duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2140' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2140' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026101320320Controller · faultyUNCONTROLLABLE FLT DECK TEMP. ONLY HOT. ONLY COOLED W/LT PACK OF F. DEBRIEF FROM CA, FLIGHT DECK TEMPERATURE HOT WITH LT & RT PACKS ON, LT AIR MIX VALVE GAUGE READING RIGHT ABOVE HALF ON HOT SIDE, PERFORMED AUTO & MANUAL CONTROL INPUTS WITH NO CHANGE IN TEMP, SDR DALA2026101205601Heater · odorAFTER ENGINE START, AFT FA'S REPORTED STRONG DIRTY SOCK/MUSTY SMELL IN AFT GALLEY AND LAST 2 ROWS. SMELL REMAINED WITH PACKS ON R ENG BLEED, L BLEED ALREADY DEFERRED. C/W SMOKE AND FUME W/C 0550-2001 WITH NO ISSUES FOUND. DUE TO REPORT OF FUME ONLY IN AFT GALLSDR DALA2026092905407Heater · burnedDIV - INTO OPO (PORTO) DUE TO BURNING RUBBER SMELL AROUND 4L DOOR. FLOOR PANEL HEATER SHOWED BURNED MARKS ON FLOOR MAT AT DOOR 4L. DEFERRED FLOOR PANEL HEATER FIN 9DS. (9523498) AIRCRAFT WAS GROUNDED.SDR 8LFA202609260005Heater · dirtyAIRCRAFT HEATER EMITTED A WHITE HAZE INTO THE CABIN WHEN TURNED ON. FURTHER INVESTIGATION DISCOVERED THAT THE HEATER HAD NOT BEEN USED DURING RECENT SUMMER MONTHS. THIS HAD BEEN THE FIRST ACTIVATION OF THE AIRCRAFT HEATER OF THE FALL SEASON. HEATING SYSTEM SDR CALA2026082118773Heater · odorAFTER TAKEOFF FA REPORTED AN ODOR IF AFT GALLEY. TURNED OFF GALLEY HEATERS AND ODOR WENT AWAY. ABOUT 15 MIN AFTER TAKEOFF, HEATERS WERE TURNED BACK ON WITH NO ODOR THE REST OF THE FLIGHT. NO INBD FDE CAPTURED. NO ODOUR DETECTED ON GRD ON ARRIVAL. AIR DISTRISDR CALA2026080718361Controller · faultedCAPTAINS SHOULDER HEATER PRODUCES A FOUL SMELL WHEN TURNED ON. CAPT REPORTS L/H SHOULDER HEATER HAS A BURNT SMELL, WHICH FOLLOWS SWITCH ON AND GOES AWAY IN OFF POSITION. L/H HEATER, COMPLIED WITH DDG 21-45-02, C/B PULLED, HEATER CONNECTOR REMOVED, CAPPED, ANDSDR CALA2026070717597Heater · contaminatedBURNING ODOR EXISTS IN GALLEY AFT OF BUISNESS CLASS. INSPECTED AREA ABOVE MID GALLEY FOUND DEBRIS ON GALLEY DUCT HEATER AND GALLEY VENT CLOGGED. CLEANED, REMOVED AND REPLACED GALLEY VENT FILTER IAW AMM 21-26-08-00B-720A-A. OPENED CABIN DOORS TO AIR OUT RESDR QR9R2026061100002Ejector · inoperativeHEATER NOT WORKING IN THE NORMAL OR EMERGENCY POSITIONS DURING START RUNUP. HEATER MIXER/SHUTOFF UNIT FAILED USING THE LUH-72 HEATER EJECTOR TEST SET AND TROUBLESHOOTING GUIDE IAW AMM 21-41-00, 1-1. REMOVED AND REPLACED HEATER EJECTOR ASSY.SDR QR9R2026060900001Ejector · inoperativeDURING START RUN-UP, HEAT MESSAGE DID NOT APPEAR ON DISPLAY DURING BLEED HEAT CHECK. OUTSIDE AIR TEMP WAS 1 DEGREE C. REMOVED AND REPLACED HEATER EJECTOR ASSEMBLY IAW AMM 21-41-00, 4-1. MOC