Reports filed under 2150 · Cabin Cooling System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2150' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2150' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA201437939Actuator · failedAFTER TAKEOFF, SELECTED RT PACK TO AUTO LOW. SMALL AMOUNT OF SMOKE IN COCKPIT. RECEIVED A RT PACK FAIL. RAN QRH, FAILED TO RESET. AT SEVERAL MINUTES LATER THE LT PACK FAILED. RAN QRH PROCEDURE, PACK RESET, FAILED AGAIN A FEW MINUTES LATER. PACKS WERE LT ISDR SWIA2014051637611A/C Pack · failedAFTER TAKEOFF SELECTED RT PACK. SMALL AMOUNTS OF SMOKE IN CABIN FOLLOWED BY RT PACK FAILED.SDR DXTA2014020505637Acm · malfunctionedCOCKPIT FILLED WITH SMOKE RAPIDLY 10 MINUTES AFTER APU STARTED UP FOLLOW BY BURNING SMELL. WE SHUT DOWN THE ACFT RIGHT AWAY. ALSO SMOKE IN THE MAIN CABIN. UNABLE TO DETERMINE WHERE THE SMOKE IS COMING FROM. COMPLIED WITH AIR CYCLE MACHINE REPLACEMENT IAW CSDR ASAA2014050907736Control Valve · malfunctionedRT PACK LIGHT ILLUMINATES ON MC RECALL. ACFT GROUNDED. REPLACED THE RT PACK TEMP CONTROL VALVE ASSY REF MM. 21-51-10. OPS, BITES CK GOOD.SDR SAJFCALS103016Acm · malfunctionedEICAS MSG PACK 2 SHOWS AT HKG, IAW MEL 20-51-01-01, FCSOV SECURED CLSD. CRUISING AT FLT 350, CABIN ALT UP TO 9300', REQUEST DOWN TO FLT 220, CABIN ALT 6300' REDUCING CONTINUE BACK TO NML UNTIL LANDING. AFTER LANDING EICAS MSG PACK 1 & PACK 3 DISPLAY. NR 1 &SDR ABXA2014050980Detector · out of trimEICAS MESSAGE FWD EQUIP OVERHEAT DISPLAYED & OVERHEAT LIGHT ILLUMINATED. LIGHT EXTINGUISHED AFTER SELECTOR WAS POSITIONED TO STAND-BY, ELEC OR BURNING ODOR. COMPLIED WITH FIM, NO FAULTS FOUND. TESTED EQUIP COOLING SWITCH ON P61 PANEL & OBSERVED AN OVERHEAT SDR CA140512011Acm · smoke(CAN) SMOKE IN CABIN DURING ENGINE START, ACM FAILED.SDR USAA2014050500001Panel · out of positionAPPROX 2 HOURS AFTER TAKEOFF, LOUD VIBRATING NOISE REPORTED ROW 13 ACFT RT. NOISE APPEARED COMING FROM OVERHEAD POSITION & FELT OVERHEAD & IN FLOOR BELOW. NOISE IS HIGH PITCHED & CONSTANT, GETTING LOUDER AT 4:50 INTO FLIGHT. FOUND INSPECTION PANEL ON PACK 2SDR ASAA2014050307681Control Valve · failedLEFT "PACK" LIGHT ILLUMINATES DURING MASTER CAUTION RECALL. THE LIGHT EXTINGUISHES WHEN MASTER CAUTION SYSTEM IS RESET. ACFT GROUNDED. LEFT PACK PRIMARY TEMP CONTROL INOPERATIVE. R & R LEFT TEMP CONTROL VALVE REF TASK 21-51-10-000-801 AND 21-51-10-400-801.SDR CALA2014050500563Control Valve · malfunctionedLEFT PACK INOPERATIVE. R & R LT FLOW CONTROL & SOV IAW MM 21-51-01. OPERATIONS CHECKED GOOD. NO LEAKS. OK FOR SERVICE. ROTABLE PARTS CHANGE WAS INDICATED. TT 1581200 SN OFF 01612 VLV, AIR FLO OFF 57-2151-9-0003 1612 ON 57-2151-9-0003 1249.SDR ASAA2014050207682Actuator · failedRT RAM DOOR FULL OPEN LIGHT ILLUMINATED FOR DURATION OF FLIGHT. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONTROLLER BITE, NO FAULTS CURRENT OR RECENT REF 21-61-00. REPLACED RT RAM AIR INLET ACTUATOR IAW MM 21-51-21-000-801 AND 21-51-21-400-801. ACFT GROUND VSDR L4PR201405020089Converter · damaged1 .5 INCHES OF THE CENTER CORE IF THE CATALYTIC OZONE CENTER SEGMENT IS MISSING.SDR WX0A071979Switch · intermittentAFTER TAKEOFF WE NOTICED PRESSURIZATION WAS NOT OPERATING NORMALLY. THE FLIGHT ATTENDANT INFORMED US THAT THE CABIN WAS GETTING HAZY & THE AFT RT SMOKE ALARM HAD ILLUMINATED. TURNED OFF THE PACK & THIS SEEMED TO CORRECT THE PROBLEMS. PERFORMED ENG RUNS, OPESDR SIMA20140430005Grill · damagedAFTER WE LEVELED OFF AT CRUSE AT FL 270 & BEGAN ACCELERATING THROUGH ABOUT 280 KIAS WE HEARD A VIBRATION THAT WAS LOUDER THAN NORMAL, ALSO FOUND A STRONG RAPID VIBRATION IN BOTH CONTROL YOKES. SLOWED ACFT TO ABOUT 240 KIAS WHICH LESSENED THE STRENGTH OF THE VSDR FDEA201404280868Control Valve · inoperativeAFTER TAKE OFF, RECEIVED A NR 3 PACK FLOW DISAGREE. AIR SYS WAS IN AUTO. SOON AFTER, RECEIVED A NR 2 AIR SYS, AIR SYS 1 OFF & AVIONICS FAN OVERRIDE. BLEED 1 & 2 WERE BOTH CLOSED. SWITCHED CONTROLLERS, BACK TO AUTO, PROBLEM REAPPEARED. LEAVING NR 3 BLEESDR QMLA2014042814044Compressor · failedBURNING SMELL & SMOKE IN THE CABIN. AIR CONDITIONING & FAN TURNED OFF & IT SUBSIDED. AIR CONDITIONER COMPRESSOR INTERNAL FAILURE.SDR ASAA2014042707586Warning Light · false activationLEFT PACK LIGHT UPON RECALL DURING LANDING CHECKLIST. ACFT GROUNDED. ACCOMPLISHED BITE OF THE NR 1 TEMP CONTROLLERS IAW FIM 21-61, TASK 801, OPS TEST NORMAL. RESET SUCCESSFUL. NO HISTORY.SDR VNAA2014042600019Acm · failedAFTER ENGINE START, AFTER PUSHBACK, CREW REPORTED RT PACK AUTOFAIL AMBER CAUTION MESSAGE FOLLOWED BY AND ODOR OF SMOKE AND BURNING PLASTIC. RETURNED TO GATE. MAINTENANCE TROUBLESHOT, AND R & R RT ACM AND PERFORMED CHECKS IAW AMM. ACFT RELEASED FOR SERVICE.SDR ASAA2014042607570Warning Light · false activationRIGHT PACK LIGHT ILLUMINATED DURING MASTER RECALL. EXTINGUISHES ON RESET. ACFT GROUNDED. ACCOMPLISHED FIM 21-53 TASK 804. OPERATED RT AIR CONDITIONING PACK REF AMM 21-00-00-800-803. PACK LIGHT REMAINS OFF. PERFORMED PACK / ZONE TEMP CONTROLLER BITE REF FIMSDR QXEA2014042600337Heat Exchanger · failedNOTICED ITT/FUEL FLOW SPLIT DURING DESCENT FROM FL 240 TO 220, NR 1 HIGH ITT/FF. ON LEVEL OFF