JASC 2150
Service difficulty reports · 12,393
Reports filed under 2150 · Cabin Cooling System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2150' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2150' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DXTA2013032005326Acm · failedWHILE IN TAKEOFF POWER AND ON CLIMBOUT, BLUE SMOKE WAS OBSERVED TO BE VENTING INTO THE FLIGHT DECK. SMOKE WAS EVIDENT UNTIL SUCH TIME AS POWER REDUCTION OCCURRED, THEN THE SMOKE BEGAN TO DISSAPATE. RAN APU WITH NORMAL BLEED AIR AND MAX BLEED AIR. ISOLATION VSDR ASAA2013031994205A/C Pack · malfunctionedLEFT PACK BLEED TRIP AT FL 400, RESET ONCE, BLEED TRIP HAPPENED AGAIN, RESET A SECOND TIME, LIGHT STAYED OUT. PERFORMED BLEED TRIP OFF LIGHT ON, FAULT ISOLATION IAW FIM TASK 36-10 TASK 801. PREFORMED PRELIMINARY CHECKS, FAULT ISOLATION PROCEDURES AND REPAISDR ASAA2013031994199Warning Light · false activationLEFT PACK LIGHT ILLUMINATES DURING RECALL, EXTINGUISHES WHEN MASTER CAUTION PUSHED. PERFORMED BITE TEST OF THE LT PACK/ZONE TEMP CONTROLLER IAW AMM 21-61-00-700-806-002, RAM ACTUATOR FLAGGED ON BIT CHECK. PERFORMED VERIFY AND RECEIVED GREEN GO LIGHT. RESET SDR ASAA2013031994198Warning Light · false activationRT PACK LIGHT ILLUMINATED. IT WILL NOT EXTINGUISH WHEN MASTER CAUTION IS RESET. ACCOMPLISHED FIM TASK 21-61, NR 801, NR 2 PACK ZONE TEMP CONTROL SHOWS TCV FAULT RESET AND CHECKED OK. NR 1 PACK ZONE TEMP CONTROLLER SHOWS STAND BY PACK CONTROLLER FAULT RESET SDR ASAA2013031994197Warning Light · false activationRIGHT PACK LIGHT COMES ON DURING RECALL, EXTINGUISHES WHEN MASTER CAUTION REST. PERFORMED BITE TEST OF RT PACK/ZONE TEMP CONTROLLER REF MM 21-51-00-700-803. NO FAULTS NOTED AFTER SEVERAL TESTS. GROUND VERIFICATION SUCCESSFUL.SDR JJBA20130319007Acm · failedDURING CRUISE, SMOKE APPEARED IN THE FLIGHT DECK AND CABIN. CREW DEPLOYED O2 MASK AND DECLARED AND EMERGENCY. THE LANDING WAS UNEVENTFUL. THE GROUND CREW CHANGED THE ACM.SDR USAA2013032100013Packing · wornAFTER APU START WITH PACKS ON, FLIGHT ATTENDANTS REPORTED DIRTY SOCK ODOR AND WATERY EYES. REPLACED WORN PACKING.SDR UALA2013032101781Valve · faultyLEFT PACK ECONOMY COOLING VALVE IS NOT IN COMMANDED POSITION. REPLACED THE COOLING VALVE AND TESTED OK.SDR SWIA201333043Acm · failedSMOKE IN CABIN, SET OFF SMOKE ALARM IN LAV WHILE ON DESCENT OUT OF FL200. SMOKE IN COCKPIT AS WELL. (FLT 5303) REPLACED RIGHT PACK ACM. P/N: 2204540-4 S/N ON: N/A569SW S/N OFF: 77-298SDR ASAA2013031794209Control Valve · malfunctionedRT PACK LIGHT ILLUMINATES ON RECALL DOES NOT RESET LIGHT GOES OUT WITH MASTER CAUTION RESET. ACFT GROUNDED. UNABLE