JASC 2160
Service difficulty reports · 3,040
Reports filed under 2160 · Cabin Temperature Control System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2018021123507Filter · not reportedAFT TEMP CONTROLLER WILL NOT HOLD A CONSTANT TEMP. ACFT GROUNDED. PERFORMED A CABIN TEMP CONTROL BITE NR 1 & 2 IAW FIM 21-61, TASK 801. NO FAULTS DURING BITE. REMOVED AND REPLACED THE AFT CABIN TEMP SENSOR FILTER IAW AMM 21-61-06. CABIN TEMPERATURE OPERATSDR ASAA2018021023472Control Valve · faultedCONTROL CABIN ZONE TEMP LIGHT ON CLIMB OUT. RESET WITH MASTER CAUTION RECALL. ACFT GROUNDED. REPLACED CONTROL TRIM VALVE IAW AMM 21-61-21-000-801, AND 21-61-21-400-801, OPS CHECKED GOOD.SDR ASAA2018020823475A/C Pack · unknownMIDWAY THRU FLIGHT, THE F/A COMPLAINED OF EXCESSIVE CABIN HEAT, HAD TO POSITION THE FWD & AFT CABIN TEMP CONTROLS TO THE FULL COLD STOP, ANYTHING ABOVE THAT WOULD CAUSE EXCESSIVE HEAT. OPS WORKING NORMAL. ACFT GROUNDED. PERFORMED A CABIN TEMP CONTROLLER BSDR ASAA2018020823473Controller · failedCONTROL CABIN HEAT KNOB FULL HOT, COCKPIT VERY COLD. ACFT GROUNDED. PERFORMED NR 1 AND 2 PZTC BITE CHECKS. NO FAULTS FOUND IAW AMM 21-61-00. SWAPPED THE NR 1 PZTC (M1442) AND 2 PZTC (M1443) POSITIONS. REMOVED AND REPLACED THE NR 1 PZTC (M1442). OPS CHECKSDR ASAA2018020523431Sensor · dirtyCONTROL CABIN AIR TEMP IS VERY COLD. TEMP CONTROLLER HAS NO NOTICEABLE EFFECT ON AIR TEMP, EXCEPT WHEN TRIM AIR SWITCH IS OFF. WITH TRIM AIR OFF, TEMP CONTROLLER SEEMS TO WORK NORMALLY. ACFT GROUNDED. PERFORMED A BITE CHECK OF THE NR 1 AND 2 PFTC IAW AMM 2SDR ASAA2018020323375Warning Light · illuminatedON RECALL BOTH CONT AND ZONE TEMP LIGHTS CAME ON THEY BOTH EXTINGUISHED ON RECALL. ACFT GROUNDED. OPERATED BOTH PACKS FOR OVER AN HOUR PER B737-900 AMM 21-00-00/201. NO DEFECTS NOTED WITH EITHER CONT CABIN OR AFT CABIN ZONES. PRESSURIZED THE AIRCRAFT AND THE SDR ASAA2018020223386Module · faultyON TAXI, AFT CAB ZONE TEMP LIGHT ILLUMINATES, RESETS WITH MASTER CAUTION. GROUNDED - YES. REMOVED AND REPLACED AIR CONDITIONING MODULE REF AMM 21-51-65. OPS TEST NORMAL PER SAME, NO FAULTS.SDR ASAA2018020223384Warning Light · false activationCRUISE FLIGHT AT FL 340 THE AFT CABIN ZONE TEMP LIGHT CAME ON, TEMP RESPONDS NORMALLY. SUPPLY TEMP IS NORMAL, FOLLOWED THE QRH. LATER IN THE FLT THE ZONE TEMP LIGHT FLICKERED FOR A WHILE AND LATER WENT OUT. GROUNDED - YES. WAS ABLE TO DUPLICATE "FLICKERING" OFSDR ASAA2018020223379Control Valve · faultedAFT CABIN ZONE TEMP LIGHT ILLUMINATED WITH MASTER CAUTION RECALL EXTINGUISHES WHEN MASTER CAUTION SYSTEM IS RESET. ACFT GROUNDED. PERFORMED PACK TEMP CONTROL BITE PROCEDURE FIM 21-62 TASK 801. LT PACK ZONE TEMP CONTROLLER SHOWS TRIM VALVE FAULT. RESET FAUSDR ASAA2018020123363Warning Light · false activationAFT CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL, EXTINGUISHED ON MASTER CAUTION