ADVANCED POWER LEVERS, SMELLED OIL SMOKE ODOR. F/A'S REPORTED HAZE IN CABIN, RETARDED POWER LEVERS, SPLIT VANISHED. CABIN PACK HOT CAUTION ILLUMINATED, RAN CHECKLISDR CALA2014042800509Sensor · failedTIME AFTER FOLLOWING THE QRH PROCEDURES THE RT PACK BEGAN TO CYCLE ON & OFF CONTINUOUSLY, 5 MIN OFF, 1 MIN ON. PERFORMED ASCTU BITE & CTC BITE, FOUND MSG 21-51245 RT PACK OUTLET TEMP SENSOR AT FAULT IAW FIM TASK 21-51-00-810-859. R & R RT PACK OUTLET TEMP SSDR SIMA20140424003Acm · damagedWHILE CRUISING AT FL250, WE ENCOUNTERED INSTANTANEOUS SMOKE IN THE COCKPIT & CABIN. VISUAL INSPECTION FOUND LT ACM DAMAGE. R & R LT ACM IAW AMM 21-51-03. OPERATIONAL CHECK FOUND OK. NO SMOKE IN THE COCKPIT OR CABIN AT THIS TIME.SDR ASAA2014042207559Control Valve · malfunctionedRT PACK LIGHT ILLUMINATED DURING APPROACH, HIT MC, LIGHT OUT. ACFT GROUNDED. REPLACED RT TEMP CONTROL VALVE IAW MM TASKS 21-51-10-000-801, 21-51-10-400-801. PERFORMED PACK/ZONE TEMP CONTROLLER BITE PROCEDURES TEST IAW TASK 21-51-00-700-803. TESTED NORMAL (GRSDR ASAA2014042107551Controller · faultedLEFT PACK TRIP LIGHT ILLUMINATED DURING RECALL. PACK WOULD NOT RESET. ACFT GROUNDED. LEFT PACK TEMP CONTROLLER LOGS "CONTROLLER FAULT". R & R NR 1 ZONE CONT IAW 21-61-20. SYS OPS CKS NORMAL IAW SAME. GROUND CONFIRMATION SUCCESSFUL.SDR ASAA2014042007548Controller · failedAFT CABIN ZONE LIGHT DURING RECALL. ACFT GROUNDED. NR 2 CONTROLLER LOGGED STANDBY PACK CONTROLLER FAULT. R & R NR 2 PACK TEMP CONTROLLER. OP CHECKED NORMAL IAW MM 21-61-20.SDR ASAA2014042007547Warning Message · false activationLEFT PACK LIGHT DURING RECALL. RESETS WITH MASTER CAUTION. ACFT GROUNDED. GROUND VERIFICATION CONFIRMS FAULT. ACCOMPLISHED PACK/ZONE TEMPERATURE CONTROLLER BITE BITE SHOWS LT PACK (TCV). CLEARED FAULT. ACCOMPLISHED BITE AND VERIFIED NO FAULT. RAN LT PACKSDR DALA14025899226Acm · overservicedF/A REPORTED SMOKE & HAZE COMING FROM THE RT OVERHEAD BIN AREA AROUND THE EMERGENCY EXIT ROW. LASTED APPROXIMATELY THREE MINUTES, AT WHICH TIME BEGAN TO DISSIPATE. NO FURTHER ISSUES. TROUBLESHOT, FOUND RT ACM OVERSERVICED. PROPERLY SERVICED RIGHT ACM IAW ASDR ASAA2014041907496Actuator · malfunctionedLEFT PACK LIGHT ILLUMINATED DURING RECALL AND DOES RESET. ACFT GROUNDED. REPLACED LT RAM AIR INLET ACTUATOR AS REQUIRED. PERFORMED OPS CHECK, OPS CHECKED GOOD, RAN BITE CHECK, NO FAULTS FOUND, REF AMM 21-51-21-400-801.SDR CALA2014042190876A/C Pack · faultedMAINTENANCE STATUS MSG PACK DISPLAYED ON THE LOWER ECAM SCREEN. CREW COMMENTS, PACK 2.SDR ASAA2014041807495Warning Light · false activationLEFT PACK LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. BITE TEST OF NR 1 PACK/ZONE TEMP CTRL SHOWED "RAM AIR ACT" FAULT LAST FLIGHT. RESET CTRL AND CLEARED FAULT, IAW MM 21-51-00-700-803. RAN BOTH PACKS FOR 10 MINUTES, NO DISCREPANCIES NOTED. NO HISTORY LASDR ASAA2014041607481Controller · malfunctionedON RECALL LT PACK LIGHT IS ON THE LIGHT GOES OUT WHEN MASTER CAUTION IS PUSHED. ACFT GROUNDED. ONE PREVIOUS FLT FAULT OF "THIS PACK TCV" ON NR 1 ZONE TEMP CONTROLLER. PERFORMED PACK/ZONE TEMP CONTROLLER BITE REF MM 21-61-00-700-806-002 W/ NO DEFECTS NOTED. FSDR ASAA2014041607480Actuator · failedON MASTER RECALL, LT PACK LIGHT ILLUMINATED. LT RAM AIR DOOR FULL OPEN LIGHT ILLUMINATED AS WELL. ACFT GROUNDED. R & R LT RAM AIR INLET ACTUATOR IAW MMS 21-51-21-00-801/21-51-21-400-801. BITE TESTED FOR BOTH PACK/ZONE TEMPERATURE CONTROLLERS IAW TASK 21-51-SDR ASAA2014041507476Control Valve · faultedRIGHT AIR CONDITIONING PACK LIGHT DURING RECALL, EXTINQUISHED WITH RESET. ACFT GROUNDED. ACCOMPLISHED BITE CHECK OF THE PACK TEMP CONTROLLERS, IAW FIM TASK 21-61, TASK 801 - FOUND TCV NR 2 CONT HAD AN INTERMITTENT FAULT. PACK OPS NORMAL. NO HISTORY PAST 60 DSDR ASAA2014041407471Actuator · failedLEFT PACK LIGHT ILLUMINATED DURING LANDING, CHECKLIST RECALL, WOULD NOT RESET. ACFT GROUNDED. REPLACED LT RAM AIR DOOR ACTUATOR IAW MM 21-51-21, OPS CHECKED GOOD. GROUND VERIFICATION GOOD.SDR ASAA2014041207512Actuator · intermittentRIGHT RAM AIR DOOR FULL OPEN LIGHT REMAINED ILLUMINATED DURING FLIGHT. ACFT GROUNDED. FOUND ELECTRICAL CONNECTORS TO ACTUATOR CONNECTED. DISCONNECTED STOWED CONNECTORS TO ACTUATOR IAW MM 21-00-00-040-806 AND RT BLUE RAM AIR DOOR FULL OPEN LIGHT WENT OUT. SDR CA140414003Belt · torn(CAN) AIR CONDITIONER DRIVE BELT FOUND TO BE TORN IN HALF. AIR CONDITIONER COMPRESSOR FOUND TO BE SIEZED.SDR PCSA2014041501Flow Multiplier · seizedSMOKE & FIRE RT WW. EXTINGUISHER DEPLOYED TO PUT OUT FIRE FROM THE FLOW MULTIPLIER INLET. BURNED COMPONENTS REMOVED. REPLACEMENT IN WORK.SDR ASAA2014041107511Modulating Valve · failedLEFT PACK LIGHT ILLUMINATED DURING RECALL, EXTINGUISHED DURING MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONTROLLER BITE TEST ON NR 1 CONTROLLER IAW MM 21-61-00. TCV FAULT WAS LOGGED FOR PREVIOUS FLIGHT, DUE TO HISTORY. REMOVED, REPLASDR UIEA2014041100143Actuator · malfunctionedLT PACK TEMP EICAS MSG. TROUBLE SHOT IAW FIM 21-51T803. RESET FAULT PACK RAM AIR OUTLET ACT, CHECKED GOOD. REPLACED EXHAUST ACTUATOR AS PRECAUTIONARY.SDR ASAA2014040907493Door · malfunctionedLEFT RAM DOOR APPEARS FULLY CLOSED ON