SUCCESSFULLY COMPLETED.SDR DALA2026060903496Heater · odorFUME EVENT DURING BLOCK IN RIGHT AFTER APU START. SEVERITY OVERWHELMING BURST OF ELECTRICAL BURNING ODOR. AFT GALLEY NO PHYSICAL EFFECT BY CREW OR PASSENGERS. NATURE ELECTRICAL. TIME 1753 LEVEL A DISSIPATES ON ITS OWN. T/S ODOR PER AMDS WC 0550-2001. USED P-TRSDR QMLA2026060120034Heater · failedDURING CRUISE FLIGHT, CABIN FUMES WERE DETECTED, FOLLOWED BY VISIBLE SMOKE. THE FLIGHT CREW EXECUTED THE EMERGENCY PROCEDURES AND CHECKLISTS, WHICH INCLUDED SHUTTING DOWN ALL NON-ESSENTIAL SYSTEMS. TURNING OFF THE FOOT HEATER IMMEDIATELY AFTER DETECTING THE FUSDR CALA2026060116707Duct · faultyBURNING / SMOKE ODOR COMING FROM MID GALLEY HEATER WHEN TURNED ON TALKED TO CREW AND FILLED OUT SMOKE/ODOR REPORT. THEY REPORTED ALL NORMAL CRUISING CONDITIONS AND THAT THE ODOR EXTINGUISHED AS SOON AS THEY TURNED THE HEATER OFF AND DID NOT TURN IT BACK ON FOSDR REXA2026060400900Heater · inoperativeFWD FLIGHT ATTENDANT CALLED REPORTING A STRONG SMELL (A STRONG FUME ODOR) DURING CLIMB OUT. NO EICAS INDICATIONS NO SMOKE OBSERVED IN THE FLIGHT DECK. THE SMELL SEEMED TO BE STRONGEST IN THE GALLEY AREA. R & R GALLEY EXHAUST FAN IAW AMM 21-23-93. OPC NOSDR CALA2026051116160Heater · odorSTRONG ODOR FROM GALLEY HTR IN FLT. ALL HEATERS TURNED OFF RESET FWD,MID 1 & MID 2 GALLEY HEATER TEST C/OUT AS PER AMM 21-40-F5-29A -421A.GRD TEST AIR DIST SYSTEM,SYSTEM TEST PASSED.NO ACTIVE OR STATUS MSG.REFER LOG PAGE 8822516,8822438 & 8822414 FOR DEFER FWDSDR CALA2026050415947Heater · failedDEBRIEF FROM TEST FLIGHT CREW WAS THAT TEST FLIGHT WAS UNSAT. ODOR IN CABIN REMAINS ON CLIMB. REPORTED ODOR SMELLED LIKE A MUSTY FURNACE TURNING ON FOR THE FIRST TIME. REPLACED MID GALLEY HEATER. REF AMM 21-45-30-01A-720A. PERFORMED AIR DISTRIBUTION GROUND TESSDR QR9R2026042200002Ejector · inoperativeDURING START RUN-UP, HEATER WAS INOPERATIVE. TROUBLESHOOTING DETECTED HEATER EJECTOR WAS BAD. REMOVED AND REPLACED HEATER EJECTOR IAW AMM 21-41-00, 4-2.SDR DALA2026041002301Heater · odorDIVERTED TO OAK DUE TO DIRTY SOCK SMELL. DECLARING AN EMERGENCY. DEFERRED AFT GALLEY FAN AND GALLEY HEATER. LATER, AFT GALLEY HEATER WAS REPLACED. (LP 7963269, 7963271 - AIRCRAFT WAS GROUNDED)SDR AALA202604071761Heater · failedAIRCRAFT WAS GROUNDED: DURING FLIGHT THE FLIGHT ATTENDANT 3 AND 4 REPORTED BURNING ODOR NEAR 4L DOOR WHICH CAUSED NOSE AND THROAT IRRITATION. CLOSING THE VENT ABOVE DOOR 4L HELPED REDUCE THE SMELL. NO SMOKE OR FUMES WERE REPORTED WITH THE ODOR. ACCOMPLISHED WOSDR CALA2026040315061Heater · odorFLIGHT ATTENDANTS AT DOORS 1L AND 1R REPORT BURNING ODOR FROM FWD GALLEY AREA JUST AFTER LIFTOFF. ODOR DISSIPATED WITHIN A COUPLE OF