JASC 2160
Service difficulty reports · 3,040
Reports filed under 2160 · Cabin Temperature Control System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2017020200142Valve · malfunctionedPER CREW REPORT COCKPIT TRIM AIR VALVE HAS FAILED MULIPLE TIMES AND THEN STARTED WORKING AGAIN ON LAST FEW LEGS. REMOVED AND REPLACED FLT DECK ZONE TRIM AIR MODULATING VALVE IAW AMM 21-61-07 OPS CHECKED NORMAL.SDR ASAA2017020119636Warning Light · false activationZONE TEMP ON RECALL. ACFT GROUNDED. ACCOMPLISHED PACK TEMP CONTROL BITE IAW FIM 21-62 TASK 801, ZONE TEMP CONT 2 FAULTED (TRIM VALVE-FLT DECK), CLEARED FAULT, TESTED TWO MORE TIMES FAULT DID NOT RETURN, NO HISTORY 60 DAYS.SDR KY7A20171018004Mixing Valve · crackedFLIGHT CREW REPORTED RH WING OVERHEAT WARNING ILLUMINATED DURING FLIGHT. MX FOUND CRACKED MIXING VALVE AND REPLACED.SDR UIEA2017013100126Filter · dirtyMID CABIN ZONE TEMP INOPERATIVE. CLEANED ALL AIRCRAFT ZONE TEMP SENSOR FILTERS IAW AMM 21-61-09. MID CABIN ZONE TEMP NORMAL, NO FAULTS IAW AMM 21-61-00 .SDR ASAA2017012819562Warning Light · false activationAFTER STARTUP CONTROL CAB ZONE TEMP LIGHT CAME ON AND WOULD NOT EXTIGUISH AFTER CHECKLIST. ACFT GROUNDED. PERFORMED FIM 21-61 TASK 861. BITE TEST OF NR 1 AND 2 TEMP CONTROLLERS SHOWS NO FAULTS. RAN PACKS AND CONT CABIN TEMP ADJUSTS NORMALLY. BITE TESTED AGAIN SDR ASAA2017012719561Filter · cloggedDURING MASTER CAUTION RECALL AFT CAB ZONE TEMP LIGHT ILLUMINATES. LIGHT EXTINGUISHES WHEN MASTER CAUTION RESET IS PUSHED. GROUNDED - YES. BITE SHOWS TEMP SENSOR FAULT. FOUND AFT CABIN TEMP SENSOR FILTER CLOGGED. CLEANED FILTER IAW AMM TASK 21-61-06-100-801. BISDR P5CA2017012700046Valve · out of toleranceFOUND FWD TRIM VALVE POSITION INDICATION ON EICAS 25 OFF SCALE. REPLACED THE VALVE IAW AMM 21-61-07-004-001-003, REV 120 AND AMM 21-61-07-404-011-003, REV 120. CHECKED NORMAL.SDR P5CA2017012700047Valve · out of toleranceFOUND AFT TRIM VALVE POSITION INDICATION ON EICAS 25 OFF SCALE.SDR ASAA2017012219510Warning Light · false activationON RECALL, ZONE TEMP LIGHT ILLUMINATED. DEPRESSING MASTER CAUTION RESETS THES LIGHT. ACFT GROUNDED. ACCOMPLISHED FIM 21-62 TASK 848 AND FIM 21-62 TASK 801 BITE, NO FAULTS.SDR ASAA2017011919475Control Valve · failedDURING CLIMB OUT, CONTROL CABN ZONE TEMP ILLUMINATED BUT EXTINGUISHED WITH MASTER CAUTION RESET. PERFORMED QRH ITEMS TO POINT WHETHER IT STATES, "NO FURTHER ACTION REQUIRED". ACFT GROUNDED. REPLACED THE CONTROL CABIN TRIM VALVE (V143) IAW AMM TASK 21-61-21-40SDR UIEA2017011900078Warning Message · false indicationEICAS MESSAGE FOR MID CABIN TEMP, MID CABIN CONTROLLER INOPERATIVE. RESET CABIN TEMP CONTROLLER IAW AMM 21-61-00. OPS CHECKED GOOD.SDR ASAA2017011919474Warning Light · false activationCONTROL CAB ZONE TEMP ON RECALL EXTINGUISHES ON MASTER CONTROL RESET. GROUNDED - YES. ACCOMPLISHED PACK/ZONE TEMPERATURE CONT BITE TEST, FLT DECK TRIM