Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2140' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2140' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014050690953Unknown · malfunctionedCARGO HEAT VLV AFT FAILURE OF AFT CARGO HEAT SOV OR TEMP CONTROL VLV. STATUS MSG-2112031 LATCHD ER MODE. NO MSG WHEN ACFT ARRIVED. RESET CARD & ACCOMPLISHED TEST. PASSED TEST SYS IS OK.SDR HYIA20140424112Pump · leakingPILOT REPORTED FUEL SMELL IN COCKPIT DURING FLIGHT. AFTER LANDING, A WALK AROUND INSPECTION REVEALED THE ODOR WAS COMING FROM THE NOSE AREA WITH VISIBLE LEAKAGE OUT OF HEATER FUEL PUMP DRAIN. MX VERIFIED BY VISUAL INSPECTION THAT FUEL WAS LEAKING FROM THE HEASDR QMLA2014042114040Duct · contaminatedAFTER STARTING THE ENG FOR A SCENE FLIGHT, THE NURSE & MEDIC DETECTED AN UNIDENTIFIED ODOR. ATTEMPTS TO LOCALIZE & IDENTIFY THE ODOR WERE UNSUCCESSFUL & WE ELECTED TO SHUT DOWN WITH NO FURTHER INCIDENT. AFTER ADDITIONAL GND RUN, THE ODOR WAS DETERMINED TO BESDR HYIA20140421108Heater · leakingDURING A TRAINING FLIGHT THE PILOT REPORTED A FUEL SMELL IN THE COCKPIT WHEN THE HEATER WAS ON. HE SHUT OFF THE HEATER & REPORTED THE DISCREPANCY TO MX. SECURED THE B NUT AT THE HEATER FUEL NOZZLE. OPERATIONAL & LEAK CHECKS WERE PERFORMED WITH NO DISCREPANCSDR 2014FA0000251Combustion Tube · failedHEATER HAD ZERO TIME IN FEBRUARY 2004. OVERHAULED TO ZERO TIME IN JULY 2010 WITH NEW COMBUSTION TUBE ASSY. COMBUSTION TUBE INNER LINER HAS SAGGED, COLLAPSED AND PARTIALLY MELTED.SDR CA141219002Combust Chamber · cracked(CAN) THIS WAS DISCOVER DURING REGULAR 5 YEARS PRESSURE DECAY TEST OF THE HEATER, THE UNIT FAIL TEST. IT WAS REMOVED TO PERFORM ANOTHER TEST. THE LEAK SEEM FROM A CRACK IN THE COMBUSTION CHAMBER INTERCONNECTION BETWEEN INNER & OUTER SECTION. THE FAIL UNIT WASSDR AALA20140317008Heater · failedSTL CREW REPORTED SMOKE & FUMES IN THE FWD CABIN. EMERGENCY DECLARED FLIGHT RETURNED STL LANDED WITHOUT INCIDENT. INSPECTED ACFT & FOUND FWD CARGO COMPARTMENT HEATER FAILED. DEFERRED FWD CARGO COMPARTMENT HEATER SYS EAW MEL 21-38. FLIGHT CONTINUED TO DESTISDR STRA2014FA0000162Heater · contaminatedSHORTLY AFTER TAKEOFF, PILOT TURNED ON CABIN HEATER AND ALMOST IMMEDIATELY, A FOUL ODOR WAS DETECTED BY ALL CREW MEMBERS, SMELLED LIKE SOMETHING BURNING. A HAZE OF WHAT APPEARED TO BE SMOKE WAS EXPERIENCED IN CABIN AREA. AN IMMEDIATE RETURN TO DEPARTURE INISDR 2014FA0000295Heater · fireNOSE COMPARTMENT WAS DISCOLORED, PAINT BLISTERED, EVIDENCE OF A FIRE IN THE COMPARTMENT.SDR USAA2014021100008Heater · shortedPHX FLT 675 EN-ROUTE HNL TO PHX. CAPTAIN'S FOOT HEATER SHORTED WHEN ACTIVATED. SPARKS FROM ON FLOOR TO LT OF YOKE. R & R CAPTAIN`S LT FOOT WARMER ASSEMBLY. OPERATIONS CHECKED GOOD.SDR PAI5201401161393Mixing Valve · failedPILOT COMPLAINED OF NO CABIN HEAT. INSPECTION FOUND HEATER