Pratt & Whitney PW4090-3
Service difficulty reports · 2,638
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW40903' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'PW40903' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012112606783Actuator · malfunctionedMAIN GEAR STEERING EITHER MAIN GEAR AFT AXLE IS MANUALLY DISABLED, IS NOT RESPONDING TO COMMANDS, OR LOSS OF ARINC 629 BUSS INPUT FROM MAIN GEAR STEERING CONTROL UNIT. STATUS MSG-3263010 LATCHD AP MODE. DEFERRED PER MEL. MAIN GEAR STEERING ACTUATORS ARE VERSDR UALA2012111906681Lug · brokenLUG TO LWR AFT FIRE LOOP BROKEN ON O/B SIDE OF NR 2 ENGINE. REPLACED BOTH LOWER AFT ENGINE FIRE DETECTORS, OPS CHECKED NORMAL.SDR UALA2012111906682Fire Loop · inoperativeON ARRIVAL FIRE LOOP 1 ENGINE R STATUS MESSAGE CHECK MAT ACTIVE. DF 0606 RIGHT ENGINE FIRE LOOP 1 INOPERATIVE. COMPLIED WITH MEL REQUIREMENTS. REPLACED BOTH RIGHT ENGINE LOWER AFT FIRE DETECTIVE ELEMENTS, OPS CHECKED NORMAL PER MM.SDR UALA2012112006693Latch · brokenFWD CARGO DOOR CONTROL PANEL 1 EA LATCH BROKEN. REPLACED FWD CARGO CONTROL DOOR LOWER LATCH.SDR UALA2012111906683Fire Detector · faultyON ARRIVAL OVERHEAT CIRCUIT R1 STATUS MESSAGE. REPLACED BOTH RIGHT ENG LOWER AFT FIRE DET ELEMENTS, OPS CK NORMAL.SDR UALA2012111606584Static Wick · damagedFOUND LIGHTNING DAMAGE TO WICK BASE. FOUND LIGHTNING STRIKE ON UPPER TWO INCHES OF RUDDER. TOP STATIC WICK MISSING, AND DAMAGE TO BASE. SEE TOCS. PER AMM, NEED TO ACP ITEM D(2) STATIC DISCHARGER RESISTANCE CHECK. REPLACED STATIC DISCHARGER & ASSOCIATED BASDR UALA2012111606585Coupler · defectiveRIGHT HF COMM SYSTEM INOP. NEED TO REPLACE RIGHT HF TRANSCEIVER AND ANT COUPLER. COMPLIED WITH MEL. GOT MSG 23-51012 & 23-51002, REPLACED R TRANSCEIVER PER MM, NO HELP. SAME FAULT MSG 23-51012 WITH ALL DASHES IN THE TUNING PANEL, INSTALLED OLD TRANSCEIVER SDR UALA2012111906685Door · out of adjustUPON ARRIVAL AT GATE, FOUND EXTERNAL POWER DOOR FWD EDGE PROTUDING INTO AIRSTREAM. ADJUSTED EXT POWER DOOR. OPS CHECKED OK FOR SERVICE.SDR UALA2012111906641Display · malfunctionedCENTER CDU FAIL, EICAS MESSAGE AND CDU BLANK. REPLACED CENTER CDU.SDR UALA2012111406547Fseu · faultyFLAP SLAT CONTROL 2 STATUS MSG. MAINT MSG 27-28852. RESET CB FSCU PRI P310 D-2, FSCU ALT P210 L-13 AND SNSR EXC 2 P210 F-21, NO HELP. REPLACED FSEU2 PER AMM 27 -51-01 PAGE 401. MESSAGE CLEARED.SDR UALA2012111406548Chiller · noisyM11 FIRST CLASS CHILLER NOISY. VIBRATES ENTIRE GALLEY AND LAV AREA. REPLACED C11 CHILLER PER AMM.SDR UALA2012111406545Sealant · inadequateNOISE-SQUEAL AT DOOR 4L. REMOVED MID AND AFT SCUFF PLATE SECTIONS AT DOOR 4L PER AMM AND CLEANED AREA. FOUND INSUFFICIENT AMOUNT OF SEALANT APPLIED. INSTALLED MID AND AFT SCUFF PLATE. NEED TO LEAK CHECK DOOR 4 LT SILL AREA WHEN SEALANT IS DRY SEALANT APPLISDR UALA2012111206506Circuit Card · faulty"ELMS P110 CHANNEL" STATUS MSG APPEARED AFTER BRAKES RELEASED. MSG CLEARED AFTER EU SELF TEST BUT RE-APPEARED