Pratt & Whitney PW4090-3
Service difficulty reports · 2,638
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW40903' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW40903' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013021200836Switch · stuckNR 3 COMM PANEL TRANSMITTER SWITCH STICKS. REPLACED AMU, CHECKED OKAY.SDR UALA2013021100796Generator · warning messageLEFT BACK UP GENERATOR HAS FILTER BLOCKED INDICATION ON MAINTENANCE PAGE AT ETOPS PRE DEPARTURE CHECK. REPLACED BACKUP GENERATOR, OPS CHECKED PER AMM. TEST 3 AND FOUND OK.SDR UALA2013021100783Cover · damagedLEFT ENGINE, NR 2 HEAT SHIELD GAP COVER STRIP HAS TOTAL AREA OF EXPOSURE AFTER TRIM OUT OF DAMAGE OF .195 SQ INCH REF SRM 54-50-70 PAGE 114. L=3.125IN,G=.062IN A=.195 SQ IN. TIME LIMIT TO REPLACE DAMAGED PART IS 24 MONTHS OR SOONER. REPLACE HEAT SHIELD WITHISDR UALA2013020800770Display · failedFLT DIVERTED DUE TO LOWER DISPLAY UNIT FAILED THEN SMOKE BEGAN TO COME FROM CORNERS OF SCREEN, PER TOMC PULLED F3 CB FOR LOWER DISPLAY UNIT, SMOKE DISSIPATED, SOME RESIDUAL ODOR REMAINS. REPLACED EICAS DISPLAY SCREEN AS REQUIRED PER MM.SDR UALA2013020700743Warning Message · false activationBEFORE DEPARTURE, STATUS MESSAGE FOR HYD PUMP DEMAND C1 DISPLAYED. ACCOMPLISHED FIM 29-11 TASK 840. MESSAGE WAS LATCHED. RAN PUMP AND MESSAGE CLEARED.SDR UALA2013020700738Bolt · looseBS 1306 9G ROD ATTACH BOLTS LOOSE AT FITTINGS STR 7R AND 7L MADE DOCK WU B9029U. BOLT NUTS TORQUED TO SPECIFICATIONS IAW GPM 8-0-02-003. BOLTS REPLACED.SDR UALA2013020700740Seal · obstructedLOUD NOISE COMING FROM L1 DOOR. SOUNDS LIKE AIR LEAK. FL 330. 3 HOURS AFTER TAKE OFF. THE NOISE HEARD FROM UPPER OF L1 DOOR. CHECKED PAX ENTRY DOOR SEAL PER AMM. NO DAMAGE FOUND, REMOVED DEBRIS AND CLEANED. PRESSURIZED CABIN. NO AIR LEAK FOUND AT L1 DSDR UALA2013020700744Control Valve · failedCREW REPORTED LEFT PACK TRIPPED. RESET TWICE, NOW HAVE LEFT PACK FLOW CONTROL VALVE MESSAGE. REPLACED LT UPPER FLOW CONTROL VALVE. OPS GOOD.SDR UALA2013020700739Blanket · tornNR 2 ENGINE (222049) HYD LINE RACEWAY BLANKET IS TORN 2:00. REPLACED HEAT BLANKET.SDR UALA2013020400616Engine · surgesNR 2 ENGINE SILENT SURGE. PERFORMED TESTS IAW MM 71-00-00 P5XX, FIM 71-05 TASK 815 STEP B(1), MM 71-00-00 P5XX, FIM 71-08 TASK 828.1.2, & MM 71-00-00 P5XX. ALL TESTS PASSED. NO ENG SURGES NOTED. ACCOMPLISHED EG 7673, EG7 674 AND EG 7675, NO PROBLEMS FOSDR UALA2013020500706Card · malfunctionedLSCF ASG CARD L LEFT SYSTEMS CARD FILE (LSCF) ARINC SIGNAL GATEWAY (ASG) RIGHT (R) CARD FAILURE. STATUS MSG01- ACTIVE CRUISE HARD; ARINC SIGNAL GATEWAY (LEFT), LSCF HAS NO OUTPUT ON ANY BUSS MSG-3118801 ACTIVE ER HARD. REPLACED ASG CARD P85A12.SDR UALA2013020500717Seal · brokenWHILE RETRACTING L/E