TO DUP/VERIFY DISCREP. UPON ARRIVAL, RT PACK LIGHT WILL NOT ILLUMINATE ON RECALL. AS REQUESTED, INTERROGATED BOTH TEMP CONTROLLERS - BIT, PREVSDR DXTA2013031805319Acm · failedBURNING ODOR COMING FROM COCKPIT. TURNED COCKPIT PACK OFF AND ODOR DISSIPATED. R & R AFT ACM IAW MM 21-51-00. ACM OPS & LEAK CHECKS GOOD.SDR CA130325010Acm · failed(CAN) CREW REPORTS LT PACK AUTO FAIL CAUTION MESSAGE ON TAKEOFF. MESSAGE CLEARED SHORTLY AFTER ROTATION. SMOKE IN FLIGHT DECK AND CABIN. ACFT RETURNED TO THE FIELD.SDR SWIA201333026Acm · malfunctionedLEFT PACK AUTO FAIL CAUTION MSG ON TAKEOFF. MESSAGE CLEARED SHORTLY AFTER ROTATION. SMOKE IN FLIGHT DECK AND CABIN, RETURNED TO FIELD. (FLT 4644) REPLACED LEFT ACM IAW AMM. P/N GG670-95009-5 S/N ON 00908 S/N OFF 00543SDR ASAA2013031594174Actuator · inoperativeON W/A FOUND LT RAM AIR DEFLECTOR DOOR NOT DEFLECTING. ACFT GROUNDED. RAN BITE CK OF ZONE TEMP CONTROLLER & FAULTED RAM AIR ACTUATOR & ACTUATOR WOULD NOT RETRACT TO PUSH DOOR OUT. R & R LT RAM AIR DOOR ACTUATOR, REF MM 21-51-21 ADJUSTMENT AND TEST GOOD.SDR ASAA2013031494175Control Valve · faultedLT PACK LIGHT ILLUM AFTER START DURING SYS RECALL. ACFT GROUNDED. REPLACED LT PACK TEMP CONTROL VALVE REF MM 21-51-10. OP CHECK GOOD. BITE CHECKED LT PACK TO VERIFY FAULT CLEARED REF MM 21-61-00 BITE CHECK GOOD. RESET PACK CONTROLLER, OK FOR SERVICE.SDR ASAA2013031494173Control Valve · faultedON RECALL, MASTER WARNING, A/C - ANNUNCIATOR AND LT LIGHT CAME ON. ALL EXTINGUISHED UPON RESET. PERFORMED BITE TEST OF LT PACK ZONE TEMP CONTROLLER REF AMM 21-61-00-700-806-002. VERIFIED FAULT, FOUND FAULTED LT PACK TCV. REPLACED LT PACK TEMP CONTROL VALVSDR ASAA2013031394158Warning Light · false activationLEFT PACK LIGHT ON RECALL ON (UNREADABLE) EXTINGUISHES WITH MASTER CAUTION RESET. ACCOMPLISHED PACK/ZONE TEMPERATURE CONTROL BITE TEST, CLEARED FAULTS, OPS NORMAL REF MM 21-61-00-700-806-002. NO HISTORY LAST 60 DAYS.SDR CA130313001A/C Pack · smoke(CAN) AFTER TAKEOFF, THE FLIGHT CREW REPORTED THAT THE CABIN FILLED WITH VISIBLE SMOKE. THE APU WAS THE BLEED SOURCE FOR THE CABIN PRESSURIZATION SYS AT THE TIME OF THE INCIDENT. THE FLIGHT CREW DECLARED AN EMERGENCY AND DEPLOYED THE CABIN OXYGEN MASKS AFTERSDR UALA2013031301486Sensor · faultedPACK 1 FLOW PROBLEMS. REPLACED FLOW SENSOR AND INLET PRESS SENSOR. OPS NORMAL.SDR SIMA20130307003Valve · inoperativeON FLIGHT 4371 THE CREW REPORTED THAT DURING TEST OF RECIRC FAN PER MEL 21-29, THEY HEARD A LOUD GRINDING NOISE AND EXPERIENCED SMELL OF HEAVY SMOKE/ FUMES. THIS OCCURED WITH APU BLEED OPEN, X BLEED OPEN AND BOTH PACKS SELECTED OFF. OPERATED APU, NR 