MIXING VALVE ON FIREWALL WITH BROKEN FLANGE, ALLOWING FLEX DUCT FROM HEAT MUFF TO COMPLETELY DISCONNECT FROM THE MIXING VALVE. FLANGE SHOWED VERY LITTLE WELD PENETRATION.SDR DALA14003443734Heater Blanket · shortedDURING FLIGHT, SMOKE AND ODOR WAS NOTED ALONG WITH WARM SIDEWALL PANEL AT SEAT 18A. ACFT DIVERTED. MAINTENANCE FOUND AFT OVERWING EXIT DOOR HEATER BLANKET SHORTED. BLANKET WAS REPLACED, OPS TEST OK, AIRCRAFT RETURNED TO SERVICE.SDR CALA2014010294080Unknown · malfunctionedLOWER LOBE CREW REST IS HOT WILL NOT COOL OFF. DEFERRED FOR TIME LOWER LOBE CREW REST DEACTIVATED CLOSED, MEL APPLIED & MX ACTION CARRIED OUT. MAT TEST OF SHUTOFF VLV OK, ACCOMPLISHED FIM IAW 21-41-801 & OPERATIONS CHECKED OKAY.SDR HYIA20140102001Heater · faultyCABIN HEATER PRODUCES HEAVY EXHAUST SMELL & MINIMAL HEAT WHEN ON. DEFERRED CABIN HEATER FAN IAW MEL 21-01-2.SDR 39LA2013122643Blower Motor · seizedHEATER BLOWER MOTOR SEIZED IN FLIGHT EMITTING SMOKE. REMOVED BLOWER MOTOR ASSEMBLY PN ME-600-1000, SN 1013 & INSTALLED OVERHAULED BLOWER MOTOR ASSEMBLY, FAN AXIVAN PN 500702-4491, SN AA-79463 IAW S-61MM SA4045-80, REV 47 CHAPTER 21 AIR CONDITIONING.SDR SWIA201335740Heater · failedWHEN GALLEY SERVICE HEATER IS TURNED ON THERE ARE LOUD CRACKING SOUNDS WITH A BURNING ELECTRICAL SMELL. FLT 2606 REPLACED NR 2 GALLEY HEATER IAW AMM.SDR HYIA201341220001Heater Pump · leakingSTRONG SMELL OF FUEL IN COCKPIT DURING FLIGHT. R & R HEATER FUEL PUMP IAW SERVICE MANUAL, LEAK CHECKED GOOD.SDR CALA2013121893768Heater · inoperativeLOWER LEVEL CREW REST THERMOSTAT HEATER INOPERATIVE, STUCK AT 53F. LOWER LEVEL CREW REST HEATER INOPERATIVE.SDR 39LA2013121329Blower · failedDURING FLIGHT AT CRUISE ALTITUDE WITH CABIN HEAT ON, SMOKE WAS NOTICED COMING FROM THE HEATER AREA. REMOVED HEATER BLOWER PN ME-600-1000, SN 1632. INSTALLED SERVICEABLE HEATER BLOWER PN 500702-4491, SN AA6117 IAW SA4045-80, CH 21-40-0.SDR CALA2013121393674Regulator Valve · faultyAFT CARGO HEAT TEMP ONLY 58F WITH TEMP SEL ON FULL HOT. NO ECAM MSGS OR AMBER IND. REPLACED PRESS REG VLV & TRIM AIR VLV.SDR CALA2013120993571Heater · inoperativeWHILE ACCOMPLISHING SMOKE FUME CHECK MM 05-51-56. FOUND DOOR AREA HEATER FOR DOOR 4 LT & RT NOT WORKING.SDR WX0A071770Fan · malfunctionedFLIGHT ATTENDANT CALLED UP COMPLAINING OF BURNING SMELL BETWEEN ROWS 18 - 21. AFTER 7 MINUTES SMELL WENT AWAY. COMPLIED WITH TASK CARD F0592102 CABIN ODOR, SMOKE & TROUBLE SHOT. LOUD GRINDING NOISE COMING FROM CABIN FLOOR AT ROWS 15 - 18 LT SIDE. PULLED CSDR CALA2013112293190Unknown · malfunctionedAFT CARGO PIT HOT AIR VALVE WILL NOT OPEN, EVEN WHEN TEMP SELECTED FULL HOT.SDR CALA2013111893021Unknown · malfunctionedCARGO HEAT ZONE CONT FAILS TO SEND SIGNAL TO HOT AIR VLV TO OPEN. NO HEAT TO PIT. DEACTIVATED TRIM AIR VLV IAW MEL, POST FLIGHT REPORT FAILURE MESSAGE NO AFT CHC