RESET. AFT TEMP NORMAL. ACFT GROUNDED. PERFORMED BITE PROCEDURE FOR PACK/ZONE TEMP IAW AMM 21-61-00-700-806-002, FAULT CLEARED ON RECALL, NO HISTORY LAST 30 DAYS. GROUND VERIFICATSDR ASAA2018020123362Filter · dirtyDURING DESCENT, THE AFT ZONE TEMP LIGHT ILLUMINATED. RAN QRH, LIGHT REMAINED ILLUMINATED. ACFT GROUNDED. FWD CARGO HEAT DUCT OPENED, PACK AIRFLOW SHUTOFF VALVE ACTIVATED AND OPENED IAW AMM 21-00-00. ACCOMPLISHED CABIN TEMP CONTROL AND INDICATION IAW AMSDR ASAA2018013123364A/C Pack · malfunctionedCONTROL CABIN TEMP CONTROLLER HAS NO EFFECT ON DUCT TEMP. MAKING FLIGHT DECK COLD AT ALTITUDE. STUCK AT DUCT TEMP 28 DEGREES CELSIUS. ACFT GROUNDED. ACCOMPLISHED CABIN TEMP CONTROL + INDICATION OPS TEST IAW AMM 21-61-00-700-807-002. COULD NOT DUPLICATE ISSUESDR ASAA2018013023326Warning Message · illuminatedAFTER PUSH BACK, ZONE TEMP FOR CONTROL CABIN ON RECALL AND EXTINGUUISHED ON MASTER CAUTION PUSH TO RESET. ACFT GROUNDED. NR 2 PACK/TEMP CONTROLLER SHOWS FLT DECK TRIM VALVE FAULT ON BIT & PREV FLT. VERIFY PASSED. RESET FAULTS. FAULT DID NOT RETURN. IAW AMMSDR ASAA2018012923317Valve · faultedCONTROL CABIN ZONE LIGHT ILLUMINATED. ACFT GROUNDED. REMOVED AND REPLACED THE FLIGHT DECK TRIM VALVE IAW AMM 21-61-21, BITE CHECK PASSED AND NO DEFECTS NOTED IAW AMM TASK 21-61-00-700-806-002.SDR ASAA2018012823320Filter · dirtyCONTROL CABIN ZONE TEMP ILLUMINATED WITH MASTER CAUTION RECALL AND DOES RESET. ACFT GROUNDED. PERFORMED A PACK TEMPERATURE CONTROL BITE PROCEDURE IAW FIM 21-62, TASK 801. RIGHT PACK/ZONE TEMPERATURE CONTROLLER LOGGED A FLT DECK TRIM VALVE FAULT FOR BITE ANDSDR ASAA2018012723295Control Valve · failedRIGHT STBY TEMP CONTROL VALVE FAILED AN OPS TEST IAW AMM 21-51-11-400-801. ACFT GROUNDED. REMOVED AND REPLACED THE RT TEMP STANBY CONTROL VALVE IAW AMM 21-51-11. OPS TESTED GOOD.SDR ASAA2018012523299Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT COMES ON WITH RECALL, EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED A PACK, ZONE TEMP CONTROL BITE, CLEARED. CONTROL CABIN TRIM VALVE FAULT. TEST PASSED. GROUND VERIFICATION SUCCESSFUL.SDR ASAA2018012423276Warning System · false activationCONT CAB ZONE TEMP LIGHT ILLUMINATED DURING CLIMB FOLLOWED QRH. AFTER 10+ MINUTES WAITING FOR DUCT TO COOL, STILL UNABLE TO RESET ZONE TEMP LIGHT. SUPPLY DUCT TEMPERATURE APPEARS NORMAL. GROUNDED - YES. PERFORMED PACK TEMP CONTROL BITE PROCEDURES PER B737-800 SDR ASAA2018012223262Warning Light · false activationAFTER PUSHBACK ZONE TEMP FOR CONTROL CABIN ILLUMINATED. RESET ON MASTER CAUTION. ACFT GROUNDED. PERFORMED A PACK TEMP CONTROLER BITE CHECK IAW FIM 21-62, TASK 801. NR 2 PACK TEMP CONTROLLER FAULTED CONTROL CABIN TRIM VALVE. RESET, RAN BITE CHECK AGAIN & NOSDR ASAA2018012023225Unknown · malfunctionedFWD CABIN ZONE TEMP LIGHT IS ON. WILL NOT CANCEL. GROUNDED - YES. ACCOMPLISHED TEMP CONTROLLER