2 PACK ASDR SIMA20130307002Acm · damagedON FLIGHT 4007 THE CREW REPORTED THEY NOTICED AN ELECTRICAL SMOKE SMELL WHEN NR 1 PACK WAS SELECTED. PACK 1 DEFFERED PER MEL 21-29 AUTH # 030322D-C. FOUND AIR CYCLE MACHINE BLADES TO BE DAMAGED. REMOVED AND REPLACED THE IAW AMM 21-51-03. OPS CHECK GOOD. MEL SDR ASAA2013030794107A/C Pack · malfunctionedON CLIMB OUT, RT PACK TRIPPED, RESET PACK IAW QRH. RT PACK TRIPPED A SECOND TIME AND REMAINED OFF FOR THE REMAINDER OF FLIGHT IAW QRH. UNABLE TO DUPLICATE.SDR JJBA201303060001Acm · inoperativeCREW REPORTED A "BURNING DUST" ODOR DURING TAKEOFF THAT DISSIPATED WHEN THE CABIN HEAT WAS TURNED DOWN. AFTER TAKEOFF, CREW OBSERVED A STRONG MELTING PLASTIC ODOR IN THE COCKPIT AND CABIN. THE CREW RETURNED TO FIELD AND DECLARED AN EMERGENCY. ACFT LANDED WSDR UALA2013030501318Valve · faultyFLT DECK TEMPS - LEVEL 2. DUE TO HISTORY OF FLT DECK TEMP TOO COLD. PERFORM COMPLETE BITE OF THE ZONE TEMP CONTROLLER AND BOTH PACK TEMP CONTROLLERS REF FIM MM 21-51-00 FIG 104 AND 21-60-00 FIG 104. REPLACE FLT DECK ZONE DUCT OVERHEAT SWITCH S21 PCN 563-004SDR CA130314013Acm · seized(CAN) DURING CRUISE AT 13,000 FT, CABIN DUCT TEMPERATURE STARTED TO RISE. QRH FOLLOWED, ACFT DESCENDED TO 10,000 FT. MAINTENANCE HAS CONFIRMED THE ACM HAD SEIZED. ACM REPLACED.SDR 29GA2010314335021Motor · shortedFLIGHT 4006. BURNING ODOR NOTICED IN CABIN, DIVERTED, TROUBLESHOOTING DISCOVERED SUPPLEMENTAL AC MOTOR BURNED, NO OTHER DEFECTS NOTED. REPLACED COMPRESSOR MOTOR OPS CHECKED SATISFACTORY.SDR UALA2013030801393Actuator · faultyFORWARD EQUIPMENT VALVE EICAS MESSAGE AND OVERHEAD ANNUNCIATOR VALVE LIGHT ILLUMINATED. REPLACED OVERBOARD EXHAUST MOTOR. OPS CHECKED GOOD.SDR AALA20130304003Switch · inoperativeLGA - CREW REPORTED LEFT PACK FAILED WITH RIGHT PACK ON MEL. EMERGENCY DECLARED FLIGHT RETURNED LGA LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED BOTH SINGLE SEGMENT SWITCHES. SYSTEM GROUND CHECK NORMAL OPERATION.SDR SIMA20130304007Acm · malfunctionedON FLIGHT 3226 THE CREW REPORTED THAT AT CRUISE THE FLIGHT CREW DETECTED TOXIC FUMES IN THE COCKPIT. THE FLIGHT ATTENDANT SMELLD FUMES IN THE FORWARD CABIN. THE FLIGHT ATTENDANT SAID THAT FUMES WERE CONCENTRATED IN THE FORWARD PART OF CABIN. THE CREW PERFORSDR CALA2013030500146Condenser · crackedLEFT TRIP LIGHT ILLUMINATED IAW QRH RESET, AT 4000 FT AGL TRIPPED AGAIN. FOUND LT PACK CONDENSER CRACKED & LEAKING. R & R LT PACK CONDENSER REF AMM 21-51-12. OPS & LEAK CHECKED NORMAL. OK FOR SERVICE.SDR DXTA2013030405305Compressor · failedAFTER ENGINE SHUTDOWN WITH THE APU RUNNING AND BOTH COCKPIT AND CABIN PACKS ON, THE ACFT