DATA.SDR EPUA20131105001Regulator · leakingRT ENGINE FUEL PRESSURE LOW AT 2000 RPM. MAINTENANCE TECH DISCOVERED THAT THE HEATER FUEL REGULATOR SHUTOFF VALVE (FRSOV) WAS LEAKING AND CAUSING THE RT ENGINE TO BE AFFECTED AS REGARDS TO FUEL PRESSURE. THIS PARTICULAR FRSOV HAD 14.6 OF TIME ON IT SINCE NESDR EPUA20131029001Regulator · leakingDURING INSPECTION IAW AD 2004-25-16 R1, THE FUEL REGULATOR SHUTOFF VALVE WAS FOUND TO BE LEAKING FUEL.SDR CA131025006Block · burned(CAN) PILOT PLUGGED IN THE HEATER AT THE END OF THE DAY AND HEARD A POP NOISE. HE UNPLUGGED THE HEATER AND REPORTED THE DEFECT TO MAINTENANCE. UPON INSPECTION IT WAS FOUND THAT A JUNCTION BLOCK HAD INTERNALLY SHORTED CAUSING THE BLOCK TO BURN AND MELT. IT WASDR CA131028003Motor · inoperative(CAN) HEATER BLOWER MOTOR INOPERATIVE. REPLACED BLOWER MOTOR ASSEMBLY.SDR CALA2013092591452Switch · faultyAFT CARGO HEAT VALVE. DUE TO SEVERAL REPEATS FOR AFT CARGO HEAT TEMPERATURE CONTROL. THIS HAS NOW BECOME A LEVEL 2 CHRONIC. REPLACED AFT CARGO OVER HEAT SWITCH IAW AMM21-44-10 MAT TESTED PASSED.SDR CALA2013092091307Heater · inoperativeCAPTAINS SHOULDER HEATER INOPERATIVE IN LOW & HI. REPLACED CAPTAINS SHOULDER HEATER IAW MM 21-45-12.SDR CALA2013082690719Valve · faultyAFT CARGO HEAT FAULT DISPLAYED ON UPPER ECAM SCREEN. VERIFIED HOT AIR PRSOV CLOSED. REPLACED TRIM AIR VALVE PER AMM & CARGO HEAT CONTROLLER PER AMM. OPERATIONS CHECKED OK, NO FAULT MESSAGE.SDR CALA2013082390704Sensor · dirtyCABIN TEMP CONTROL ISSUES LV2 CLEANED TEMP SENSORS, AND CHECKED FANS FOR AIRFLOW.SDR UALA2013071805042Valve · inoperativeCARGO HEAT, HOT AIR MIX VALVE WILL NOT OPEN. EVEN WHEN SELECTED TO FULL HOT. MAX SUPPLY TEMP 70F.SDR UALA2013061904270Valve · malfunctionedCARGO HEAT VALVE ISSUES. REPLACED AFT CARGO HEAT SHUTOFF VALVE (V21441) IAW AMM AND AFT CARGO OVERHEAT SWITCH (S21293) IAW AMM.SDR UALA2013060703979Valve · failedCARGO HEAT VALVE AFT FAILURE OF AFT CARGO HEAT SHUTOFF VALVE OR (SOV) OR TEMP CONTROL VALVE (TCV). STATUS MSG-2112031 LATCHED ER MODE. CHRONIC FAILURE ON CMC AND HISTORY SUGGESTS VALVE REPLACEMENT. CURRENT MSG HITTING IS 21-12021 CARGO HEAT SHUTOFF VALVE AFTSDR UALA2013060503907Control Valve · failedINTERMITTENT CARGO HEAT VALVE BULK STATUS MESSAGE. CARRIED OUT SYSTEM TEST. TEST FAILS WITH MAINT MESSAGE 21-12032. CHECKED POWER AT DV21444 PER W-D 21-44-21 AND FOUND OK. REPLACED CARGO HEAT SHUTOFF AND TEMPERATURE CONTROL VALVE OPS CHECKED NORMAL IAW MM 2SDR UALA2013060503904Valve · failedSTATUS MESSAGE 2112022 FAILURE OF BULK CARGO HEAT SHUTOFF VALVE OR (SOV) OR TEMP CONTROL VALVE (TCV). REPLACED VALVE WITH NEW IAW 21-44-03.SDR UALA2013052003477Controller · inoperativeCOND AFT CARGO HEAT FAULT AFT CARGO ISOLATION VALVE. REPLACED PER MM 21-43-52.SDR AALA20130514005Heater · malfunctionedAMA - INFLIGHT DFW-ABQ. CREW