20160130024079I

Incident · No damage

FAA incident report · Cessna T210M · January 30, 2016

Date
January 30, 2016 · 06:10 local
Airport
Chandler Municipal
Phase of flight
Takeoff: Climb Out
Operating rules
General operating rules (Part 91)
Damage
No damage
Aircraft
N732SJ
Reported as
Cessna T210M
Reported engine
Continental TSIO-520 series
People aboard
1
Fatal injuries
0
Other injuries
0
Pilot’s certificate
Private pilot
Pilot’s flight hours
940 total14 in this make and model20 in the last 90 days

From the FAA’s Accident/Incident Data System (AIDS), through its Aviation Safety Information Portal, as reported. The NTSB investigates accidents separately, and its record of an accident is the fuller one. The aircraft is matched to the registry by N-number and event date, checked against the reported make and model; the registry’s history has gaps, so older matches can be wrong. Compare the reported make and model.

What happened

The FAA’s narrative, in sentence case. The FAA writes it in capitals and removes private details.

1/30/2016 - Discussion with pilot indicated that he had taken off from chd for a local flight. Upon gear retraction the gear did not cycle into the retracted position. He made a flight by the tower for them to observe gear position. They visually confirmed the gear was not fully retracted. The pilot flew around for a while attempting to get the gear to transition using the normal gear electrical system. Finally he used the emergency handle to release the gear and was able to pump the gear to the down and locked position.

Pilot landed without further incident at chd.

Maintenance inspected landing gear system and determine the MLG pressure switch was inoperative (open all the time). Pressure switch was removed, cleaned, inspected, and tested and re-installed. Gear retraction test was successfully conducted multiple times with no further hang-up conditions. Aircraft returned to service.

As the FAA filed it

1/30/2016 - DISCUSSION WITH PILOT INDICATED THAT HE HAD TAKEN OFF FROM CHD FOR A LOCAL FLIGHT. UPON GEAR RETRACTION THE GEAR DID NOT CYCLE INTO THE RETRACTED POSITION. HE MADE A FLIGHT BY THE TOWER FOR THEM TO OBSERVE GEAR POSITION. THEY VISUALLY CONFIRMED THE GEAR WAS NOT FULLY RETRACTED. THE PILOT FLEW AROUND FOR A WHILE ATTEMPTING TO GET THE GEAR TO TRANSITION USING THE NORMAL GEAR ELECTRICAL SYSTEM. FINALLY HE USED THE EMERGENCY HANDLE TO RELEASE THE GEAR AND WAS ABLE TO PUMP THE GEAR TO THE DOWN AND LOCKED POSITION.

PILOT LANDED WITHOUT FURTHER INCIDENT AT CHD.

MAINTENANCE INSPECTED LANDING GEAR SYSTEM AND DETERMINE THE MLG PRESSURE SWITCH WAS INOPERATIVE (OPEN ALL THE TIME). PRESSURE SWITCH WAS REMOVED, CLEANED, INSPECTED, AND TESTED AND RE-INSTALLED. GEAR RETRACTION TEST WAS SUCCESSFULLY CONDUCTED MULTIPLE TIMES WITH NO FURTHER HANG-UP CONDITIONS. AIRCRAFT RETURNED TO SERVICE.

Other reports on N732SJ · 1

Matched to the same aircraft by N-number and date.