MINS. ALL GALLEY OVENS & COFFEEMAKERS WERE OFF WHEN ODOR WAS NOTICED. LOCKING CREW REPORTED PLASTIC BURNING ODOR FOR 2 MINS ASDR DALA2026031601802Heater · odorACRID SMELL NOTED IN CREW REST AREA, ABOUT 5HRS INTO FLIGHT. PULLED THE BREAKERS IN THE AFT GALLEY AND CONTINUED, THEN REPLACED FAULTY CREW REST HEATER. OK FOR SERVICE. (8340050)SDR DALA2026031701851Heater · odor(LOG 8253572) BURNED PLASTIC ODOR IN THE BACK GALLEY AREA DURING THE BEGINNING OF THE DECSENT. IT DISIPATED ON ITS OWN. R/R AFT GALLEY DOOR AREA HEATER PER B737 AMM 21-45. OPS CHK NML.SDR DALA2026030201406Heater · odorDUE TO DECLARED EMERGENCY FOR BURNING PLASTIC SMELL. R/R AFT GALLEY HEATER AND Y REDUCER DUCT. (L/P# 8036184, 8036185)SDR QR9R2026022600001Ejector · inoperativeHEATER EJECTOR ASSEMBLY WAS RECEIVED FROM SUPPLY WITH ZERO HOURS TIME SINCE REPAIR. AN OPERATIONAL CHECK REVEALED THE CLOSED LIGHT WILL NOT ILLUMINATE ON HEATER EJECTOR ASSEMBLY.SDR BAGA2026022400006Heater · odorWHEN HEATER TURNED ON THERE WAS A BURNING SMELL. REMOVED AND INSTALL GALLEY HEATER. OPS CHECK GOOD. THIS CLEARS MEL. NO MEDICAL ATTENTION WAS NEEDED FOR CREW OR PAX AND NO EMERGENCY DECLARED.SDR BAGA2026021900003Heater · fodAFT GALLEY HEATER ODOR WHEN TURNED ON THAT DID NOT DISSIPATE. SMELLED LIKE A WOMANS HAIR DRYER. FOUND LINT ON GALLEY SCREEN, LINT REMOVED. PLACED ON MEL. REMOVED AND REINSTALLED THE AFT GALLEY HEATER TO FURTHER IINSPECT THE COMPONENT, FOUND DUST AND OTHER FOD.SDR QR9R2026020900001Ejector · failedAFTER RECEIPT OF PART FROM SUPPLY, AVIONICS PERSONEL FOUND THE HEATER EJECTOR ASSY FAILED TESTING (PRIMARY VALVE STUCK OPEN).SDR DALA2025122209279Control Unit · failedAIRCRAFT 3055, LEAVING ATL CRUISING AT FL300, FLIGHT ATTENDANTS REPORTED VERY STRONG "BURNING RUBBER" SMELL FROM DOOR 3 AFT TO AFT GALLEY. AFTER APPROX. 10 MINS AT FL300, ODOR DISSIPATED. UPON DESCENT DURING ARRIVAL AT FL300, SAME ODOR RETURNED. DEFFERRED 3LSDR BAGA2025120300001Heater · odorAFT GALLEY HEATER WHEN TURNED ON GAVE STRONG ELECTRICAL BURNING SMELL. WHEN TURNED OFF, SMELL DISAPATED AND DID NOT RETURN. HEATER LEFT OFF FOR DURATION OF FLIGHT. NO ONBOARD MEDICAL ATTENTION NEEDED FOR CREW OR PAX. NO EMERGENCY DECLARED. AFT GALLEY HEATER PLSDR VNAA2025112811101Heater · odorGALLEY HEATER OVERHEATED AFTER TAKEOFF CAUSING BURNING SMELL. BREAKER CPB-2 B11 POPPED / REMOVED AND REPLACED GALLEY HEATER IAW CRJ900 AMM 21-23-64-000/400-801-A04. OPS TEST GOOD AT THIS TIME.SDR FDEA202511232199Modulating Valve · failedDURING DESCENT, FLIGHT DECK TEMP EXCESSIVELY COLD. RAN ECL CABIN TEMP COLD CHECKLIST WITHOUT IMPROVEMENT. DESCENDED FOR MANUAL VENTILATION. FLIGHT DECK TEMP REACH 15C AND TRIM AIR/COCKPIT AIR STILL FULL COLD. AMM: 