Pratt & Whitney PW4060
Service difficulty reports · 7,186
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4060' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW4060' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013052003451Windshield · delaminatedFORWARD WINDSHIELD DELAMINATED ON F/O SIDE. INSTALLED R1 WINDOW IAW AMM 56-11-01.SDR UALA2013052003468Transceiver · failedDURING WEATHER RADAR TEST, RECEIVED A "WXR FAIL RT" MESSAGE. REPLACED WEATHER RADAR TRANSCEIVER IAW MM.SDR UALA2013052103498Lamp · inoperativeEMERGENCY LIGHT AT SEAT ROW 9JK INOPERATIVE. REPLACED LAMP, OPS CHECKED NORMAL.SDR UALA2013052103499Lamp · inoperativeEMERGENCY LIGHT AT LEFT AFT CROSS AISLE INOPERATIVE. REPLACED LAMP, OPS CHECKED NORMAL.SDR UALA2013052103511Fairing · missingRT ENGINE LOOKING AFT FROM ENGINE 5 O'CLOCK POSITION COMPRESSOR INTERMEDIATE CASE FAIRING RT SIDE PANEL SECTION MISSING. REPAIRED PER AMM 72-34-05. REPLACED MISSING FAIRING.SDR UALA2013052003452B-Nut · leakingHYDRAULIC FLUID LEAKING FROM NR 2 ENGINE STRUT DRAIN. FOUND EVIDENCE OF FLUID IN STRUT AREA. FOUND LEAKING B-NUT AT PYLON AREA. TIGHTENED B-NUT AND RESERVICED SYS IAW MM AND ACCOMPLISHED LEAK CHECK IAW MM 29-00-98, OK.SDR UALA2013051703440Smoke Detector · no testEQUIPMENT COOLING TEST, SMOKE LIGHT ON P5 AND EICAS ADVSRY MESSAGE FAILS TO APPEAR DURING TEST. REPLACED E&E SMOKE DETECTOR, CHECKED OK, IAW MM.SDR UALA2013051703419Lamp · inoperativeEMERGENCY LIGHTS INOPERATIVE. REPLACED LAMPS, CHECKED OK.SDR UALA2013051503379Shutoff Valve · faultyLEFT ENGINE HPSOV STATUS MESSAGE DURING DESCENT. REPLACED HPSOV IAW MM RAN ENGINE DUCT PRESSURE, NORMAL. NO FAULTS.SDR UALA2013051503363Power Supply · inoperativeCEILING EMERGENCY EXIT SIGN INOPERATIVE. JUST AFT OF SEAT ROW 14AB. REPLACED BATTERY POWER SUPPLY, OPS CHECKED NORMAL.SDR UALA2013051503362Power Supply · inoperativeEMERGENCY LIGHTS INOPERATIVE. SEAT ROWS 19 - 23 LT. REPLACED BATTERY POWER SUPPLY, OPS CHECKED NORMAL.SDR UALA2013051403330Line · leakingFOUND EVIDENCE OF LEFT OTBD AILERON, OTBD ACTUATOR, LEAKING HYDRAULIC FLUID. LT OTBD AILERON HYDRAULIC SUPPLY LINE GOING TO THE OTBD ACTUATOR HAS SEVERAL DEEP GOUGES IN HYD LINE APPROX ABOUT 5" FROM B-NUT ATTACHED TO OTBD ACTUATOR. R & R HYD SUPPLY LINE. SDR UALA2013051503377Switch · damagedRIGHT CENTER FUEL SWITCH SLOW. REPLACED SWITCH ASSY.SDR UALA2013051303290Control Panel · faultyCAPTAIN'S RADIO LOUD SIDE TONE EVERY TIME KEYED. REPLACED CAPTAIN`S AUDIO CONTROL PANEL.SDR UALA2013051403338Light · inoperativeSEAT 8J EMERGENCY LIGHT INOPERATIVE. REPLACED EMERGENCY LIGHT ASSY. OP CHECKED GOOD, NO FAULTS FOUND.SDR UALA2013051503380Indicator · faultyAIR BUBBLE IN RT FUEL QTY GAUGE. REPLACED FUEL QTY GAUGE IAW MM28-41-00, GROUND CHECKED NORMAL.SDR UALA2013051303316Blade · nickedNR 2 ENGINE FAN BLADE NR 10 HAS NICK ON L/E. DAMAGE IS 10 INCHES FROM ROOT TO A DEPTH OF 1MM. DAMAGE BLENDED OUT IAW MM.SDR UALA2013051303317Unknown · leakingNR 2 ENGINE FUEL LEAK AT 6 O'CLOCK POSITION. NO LEAKS NOTED. ENG GROUND RUN IAW JRH. REINSPECTED, NO LEAKS NOTED. REPLACED FUEL DISTRIBUTION VALVE IAW AMM. RAN NR 2 ENGINE, NORMAL