SLAT, O/B NR 1 SEAL BROKE OFF. DAMAGED SEAL REMOVED FROM LT O/B SECTION OF LEADING EDGE SLAT. REPLACED LE SLAT SEAL.SDR UALA2013020400663Engine · malfunctionedFIRST START OF NR 2 ENGINE, ENGINE EGT WAS APPROACHING 535 DEG, N2 WAS HANGING AT ABOUT 42 PERCENT, START ATTEMPT WAS ABORTED. AFTER COOL DOWN SECOND START WAS ATTEMPTED, EGT STAYED WITHIN LIMITS, BUT ENGINE HUNG WITH ERRATIC FUEL FLOW. FUEL FLOW WOULD REACHSDR UALA2013020400667Heat Exchanger · crackedNR 2 ENGINE HEAT EXCHANGER CRACKED. REMOVED NUMBER 2 ENGINE PRECOOLER PER AMM. READY FOR INSTALL. ACCOMPLISHED INSTALLATION OF NR 2 ENGINE PRECOOLER PER AMM UP TO STEP G ON PAGE 41 6.SDR UALA2013020100610Sensor · dirtyUNABLE TO CONTROL CABIN TEMP. CLEANED TEMP SENSORS AND OPS CHECKED OKAY.SDR UALA2013020100600Display · faultyDISPLAY UNIT BLANK, REPLACED CAPTAIN`S INBD DU IAW AMM, TESTED NORMAL.SDR UALA2013013100574Blade · damagedREPLACED NR 1 ENGINE DUE TO 6 HPT STAGE 1 BLADES WITH BURN THROUGH INTO THE INTERNAL CAVITY IN AREA C LESS THAN 0.125 SQ INCH REF MM 72-00-00 PG 698.73. REPLACED NR 1 ENGINE.SDR UALA2013013000557Drive Unit · failedWEATHER RADAR SYS FAILED BOTH CHANNELS. REPLACED WEATHER RADAR ANTENNA DRIVE UNIT, OPS TEST NORMAL.SDR UALA2013012900538Clamp · brokenFOUND CLEAR WATER LEAKING FROM LEFT SIDEWALL OF FWD CARGO BAY AT BS 800. FOUND Y FITTING CLAMP BROKEN ON POTABLE WATER DRAIN LINE 478W3150-108 INSIDE LEFT SIDEWALL AT STA 800. REPLACED CLAMP ASSY PCN 023-1516, SVC POTABLE WATER, OPS CHECKED NORMAL. NO LEAKISDR UALA2013012900541Hinge · damagedFOUND NR 2 ENGINE THRUST REVERSER LOWER LATCH ACCESS DOOR OPENED. REPLACED BOTH HINGE ASSY'S, ACCESS DOOR SECURELY CHECKED OKAY.SDR UALA2013013000558Oxygen Mask · unwanted deployMULTIPLE O2 MASKS DEPLOYED ROWS 37-38. SECURED 02 MASKS.SDR UALA2013012800482Satcom · faultySATCOM VOICE AND HIGH GAIN FAILURES. DUE TO THE HISTORY OF SATCOM VOICE AND HIGH GAIN FAILURES WITH CMC MSG 23-60101 AND 23-60151, REPLACED THE LEFT HIGH POWER RELAY K23001 (581-2259) IAW AMM 23-15-22 PB 401 AND THE LEFT BEAM STEERING UNIT M23090 (583-9020)SDR UALA2013012800506Gearbox · leakingFOUND TE FLAP PDU GEARBOX FLUID LEVEL EMPTY OR NEAR EMPTY. WHILE REFILLING GEARBOX FLUID FOUND LEAKING OUT WEEP HOLE AT HYD DRIVE MOTOR INPUT SHAFT. GEARBOX WILL NOT RETAIN FLUID. STARTED REMOVAL OF TE FLAP PDU GEARBOX. REMOVED ELECTRIC FLAP MOTOR ON GEARBSDR UALA2013012900539Seal · dirtyEXCESSIVE NOISE DURING CLIMB, RTFL. FOUND DEBRIS ON SEAL AT TOP FWD EDGE. CARRIED OUT CLEANING AND ADJUSTMENT OF DOOR SEAL REF MM 52-09-01 PG801. CARRIED OUT LEAK PRE AND POST ADJUSTMENT REF MM 52-09-01 PG605 PARA D ALL COMPLIANT PER TEST NO NOISE AND CABINSDR UALA2013012900542Control Valve · failedRT UPPER FLOW CONTROL STATUS