICAS MESSAGE DISPLAYED. ACCOMPLISHED SUCCESSFUL APU ALT COLD SOAK START. REPLACED NSDR UALA2012010900160Relay · faultyCEILING LIGHTS ENTIRE RIGHT SIDE WILL NOT GO OUT WHEN TURNED OFF. REPLACED RELAY K10073 PER WD 33-21-11, OPS NORMAL.SDR UALA2012010900151Power Supply · inoperativeDURING TEST OF EMERGENCY LIGHTS, FLOOR LIGHTS INOPERATIVE. REPLACED POWER SUPPLIES M735 AND M10699. FLOOR EMERGENCY AISLE LIGHTS CHECKED GOOD. RELAMPED EMERGENCY LIGHT AT SEAT 5F, OPS CHECKED OKSDR UALA2012010900203Charger · failedAPU BATTERY TEST FAILS. REPLACED APU BATTERY CHARGER IAW AMM, OPS CHECKED OK.SDR UALA2012010900206Battery · faultyAPU FAULT DURING TAXI IN. APU START ATTEMPT SHOWS 5 VOLTS AT CRANK. APU BATTERY WARM TO TOUCH. REPLACED APU BATTERY IAW AMM.SDR UALA2012010900202Seal · failedCAPTAIN'S WINDOW VERY HARD TO UNLOCK AFTER ACFT HAS BEEN FLOWN OR PRESSURIZED. DUE TO CAPT WINDOW NOT OPENING AFTER FLIGHT, ADJUSTED NR 2 WINDOW PER MM. AFTER RIG, PRESSUREIZED ACFT PER MM, AND CHECKED WINDOW FOR PROPER OPERATION. REPLACED WINDOW SEAL PER SDR UALA2012010600132Wire · out of positionTHE 4 LT EXTERIOR FUSELAGE EMERGENCY EXIT LIGHT INOP. FOUND SECTION OF EMERGENCY AISLE LIGHTS, AND ONE EMER EXIT LIGHT AND SIGN LIGHT AND DOOR 4L EXT LIGHT IS OUT. ALL RECEIVE POWER FROM M10818 POWER SUPPLY, REF WDM 33-51-15 PG 1. (ON ORDER B29). FOUND OPENSDR UALA2012010900191Floor Panel · delaminatedFLOOR IS SPONGY AND SOFT BY ROW 37. INSPECTED AREA FOUND IT TO CONTINUE UNDER EEL STRIP IN ROW 37C. DELAMINATED AREA FOUND TO BE SMALL, APPROX 4 IN X 4 IN. FLOOR PANEL IS IN DRY AREA. MADE REPAIR PER MM.