Pratt & Whitney PW2040
Service difficulty reports · 2,201
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2040' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW2040' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013052203552Light · inoperativeEMERGENCY SLIDE LIGHT AT DOOR 1R IS INOPERATIVE. REPLACED NR 767 LAMP.SDR UALA2013052203524Floorbeam · damagedFLOORBEAM TEE HAS TWO ELONGATED HOLES. REMOVED UPPER TEE BS 1620 , BL 0 TO RBL 24.5. HFED INSPECTION AREA REF NDT PY 6, 51-00-19, NO DEFECTS NOTED. FABRICATED NEW UPPER TEE SECTION, REF ECRA 5310-05536 AND INSTALLED TWO STRAPS, AND TWO REPAIR ANGLES, AND USDR UALA2013052203540Attach Bracket · brokenHALON FIRE EXTINGUISHER BRACKET BROKEN AT FIRST CLASS BULKHEAD, ACFT LEFT. ATTACHED BRACKET AT FIRST CLASS BULKHEAD FIRE EXT, OPS CHECKED GOOD.SDR UALA2013052203544Bolt · undertorquedR1 WINDOW HAS AN AIR LEAKING IN THE UPPER RT CORNER. PERFORMED PRESSURE LEAK CHECK PER AMM 05-51-24. FOUND LEAKS DUE TO WINDOW RETAINING BOLTS ARE UNDER TORQUED BY 15 TO 20 INCH POUNDS. TORQUED BOLTS AND LEAK CHECKED GOOD.SDR UALA2013052203537Fan · vibratesABNORMAL NOISE, VIBRATION AROUND RT GLARESHIELD OR RT WINDSHIELD AREA. RADIO COMMUNICATION DIFFICULT. R & R LEFT CABIN RECIRCULATION FAN IAW AMM. OPS CHECKED GOOD.SDR UALA2013052203539Filter · faultedHIGH PITCHED WHINE BEHIND INSTUMENT PANEL. REPLACED LT RECIRCULATION FAN FILTER. OPS CHECKED NORMAL.SDR UALA2013052303560Wire · damagedNR 1 FLAP SLAT SENSOR CIRCUIT BREAKER WILL NOT RESET. ACCOMPLISHED SLICE REPAIR ON WIRES W3326-2510, R20 AND W3326-2510 B20 IAW WDM 27-51-41. IAW BSWPM 20-30-19, SPLICE NEW WIRES FROM FSS 720 TO FSS 812 AND TERMINATED AT CONNECTOR D2984, REF BSWPM 20-10-11. SDR UALA2013052203543Converter · failedFIRST OFFICER`S WINDSHIELD WIPER DOESN'T COMPLETE A FULL SWEEP AND CONTINUES TO RUN WITH SWITCH OFF. REPLACED WINDSHIELD WIPER MOTOR CONVERTER.SDR UALA2013052203536Faucet · damagedPOTABLE WATER SYS INOPERATIVE. REPLACED FWD LAVATORY FAUCET.SDR UALA2013052803682Cover · unsecureEMERGENCY LIGHT COVER DISLODGED 20A. SECURED EMERGENCY EXIT COVER. OK FOR SERVICE.SDR UALA2013052203535Panel · damagedFAIRING AFT OF NR 1 ENGINE, UNDER WING HAS DAMAGE. DAMAGE IS TO ENGINE AFT FAIRING PANEL MEASURES 1.25" LONG BY 1" DEEP. FAIRING REMOVED AND REPAIRED. INSTALLED AND SEALED PANEL.SDR UALA2013052203542Gcu · failedLEFT AC BUS FAILURE, RTFL. REPLACED NR 1 GCU.SDR