GROUND WITH LT PACK ON OR OFF. ACFT GROUNDED. PERFORMED BITE TEST OF NR 1 PACK ZONE TEMP CONTROLLER. TEST PASS OK. GROUND VERIFICATION OF LT RAM DOOR OK.SDR ASAA2014040907492Actuator · failedLEFT RAM DOOR FULL OPEN LIGHT FAILED TO ILLUMINATE WITH FLAP EXTENSION OF AFTER ACFT LANDED. ACFT GROUNDED. R & R LT RAM AIR ACTUATOR IAW AMM 21-51-21. OPS TEST/ BITE CK NORMAL, NO FAULTS FOUND.SDR ASOA20140409043Clamp · loosePILOT REPORTED AFTER TAKEOFF, NR PACK OVERHEAT EICAS MESSAGE, ACCOMPANIED WITH BURNING ODOR. MX INSPECTED AND FOUND A LOOSE CLAMP ON THE NR 2 DUAL TEMP CONTROL VALVE. RAN NR 2 PACK WITH NO FAULTS NOTED. OPS CHECKED GOOD. ACFT WAS APPROVED FOR RETURN TO SERSDR CA140408007Switch · malfunctioned(CAN) DURING A MAINTENANCE INSPECTION OF THE AIR CONDITION OVERHEAT SWICHES ON BOTH ACU FAIL THE TEST, FOUND INOPERATIVE, DURING THE FUNCTIONAL TEST AS REQUIRED BY THE MM PSP 601-2 , CHAP 21-51-3, P201, THIS CHECK IS REQUIRED AT EVERY 4800 HRS MCN 05-0000-048SDR ASAA2014040807475Controller · failedRIGHT PACK LIGHT ILLUMINATED WITH RECALL. LIGHT EXTINGUISHES DURING MASTER CAUTION RESET. ACFT GROUNDED. R & R RT PACK/ZONE TEMP CONTROLLER AMM 21-61-20. OPS CHECKED NORMAL. GROUND VERIFICATION SUCCESSFUL.SDR AALA20140406003A/C Pack · failedBHM INFLIGHT JAX DFW, CREW REPORTED RT PACK FAILED WITH LT PACK ON PLACARD. EMERGENCY DECLARED FLIGHT DIVERTED BHM LANDED WITHOUT INCIDENT. ACFT REMOVED FROM SERVICE. REPLACED RT PACK COALESCE BAG. SYS GND CHECKED NORMAL, OPERATION CLOSED.SDR UIEA2014040600138Actuator · faultyLT PACK OFF LIGHT WILL NOT EXTINGUISH. REPLACED LT PACK RAM AIR EXHAUST ACTUATOR IAW AMM 21-53-02. THIS CLEARS DMI 47403 & MEL 21-51-01-01.SDR ASAA2014040507436Warning Message · false activationLEFT PACK LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. PERFORMED BITE ON NR 1 ZONE TEMP CONTROLLER. TCV FAULT LOGGED, TEST PASSED & TCV CLEARED IAW MM 21-61-00-700.SDR CALA2014040890769Valve · faultyRIGHT PACK MODE EICAS ADVISORY MESSAGE ILLUMINATED AFTER ENG START. REPLACED LOW LIMIT VLV IAW AMM 21-52-30.SDR ASOA20140405071Acm · smokeACFT WAS DESCENDING WHEN THE CREW DETECTED AN ODOR OF ELECTRICAL SMOKE AND THEN BECAME VISUAL IN COCKPIT. AFTER LANDING, MAINTENANCE TROUBLESHOOTING IAW FIM 72-00-00-810-814. MAINTENANCE R & R THE LT PACK ACM IAW AMM 21-51-03. PERFORMED BLEED 1 SYSTEM CLEANSDR 9JLA2014040806901Motor · failedTHE CREW REPORTED THAT THE AFT EVAP CB TRIPPED & WOULD NOT RESET. TROUBLESHOOTING FOUND THE AFT EVAP MOTOR DEFECTIVE. THE UNIT WAS REMOVED PN 1133210-7, SN 0209 & REPLACED WITH NEW UNIT.
Back to JASC 2150