Pratt & Whitney PW4090-3
Service difficulty reports · 2,638
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW40903' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW40903' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012101705946Panel · delaminatedFOUND AFT FAIRING PANEL P/N 149W5231-1 WITH TWO INCH DELAM DURING WALK AROUND INSPECTION. ROUTED TO SHOP FOR REPAIR. REMOVED AND INSTALLED AFT FAIRING PANEL P/N 149W5231-1.SDR UALA2012101705928Circuit Card · unsecureELMS P210 PANEL THE ELECTRICAL LOAD MANAGEMENT SYSTEM (ELMS) P210 PANEL IS FAULTED SUCH THAT IT CANNOT SUPPORT AIRPLANE DISPATCH. AIMS HAS LOTS ARINC 629 COMMUNICATION WITH THE P210 PANEL. OR ONE P210 PANEL CHANNEL IS LOST AND THE OTHER FAULTED AND IS OPERATISDR UALA2012101705929Strip · crackedRIGHT PYLON AFT FAIRING HEAT SHIELD GAP COVER STRIP NR 2 HAS FOUR CRACKS AT OUTBOARD EDGES OF PREVIOUS REPAIRS. FOUND CRACK IN E2 HEATSHIELD GAP STRIP. STRIP HAS BEEN CUTOUT AND MEASUREMENTS TAKEN. REPLACED THE SUBJECT GAP COVER STRIP WITH NEW PER ECRA 5454SDR UALA2012101505846Bulb · inoperativeEMERGENCY EXIT SIGN ON AISLE NEAR R2 DOOR, GALLEY, ONE BULB INOPERATIVE. REPLACED BULB AND OPS CHECKED OKAY PER MM.SDR UALA2012101605906Computer · malfunctionedAIMS 1) EITHER ONE (1) OR MORE OF THE SAFEBUS (TM) LANES HAS FAILED OR ONE (1) OR MORE OF THE POWER INPUT CHANNELS TO THE AIMS HAS FAILED FOR 1 SECOND OR 2) INCOMPATIBLE OPS, OPCS, OR PROGRAM PINS EXIST BETWEEN LEFT AND RIGHT CABINETS AT UNINHIBITED COLD POWERSDR UALA2012101505882Clamp · leakingRIGHT PACK UPPER FLOW CONTROL VALVE LEAKING AT V-BAND CLAMP. REPLACED V-BAND CLAMP, NO LEAKAGE NOTED.SDR UALA2012101505883Display · inoperativeCAPTAINS OUTBOARD DISPLAY UNIT IS INOPERATIVE. REPLACED CAPTAINS OUTBOARD DISPLAY UNIT PER AMM, OPS CHECK PASSED.SDR UALA2012101505845Light · inoperativeECON GALLEY WIRES STICKING OUT FROM FWD WALL AT FLOOR LEVEL. FLOOR PROX EMERGENCY PATH MARKING LIGHT AT DOOR 4R ON SIDE WALL OF MOST FWD GALLEY INOP. TAPE WIRES UP WILL REQUIRE NEW SOCKET. REPLACED EMERGENCY LIGHT. OP CHECKS NORMAL.SDR UALA2012101205824Precooler · rupturedNR 2 ENGINE PRECOOLER, FOUND BOTTOM CORE RUPTURED AND CAUSING DAMAGE TO REVERSER HEAT BLANKETS. BEGAN REMOVING PRECOOLER. REMOVED PRSOV, PRSOV CONTROL PRESSURE SENSE LINE, AND 8TH STAGE THRUST BALANCE DUCT.SDR UALA2012101505869Actuator · faultyTURB CASE COOL HPT R RIGHT ENGINE HIGH PRESSURE