BITE, NO FAULTS LOGGED AND VERIFY TEST OPS NORMAL. CYCLED A/C POWER, FWD CABIN ZONE TEMP LIGHT REMAINED EXTINGUISHED. REPLACED CABIN ZONE TEMP SELECTOR PANEL PRECAUTSDR UIEA2018012200099Switch · damagedTEMPERATURE CONTROL PANEL, TRIM AIR SWITCH BINDING. REMOVED AND REPLACED THE TRIM AIR SWITCH IAW SPM 20-84-13.SDR ASAA2018011623191Filter · dirtyCOCKPIT TEMP ERRATIC. KNOB POSITION AND DUCT TEMP DO NOT CORRELATE. DURING CRUISE WITH OAT -54C. ACFT GROUNDED. IAW AMM 21-61-00-700-807-002, CABIN TEMP CONTROL & INDICATION OPS TESTED. COULD NOT DUPLICATE. OPS TESTED NORMAL. CLEANED FLT DECK TEMP SENSOR SDR ASAA2018011423153Control Valve · failedCONTROL CABIN TEMP HARD TO CONTROL. LEFT PACK TEMP INDICATES 80 DEG C. ACFT GROUNDED. FOUND LEFT PACK TEMP CONTROL VALVE V00139 STUCK IN OPEN POSITION. REMOVED AND REPLACED LEFT PACK TEMP CONTROL VALVE IAW AMM 21-61-21-000-801, AND 21-61-21-400-801. LEAK CSDR ASAA2018011323152Warning Light · false activationON RECALL, CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED. DUCT TEMP NORMAL. LIGHT EXTINGUISHED ON RESET. ACFT GROUNDED. PERFORMED AMM 21-61-00, SHOWED THE NR 2 CONTROLLER FLT DECK LT ZONE TEMP. RESET AND REPERFORMED BITE, ALL PASSED, NO FAULTS AND NO HISTORYSDR ASAA2018011223148Warning Light · false activationILLUMINATION OF CONTROL CABIN ZONE TEMP LIGHT ON MASTER CAUTION RECALL. LIGHT EXTINGUISHED WHEN MASTER CAUTION SYSTEM IS RESET. ACFT GROUNDED. PERFORMED THE PACK/ZONE TEMP CONTROLLER BITE TEST IAW AMM 21-51-00-700-803. ONE INTERMITTENT FAULT FOUND FOR THE SDR ASAA2018010923123Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL. RESET WITH THE MASTER CAUTION. ACFT GROUNDED. BITE CHECKED THE RT ZONE TEMP CONTROLLER IAW FIM 21-62 TASK 801. FAULTED FLT DECK TRIM VALVE. RAN VERIFY TEST THREE TIMES IAW FIM 21-62 TASK 832, FAULT CLEASDR P5CA2018010500002Warning Message · false activationEICAS FWD CARGO BACKUP. PERFORMED FWD CARGO AIR CON TEST IAW AMM 21-28-00. CHECKED OK AND BITE CHECKED THE AUX TEMP CONTROLLER NO FAULTS IAW FIM 21-61-FT 812.SDR ASAA2018010323074Controller · faultedCONTROL CABIN ZONE TEMP ILLUMINATED, RAN QRH. THE LIGHT EXTINGUISHED BUT ILLUMINATED ON RECALL. TEMP NORMAL. ACFT GROUNDED. ACCOMPLISHED A BITE CHECK ON THE NR 1 & 2 CONTROLLERS, NR 1 GOOD, NR 2 FAULTED FOR FLT DECK TRIM VALVE. RESET THE NR 2 CONTROLLER,SDR UIEA2018010300007Warning Light · false activationAFT CABIN TEMP INOPERATIVE. HTC AND MESSAGE RESET IN FLT, NO FAULTS ON TEMP CONTROL BOX IAW AMM 21-51-00.SDR ASAA2018010123066Knob · looseCABIN AIR TEMP DISPLAY SELECT KNOB LOOSE. ACFT GROUNDED. VIERIFIED DEFECT, REMOVED AND REPLACED THE CABIN TEMP SELECTOR P5-17 PANEL IAW AMM 21-61-00, OPS CHECKED NORMAL.SDR ASAA2018010123039Warning Light · false activationCABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL. RESET. ACFT GROUNDED. FAULT CODE 216-211-00. INITIAL