STARTED HAVING SMOKE IN THE CABIN COMING OUT OF THE OVERHEAD WEMACS. THE CABIN PACK WAS TURNED OFF AND THE SMOKE SUBSIDED. INSPECTED PAC FOR CABIN (FWD) NO SIGNS OF EXTESDR ASAA2013030294061Warning Light · false activationON RECALL, RT PACK ILLUMINATED, EXTINGUISHES ON MASTER CAUTION RESET. UNABLE TO DUPLICATE DEFECT. NO RT PACK LIGHT ON MASTER CAUTION RECALL AND BITE OF NR 1 AND NR 2 ZONE TEMP CONTROLLERS SHOWED NO FAULTS WITH VERIFY TESTS PASSED. OPERATED BOTH PACKS IAW MM SDR UALA2013030401284Control Valve · faultyRIGHT A/C PACK OFF LIGHT ILLUMINATED IN AUTO AND STDBY NORMAL. RESETS BUT THEN TRIPS OFF IN BOTH. REPLACE RT A/C PACK TEMP CONTROL VALVE PER MM.SDR ASAA2013030194029Module · failedRIGHT PACK READS BELOW 0 TEMP. VERIFIED DEFECT, RT PACK TEMP READS 0 DEG(C) WHILE OPERATING. R & R AIR CONDITIONING MODULE REF MM 21-51-65. GROUND VERIFICATION TEST PASSED.SDR ASAA2013022794028Actuator · failedRIGHT PACK LIGHT ILLUMINATES ON RECALL. RESETS ON PUSHING MASTER CAUTION LIGHT. DURING TROUBLESHOOTING OF RT PACK LIGHT FOUND RT RAM AIR ACTUATOR FAILING BITE & MAKING CLUNKING NOISES WHEN REACHING FULL CLOSED POSITION. REPLACED RT RAM AIR INLET ACTUATOR. SDR USAA2013022800009A/C Pack · contaminatedFLIGHT ATTENDENT'S AND PASSENGERS REPORT A DIRTY SOCK SMELL AND TOILET SMELL (AFT RIGHT LAV FLOOR FLOODED AND LEAK SUSPECTED). MAINTENANCE COMPLIED WITH TROUBLESHOOTING CARD 26L00021001, 26L00021002 AND 26L00021004. FOUND GLYCOL INGESTION IN APU AND PACKS. SDR ASAA2013022694015Controller · inoperativeON LANDING, CHECK RECALL LT PACK ILLUMINATED, WENT OUT ON RESET. ACCOMPLISHED BITE CHECK ON LT PACK ZONE CONTROLLER. NO FAULTS FOUND. ADJUSTED RAM AIR INLET REFLECTOR DOOR & MODULATION PANELS REF AMM 21-51-22-400-803. OPS/BITE CHECKED NORMAL.SDR ASAA2013022493985Control Valve · leakingRIGHT PACK LIGHT ILLUMINATED DURING RECALL. ACFT GROUNDED. CONFIRMED FAULT, NR 2 TEMP CONTROLLER LOGGED THIS PACK TCV. ACCOMPLISHED FIM 21-62 TASK 831 RT TEMP CONTROL VALVE - FAULT ISOLATION. FOUND TCV (V141) LOOKING OVERHEATED AND LEAKING OIL. REPLACED TCSDR ASAA2013022493984Control Valve · malfunctionedDURING RECALL ON LANDING CHECKLIST RT PACK LIGHT CAME ON. ACCOMPLISHED FIM 21-62 TASK 801 PACK/ZONE TEMP CONTROLLER BITE PROCEDURE ON NR 1 AND NR 2 TEMP CONTROLLER. NR 2 TEMP CONTROLLER LOGGED THIS PACK-TCV. ACCOMPLISHED FIM 21-62, TASK 831 STEPS A THROUGHSDR UALA2013022501122Warning System · activatedFORWARD EQP VALVE EICAS MESSAGE AND OVERHEAD ANNUNCIATOR "VALVE" LIGHT IS ILLUMINATED.SDR ASAA2013022393963Acm · failedLT PACK OCCASIONALLY GOES FULL HOT ON TAXI IN, NOTED HOT ODOR THROUGHOUT ACFT