TURBINE (HPT) CASE COOLING ACTUATOR IS STUCK OR REVERTED TO ITS FAIL-SAFE POSITION. STATUS MSG-7560682 INACTV DC INTER MSG-7560662 ACTIVE DC HARD MSG-7550662 INACTV DC MODE MSG-7550662 INACTV DC MODE MSG-7550SDR UALA2012101105797Module · faultyFMC L EICAS MESSAGE-CPM ACMF LEFT AIMS HAS NO OUTPUT. REPLACED CPM-ACMF IN LEFT AIMS CABINET TROUBLESHOOTING CONTINUES.SDR UALA2012101005764Generator · faultyAPU GENERATOR FAIL LIGHT, WHEN RESET APU SHUTDOWN NO APU GEN RESET. FOUND MAINTENANCE MESSAGE 24-31513, APU GENERATOR EXCITER FIELD OPEN CIRCUIT.SDR UALA2012100805702Unknown · malfunctionedSTATUS MSG PASS ADDRESS. UNABLE TO DUPLICATE PROBLEM AND NO ACTIVE FAULTS NOTED. DUE TO HIS WITH MSG 23-03249, REPLACED M23040 PRECAUTIONARY. ACP CABIN PROGRAMMING, SYSTEM TESTED NORMAL.SDR UALA2012100805667Exciter · failedENGINE IGNITOR L2 LEFT ENGINE FAILED TO IGNITE USING IGNITOR 2. FAILED AUDIBLE TEST PER MM, NO POP. REPLACED IGNITION EXCITER IGNITION LEAD AND IGNITION PLUG AND ACCOMPLISHED IGNITION SYSTEM, OPERATIONAL CHECK BOTH L1 AND L2 FUNCTIONED NORMAL.SDR UALA2012100905714Rub Strip · damagedAFT CARGO THIRD CEILING RUB STRIP FROM FRONT DAMAGED ADJACENT DOOR ENTRY. SIX INCH DAMAGED END SECTION REMOVED AND CEILING RUB STRIP REFITTED WITH INTERIM TAPE REPAIR MADE. LAST TWO FASTENER THREAD INSERTS WILL ALSO REQUIRE REPLACEMENT. REPLACED BROKEN STANSDR UALA2012100405638Unknown · odorSMELL EMANATING FROM LEFT PACK SMELL IS IN THE REAR OF THE AC AND COCKPIT. NO SMELL IN MID AND FIRST CLASS. IT IS 1HOUR AND 52 MIN SINCE T/O. THE SMELL IS COMING FROM THE LEFT PACK, WITH LEFT PACK OFF SMELL DISSIPATED. ITEM ROLLED FORWARD. POWER AT IDLE, SDR UALA2012100305608Light · looseSEAT 3F ARMREST EMERGENCY LIGHT LOOSE. SECURED LIGHT ASSY OK.SDR UALA2012100305622Generator · faultySTATUS MESSAGE ELEC BACKUP GENERATOR L AFTER SHUTDOWN. CYCLED BACKUP GENERATOR SWITCH, RAN ENGINE, BUG OPERATED NORMALLY MSG RETURNED AFTER SHUTDOWN. REPLACED LEFT ENGINE BACK UP GENERATOR.SDR UALA2012100305621Start Valve · faultyAPU AIR START VALVE CYCLES OFF AND ON WITH THE APU RUNNING AND APU BLEED VALVE OFF. THIS SHOWS ON THE AIR PAGE. REPLACED STARTER VALVE REF NEEDS OPS AND LEAK CHECKS. ACP OPS CHECK, NO LEAKS NOTED.SDR UALA2012100205582Control Valve · faultyRIGHT LOWER FCV FAULTS. DUE TO RECENT HISTORY OF RIGHT PACK LOWER FLOW CONTROL VALVE INOP IN FLIGHT, REPLACE LOWER FLOW CONTROL VALVE (PCN 646-9007) RIGHT