EVALUATION FOUND THE NR 2 TEMP CONTROLLER SHOWING FLT DECK TRIM VALVE FAULT. PERFORMED FIM 21-62 TASK 842. NOTED ON RESETTING THE NR 2 TEMP CONTROLLER, RAN FISDR UIEA2018010200003Sensor · failedLEFT PACK TEMP CONTROL BITE TEST FAILED. REMOVED AND REPLACED THE PACK AIR TEMP SENSOR ASSY IAW AMM 21-51-04, OPS CHECKED NORMAL.SDR ASAA2017123123038Control Valve · malfunctionedAFT ZONE TEMP LIGHT ILLUMINATED WITH PACKS ON. DID NOT OCCUR ON RECALL. COMPLIED WITH QRH, DID NOT RESET. ACFT GROUNDED. AT DISCONNECT D3996 PIN 20, FOUND GROUNDED. REMOVED D646 AT AIR CON PANEL AT P5, NO HELP. REMOVED M1455 AT E4-1, LIGHT EXTINGUISHED SDR ASAA2017123023041Controller · faultedDURING FLIGHT THE AFT CABIN ZONE TEMP AMBER LIGHT ILLUMINATED. FOLLOWED QRH PROCEDURE AND THE LIGHT DID NOT EXTINGUISH WHEN MASTER CAUTION WAS RESET. THE DUCT TEMP WAS CONTROLLABLE. ACFT GROUNDED. VERIFIED DEFECT OF THE AFT CABIN ZONE LIGHT REMAINS ILLUMINSDR ASAA2017122923037Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL AND EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. REACTIVATED THE FLT DECK TRIM AIR MODULATING VALVE. FLT DECK TEMP CONTROL OPERATED NORMAL..SDR ASAA2017122823020Warning Light · false activationCONTROL CAB ZONE TEMP LIGHT ILLUMINATED WITH MASTER CAUTION RECALL. LIGHT EXTINGUISHED WITH MASTER CALL RESET. TEMP CONTROL FOR CONTROL CABIN IS OPERATIVE. ACFT GROUNDED. ACCOMPLISHED PACK ZONE TEMP CONTROL BITE CHECK. NR 1 CONTROLLER PASSED, NO FAULTS NOTSDR UIEA2017122402431Warning Light · false activationFLIGHT DECK TEMPPERATURE LIGHT ILLUMINATED ON OVERHEAD PANEL. PERFORMED FIM 21-61-00 FT 815 FOUND ZONE TEMP CONTROLL OPERATING NORMAL BITE CHECK OK AND VALVE FOLLOWS SWITCH IN FLIGHT DECK AND ON EICAS ECS PAGE.SDR ASAA2017122222981Control Valve · failedDURING DESCENT CHECKLIST, CONTROL CAB ZONE TEMP LIGHT ILLUMINATED DURING RECALL. CANCELS DURING MASTER CAUTION RESET. ACFT GROUNDED. CONFIRMED FAULT, NR 2 PACK/ZONE TEMP CONTROLLER BITE IAW AMM 21-61-00-700-806-002 SHOWS (V143), FLIGHT DECK TCV FAILED. REMOVSDR ASAA2017122022963Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED, EXTINGUISHED WITH M/C RESET. ACFT GROUNDED. ACCOMPLISHED PACK TEMP CONTROL BITE IAW FIM 21-61 TASK 801. LAST FLIGHT SHOWS TRIM VALVE FAULT. VERIFY SHOWS NO CURRENT FAULTS. RESET, CONTROL CABIN TEMP OPS NORMAL. GRSDR ASAA2017121922953Warning System · false activationAFTER ENGINE START AND CONFIGURING AIR CONDITIONING. CONT CABIN ZONE TEMP LIGHT ILLUMINATED EXTINGUISHED ON RESET. GROUNDED - YES. PERFORMED NR 1 & NR 2 PACK TEMP CONTROL BITE CK'S REF FIM 21-62 TASK 801. NO FAULTS NOTED. PERFORMED FIM 21-61 TASK 861 & CONTROLSDR ASAA2017121822952Warning System · false activationZONE TEMP FOR CONTROL CABIN ILLUMINATED ON RECALL EXTINGUISHED WITH MASTER CAUTION RESET. GROUNDED - YES. INITIAL EVALUATION FOUND NR 2 TEMP CONTROLLER WITH