THEN LT PACK TRIP OFF OCCURRED. REMOVED LT ACM REF 21-51-04-000-802-002 AND HP WATER SEPARATOR MIX BUFF REF 21-51-17-000-801. ACCOMPLISHED WITH STEP 3.G(3). REF21-51-04-400-802-002SDR ASAA2013022393962Control Valve · malfunctionedON MASTER CAUTION RECALL, RT PACK LIGHT ILLUMINATES. DID THE QRH PROCEDURE - THE RT PACK LIGHT WENT OUT ON RESET. ACCOMPLISHED ZONE TEMP CONTROLLER BITE IAW FIM 21-62, TASK 801 - NR 2 CONTROLLER SHOWED FAULT THIS PACK TCV. PERFORMED T/S FOR TCV FAULT IAW FSDR SIMA20130223001Acm · malfunctionedON FLIGHT 4126 THE CREW REPORTED LAV SMOKE ON EICAS, RAN CHECKLIST, LIGHT ON AFTER FLIGHT ATTENDANT TEST. LIGHT OUT ABOUT 2 MIN LATE ON BASE FOR RETURN LANDING. THE CREW DECLARED AN EMERGENCY AND ELECTED TO RETURN TO ORD. THE AIRCRAFT LANDED WITHOUT INCIDENSDR UALA2013022201072Acm · leakingLEFT WING BLEED LOOP, FLT DIVERTED. FOUND SEAL LEAKING WHICH IS PART OF VALVE 644-9042. ON CHECK OF THE AIR SYS, MX FOUND ACM GASKET LEAKING. ON ATTEMPTED REPAIR OF GASKET DISCOVERED THAT HELICOIL ON ACM FAILED. REPLACED LEFT ACM IAW AMM. NO LEAKS NOTED, SDR SIMA20130221005Control Valve · inoperativeFLIGHT 4570, CREW REPORTED NR 2 A/C PACK CYCLING FROM FULL HOT TO FULL COLD AND AN OILY ODOR WITH NR 2 PACK ON. REMOVED AND REPLACED THE DUEL TEMPERATURE CONTROL VALVE ON NR 2 PACK IAW AMM 21-60-01. OPS CHECKED GOOD. ACFT RETURNED TO SERVICE.SDR SIMA20130220008Condenser · inoperativeFLIGHT 4403, CREW REPORTED SMOKE IN COCKPIT AND CABIN AT TAKEOFF ROLL AND INITIAL CLIMBOUT. DECLARED AN EMERGENCY AND RETURNED TO DEPARTURE. LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. PERFORMED TROUBLESHOOTING & DISCREPANCY ISOLATED TO NR 1 ASDR ASAA2013021793909Controller · trippedLEFT PACK LT ILLUMINATES ON RECALL. INITIAL EVALUATION HAD A TCV FAULT ON NR 1 CONTROLLER. RESET CONTROLLER IAW MM 21-62 TASK 801. FAULT CLEARED.SDR UIEA2013021600089Cooling Fan · failedFWD EQUIPMENT COOLING EXHAUST FAN STATUS MESSAGE. R & R COOLING FAN IAW AMM 21-58-06/401. OPS CHECKED GOOD.SDR ASAA2013021693908Warning Light · illuminatedDURING RECALL OF MASTER CAUTION LIGHT THE RT PACK LIGHT ILLUMINATED. ON RESET LIGHT EXTINGUISHED. PERFORMED PACK/ZONE TEMP CONTROLLER BITE TEST. NR 2 CONTROLLER FLAGGED RAM AIR ACT. (RT) FAULT IS INTERMITTENT. ABLE TO CLEAR WITH VERIFY. NO HISTORY PAST 3SDR ASAA2013021693907Heat Exchanger · failedLEFT PACK LEAKING BETWEEN HEAT EXCHANGER AND PLENUM. REMOVED LT ACM IAW MM 21-51-04-000-802-002. REMOVED LT HEAT EXCHANGER/PLENUM ASSY IAW MM 21-51-03-000-805-002. REPLACED BOTH (2) PRIMARY AND SECONDARY HEAT EXCHANGERS ASSY IAW MM 21-51-03-400-804-002. RE
Back to JASC 2150