UALA2013052003483Sensor · faultyCREW REPORTED CABIN HOT & SLOW TO COOL, TOOK TWO HOURS. RT PACK CONTROLLER SHOWS RT PACK SENSOR FAULT. REPLACED RT PACK NR 1 TEMP SENSOR IAW MM. LEAK AND OPS CHECKED GOOD.SDR UALA2013052003480Armrest · brokenARM REST ASSY AT 20D IS BROKEN. SECURED 20A ARMREST END CAP. OK TO CONTINUE.SDR UALA2013052103495Attach Fitting · crackedDOOR 1R GIRT BAR FWD SIDE LEAF SPRING ATTACH FITTING IS CRACKED. INSTALLED SERVICEABLE GIRT BAR IAW AMM, OPS CHECKS NORMAL. NR 40828 .SDR UALA2013052103496Jumper · faultyFLOOR EEL LIGHT STRIP INOP FROM SEAT ROW 8 ABC TO 11 ABC. REPLACED JUMPER REF IPC 33-52-00. OPERATES NORMALLY.SDR UALA2013052003482Charger · faultyMAIN BATTERY CHARGER STATUS MESSAGE. REPLACED MAIN BATTERY CHARGER.SDR UALA2013052103492Lug · corrodedPOTABLE WATER INOP IN AFT LAVS AFTER 4 HRS OF FLT. SUSPECT WATER LINE HEATER TAPE THERMOSTAT, B10105. NEED PCN 563-0015. SHUTOFF WATER ONLY. LOCATE WATER LINE HEATERS TO AFT LAVS IN REF TO IPC 38-13-01-001,VERIFY IF POWER PRESENT AND REPLACE INOP HTR TAPESSDR UALA2013052003469Indicator · damagedLEFT MAIN FUEL INDICATOR HAS MISSING SEGMENTS ON THE REFUELING PANEL. REPLACED INDICATOR, TEST OK.SDR UALA2013052003470Pressure Switch · failedLEFT ENGINE HYDRAULIC PRESSURE LIGHT DOES NOT ILLUMINATE WITH ENGINE OFF. REPLACED EDP HYDRAULIC PUMP PRESSURE SWITCH IAW AMM 29-11-17. MOTORED ENGINE AND PUMP AND INDICATOR LIGHT WORKS NORMAL.SDR UALA2013052003458Floorbeam · damagedFLOORBEAM, BS 1600, RBL 8-11 DAMAGED. INSTALLED REPAIR STRAPS AND ANGLES. MAJOR REPAIR.SDR UALA2013052003461Skin · dentedDENT FOUND AT BS 650, STRINGER 15, LT FORWARD OF DOOR 2L ON EXISTING DOUBLER. FOUND DENT WITHIN LIMITS OF SRM 53-00-01, PAGE 104.SDR UALA2013052003442Floorbeam · corrodedFLOORBEAM CORRODED AT BS 324, FROM RBL48-54. REMOVED DAMAGE, ORIGINAL MATERIAL .120", FOUND .016" REMOVED. HFEC INSPECTION, BLEND AREA REF NDT PT 6, 51-00-19, NO DEFECTS NOTED. IN LIMITS REF SRM 53-10-08, FIG 101. MAJOR REPAIR.SDR UALA2013052003444Stringer · crackedSTRINGER 14L BETWEEN BS 640 - 660 HAS SEVERAL CRACKED FASTENERS. CUTOUT DAMAGED SECTION OF STRINGER. HFEC INSPECTED ALL DAMAGE REMOVED REF NDT PT 6, 51-00-19, NO DEFECTS NOTED. INSTALLED NEW STRINGER SECTION SRM 53-00-03, FIG 201, DWG 143N3110-18, AND SRM51-SDR UALA2013051703436Nut · looseRIGHT AFT ENTRY DOOR EICAS MESSAGE DURING TAXI CYCLES ON AND OFF. WHEN HANDLE IS CLOSED AND IT STILL JIGGLES A LITTLE, RIGHT