OPERATION, NO LEAKS.SDR UALA2013051403337Connector · looseSEAT ROW 6A MOUNTED EMERGENCY LIGHT INOPERATIVE. FOUND EMERGENCY LIGHT CONNECTOR UNDER SEAT LOOSE. INSTALLED AND SECURED PLASTIC CONNECTOR UNDER SEAT, EMERGENCY LIGHT OP CHECKED GOODSDR UALA2013050903247Audio Panel · weakFIRST OFFICER`S AUDIO PANEL VOLUME WEAK ALL CHANNELS SPEAKER VOLUME OK HEADSET WEAK. REPLACED MINITEL.SDR UALA2013050803230Hose · damagedWHEN WORKING DF748 FOUND SUPPLY HOSE REF IPC 21-24-01-004A ITEM 15 WITH SMALL HOLE. NEW ONE ON ORDER AOG Z5340. REMOVED GASPER AIR FAN REF AMM. WAITING FOR PARTS TO INSTALL FAN. REPAIRED GASPER FAN HOSE IAW ECRA 2124-01007. RE-INSTALLED GASPER FAN REF.SDR UALA2013050803237Hinge · bentLIFE VEST STORAGE DOOR AT 7J CAUGHT IN FOOTREST, BENT, AND WILL NOT CLOSE. REPAIRED STORAGE DOOR HINGE AT 7J. OPS CHECKS GOOD.SDR UALA2013051003284Hydraulic Line · damagedHYD QTY DISPLAY IS BLANK. POS 2 (01=L,02=R,03=C). FRM CODE 29-33-04-XX. CREW COMMENTS: RIGHT QTY IND .49RF ALSO SATUS MSG R HYD SYS MAINT COMPLIED WQRH. FOUND HYDRAULIC TUBE AT RT ENGINE PYLON DAMAGED, REF IPC 29-11-00-002A INDEX 386. REPLACED HYD TUBE ANDSDR UALA2013050903246Latch · damagedLEFT PYLON HYDRAULIC BAY ACCESS DOOR AFT 4TH LATCH DAMAGED. REMOVED AND REPLACED LATCH, OPS NORMAL.SDR UALA2013050803229Sensor · intermittentEICAS MESSAGE LANDING GEAR MONITOR. PSEU FAULTING S232 SYS 1 NOSE GEAR DOWN SENSOR. TARGET TEST SHOWS FAR-SHOULD BE NEAR. TRIED SHIMMING SENSOR, NO HELP. SENSOR IS INTERMITTENT.SDR UALA2013050803231Nut Plate · damagedONE FASTENER MISSING FROM LEADING EDGE OF LEFT SIDE WING TO BODY FAIRING 195PL. REPLACED DAMAGED NUTPLATE.SDR UALA2013050903259Strap · brokenAVIONICS DUO PACK RIGHT SIDE MID GALLEY HAS BROKEN STRAP THAT SECURES PACK IN PACK TRAY. AVIONICS DUO PACK REMOVED FROM STOW BIN AT MID GALLEY RIGHT SIDE. STRAP TAPED ON INSIDE OF PACK TRAY AND SECURE. WILL NEED NEW RIVET TO SECURE STRAP. ONE UNIT REMOVEDSDR UALA2013050803227Latch · brokenAFT CARGO DOOR, CONTROL PANEL DOOR LATCH BROKEN. REMOVED AFT CARGO DOOR CONTROL EXTERIOR PANEL DUE TO BROKEN UPPER LATCH. LATCH WAS REPLACED.SDR UALA2013050903244Light · inoperativeBUSINESS CLASS CROSS AISLE LIGHT INOP IN FULL OK IN DIM. RELAMPED OKAY.SDR UALA2013050703201Connector · dirtyRIGHT HYDRAULIC ELECTRICAL DEMAND PUMP SYSTEM PRESSURE IS ZERO WITH SWITCH IN AUTO OR ON. CLEANED CONNECTOR, OPS CHECKED NORMAL.SDR UALA2013050703212Fan · failedWITH GASPER SWITCH ON, INDICATES OFF. GASPER FAN INOPERATIVE & SWITCH IS OFF POSITION. REMOVED GASPER FAN IAW AMM. REPAIRED GASPER FAN HOSE IAW ECRA 2124-01007. REINSTALLED GASPER FAN. FOUND TORN RUBBER BOOT FOR GASPER FAN. REPLACED BOOT.SDR UALA2013050603129Bushing · unsecureCHRONIC LOUD NOISE AND VIBRATION RT SIDE MID CABIN ON FLAP RETRACTION. SECURED MIGRATED BUSHING IN RT WING KRUEGER FLAP CLOSE OUT PANEL.SDR UALA2013050603144Circuit Breaker · trippedCREW REPORTED CIRCUIT BREAKER G17 ON P11 TRIPPED SHORTLY AFTER TAKEOFF. G17 FOR 1R CSEU AC PWR SUPPLY. RESET NOT ATTEMPTED DUE TO POWER SUPPLY 2R POWERING THE CSEU. RERACK CSEU POWER SUPPLY AND CHECK PINS ALL OK RESET CIRCUIT BREAKER. CIRCUIT BREAKER