21-61-02-4 FIM: 21-22-00-2/803 NOTE THSDR CALA2025112411409Heater · contaminatedCREW VERBAL REPORT PASSENGERS IN ENTIRE CABIN EXPERIENCED EYE IRRITATION AND NAUSEA DURING FLIGHT. NO SMOKE OR ODOR EVENT. A/C PACKS OPERATED NORMALLY. CONTACTED SFO HMC TO DEBRIEF CREW FOR ANY ADDITIONAL INFORMATION. DEBRIEFED CREW THE EVENT HAPPENED ON THE LSDR DALA2025112008486Heater · odorF/A REPORTED BURNING SMELL IN AFT GALLEY. REMOVED AFT DOOR AREA HEATER REF AMM 21-45. SMELL WENT AWAY FOUND DISCOLORATION IN THE HEATING ELEMENTS. INSTALLED AFT DOOR HEATER PER B737 AMM 221-45. OPS GOOD.SDR DALA2025111808423Heater · odorDURING CRUISE FLIGHT AN ODOR WAS OBSERVED COMING FROM AREA OF CAPT GASPER VENT AND SPEAKER AREA. SMELLED LIKE AN ELEC HEATER WHEN TURNED ON. REMOVED AND REPLACED CAPT SHOULDER AND FOOT HEATER PER B767 MM 21-45. OPS CHECKS GOOD. NO ODOR DETECT ON A/C ARRIVAL SDR HYIA20251107004Pump · leakingPILOT REPORTED A FUEL SMELL IN THE CABIN. MAINTENANCE INSPECTED AND FOUND THE HEATER FUEL PUMP LEAKING. THE FUEL PUMP WAS REPLACED WITH NO FURTHER DEFECTS NOTED.SDR YENA2025102801061Heater · odorFLT#318, JFK-BOS. "FWD GALLEY HEATER ( GALLEY HEATER (GHTR) FWD GALLEY )FA1 REPORTED STRONG CIGARETTE SMOKE SMELL ON SHORT FINAL NEAR ROW 1 NOT OBSERVED IN FLIGHT DECK" (SUPPLEMENTAL INFORMATION TO FOLLOW)SDR HYIA20251010002Heater · leakingPILOT REPORTED A FUEL SMELL IN THE COCKPIT WITH THE HEATER RUNNING. MAINTENANCE INSPECTED AND FOUND COMBUSTION HEATER FUEL SOLENOID LEAKING. REMOVED AND REPLACED COMBUSTION HEATER WITH NO FURTHER DEFECTS NOTED.SDR CALA2025092609288Heater · odorFORWARD GALLEY HEATERS EMIT FOUL ODOR WHEN TURNED ON. PERFORMED A TEST OF THE FWD GALLEY DUCT HEATER IAW MM DMC-B787-A-21-45-30-00A-720A-A. TEST PASSED. DID NOT SMELL ANY FOUL ODOR.SDR AALA202509168023Heater · shortedAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: RIGHT AFTER LIFT OFF, STRONG FUME SMELL WAS PRESENT IN CABIN. IT SMELLED LIKE SOMETHING WAS BURNING BUT NO SMOKE WAS PRESENT. WE COULD NOT DETERMINE THE SOURCE OF THE FUMES. AIRCRAFT AIR INTERRUPTED BACKSDR 454A250906075836Heater · dirtyCREW OBSERVED SMOKE IN CABIN WITH HEATER ON CLIMB-OUT. THE PIC DECIDED TO ABORT THE FLIGHT AND RETURN TO STARTING POINT. UPON INVESTIGATION, IT WAS DISCOVERED THAT THIS WAS THE FIRST TIME THAT HEATER HAS BEEN TURNED ON SINCE THE SPRING MONTHS. LINT AND DUST WISDR CALA2025082208051Heater · burnedSMOKE IN PILOT REST AREA COMING FROM VENT, ALSO IN FOWARD GALLEY PER CREW DEBRIEF, F/A STATED SMOKE COMING FROM PILOT BUNK AREW VENTS, DID NOT SMELL ELECTRICAL PER F/A & PILOT THAT INSPECTED AREA. UPON ARRIVAL TO ACFT NO SMELL, ODOR, OR SMOKE SEEN WHEN DOORSDR DALA2025081506108Heater · fod(LOG 