FLT DECK TCV FAIL. PERFORMED BITE TEST REF AMM TASK 21-61-00-700-806-002. NO FAULT FOUND. RESET CONTROLSDR ASAA2017121722943Controller · malfunctionedFLIGHT DECK TEMP GRADUALLY COOLING, WARM AIR NOT AVAILABLE WHEN SELECTING CONTROL CABIN TEMP SELECT KNOB TO WARMER TEMPERATURE. MOVING THE TEMP SELECT KNOB FULL HOT TO FULL COLD. NEEDLE ONLY MOVES +/- 2 DEGREES, NO WARM AIR FROM FOOT AIR VALVES. ACFT GROUNDESDR JIKA2017121501Circuit Breaker · trippedTHE PILOT WAS ON CLIMB-OUT FROM KPHX WHEN THE ENVIRONMENTAL SYSTEM BEGAN TO BLOW VERY HOT AIR FROM THE VENTS AND THE RIGHT WING OVERHEAT ANNUNCIATOR ILLUMINATED. THE PILOT FOLLOWED PROCEDURES TO REDUCE THE WING OVER HEAT CONDITION AND THE LIGHT EXTINGUISHED. SDR J7SA20171215001Control Valve · malfunctionedATB AFTER RECEIVING CABIN DUCT OVER-TEMP DURING CLIMB FOLLOWED BY SMOKE ENTERING THE CABIN WHEN ENGINE POWER WAS INCREASED. PERFORMED OVER-TEMP CHECKLIST AND SMOKE CLEARED. AIRCRAFT LANDED WITHOUT INCIDENT. REPLACED SUSPECT CABIN TEMP CONTROL VALVE AND INOP CSDR ASAA2017121422899Warning Light · false activationCONTROL CABIN ZONE TEMP ILLUMINATES W/MASTER CAUTION LIGHT WHEN RECALL IS DEPRESSED, LIGHT EXTINGUISHES WHEN RESET. GROUNDED - YES. RELEASED PER MEL 21-21F, CONTROL CABIN PRIMARY CONTROL INOP. PERFORMED PACK ZONE TEMP CONTROLLER BITE PER B737-800 AMM 21-61-00-SDR ASAA2017121322900Control Valve · failedON M/C RECALL CONT CAB TEMP AND AIR COND MASTER CAUTION LTS ILLUMINATE. BOTH LTS EXTINGUISH WHEN MASTER CAUTION PANEL RESET. GROUNDED - YES. RELEASED PER MEL 21-21F FLIGHT DECK TEMP CONTROLLER SYSTEM INOO. ACCOMPLISHED PACK/ZONE TEMPERATURE CONTROLLER BITE TESSDR ASAA2017121322879Control Valve · faulted"CONT CAB" ZONE TEMP LIGHT ILLUMINATES ON RECALL AND EXTINGUISHES WITH MASTER CAUTION RESET. GROUNDED - YES. REMOVED AND REPLACED FLT DECK TCV REF B737-900 AMM 21-61-21-400-801, BITE TEST ON THE PACK/ZONE TEMP CONTROLLERS OK. LEAK CHECK OK. A/C RELEASED FROM MSDR ASAA2017121222865Warning Light · false activationON RECALL - CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED. GROUNDED - YES. PERFORMED BITE ON #1 & #2 PACK TEMP CONTROLLERS, #2 TEMP CONTROLLER SHOWS FLT DECK TRIM VALVE FAULT PER B737-900 FIM 21-62 TASK 801, PERFORMED PACK CONTROLLER RESET, PERFORMED BITE ON #1 & SDR ASAA2017121122866Ecs · malfunctionedPASSENGER CABIN WAS EXCESSIVELY WARM IN FLIGHT WITH FWD CAB AND AFT CAB IN RELATIVELY NORMAL POSITIONS. TURNED FWD CAB AND AFT CAB CONTROLLERS WAY DOWN BUT PAX CABIN REMAINED WARM. REFERENCED QRH PROCEDURE AND TURNED TRIM AIR SWITCH OFF PAX CABIN TEMPERATURE GSDR UIEA2017120902382Ecs · malfunctionedAFT CABIN TEMP CONTROL INOP(<P>TRANSFERRED TO MDDR 87017 PER MEL 21-61-04-02 CAT C DUE 19DEC17</P><P>REACTIVATED VALVE AND OPS CHECK SYSTEM PER AMM 21-61-00 ZONE TEMP OPS CHECK. ALL OPS CHECK NORMAL MDDR 87017 CLEARED.</P>)
Back to JASC 2160