AGAIN. SEE PREVIOUS. SUSPECT P110 629 CARD M24400A3, REPLACED MODULE M24 400A3. NO HELP. 629 CARD L IN P110 IS INCOMPATIBLE WITH ELMS P110 CPU CHSDR UALA2012110906451Connector · dirtyDURING REFUELING FOUND SLOW RATE ON CTR TK. FOUND LEFT CTR REFUEL VLV NOT OPEN MANUALLY OPENED AND CONNECTOR CLEANED THEN FUNCTION AUTO NORMAL AGAIN AUTO REFUEL ACP AND SATISFACTORY.SDR UALA2012111206494Shutoff Valve · faultyLEFT WING HYDRAULIC ISOLATION VALVE DOES NOT INDICATE CLOSED WHEN SWITCH IN SHUTOFF POSITION. DEACTIVATED OPEN. REPLACED LEFT HYDRAULIC SYSTEM WING SHUTOFF VLV REF MM. NO LEAKS NOTED AND VLV TEST OK.SDR UALA2012110906446Wire · damagedSTATUS MSG OVERHEAT CIRCUIT R2. FOUND WIRES W0656-1001R-16 AND W0656-1002R-16 FROM M26005 LWR AFT DETECTOR TO M26004 LOWER FWD WITH DAMAGED INSULATION BENEATH CLAMPS BEHIND EDP HYDRAULIC SUPPLY LINE HEATSHIELD AT THE 3 O'CLOCK POSITION. REPROTECTED INSULATIOSDR UALA2012110906447Wire Harness · damagedNR 2 ENGINE RIGHT STATUS MESSAGE. FOUND WIRES W0656-1001R-16 AND W0656-1002R-16 FROM M26005 LOWER AFT FIRE DETECTOR TO M26004 LOWER FORWARD WITH DAMAGED INSULATION BENEATH CLAMPS BEHIND EDP HYDRAULIC SUPPLY LINE HEATSHIELD AT 3 O'CLOCK POSITION. REPLACED FIRSDR UALA2012111206495Module · failedLEFT AIMS CPM-ACMF (M002) FAILED. REPLACED CORE PROCESSOR MODULE M002 LEFT AIMS AND LOADED SOFTWARE PER MM. ALSO ACP MACH BIAS MOD PROCEDURE PER MM. OPS CHECKS NORMAL. NO FAULT MESSAGE.SDR UALA2012110906459Precooler · blownFOUND NR 1 ENGINE PRECOOLER BLOWN. IT DAMAGED MULTIPLE HEAT BLANKETS ON SAME ENGINE REVERSER. NR 1 ENGINE PRECOOLER LEAKING. REMOVED NR 1 ENGINE PRECOOLER PER MM. NEW PRECOOLER IN AREA. REPLACED PRECOOLER ASSY.SDR UALA2012110806420Circuit Card · faultyON GROUND FOUND STATUS MSG "FIRE CARD ENG R" DISPLAYED ON EICAS. REPLACED R-ENGINE FIRE DET CARD P84A10, STATUS MSG EXTINGUISHED AND FIRE TEST NORMAL.SDR UALA2012110706387Wire · chafedRIGHT ENGINE FIRE LOOP 2 STATUS MESSAGE. FIRE LOOP 2 RIGHT ENGINE - FOUND WIRES W0656-1001R-16 CHAFED THROUGH SHIELD TO CENTER CONDUCTOR AND W0656-1002R-16 CHAFED THROUGH TO SHIELD. NEEDS APPROX 30FT OF BMS13-55T4C1G16. REF IPC71-00-01-751C ITEM 120 PCN 566SDR UALA2012110706406Weu · faultyCONFIG PARKING BRAKE PARKING BRAKE SET AND TAKEOFF THRUST SELECTED ON ENGINE LT OR RT WARNING. CREW COMMENTS: INTERMITTENT. REPLACED LEFT WEU PER MM, CONFIRMED OPS AND OPC. WEU AND STALL WARNING GRD TEST PASSED. NO MSG. INSTALLED JAL NON-POOL PART, P/N 28SDR UALA2012110706416Skin · damagedSTATIC DISCHARGE FROM LEFT FRONT OF A-C. REMOVED 12 EACH OF FASTENERS ON LEFT NOSE EXTERNAL SKIN IN SECTION 41. PERFORMED HFEC CHECK OK. INSTALLED SOLID FASTENERS FOR PERMANENT REPAIR PER ECRA#: 5310-05609.SDR UALA2012110506318Slide · brokenNR 1 RIGHT PAX ENTRY DOOR SLIDE LATCH HANDLE BROKEN. REPLACED WITH NEW SLIDE PER TC#228414510.SDR UALA2012110606366Unknown · malfunctionedAPU APUC DETECTED FAULT THAT WOULD CAUSE AUTOMATIC SHUTDOWN OF APU IN UNATTENDED