PACK PER MM. VERIFY PART NUMBER IN IPC PRIOR TO CHANGING. REPLACED RIGHT LOWER CONTROL VALVE PER AMM.SDR UALA2012100205584Controller · faultyCABIN INTER BUSY SIGNAL HEARD ON COCKPIT HANDSET UNABLE TO CONTACT CABIN. REPLACED PACI PER MM, OPN CHECKED OK.SDR UALA2012100405625Clamp · brokenCLAMP BROKEN ON AFT END OF LOWER FCV ON RIGHT PACK. INTERIM REPAIRED PER ECRA 2151-01134 INSTALLED CLAMP 160-0143, OPS AND LEAK CHECKED PER MM. INSTALLED NEW CLAMP AFT END OF LOWER FCV ON RIGHT PACK.SDR UALA2012100205588Skin · bentDOOR 4R FWD LOWER EDGE BENT IN APPROX .075 IN DEPTH 1.5 IN WIDE APPROX 9 INCHES IN LENGTH LOCATED 10 INCHES BACK FROM FWD LOWER CORNER. PERFORMED EDDY CURRENT INSPECTION TO LOWER SKIN AND FASTENER HOLES THAT WERE REMOVED PER NTM PART 6 51-00-01 AND NTM PART 6SDR UALA2012100205574Precooler · leakingNR 2 ENGINE PRECOOLER LEAKING AT AFT LOWER SEAM. REMOVED PRECOOLER TO STEP 5 (INSTALLATION). INSTALLED PRECOOLER PER AMM. PRSOV REMOVED, ADDITIONAL DUCT REMOVED FROM OUTBOARD SIDE. REPLACED NR 2 STRUT PRECOOLER.SDR UALA2012092705454Warning System · false activationEICAS MESSAGE DETECTOR FAN 1 CARGO FORWARD SHOWED AT DEP. MAINT MESSAGE 26-21041 MAT TEST FAIL PER FIM 26-16 TASK 803. MSG DET FAN 1 CGO FWD NOT DISPLAYED ON EICAS, NO EXISTING OR INBD FLIGHT FAULTS. ACCOMPLISHED GROUND TEST 26 CARGO SMOKE DET SYS TEST PER SDR UALA2012092505435Controller · inoperativeLEFT MANIFOLD PRESSURE - FLOW SENSING SYSTEM INOPERATIVE. SAMC TEXT: FLIGHT CREW COMPLIED WITH MEL. OPBLM DEFERRED PER SAMC. REPLACED LEFT ASCPC PER MM, OPS CHECK NORMAL PER MAT.SDR UALA2012092705456Bellows · tornODOR IN THE CABIN-FD. DUE TO HISTORY OF ODOR IN THE CABIN-FD. REPLACED TORN BELLOW ON FLEXIBLE SURGE DUCT. REF AMM FOR VALVE REMOVED AND REPLACED. REMOVED APU SOV & INSPECTED UPSTREAM & DOWNSTREAM OF VALVE. NO OIL CONTAMINATION NOTED, DUCT CLEAN. RE-INSTSDR UALA2012092705455Unknown · vibrationHUMMING AND VIBRATION COMING FROM DOOR 3L. INSPECTED AREA, NO OVERHEAT, OR LEAKS, HUMMING VARIES WITH APU PNEUMATICS OFF OR WHEN PACKS ARE TURNED ON. SUSPECT AIR PRESSURE BUILDUP IN DUCTS WHEN NO DEMAND CALLED FOR. THIS IS A KNOW CONDITION. INSPECTED PAX ANSDR UALA2012092405418Unknown · malfunctionedFLAPERON ACT STATUS: MSG 27-10302 ACTIVE & LATCHED. ACP'D FIM 27-11 TASK 816 STEP C. FOUND WIRE CHECKS GOOD. REF STEP C.