7779814) FA REPORTED FUEL AND ELECTRICAL SMELL IN THE MID TO AFT CABING AND AFT GALLEY. BOTH PACKS WERE IN AUTO AND CLIMB POWER WAS SET. DISSIPATED IN LESS THAN 5 MINUTES PER FA. INSPECTED AFT GALLEY HEATER AND FOUND IT CONTAMINATED WITH DEBRIS AND FAN NOSDR IPXA2025071167979Valve · faultedAT FL380 UNABLE TO CONTROL UPPER DECK TEMP€™S. THIS WAS APPROX 1.5 HRS INTO FLIGHT AFTER TALKING WITH MX, DISPATCH AND 5ME, DIVERT BACK TO ANC WAS DECIDED. REMOVED AND REPLACED IASC #1. UPDATED AND VERIFIED SOFTWARE AS PER DASH 8 MATRIX REF AMM 36-10-01-470-8SDR DALA2025070705065Controller · faultedSHIP 3119 - ATO - DUE TO AFT CARGO HEAT MESSAGE AT THROTTLE UP. DEFERRED AFT CARGO HEAT PER MEL AND CONTINUE. REPLACED AFT CARGO HEAT CONTROLLER 10HV.SDR DALA2025061704573Heater · odorMUSTY SMELL REPORTED IN THE AFT GALLEY BY FA'S AFTER TURNING GALLEY HEATER ON. ODOR DISSIPATED ABOUT 15-20 MINUTES AFTER TURNING HEATER BACK OFF. C/W NO GO ODI. ODOR IS ISOLATED TO AFT GALLEY HEATER. R/R AFT GALLEY HEATER IAW A220 AMP 12-42. OPS CHECKS GOOD. SDR CALA2025051904757Heater · faultedFLT ATNDTS DETCTD SMOKE ODOR NEAR DOOR 2R. 2R DOOR HEATER WAS TU RNED OFF. TOMC ADVISED CREW REPORTEDLY TURNED OF DOOR 2R HEATER AND ODOR DISSIPATED. (MC) PERFORMED SMOKE/ODOR IN CABIN CONDITIONAL INSPECTION IAW AMM 05-51-56-202-001-001 NO OTHER FAULTS NOTED. SDR DALA2025051403737Heater · odorSHIP 6814 AT FL380 SMELLED A SLIGHT BURNING SMELL COMMING ONLY FROM THE CAPTAIN SIDE LOWER VENT WHEN OPENED. FOLLOWED PROCEDURES TO REPORT IT AND QRH. CORRECTIVE ACTION: REMOVED CAPT HEATER IAW B757 AMM 21-45. FOUND DEBRIS LODGED IN HEAT. SWAPP SHOULDER HEATERSDR BAGA2025043000008Fan · failedFA TURNED ON AFT GALLEY HEATER, NOTED A SMOKEY BURNING SMELL. NO VISIBLE SMOKE SEEN AND SMELL DISAPPEARED. AFTER TURNING HEATER OFF. AFT HEATER PLACED ON MELL NO EMERGENCY DECLARED, AND NO ONBORARD MEDICAL ATTENTION NEEDED. LOCATION AFT GALLEY. R/R AFT GALLEY SDR BAGA2025043000007Heater · odorFA TURNED ON AFT GALLEY HEATER, NOTED A SMOKEY/BURNING SMELL. NO VISIBLE SMOLE SEEN AND SMELL DISAPPEARED AFTER TURNING HEATER OFF. AFT HEATER PLACED ON MEL. NO EMERGENCY DECLARED, AND NO ONBOARD MEDICAL ATTNETION NEEDED. LOCATION: AFT GALLEY.SDR DALA2025041102817Heater · failed(6521792) UPON ENTERING A/C A BURNING ELECTRICAL SMELL WAS DETECTED IN FORWARD GALLEY & FLIGHT DECK. FWD F/A HEATER HAD AN ELECTRICAL SMELL, FWD HEATER TO MEL 21-00-41A.SDR CALA2025040903661Heater · inoperativeAREA HEATER IN GALLEYDOES NOT HEAT G4L GALLEY FLOOR HEATER EMITS ACRID ELECTRIC ODOR. TURNED OFF-NO ODO R PERFORMED GALLEY AREA HEATING SYSTEM OPERATIONAL TEST PER AMM DMC-B787-A-21-45-00-03A-320A-A.TEST PASSED, OPS OK.
Back to JASC 2140