JASC 2150
Service difficulty reports · 12,393
Reports filed under 2150 · Cabin Cooling System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2150' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2150' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2015120214074Actuator · failedLEFT PACK LIGHT ILLUMINATES DURING RECALL. ACFT GROUNDED. R & R NR 1 RAM AIR EXHAUST ACTUATOR IAW AMM 21-51-21. PERFORMED TASKS AMM 32-09-00 FOR AIR MODE AND GROUND MODE FOR INSTALLATION. PERFORMED PACK TEMP CONTROLLER BITE TEST AMM TASK 21-61-00. OPS TESSDR ASAA2015120214076Warning Light · false activationLEFT PACK TRIP LT ON APPROACH. ACFT GROUNDED. BITE TESTED ZONE TEMP CONTROLLERS, RT ZTC BITE GOOD. LT SHOWED, RAM AIR ACTUATOR, LEFT ON THIS FLT. NO FAULTS ON PREV FLT OR VERIFY. OPS CHECK GOOD.SDR ASAA2015120214075Warning Light · false activationLEFT PACK LIGHT ON WHEN RECALL IS PUSHED. RESETS WITH MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED BITE ON NR 1 PACK/ZONE TEMP CONTROLLER, FAULTED RAM AIR ACTUATOR WAS ABLE TO RESET FAULT WITH NO OTHER FAULTS. OPS NORMAL.SDR ASAA2015120114066Controller · failedLEFT PACK LIGHT ILLUMINATES DURING RECALL AND GOES OUT WITH WITH MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED BITE CHECK REF FIM 21-62, TASK 801. NR 1 RAM AIR INOPERATIVE. RESET TEMP CONTROLLER, BITE CHECK NORMAL.SDR ASAA2015112914021Actuator · failedLEFT RAM DOOR FULL OPEN LIGHT REMAINED ILLUMINATED ENTIRE FLIGHT. ACFT GROUNDED. CONFIRMED FAULT, LT PACK/ZONE TEMP CONTROLLER SHOWS RAM AIR ACTUATOR FAULT. R & R, FWD, LT RAM AIR INLET ACTUATOR REF AMM TASK 21-51-21 & INSTALLED, AFT, LT RAM AIR EXHAUST ACTSDR SIMA20151129001A/C Pack · malfunctionedON TAKEOFF CREW RECEIVED PACK 1 CLOSED MSG. NR 1 PACK CLOSE WILL NOT OPEN. CREW COMPLIED WITH AOM VOL 1 PROCEDURES & RETURNED WITHOUT INCIDENT. FLIGHT CREW PLACARD NR 1 PACK MEL 2129.SDR ASAA2015112613952Controller · malfunctionedRIGHT RAM DOOR FULL OPEN LIGHT ILLUMINATED IN CRUISE. ACFT GROUNDED. ACCOMPLISHED BITE ON BOTH ZONE TEMP CONTROLLERS, NO FAULT FOUND REF AMM 21-61-00. UNABLE TO DUPLICATE IAW FIM 21-51-00-810-803.SDR ASAA2015112513953Warning Light · false activationLEFT RAM DOOR FULL OPEN LIGHT AFTER TAKEOFF, REMAINED ILLUMINATED FOR ENTIRE DURATION OF FLIGHT. ACFT GROUNDED. COULD NOT DUPLICATE MALFUNCTION. PACK/ZONE TEMP CONTROLLER BITE CK NORMAL. OPS CK NORMAL, ACTUATION WAS SMOOTH AND EVEN DURING BITE CHECK REF FIMSDR RAIA201511240002Acm · lockedCREW REPORTED SMOKE IN THE CABIN. COMPLIED WITH FIM TASK 21-20-00 FOUND FAULTY NR 2 COOLING TURBINE TO BE THE SOURCE OF SMOKE. DEFERRED PACK NR 2. R & R AIR CYCLE MACHINE. OPS CHECK GOOD.SDR ASAA2015112413951Control Valve · failedRIGHT PACK LIGHT ANNUNCIATED ON RECALL. ACFT GROUNDED. R & R RT TCV REF AMM 21-51-10. LEAK CK GOOD. BITE CK GOOD.SDR ASAA2015112013910Controller · faultedDURING MASTER CAUTION RECALL, AIR COND AND RT PACK LIGHTS ILLUMINATED. LIGHTS EXTINGUISHED WHEN MASTER CAUTION WAS RESET. ACFT GROUNDED. TCV FAULT ON NR 2 ZONE TEMP CONTROLLER. CLEARED FAULT AND NR 2 ZONE TEMP CONTROLLER BITE TEST NORMAL IAW MM 21-61-00.SDR ASAA2015111913897Warning Light · false activationON RECALL LT PACK LIGHT ILLUMINATED. RAN QRH, MASTER CAUTION LIGHT GOES OUT. SINGLE CONTROLLER FAULT. ACFT GROUNDED. RESET SYSTEM, RAN AIRCON SYSTEM NR 1 AND NR 2 PACKS, NO ISSUES. ALSO TESTED SYSTEM IAW AMM 21-60-00-700-806, SYS PASSES.SDR SWIA201541606A/C Pack · failedCREW RECEIVED A BLEED 1 OVERPRESSURE CAUTION MESSAGE AFTER TAKEOFF THAT WOULD NOT CLEAR. DECLARED EMERGENCY, RETURNED TO FIELD. C/W FIM PROCEDURES. FOUND THAT PACK 1 WAS PREVIOUSLY DEFERRED IAW THE FIM, ALL FAULTS CLEARED AND OPS NORMAL.SDR CA151119010Acm · failed(CAN) AFTER PUSHBACK THE COCKPIT FILLED WITH SMOKE AND ASH, LEFT PACK AUTO FAIL MSG CAME ON. THE PACK WAS SHUT OFF AND THE SMOKE CLEARED. THE A/C RETURNED TO GATE.SDR ASAA2015111813847Warning Light · false activationAT CRUISE ALTITUDE, BLUE "RAM AIR DOOR FULL OPEN" LIGHT STAYED ILLUMINATED. ACFT GROUNDED. FAULT CODE 215-160-00. PERFORMED BITE TEST OF PACK TEMP CONTROLLER, REF FIM 21-62, TASK 801. NO DEFECTS OR FAULTS LOGGED. PERFORMED FIM 21-51, TASK 803, NO DEFECTS SDR ASAA2015111613799Warning Light · false activationAT CRUISE, SINGLE CHANNEL FAILURE OF RT PACK RECALL. CANCELS WITH MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED FIM TASK 21-62-801, CLEARED FAULTS, FAULT DID NOT RETURN.SDR ASAA2015111613798Warning Light · false activationLEFT PACK LIGHT ILLUMINATES ON RECALL ON TAXI OUT EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. SMART RAM AIR DOOR ACTUATOR DEACTIVATED IAW MEL 21-5D. OPERATIONAL NOTE 1 STATES PACK LIGHT MAY ILLUMINATE DURING RECALL. PRIMARY TEMP OPS NORMAL.SDR R61A201511150839Unknown · odorCREW REPORTED A BURNING ODOR IN THE COCKPIT FROM THE AIR CONDITIONING PACK 1. INSPECTED THE HEAT EXCHANGER AND ACM, RAN PACK OFF APU AND ENGINE AT POWER IAW AMM WITH NO DEFECTS NOTED. ACFT IS GOOD FOR SERVICE.SDR ASAA2015111513781Warning Light · false activationLEFT PACK LIGHT ILLUMINATED ON RECALL IN FLIGHT. EXTINGUISHED ON RESET. ACFT GROUNDED. COULD NOT DUPLICATE. NEITHER PACK LIGHT ILLUMINATED ON RECALL. BOTH ZONE TEMP CONTROLLERS BITE TEST GOOD IAW AMM 21-61-00, NO FAULTS.SDR CA151116006Control Valve · failed(CAN) ON TAKEOFF AND LANDING THERE WAS A BURNING ODOR DETECTED BY THE CREW. NO SIGN OF VISIBLE SMOKE. A PAN PAN WAS DECLARED. LOCAL MTCE IS INVESTIGATING. RT PACK FLOW CONTROL VALVE, RT PACK BYPASS VALVE FILTERS REPLACED AS PER AMM 