REPORTED ODOR IN THE FLIGHT DECK. EMERGENCY DECLARED FLIGHT DIVERTED AMA LANDED WITHOUT INCIDENT. FOUND FORWARD CARGO COMPARTMENT HEATER POPPED CIRCUIT BREAKER AND CREATED ODOR. PLACARD FORWARD CARGO COMPARTMENT HEATER AND FLIGHSDR CA130501003Wire · burned(CAN) AIRCRAFT IN CRUISE FLIGHT. PILOT SAW SMOKE AND SHUT DOWN ELECTRICAL POWER TO AIRCRAFT. AIRCRAFT LANDED WITHOUT INCIDENT. INVESTIGATION FOUND RING TERMINAL LAYING ON CABIN HEAT CONTROL. WIRE TRACED BACK AND FOUND CONNECTED TO AMMETER. THIS WIRE MUST BSDR CA130524006Heater · fire(CAN) ON DEPARTURE GOING THROUGH 150 FEET, THE HEATER FIRE BELL AND LIGHT CAME ON. FLIGHT CREW COMPLETED THE DRILL AND THE FIRE WAS EXTINGUISHED. THEY REMAINED IN THE CIRCUIT AND LANDED SUCCESSFULLY.HEATER WAS REPLACED.SDR UALA2013042903004Regulator Valve · inoperativeUNABLE TO ADJUST TEMP IN AFT CARGO BAY. REPLACED TRIM VALVE AND PRESSURE REGULATING VALVE, OPS CHECKED.SDR UALA2013041702620Switch · failedAFT CARGO HEAT HEAT SHUTOFF VALVE STATUS MESSAGES. REPLACED AFT CARGO HEAT SHUTOFF VALVE V21441, NO HELP. DURING MAT TEST OF VALVES VISUALLY CHECKED AND VALVES OPERATING NORMALLY. REPLACED SWITCH REF 21-44-10. CHECKED GOOD REF FIM 21--44 TASKS 801-801.SDR UALA2013041702626Cable · looseCABIN TEMP TOO HOT & UNCONTROLLABLE. FOUND RESTRAINT CABLES LOOSE ON ELBOW AT REHEATER. TIGHTEN AND SECURED HARDWARE ON RESTRAINT CABLE. OPERATED PACKS AND LEAK CHECK ALL INDICATIONS NORMAL, NO LEAK NOTED.SDR UALA2013041502561Shutoff Valve · faultyON TAXI CREW HAD TEMP CARGO HEAT AFT ADVISORY MSG. REMOVED AND REPLACED FAILED UNIT. REF MM21-44-01, PG401. ACP OPS CHK REF MM21-44 -00, PG501. OPS CHK GOOD. OK FOR SERVICE.SDR UALA2013040202165Control Switch · faultyTEMP CONTROL FOR AFT GALLEY FLOOR LOOSE. CONFIRMED THAT THE GALLEY HEATER SWITCH IS BAD. PULLED AND CAPPED C-B. REPLACED CONTROL SWITCH ASSY, TESTED GALLEY HEATING SYSTEM.SDR UALA2013032902052Knob · inoperativeCREW REST LOWER LOBE HEATER MODULE DOES NOT HEAT ENOUGH. TEMP CONTROL KNOB INOPERATIVE VERY HOT AT ALL TIMES. CHECKED GOOD PER FIM.SDR DALA13013525652Duct · contaminatedDECLARED EMERGENCY DUE TO ACRID ODOR AT 2000 FT. CREW DONNED O2 MASKS. NORMAL LANDING. FOUND ACRID ODOR FROM CAPTAIN`S SHOULDER AIR VENTS. FOUND AND REMOVED INSULATION DEBRIS IN AIR HEATER INLET.SDR UALA2013032501849Control Valve · failedCARGO HEAT VALVE AFT FAILURE OF AFT CARGO HEAT SHUTOFF VALVE OR (SOV) OR TEMP CONTROL VALVE (TCV). INTERMITTENT STATUS MSG-2112031 INACTV ER MODE. REPLACED AFT CARGO TEMP. CONTROL VALVE PER AMM.SDR A6WA201303224017Heater · inoperativeSTRONG ELECTRICAL ODOR DURING FLIGHT NO SMOKE OR OTHER ABNORMALITIES NOTED WITHIN COCKPIT-SMELL ISOLATED TO COCKPIT. T/S AND FOUND GALLEY HTR SYS CAUSING BURNING SMELL. REMOVED AND REPLACED NR 1 GALLEY HEATER BLOWER IAW AMM 21-23-05, OPS CHECK GOOD.
Back to JASC 2140