STAYSDR UALA2013050703211Actuator · malfunctionedDURING CRUISE, NO RT INBD AILERON INDICATION MOVEMENT. DISCONNECTED AUTOPILOT AND ACCOMPLISHED SERIES OF TURNS. CONFIRMED RT INBD AILERON WOULD NOT MOVE DOWN DURING TURNS. AILERON ALSO NOT FAIRED IN NEUTRAL POSITION AND REQUIRED LT AILERON TRIM TO MAINTAIN SDR UALA2013050203068Line · leakingLAVATORY SERVICE REPORTED WHEN SERVICING LAVATORY WITH BLUE WATER, FLUID STARTED TO COME OUT OF DRAIN HOLE IN FRONT OF SERVICE PANEL. REPLACED FILL LINE FOR FWD TANK FROM FILTER TO PRECHARGE SHUTOFF VALVE IAW MM 20-11-00 AND LEAK CHECKED GOOD.SDR UALA2013050203067Unknown · unknownLOUD FLAPPING NOISE AT L2 DOOR. INSPECTED DOOR, SEAL AND AND FRAME. NO DISCREPANCIES NOTED AND NO EVIDENCE OF ANY OBJECT FLAPPING ON THE EXTERIOR OF THE FUSELAGE. SUSPECT NOISE IS ASSOCIATED WITH BLOWN APU DUCT THAT CAUSED DEFINING NOISE IN AFT GALLEY. THE SDR UALA2013043003034Latch · wornLEFT SIDE OVERWING SLIDE DOOR HAS A WORN LATCH SLIDER. REPLACED LATCH.SDR UALA2013043003010Pawl · brokenFOUND R2 DOOR OUTSIDE SLIDE ARMING MECHANISM PAWL BROKEN. ARMING PAWL REPLACED IAW AMM.SDR UALA2013043003013Unknown · unknownVERY LOUD AIR NOISE FROM CEILING DUCTS ON RT SIDE AT THE BUSINESS GALLEY. INSPECTED MID GALLEY ZONE FOR DAMAGE ON DUCTS, NO FINDINGS. COULD NOT DUPLICATE.SDR UALA2013043003014Pump · inoperativeLEFT ELECTRIC DEMAND PUMP INOPERATIVE IN AUTO AND ON. REPLACED LEFT ELECTRIC PUMP.SDR UALA2013042602943Computer · faultedHAVE "FLAP LIMIT" SHOWING ON BOTH ADI WITH AMBER F-S INDICATION. TURNED OFF A-T, F-S INDICATION NOW INDICATING NORMAL. REPLACED TMC, CARRIED OUT TESTS ON MCDP 02 05 30 AND 40 REF MM. ALL PASSED NO FAULTS RECORDED. A-C RETURNED TO CATIII TMC IS A LUFTHANSASDR UALA2013042502880Lens · damagedSEAT 1K LOWER EMERGENCY LIGHT LENS IS DAMAGED. REPLACED LENS.SDR UALA2013043003015Blade · nickedNR 1 ENGINE FIRST STAGE FAN BLADE NICKED ON LEADING EDGE APPROX 12 INCHES FROM OUTBOARD END WITH A DEPTH OF .010. ACCOMPLISHED FIRST BLEND ON BLADE IAW AMM 72-31-02. ACCOMPLISHED HFEC AS REQUIRED REF NDT MANUAL PART 6 72-31-401. NO CRACKS FOUND.SDR UALA2013042602927Accumulator · low pressureBRAKE ACCUMULATOR PRESSURE BLED DOWN QUICKLY WITHOUT PUMPS ON. TROUBLESHOT PER FIM 32-41-00. FOUND ACCUMULATOR PRECHARGE LOW. SERVICED ACCUMULATOR PER AMM AND OPS CHECKED GOOD, NO LEAKS NOTED.SDR UALA2013042602947Shutoff Valve · seizedNR 2 ENGINE HPSOV TEST PORT FOUND SEIZED. NR 2 ENGINE HPSOV REPLACED AS PER AMM 36-11-07.SDR UALA2013042602948Controller · no testNR 2 ENGINE HPC PNEUMATIC HEALTH CHECK TEST FAILED. NR 2 ENGINE HPC REPLACED AS PER AMM.SDR UALA2013042502902Pcu · leakingLEFT HYD FLUID LOSS, FLIGHT DIVERTED. REPLACED MIDDLE RUDDER PCU DUE TO A RUNNING LEAK IAW MM. OPS CHECKED NORMAL, NO LEAKS.SDR UALA2013042402845Fairing · delaminatedRIGHT ENGINE PYLON INBD AFT FAIRING HAS DELAMINATION. PERFORMED METAL BOND REPAIR PER AMM.SDR UALA2013042402846Inlet · dentedNR 1 ENGINE INLET COWL DENTED. REPAIRED.SDR UALA2013042402847Light · inoperativeSEAT 39B EMERGENCY LIGHT INOPERATIVE. EMERGENCY LIGHT ASSY REPLACED, OPS CHECKED NORMAL IAW MM.
Back to Pratt & Whitney PW4060