MODE OPERATION, OR COMPLETE LOSS OF APUC BUS ACTIVITY (BOTH L AND R 629) FOR 3 SECONDS AFTER THE APU MASTER CONTROL SWITCH HAS BEEN IN THE ON POSITION FOR TEN SECONDS. FAULT CAMESDR UALA2012110506316Lamp · inoperativeFWD LIGHTS IN AFT CARGO CMPT ABOVE LLAR ARE INOP. FOUND 4 EA LIGHTS OUT DURING COMPLETION OF EG7521 FCD 3330-01031 INOPED PER MEL. REPLACED LAMPS, OPS GOOD.SDR UALA2012110506356Light · improper partPER FCD#3330-01031 FOUND INCORRECT HALOGEN BULBS P/N 9203 INSTALLED AT ALL 4 POSITIONS AND MAINT TEXT: MANDATORY PLACARDS MISSING ABOVE LLAR STA1466 AND STA 1522. ACP FCD 330-01031 PER EG 7521. RELAMPED BULBS AND ADDED PLACARDS.SDR UALA2012110506335Wire Harness · faultySENSOR EXC 1 CB TRIPPING ON P310 PANEL. REPLACED WIRE HARNESS FROM D2181P TO SKEW SENSOR M27325 AND CHECKED OKAY.SDR UALA2012110506350Shutoff Valve · faultyCARGO HEAT VALVE AFT FAILURE OF AFT CARGO HEAT SHUTOFF VALVE OR (SOV) OR TEMP CONTROL VALVE (TCV). STATUS MSG-2112031 INACTV ER MODE MSG-2112021 INACTV DC MODE. COMPLIED WITH MEL PROCEDURE AND MAINT ACTION CARRIED OUT. PSBL VLV (PCN 646-0013), EXPEDITED ON SDR UALA2012110506351Inverter · faultyNO LAND 3 EICAS ON FINAL AT APPROX 1500 AGL. REPLACED STATIC INVERTER PER MM. (ACTION). REPLACED STATIC INVERTER PER MM. AIRCRAFT IS IN CAT 111 STATUS.SDR UALA2012110206298Slide · unserviceableTHE NR 4 LEFT PAX ENTRY DOOR SLIDE PACK INFLATION CYLINDER SAFTY PIN FITTING WAS NOT INSTALLED. REPLACED WITH NEW SLIDE.SDR UALA2012110206301Structure · wornNR 2 PYLON ACCESS PNL 443CL CUTOUT WORN IN 4 SPOTS BLENDED AND PAINTED ON DOCK WU Q7142E REQUIRES REINSPECTION FOR NEW WEAR EVERY 30 DAYS AND MUST BE PERMANENTLY REPAIRED BY 3-23-2013 PER UA EVA 80711. FOUND ADDITIONAL ABRASION ON TITANIUM TRIPLER. BLENDED OSDR UALA2012103006249Cable · out of rigNO WATER PSI ON A-C CHRONIC PROBLEM. PER MEL PLACARD 38008 ENSURE POV IS CLOSED. COMPLIED WITH REQUIREMENTS IN MEL 3810AR. ADJ- :ADJUSTED RIG OF PRESELECT OVERFLOW VALVE CABLE, OPERATION CHECK NORMAL. WATER PRESSURE NORMAL IN ALL LAVS AND GALLEY.SDR UALA2012103006247Fastener · looseFLIGHT CREW REST AREA DOOR LOCK UNABLE TO OPEN FROM OUTSIDE. NOT TO BE USED. DOOR LOCK IS INOP CANNOT UNLOCK FROM OUTSIDE. INF- :.PCN 023-1395 OR 023-1394 OUT OF STOCK AT ORD. SECURED LOOSE HARDWARE, OPS CHECK GOOD.SDR UALA2012102906176Light · inoperativeRIGHT FORWARD INBOARD POSITION LIGHT INOP. NO TIME. REPLACED LAMP IAW MM, OPS CHECKS NORMAL.SDR UALA2012102906221Audio Panel · faultyCAPT AUDIO PANEL, NO GREEN LIGHT ON ADF, WHEN TESTED AND SELECTED. REPLACED AUDIO PANEL PCN 583-0010 ONLINE IPC 11-31-00-0051 REF; MM 23-51-01 PG 401 OP GOOD REF; MM 23- 51-01 PG 401.SDR UALA2012102906232Housing · missingLEFT PACK FAN INLET DIFFUSER HOUSING SUPPORT BRACKET EXITED PACK EXHAUST. REPLACED DIFFUSER HOUSING PER MM, OPS CHECK NORMAL AND LEAK CHECK OK.SDR UALA2012102606145Module · faultyELMS P110 CHANNEL ONE, BUT NOT BOTH, OF THE ELECTRICAL LOAD MANAGEMENT SYSTEM (ELMS) P110 PANEL CHANNELS ARE FAULT-DUE TO DF564 ON CHA A. SWAPED 629 CARD BETWEEN CHANNEL A AND B WITH FAULT FOLLOWS, RETURNED CARD TO ORIGINAL, REPLACED A3 CARD WITH ROBBED CARD SDR UALA2012102906220Rfu · malfunctionedDATALINK LOST NO DATA LINKS ESTABLISHED (HF, VHF, SATCOM MODES DATALINKS LOST) ADVISORY CREW COMMENTS: OCCURRED 10+ TIMES IN 4 HOURS OF FLIGHT. REPLACED RADIO FREQUENCY UNIT REF: FIM 23-15 TASK 802 PCN 580-9105. REF; MM 23-15-11 PG 401, OPS CHECK GOOD.SDR UALA2012102606147Probe · faultyFUEL QTY INDICATION FUEL TANK QUANTITY ACCURACY IS UNACCEPTABLE. STATUS CREW COMMENTS: RT MAIN TANK FUEL QTY INDICATOR BLANK. MAINT TEXT: HITTING RT TANK PROBES NR 16 M28061 483-0044 MSG 28-2 0121 & NR 18 M28063 483-0046 MSG 28-20125. NEEDS 4 SHIFT SLOT FSDR UALA2012102606152Strut · leakingAIR LEAKAGE WAS FOUND WHEN SERVICING RIGHT MLG SHOCK STRUT REQUIRING THE REPLACEMENT OF THE STRUT. REQUIRES THE REPLACEMENT OF THE STRUT, MR62391. NON ROUTINE GFS 0308892 HAS BEEN CREATED. STRUT ASSEMBLY MR62391-17TEW HAS BEEN REMOVED AND INCLUDES OUTER CYLSDR UALA2012102906171Battery Pack · faultyON TAXI OUT F/A REPORT EMERGENCY EXIT PATH LIGHTS ILLUMINATED ON THE SEATS FROM ROW 19 TO DOOR 3R. CRW CYCLED SWITCH ON OVERHEAD AND F/A PANELS, NO HELP. CYCLED C/B'S ON OVERHEAD H9-11 & H16-18 LIGHTS EXTINGUISHED AND NOW DO NOT COME ON WITH FLT DECK SWITCH SDR UALA2012102906227Unknown · leakingLEFT ENGINE HAS A RUNNING LEAK WITH FUEL EXITING THE NR 9 STRUT DRAIN. FOLLOWING LEAK DETECTION TROUBLESHOOTING FOUND LEAK HAD STOPPED FROM NR 9 STRUT DRAIN. DRY MOTOR CARRIED OUT STILL NO LEAK EVIDENT 2 WET MOTOR RUNS CARRIED OUT AGAIN NO LEAK NOTED AFTER FSDR UALA2012102606156Valve · faultyLEFT TRIM AIR PRSOV STATUS MSG WITH TRIM AIR L EICAS MSG. LEFT TRIM AIR PRSOV LOCKED IN CLOSED POSITION PER MEL. ACP'D REPLACEMENT OF VALVE.SDR UALA2012102506121Spar · corrodedLEFT WING REAR SPAR WEB CORRODED AROUND FASTENERS IN THE AREA OF IRSS 347 WHERE FUEL BOOST PUMP IS INSTALLED. DAMAGE REPAIRED IAW ECRA 5720-02325.SDR UALA2012102506134Control Valve · faultyFLAP-SLAT CONTROL 1 HIGH LIFT CONTROL LANE NR 1 HAS A FAULT. STATUS MSG01- LATCHED DESCENT MODE DEPENDENT; SLATS PRIMARY SHUTOFF SOLENOID CIRCUIT IS OPEN. DB- FSEU 1 MSG-2721011 LATCHD DC MODE. FLAP SLAT CONT 1 MESSAGE. REPLACED PRIMARY SHUTOFF SOLENOIDSDR UALA2012102506129Control Valve · faultyAPU BLEED STATUS AT THE GATE. REPLACED APU SURGE CONTROL VALVE PER MM, OPS NORMAL.SDR UALA2012102206013Door · damagedTHE 2F LIFE VEST DOOR DAMAGED. REPAIRED DOOR.SDR UALA2012101905986Oven · contaminated19HJK REPORT OF STRONG ELECTRICAL OR PLASTIC BURNING SMELL. PER CREW REPORT, UNABLE TO PINPOINT CAUSE OF ODOR VARIOUS COMPLAINTS WERE BODY ODOR, TOBACCO, PLASTIC SMELL. ALSO NOTICED BY POSITION DOOR 1L. CREW INDICATES NO SMOKE OR FIRE HAZARD. REQUEST SFOMMSDR UALA2012101705938Overheat Loop · failedBLEED LOOP 2 BODY FAILURE. REPLACED LOOP, TESTED OK.
Back to Pratt & Whitney PW4090-3