AFT ENTRY DOOR EICAS MESSAGE IS DISPLAYED & OVERHEAD ENTRY DOOR LIGHT IS ILLUMINATED. WHEN HANDLE IS CLOSED HARD, WITH NO LOOSENESS, SDR UALA2013051703437Skin · damagedSKIN BS 556-602 S24L DAMAGED. CUT OUT LIGHTNING STRIKES. FABRICATED AND INSTALLED DOUBLER IAW EA 130458 AND ECRA 5330-04589.SDR UALA2013051703439Fitting · looseROW 23 FWD INBD SEAT ATTACH FITTING IS LOOSE. TIGHTENED FITTING IAW AMM.SDR UALA2013051603417Floorbeam · gougedMAIN CABIN FLOORBEAM BS 377 GOUGED AT LBL 28. REMOVED 3 INCHES OF SECTION OF UPPER TEE, INSTALLED FILLER AND ANGLE DOUBLER REPAIR IAW EC-RA 5310-05538. MAJOR REPAIRSDR UALA2013051703433Light · unsecureEMERERGENCY LIGHT LOOSE ROW 11. SECURED EMERGENCY LIGHT TO FLOOR, OK TO CONTINUE.SDR UALA2013051603416Floorbeam · corrodedCABIN FLOORBEAM, BS 345 HAS CORROSION FROM RBL 14-60. REMOVED DAMAGED SECTION OF T-CAP AND INSTALLED NEW SECTION T-CAP WITH TWO SLICE ANGLES IAW DWG 1518-338, REV C, AND ECRA 5310-05538. MAJOR REPAIR.SDR UALA2013051703420Floorbeam · corrodedFLOORBEAM BS 365 CORRODED FROM RBL 4 TO 57. CUTOUT DAMAGE SECTION OF UPPER TEE, INSTALLED ATTACH ANGLE AND STRAPS AT BS 365 LBL 12- RBL 6 IAW ECRA 5310-05536, AND SRM 51-40-02. MAJOR REPAIR.SDR UALA2013052003481Threshold · dentedRAMP REPORTED A DENT IN FWD CARGO ON LOWER THRESHOLD. REPAIRED IAW AMM 53-20-99 PERMANENT REPAIR COMPLETE.SDR UALA2013052103494Actuator · failedLT MAIN TANK TRANSFERRED INTO "C" TANK. CREW COMMENTS: FROM TAKEOFF TO LEVEL OFF, APPROX 30 MINS, 800 LBS TRANSFERD TO CENTER TANK. REPLACED FAILED LT MAIN TANK FILL VALVE BODY ACCT FAILED AND FILL VALVE ACTUATOR IAW MM.SDR UALA2013051703421Floorbeam · damagedMAIN CABIN BS 395, LBL 45, TWO HOLES IN FLOORBEAM TEE OUT OF ROUND. FABRICATED AND INSTALLED ANGLES AND FREEZE PLUGS IAW ECRA 5310-05745 AND EA 130470. MAJOR REPAIR.SDR UALA2013051703422Frame · corrodedAFT CARGO EQUIPMENT BAY BILGE FRAME WEB IS CORRODED BS 1661, STR 27-28L. TRIMMED OUT DAMAGE AND REPAIRED WEB IAW ECRA 5360-01292 AND EA 130471. MAJOR REPAIR.SDR UALA2013051703423Skin · dentedFOUND NUMEROUS DENTS ON THE UPPER SURFACE OF THE RT HORIZONTAL STABILIZER. FOUND DENTS TO BE WITHIN LIMITS IAW SRM 55-10-01. ACCOMPLISHED HFEC IAW NTM 51-00-19, PRT 6 AND 51-00-05 PRT 4, NO DEFECTS NOTED. REPAIRED IAW SRM 51-70-01, REPAIR 1. DENT 300" FROSDR UALA2013051703418Light · inoperativeFIRST SECTION OF EMERGENCY LIGHTS IN COACH INOPERATIVE. REPLACED POWER STRIP