21-51-01 AND 21-51-00 RESPESDR ASAA2015111113731Door · looseIMMEDIATELY AFTER APPLYING POWER TO ACFT AND ON WALK-AROUND, DISCOVERED RAM AIR DEFLECTOR DOOR, LEFT SIDE, LOOSE. ACFT GROUNDED. ON DEFERRAL.SDR ASAA2015111113733Warning Light · false activationAFTER START, BOTH ACFT PACK LIGHTS REMAINED ILLUMINATED. ACFT GROUNDED. BITE OF NR 2 CONTROLLER SHOWS INLET FAULT INDUCED BY MEL 21-5D. RAN BITE & FAULT CLEARS FROM NR 2 CONTROLLER REF 21-61-00. OPS NORMAL. PACK LIGHT ON LT PACK NORMAL DUE TO MEL.SDR ASAA2015111113732Control Valve · failedON LANDING RECALL, LT PACK ILLUMINATED. ACFT GROUNDED. PERFORMED PACK/ZONE TEMPERATURE CONTROLLER BITE TEST, REF AMM 21-61-00-700-806-002, TCV FAILED AFTER BITE TEST ON NR 1 CONTROLLER. REPLACED LT TCV, REF AMM 21-51-10, OPS CHECK GOOD AND PASSED SUBSEQUENT SDR ASAA2015111113729Actuator · faultedLEFT PACK LIGHT ON RECALL. PACK OPERATES NORMALLY. ACFT GROUNDED. NR 1 PACK/ZONE CONTROLLER LOGGED RAM AIR ACT FAULT. REPLACED NR 1 RAM AIR ACTUATOR, REF AMM 21-51-21.SDR ASAA2015111013707Control Valve · failedCONTROL CABIN SUPPLY AIR TOO HOT, RAN QRH FOR CONTROL TEMP HOT. COULD NOT GET CONTROL OF TEMP. 80 DEGREES INDICATED ON DUCT SUPPLY, LT PACK LIGHT ILLUMINATED, TURNED PACK OFF TO KEEP LIGHT OFF. ACFT GROUNDED. R & R LT TCV LK & OPS NORMAL REF MM 21-51-10. SDR ASAA2015110913708Warning Light · false activationON FINAL, WHEN RECALL CHECKED, RT PACK LIGHT ILLUMINATED. LIGHT EXTINGUISHED WHEN MC RESET PUSHED. ACFT GROUNDED. BITE TEST OF NR 2 TEMP CONTROLLER SHOWS "RAM AIR ACT" FAULT ON "BITE" TEST ONLY. RESET FAULT. FAULT DID NOT RETURN. RAN RT PACK. FAULT DID NSDR ASAA2015110813688Control Valve · faultedLEFT PRIMARY PACK INOPERATIVE. ACFT GROUNDED. ACCOMPLISHED NR 1 & NR 2 TEMP CONTROLLERS BITE TEST IAW TASK 21-61-00-700-806-002. FOUND TCV FAULT ON NR 1 CONTROLLER RESET AND BITE WAS GOOD. RAN PACKS FOR 20 MINUTES, NO FAULTS.SDR ASAA2015110813687Warning Light · false activationLEFT PACK LIGHT ILLUMINATED UPON RECALL. ACFT GROUNDED. ACCOMPLISHED BITE CHECK ON BOTH TEMP CONTROLLERS REF MM 21-61-00, NO FAULTS FOUND. GROUND VERIFICATION CHECKS NORMAL.SDR DXTA2015110506116Switch · unserviceableAT FL 380 IN THE CLIMB, TWO LOUD BANGS, EMER PRESS & ACM OVHT LIGHT CAME ON. CABIN WAS -3700 FPM. STARTED EMER DECENT, AFTER 1 MIN CABIN STARTED PRESSURIZING. THEN THE PROCESS REPEATED ITSELF. PLACED BOTH 410° & 450° ACM OVER TEMP SWITCHES ON ORDER FOR SUPSDR ASAA2015110413642Warning Light · illuminatedUPON RECALL, GOT MASTER CAUTION LIGHT RT PACK ILLUMINATED. CAUTION LIGHT GOES OUT UPON RESETTING MASTER CAUTION. ACFT GROUNDED. PERFORMED PACK TEMP CONT BITE REF FIM 21-62, TASK 801, RT PACK LOGGED TCV FAULT LAST FLT PERFORMED, FIM 21-62, TASK 831 & FAULT CLSDR ASAA2015110413641Acm · damagedLEFT ACM DAMAGED, DISCOVRED DURING PACK FLOW CONTROL VALVE CHANGE. ACFT GROUNDED. R & R LT ACM IAW AMM TASK 21-51-04-400-802-002 THROUGH STEP 31H, 7, I, 39071. COMPLETED STEPS I, J. LT ACM. OPS CK GOOD.SDR ASAA2015110313617Control Valve · failedLEFT PACK LIGHT ILLUMINATES AFTER MASTER CAUTION RECALL. EXTINGUSHES WITH MASTER CAUTION RESET, ACFT GROUNDED. BITE CHECK OF NR 1 PACK/ZONE TEMP CONTROLLER, M 1442, FAULTS TCV THIS PACK. REPLACED LT PACK TCV, V 139. INSTALLATION TEST PASSES. NO LEAKS NOTED,SDR ASAA2015110313613Warning Light · intermittentON RECALL NR 2 PACK LIGHT. RESET GROUNDED. PERFORMED FIM 21-62, TASK 854. APPEARS TO HAVE BEEN AN INTERMITTENT FAULT. BITE VERIFICATION CHECK NORMAL.SDR U2RA201511030001Acm · vibrationON DECENT, A BURNING ODOR WAS PRESENT ON THE UPPER FLIGHTDECK, ODOR FOLLOWED BY HEAVY VIBRATION FROM RT SIDE OF AIRCRAFT. CREW ELECTED TO SHUTDOWN NR 3 PACK. VIBRATION STOPPED. MAINTENANCE FOUND NR 3 ACM AS CAUSE. DEFERRED NR 3 PACK IAW MEL 21-51-01-01.SDR ASAA2015110213600Control Valve · failedLEFT PACK LIGHT ILLUMINATED ON RECALL. EXTINGUISHES WITH MASTER CAUTION. ACFT GROUNDED. PERFORMED BITE TASK 21-62-801. NR 1 TEMP CONTROLLER FAULTED TCV. R & R TCV REF MM 21-51-10. OPS CK/ LEAK CK GOOD. PACK LIGHT DOES NOT ILLUMINATE ON RECALL.SDR ASAA2015110213599A/C Pack · malfunctionedRIGHT PACK ON RECALL. ACFT GROUNDED. ACCOMPLISHED PACK TEMP CONTROLLER BITE ON BOTH CONTROLLERS, FIM 21-62, TASK 801, NR 2 HAD EXIT SRADA FAULT. NR 1, NO FAULTS. ON RECALL, NO PACK LT ILLUMINATED. OBSERVED GREEN LT ON RT AFT SRADA EXIT. OPS CKD NORMAL. RESDR AALA20151031001Control Valve · inoperativeAT 17,000 FEET, RT PACK LIGHT ILLUMINATED. IAW QRH, WARMER TEMP SELECTED & RESET. THE LIGHT CAME BACK ON. THE FLIGHT RETURNED & LANDED WITHOUT FURTHER INCIDENT. NO EMER WAS DECLARED. INSTALLED PLACARD FOR RT PACK MEL. R & R RT PACK TEMP CONTROL VLV IAW ASDR ASAA2015102913557Control Valve · malfunctionedAFTER LANDING, LT PACK LIGHT CAME ON, WENT OUT PRESSING MASTER RECALL. ACFT GROUNDED. BITE CHECKS LT PACK TEMP CONTROLLER IAW FIM 21-62, TASK 801. THIS PACK TCV FAULT DISPLAYED, RESET FAULT. RAN LT PACK, OPS CHECK GOOD ON GROUND. RECALL CK CLEAR.SDR ASAA2015102913556Control Valve · failedEMG ON RECALL, RT PACK LIGHT ILLUMINATES, RESETS. RT PACK ZONE TEMP CONTROLLER LOGGED "TCV" FAULT, WILL NOT RESET. ACFT GROUNDED. R & R RT ACFT TEMPERATURE CONTROL VALVE REF AMM TASK 21-51-10-000-801 , 21-51-10-400-801. LEAK & OPS CK OK.SDR HALA201510290023Control Valve · dirtyAIR PACK 2 REGULATOR FAULT. PACK 2 TEMP CONTROL VALVE, PACK 2 TEMP SENSOR. CLEANED UP NR 2 TEMP CONTROL VALVE IN NR 2 PACK SYS. OPS CHECKED AND BITE ECS PACK 2 SYS OK IAW AMM21-63-00.SDR AALA20151030009Switch · malfunctionedLEFT AIR