MESSAGE. REPLACED UPPER FLOW CONTROL VALVE, OPS CHECKED NORMAL. MESSAGE CLEAREDSDR UALA2013012800496Smoke Detector · failedDET ZONE 1 CARGO AFT AFT CARGO COMPARTMENT SMOKE DETECTOR ZONE FAILURE. REPLACED CARGO SMOKE DETECTOR, OP CHECKED NORMAL.SDR UALA2013012200388Idg · failedRIGHT GENERATOR DRIVE DISPLAYED AFTER TAKEOFF. DISCONNECTED IDG PER FM PROCEDURES, APU ON AND POWERING BUSSES. REPLACED RT IDG PER MM, CHECKED NORMAL.SDR UALA2013012100358Metering Unit · malfunctionedWHILE DOING FUNCTIONAL TEST OF NOSE WHEEL STEERING, NOSE WHEELS TURNED LEFT AND RIGHT BUT WOULD NOT RETURN TO NEUTRAL, THEY STAYED AT 3 DEGREES TO THE RIGHT. COMPLETE NOSE LANDING GEAR SYSTEM TEST. AFTER ACFT IN HANGAR AND WARMED UP, NO PROBLEMS WERE NOTED. SDR UALA2013012200389Valve · faultyCABIN ZONE TEMP SYNOPTIC SHOWS ZONE C BLANK. F/A REPORT AREA WARM. REPLACED ZONE C TRIM AIR MODULATING VALVE, TEST PASSED ALL INDICATIONS NORMAL.SDR UALA2013012100367Module · faultyFMC R RIGHT FLIGHT MANAGEMENT COMPUTER (FMC) FAULT. FAILURE IN GUIDANCE, NAVIGATION, PERFORMANCE, OR OTHER RELATED FMC FUNCTION. STATUS MSG-3151024 LATCHD DC HARD. REPLACED CMF CORE MODULE PROCESSOR. INSTALL NEW DATA BASE UPDATES, OP CHECKS GOOD.SDR UALA2013012100365Idg · failedELECRICAL GENERATOR SYS, RT IDG HAS DISCONNECTED OR A PROTECTIVE TRIP OF THE GENERATOR CONTROL BREAKER HAS OCCURRED, OR A PROTECTIVE TRIP OF THE BTB HAS OCCURRED. STATUS MESSAGE 01- LATCHED CLIMB MODE DEPENDENT, INTEGRATED DRIVE GENERATOR (R) FREQUENCY IS LSDR UALA2013011800314Igniter · failedRIGHT ENGINE FAILED TO START ON NR 1 IGNITION . REPLACED RIGHT NR 1 IGNITOR AND EXCITER, OPS CHECKED NORMALLY.SDR UALA2013011700306Orifice · cloggedFLIGHT DECK AIR NOISY. COMPLIED WITH CHECK OF ORIFICE PLATES ALL PRESENT. WHILE RUNNING PACKS NOTICED AIRFLOW VERY LOW ON F/O SIDE. CAPTAIN`S AIRFLOW HIGH. FOUND ORIFICE CLOGGED AT CROSSOVER DUCT. CLEARED DEBRIS, ASSEMBLED, & CHECKED OK.SDR UALA2013011700291Warning Light · false activationSTATUS MESSAGE OF BLEED PRSOV LEFT. LEFT ENGINE PRSOV FOLLOWING CIRCUIT BREAKER PULLED AND RESET, ENGINE IDLE RUN CARRIED OUT AND MESSAGE CLEARED.SDR UALA2013011700292Shutoff Valve · failedBLEED PRSOV LEFT FAILED CLOSED. CHECKED ALL SENSE LINES TO & FROM PRSOV, PRSOVC AND INTERMEDIATE PRESSURE SENSOR, NO LEAKS ON LINES. FOUND LEAK ON PRSOV DEACTIVATION PLUNGER. REPLACED PRSOV PER AMM AND INTER PRESSURE SENSOR PER AMM. ACCOMPLISHED HIGH POWERSDR UALA2013011600267Module · faultyCABIN SYSTEMS CONTROL PANEL AT 1L UNABLE TO CONTROL TEMP OR LIGHTS. CSCP L1 GIVING INVALID DATA L2 CACP WORKING & CONTROLLING THE LIGHT NORMAL. REPLACED ZMU1, ALL LIGHTS CONTROLLABLE.SDR UALA2013011400242Unknown · faultyREPLACE LEFT LAV GALLEY VENT FAN FOR DF0613. -RPL LEFT LAV GALLEY VENT