AND LIGHT SECTION, OP CHECKED OK.SDR UALA2013051603401Skin · damagedLIGHTNING STRIKES ON RIVETS, LT SIDE OF FUSELAGE BETWEEN BS 239 - 325 STRINGERS 19 AND 22L. REPLACED RIVETS.SDR UALA2013051603407Grill · damagedAFT CARGO AFT BULKHEAD, LEFT BLOWOUT PANEL GRILL, HAS ONE ROD SEGMENT BROKEN. REPLACED BLOWOUT PANEL GRILL.SDR UALA2013051603408Deflector · crackedNR 2 ENGINE HAS CRACKED THRUST REVERSER DEFLECTOR DOOR AT 11 O'CLOCK POSITION. REMOVED CRACKED DOOR.SDR UALA2013051603399Tee Fitting · corrodedBS 1640 TEE CORRODED. CUTOUT DAMAGED TO UPPER TEE AND INSTALLED REPAIR IAW ECRA 5310-05536.SDR UALA2013051603406Oxygen Mask · faultyOXYGEN MASK DEFECTIVE. DIAPHRAM STICKING. NEED STRONG INHALE TO GET O2 TO FLOW. SWAPPED FO'S O2 MASK WITH OBSERVERS POSITION. NEW MASK OPS TEST OK IAW AMM.SDR UALA2013051603391Skin · misrepairedLEFT WING NR 5 SLAT UPPER T/E ATTACH FASTENERS AT EACH RIB ATTACH POINT ARE SCREWS WITH A "VF" HEAD MARKING WHILE SM-50-57-56-01-JD, PG 56 CALLS OUT FOR LOCK FASTENERS AT THESE LOCATIONS.SDR UALA2013051603392Skin · damagedDAMAGE NOTED TO FUSELAGE SKIN AT BS 1445-1455 BETWEEN S23-24R. REPAIRED DAMAGE IAW EA130487 AND ECRA5360-01285 HFEC WAS CW IAW NDT PT6 51-00-1 9. NO CRACKS NOTED.SDR UALA2013051603398Panel · unknownCOCKPIT ESCAPE ROPE PANEL WILL NOT SECURE. SECURED CAPT'S ESCAPE ROPE PANEL.SDR UALA2013051603415Cap · unsecureEMERGENCY LIGHT PLASTIC STRIP COMING UP AT ROW 14ABC. SECURED PLASTIC CAP IAW AMM.SDR UALA2013051603412Light · unsecureFLOOR LIGHT AT EDGE OF CARPET BY SECURITY GATE IS LIFTING. SECURED LIGHT.SDR UALA2013051603385Structure · misrepairedLEFT WING NR 3 SLAT UPPER SURFACE T/E WEDGE ATTACH FASTENERS 33" AND 45" FROM INBD EDGE SHOW FOUR LOCK FASTENERS IAW LOCATION REF SM-50-57-56-01-JD, PG 44. SLAT HAS ONLY 2 EA LOCK FASTENERS IAW LOCATION. REPAIRED.SDR UALA2013051503360Shear Tie · corrodedAFT CARGO BAY SHEAR TIE AT BS 1360 S26-27R CORRODED. REMOVED SHEAR TIE IAW SRM 51-40-02. FOUND TO BE OUT OF LIMITS IAW SRM 51-10 -02. FORMED NEW SHEAR TIE IAW DWG 146N1121. HEAT TREATED SHEAR TIE TO T6 CONDITION IAW DWG 146N1121. LOCATED AND DRILLED SHEASDR UALA2013051603382Floor Support · corrodedAFT CARGO BAY FLOOR SUPPORT LOWER SURFACE CORRODED BS 1357 TO 1365 RBL 10.5. REMOVED DAMAGE AND FOUND TO BE OUT OF LIMITS IAW 53-60-53 CUTOUT DAMAGE SECTION OF FLOOR SUPPORT AND REPAIRED IAW SRM 53-00-53, REPAIR 1. MAJOR REPAIR.
Back to Pratt & Whitney PW2040