(3), REPLACED ACE-L2 (M2712 2) PER MM27-02-02. LRU REPLACEMENT TEST CHECKS OK BUT FLAPERON POSITION SYSTEM TEST FAILS WITH MSG 27-16039,SDR UALA2012092405419Pcu · faultyFLAPERON ACTUATOR STATUS MSG-REPEAT. REPLACE RIGHT INBOARD FLAPERON PCU PER AMM. SYSTEM OPS CHECK NORMAL.SDR UALA2012092405385Skin · delaminatedON WALK AROUND FOUND POSSIBLE DELAMINATION ON RIGHT SIDE OF VERT STAB. ITEM ROLLED FORWARD. REF IPC55-34-51-008, PANEL HAS 11 BY 8 AREA OF DELAM IN MIDDLE OF PANEL. REF SRM 55-30-01. NEED TO ACP INTERIM REPAIR PER ECRA 5530-01666 AVAILABLE ON EDOCS. ACCOSDR UALA2012092405420Control Panel · faultyAUDIO CONTROL PANEL PROBLEM. SWAPPED 1ST OFFICER WITH 1ST OBS PANEL. F/O PANEL OP CHECK OK. 1ST OBSERVERS PANEL RECEIVES NR 2 VHF BUT CAN`T TRANSMIT. F`O'S SYSTEM, OP CHECK OK. CAPTAINS AUDIO SYSTEM FUNCTIONS NORMALLY. SHOULD BE SEC OBSERVERS. REPLACE ASDR UALA2012092405409Computer · faultyRIGHT MFQ BLANKING. DUE TO REPEAT REPORTS OF RT MFQ INDICATION BLANKING AND BOEING AHM DOWNLOADING MAINTENANCE MESSAGES 24-11111 AND 24-12250 ACCOMPLISH FIM 28-41 TASK 801. IF NO FAULTS FOUND REPLACE FQPU C-I483-9211 PRECAUTIONARY. REPLACED FQTY PROCESSOR, SDR UALA2012092005340Unknown · odorACRID SMELL IN COCKPIT GOING THRU 14000 DESCENT. ON ARRIVAL NO SMELL IN CABIN , NOR COCKPIT. NO MSG FOUND. ACPD FAULT ISOLATION PROCEDURE PER FIM 21-00 TASKS 808 FOUND ALL NORMAL. NO EVIDENCE OF BIRD STRIKE ON BOTH ENGINE. RUN APU AND PACKS FOR ONE HOUR NSDR UALA2012092005326Probe · faultyCENTER TANK FUEL QTY INDICATION WAS READING 103.7 AT PUSHBACK, DURING TAXI QTY DROPPED TO 94.8. NEED TO DRIP CENTER TANK AND VERIFY CENTER TANK QTY FOUND CTR TANK QTY READING BELOW DIP STICK READING BY APPX 1200 LBS. CTR TANK GAUGE CONSIDERED INOP. REFUELED ACSDR UALA2012091905296Apu · making metalAPU CONTROL STATUS MSG. LATCHED FAULT MSG 49-12990. FIM TASK 49-20-813 - CHECKED CHIP DETECTORS PER AMM 49-27-04 AND FOUND LARGE QUANTITY OF PARTICLES ON OIL SUMP DETECTOR AND SMALL (FUZZ) ON TURBINE BEARING SCAVENGE DETECTOR. COMPLETED APU INSTALLATION PERSDR UALA2012092105362Battery · faultyMAIN BATTERY STATUS MESSAGE IS DISPLAYED. REPLACED AND TESTED BATTERY PER MM, TESTS GOOD.SDR UALA2012092105363Charger · faultyBATTERY CHARGER STATUS MESSAGE IS DISPLAYED. REPLACED AND TESTED CHARGER PER MM, TESTS GOOD.SDR UALA2012091905313Start Valve · faultyENGINE START VALVE R ON START WITH NO ROTATION. REPLACED START VALVE ON RT ENGINE DRY MOTORED ENG ALL IND NORMAL REF JRH & MM71-00 & REF SMC08.SDR UALA2012091905312Shutoff Valve · failedTRIM AIR PRSOV LEFT TRIM AIR PRESSURE RELIEF SHUT OFF VALVE (PRSOV) FAILED. REPLACED LEFT TRIM AIR PRSOV PER MM, OPS CHECK NORMAL, NO MESSAGE.SDR UALA2012091905286Panel · wornNR 1 PYLON LEFT SIDE WORN ON INNER SURFACE OF PANEL 433CL CUTOUT. REPAIRED IAW ECRA 5431-01061.SDR UALA2012091905287Panel · wornNR 2 PYLON LEFT SIDE WORN ON INNER SURFACE OF PANEL 443CL CUTOUT. REPAIRED IAW ECRA 5431-01061.SDR UALA2012091905300Duct · brokenFLEXIBLE DUCT OF THE APU SURGE DUCT ASSY FOUND WITH BELLOWS BROKEN OFF. REPLACED FLEX DUCTSDR UALA2012091405200Hinge · out of adjust1K CONSOLE LOCK INOP, FOUND SIDE COMP'T DOOR WILL NOT OPEN. REPLACED LATCH. STILL NO HELP. NEED MORE TIME TO ADJUST DOOR HINGE. VERIFIED COMP'T IS EMPTY AND DOOR SECURED CLOSE.SDR UALA2012091305183Idg · malfunctionedON ARRIVAL CHECK FOUND MAINTENANCE PAGE CHAPTER 24 RIGHT ENGINE OIL FILTER BLOCKED. FOUND RIGHT ENGINE IDG INOP. DEFER PER MEL, PER MEL REQUIRED DISCONNECTED RIGHT ENGINE IDG AND SERVICED IDG. IDG DELTA P INDICATOR WAS EXTENDED. THE IDG WILL NEED TO BE REPSDR UALA2012091405199Fan · faultySMOKE SMELL NEAR DOOR 3L. TURNED OFF UPPER RECIRC. AFTER SELECTING UPPER RECIRC FAN SWITCH OFF CREW WAITED TO REE VALUATE AND REPORTS ODOR HAS CLEARED. ELECTRICAL TYPE ODOR NO VISIBLE SMOKE, CONCENTRATED NEAR DOOR 3L-3R AREA. FOUND C-B B5 AT P210 POPPED AFSDR UALA2012091305181Sdu · faultySATCOM SYSTEM STATUS MSG. CHECKED MAT AND FOUND MAINT MSGS OF 23-69951 AND 23-68801. BOTHS FIM PROCEDURES REQUEST FOR SDU REPLACEMENT ON THE FIRST STEP. SDU PCN 583-9200 NIL AT GRUJL. CBS E17, E20 AND E21 PULLED OUT AND COLLARED PER MEL PROCEDURES. REPLACESDR UALA2012091305184Probe · faultyDURING REFUELING FOUND RIGHT MAIN FUEL TANK QTY INDICATION INTERMITTENT BETWEEN 40,000 TO 57,000 LBS. DRIPSTICK READING CARRIED OUT. FUEL QTY MAINT PAGE SHOW TANK UNIT RIGHT MAIN 11, 12, 13 SHOW 0.0-0.8. TANK UNIT, PCN 483-0030 EXPEDITED. REPLACED FQPU, NOSDR UALA2012091105098Unknown · malfunctionedCENTER TANK RT REFUEL VALVE ACTUATOR CLOSED DURING REFUELING. DF FOR BASE ACTION. -INF- :TRIED NEW IRP NO HELP. RE-INSTALLED OLD IRP, NEEDS MORE TROUBLESHOOTING. REPLACED REFUEL VALVE CONTROL UNIT, NO HELP.SDR UALA2012091205146Battery · faultyAPU BATTERY STATUS MSG. NO TIME FOR TROUBLESHOOTING. MEL APPLIED. REPLACED APU BATTERY, REF AMM. CHECKED OKAY.
Back to Pratt & Whitney PW4090-3