CONDITIONING PACK LIGHT CAME ON INFLIGHT, NO RESET. THE FLIGHT DIVERTED & LANDED WITHOUT FURTHER INCIDENT. NO EMERGENCY WAS DECLARED. THE LEFT PACK WAS PLACARDED & THE ACFT WAS RELEASED FOR SERVICE. R & R LT PACK COMPRESSOR DISCHARGE OVERHEAT SWITSDR ASAA2015102813546Warning Light · false activationRIGHT PACK LIGHT ILLUMINATED IN FLIGHT, 5000 FT ON FINAL, LIGHT EXTINGUISHED UPON PUSHING MASTER CAUTION. ACFT GROUNDED. RAN PACKS AND BITE TEST BOTH CONTROLLERS REF AMM 21-51-00, ALL OPERATIONS & INDICATIONS NORMAL, NO FAULT FOUND.SDR HALA2015102700217Warning Message · false activationON SHORT FINAL APPROACH APPROXIMATELY 1500' AGL RT PACK TEMP EICAS MESSAGE DISPLAYED. PERFORMED FIM TASK 21-51 FAULT TREE 803 PACK TEMP CONTROLLER BITE, FOUND NO FAULTS, NO 30 DAY HISTORY, OK TO CONTINUE.SDR YENA20151026522Heat Exchanger · failedDIVERTED DUE TO SMOKE IN THE CABIN. SMOKE FUMES DISSAPATED ONCE RECIRCULATION AND BLEED BUTTONS WERE PUSHED OUT. IAW FIM TASK 21-20-00-810-801-A COMPLIED WITH INSPECTION OF THE SYSTEM AS DIRECTED. R & R NR 2 DUAL HEAT EXCHANGER IAW 21-51-04. OPS AND LEAK CSDR YENA20151026519Acm · failedDIVERTED DUE TO SMOKE IN THE CABIN. SMOKE FUMES DISSAPATED ONCE RECIRCULATION AND BLEED BUTTONS WERE PUSHED OUT. PER FIM TASK 21-20-00-810-801-A COMPLIED WITH INSPECTION OF THE SYSTEM AS DIRECTED. FOUND PACK NR 2 FAILED. R & R NR 2 ACM IAW 21-51-005. OPS ANDSDR ASAA2015102513528Warning Light · false activationLEFT PACK ILLUMINATED ON RECALL- EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED BITE ON ZONE TEMP CONTROLER NR 1 FAULTED TCV. CLEARED FAULT, LT "PACK" LIGHT DOES NOT ILLUMINATE ON RECALL REF FIM 21-62, TASK 801.SDR ASAA2015102413504Warning Light · illuminatedRIGHT PACK LIGHT ILLUMINATED DURING MASTER CAUTION RECALL, EXTINGUISHES WHEN RESET. ACFT GROUNDED. RT PACK TEMP CONTROLLER LOGGED TCV FAULT. RAN PACK /ZONE TEMP CONTROLLER BITE TEST AND CLEARED FAULT. RAN RT PACK AND NO FAULT AFTER, NO EXISTING FAULT. OPS SDR UHLA201510220775Acm · failedNR 2 PACK FAILED WITH VISIBLE SMOKE IN CABIN. RAN QRH, SMOKE AND MESSAGE CLEARED. R & R ACM 2 IAW AMM 21-51-05, OPS CHECK GOOD.SDR ASAA2015102213512Actuator · inoperativeLEFT PACK LIGHT ON RECALL-MASTER CAUTION RESET. ACFT GROUNDED. FOUND LT RAM AIR INLET DOOR NOT CYCLING DURING BITE. REF MM 21-01-00. R & R LT SIDE RAM DOOR ACTUATOR REF MM 21-51-21-400-801. C/B ON P6-4 A4 AND A8 OPEN AND TAG FOR MAINTENANCE PERFORMED PACK/SDR VNAA2015102200020Regulator Valve · failedCREW REPORTED RT PACK SHUTOFF WHEN BLEEDS TRANSFERRED FROM APU TO ENGINE. CREW RETURNED TO FIELD AND LANDED WITHOUT INCIDENT. MAINTENANCE TROUBLESHOT, R & R RT AIR CONDITIONING PRESSURE REGULATING AND SHUTOFF VALVE AND PERFORMED CHECKS IAW AMM. ACFT RELEASE
Back to JASC 2150