FAN PER MM-21-26-01 FOR DF0613 TROUBLESHOOTING. MAT TEST STILL FAILS AND LEFT LAV GALLEY VENT FAN MSG REMAINS.SDR UALA2013011400199Fuel · leakingNR 2 ENGINE FUEL LEAKING FROM STRUT DRAIN.SDR UALA2013011600268Precooler · crackedNR 2 ENGINE PRECOOLER IS CRACKED AT INBOARD TOP. REMOVED PRECOOLER. COMPLETED UP TO MM36-11 15 P415 ITEM 3.F.8. AOG Q3435 8EA WASHERS PCN 754-2661 FOR 3EA SUPPORT LINKS WASHERS FOR UNDER NUTS ON LWR END. OLD PRECOOLER DID NOT HAVE DATA PLATE. COMPLETED INSSDR UALA2013011400246Actuator · unknownTURBINE CASE COOLING ACTUATOR IS STUCK OR REVERTED TO ITS FAILSAFE POSITION. ACCOMPLISHED GROUND TEST ENGINE ACTUATOR AND PASSED.SDR UALA2013011400243Anti-Ice Valve · failedLEFT ENGINE ANTI-ICE VALVE FAILED IN CLOSED POSITION. VALVE REPLACED. PERFORMED TEST PER TASK 30-21-00-730-806-003. TESTED GOOD.SDR UALA2013011400244Button · missingRED BUTTON MISSING ON FIRE CONTROL PANEL. REPLACED RED BUTTON.SDR UALA2013011400245Controller · failedRT ENGINE ANTI- ICE VALVE WILL NOT CLOSE. CREW CYCLED SWITCH, BLEEDS AND SD RT ENGINE AND RESTARTED, NO HELP. REPACED RIGHT ENGINE ANTI-ICE CONTROLLER AND OPS CHECKED OK.SDR UALA2013011400231Wire Harness · chafedNR 2 ENGINE FIRE DETECTION SYSTEM LOOP 2 FAILED. FOUND CHAFED WIRE HARNESS BETWEEN LWR FWD AND LWR AFT LOOPS. REPLACED FIRE LOOP HARNESS AND FIRE TESTED OK.SDR UALA2013011400230Wire Harness · chafedLEFT ENGINE OVERHEAT DETECTION CIRCUIT 2 FAILED. MEASURED LEFT ENGINE LOOP 2 INDIVIDUAL ELEMENT CORE RESISTANCE AND MEGGER RESISTANCE TO GROUND, FOUND TO BE WITHIN LIMITS OF FIMMAN 26-11-810. FOUND CHAFED WIRE HARNESS AT RIGHT SIDE ENGINE, 2 FT FWD OF 'LWR ASDR UALA2013011100191Switch · failedF/O PITCH TRIM INTERMITTENT IN DOWN POSITION. CAPTAIN`S PITCH TRIM SWITCH AND ALTERNATE PITCH TRIM LEVER CONFIRMED OPERATIONAL. REPLACED PITCH TRIM SWITCH F/O SIDE CONTROL WHEEL.SDR UALA2013011100192Relay · faultedRIGHT FUEL CUTOFF SWITCH DOES NOT TRANSMITT 'OFF' TO LT AIMS. REPLACED RELAY K26206 IN P210 PANEL REF WDM 76-21-12 AND IPC 24-09-01. RIGHT ENGINE FUEL SPAR VALVE OPERATES NORMALLY.SDR UALA2013011100178Module · intermittentFIRE TEST IS NOT TESTING PROPERLY, NOT GETTING THE TEST IN PROGRESS MESSAGE ON EICAS. FIRE ENG L, FIRE ENG R, AND FIRE APU ARE DISPLAYED IN RED UPPER EICAS, INTERMITTENT. REPLACED M009 IN L AIMS REF LM5282 THEN M80001S003 FIRE-CARGO TEST SWITCH SOPM 20-11-0SDR UALA2013010900132Relay · unsecureRIGHT ENGINE SPAR VALVE WILL NOT CLOSE WHEN FUEL LEVER IS IN CUTOFF POSITION. RESEATED RELAY K76202 AND K76206 ON P210. SPAR VALVE, OPS CHECKED OKAY.SDR UALA2013010700088Wire Harness · chafedGEN DRIVE LIGHT OFF, FOUND WIRES CHAFED AT HARNESS CLAMPS ON WIRE BUNDLE DM24001C. REPLACED WIRE HARNESS.
Back to Pratt & Whitney PW4090-3