VALVE FAULTED. RESET FAULT, SYSTEM OPS NORMAL IAW AMM 21-61-00-700-806-002. OK FOR SERVICE.SDR ASAA2017011919473Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT LUUMINATEED ON MASTER CAUTION TEST. EXTINGUISHES WITH RESET. ACFT GROUNDED. PERFORMED PACK TEMP CONTROL BITE PROCEDURE IAW FIM 21-62 TASK 801. NO EXISTING FAULTS FOUND. FAULT HISTORY SHOWED F/N SELECTOR FAULT 21-51311 LATCHED ON BSDR ASAA2017011919472Controller · faultedAFT CAB ZONE TEMP ON RECALL. ACFT GROUNDED.SDR ASAA2017011919471Controller · faultedCONTROL CABIN ZONE TEMP ON RECALL. ACFT GROUNDED.SDR ASAA2017011919470Controller · faultedON RECALL RECEIVED A LEFT PACK LIGHT. ACFT GROUNDED. LEFT PACK PRIMARY NR 1 ZONE TEMP CONTROLLER FAULT. REPLACED THR NR 1 ZONE TEMP CONTROLLER IAW AMM 21-61-20, BITE CHECKED NORMAL IAW FIM 21-62 TASK 802.SDR ASAA2017011919469Valve · faultedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED DURING RECALL. ACFT GROUNDED. ACCOMPLISHED A PACK TEMP CONTROL BITE IAW FIM 21-62 TASK 801. FOUND FLT DECK TRIM VALVE FAULT LATCHED. RESET LATCH. OPS NORMAL.SDR ASAA2017011719425Controller · false indicationAFTER STARTING BOTH ENGINES & PUSHING THE RECALL BUTTON, WE NOTICED A MASTER CAUTION CONT CAB ZONE TEMP LIGHT. WE RAN THE CHECKLIST FOR THIS LIGHT & CALLED MX CONTROL. WE THEN EXECUTED A FLIGHT CREW PLACARD. ACFT GROUNDED. NR 2 TEMPERATURE CONTROLLER LOGGED FSDR UIEA2017011500041Controller · faultedMID CABIN TEMP EICAS. BITE CHECKED THE AUX TEMP CONTROLLER IAW AMM 21-61-00. MID CABIN TEMP FAULT. CLEARED FAULT & OPS TESTED GOOD. NO FAULTS. GREEN GO LIGHT. COOLING PACK SYSTEM OPS GOOD IAW AMM 21-51-00.SDR P5CA2017011300024Controller · malfunctionedUNABLE TO CONTROL FWD AND AFT CABIN TEMPERATURE CONTROLLERS, TEMP WAS 27* ON FULL COLD. BOTH PACK OPERATION CHECKED NORMAL IAW AMM 21-51-00 / 001.SDR DALA2017010900218Controller · malfunctionedDURING DEPARTURE, THE "NO MODE" LIGHT ILLUMINATED ON THE THRUST RATING PANEL IN CLIMB MODE AND THE "FLOW" LIGHT ILLUMINATED ON OVERHEAD PANEL. THE CABIN WOULD NOT PRESSURIZE. AN AIR TURN BACK WAS PERFORMED. AT GATE THE LEFT PACK WENT TO UN-COMMANDED FULL HOTSDR ASAA2017010519248Warning Light · false activationCONTROL CABIN ZONE TEMP ILLUMINATED ON RECALL, RESET NORMALLY. ACFT GROUNDED. PACK/ZONE TEMPERATURE CONTROLLER BITE TEST DONE IAW AMM 21-61-00-700-806-002. NO FAULTS FOUND.SDR ASAA2017010119197Fan · failedCONT CAB OFF TEMP KNOB OFF ONLY WAY TO COOL FLT DECK 47 DEGREES C STAYED AT WHEN ON COLD OR AUTO. GROUNDED - YES. COCKPIT ZONE TEMP SENSOR FAN IS INOPERATIVE, C/B IS IN. REPLACED CONTROL CAB TEMP SENSOR FAN REF AMM 21-61-11. OPS NORMAL REF AMM 21-61-00. CONTROSDR AALA20170104024Thermostat · faultyAIRCRAFT WAS GROUNDED. WHILE ADVANCING THROTTLES, THE LEFT AIR CONDITIONING SUPPLY TEMPERATURE HIGH LIGHT ILLUMINATED. TAKEOFF WAS ABORTED, AIRSPEED ATTAINED WAS 0. REMOVED AND REPLACED LEFT PNEUMATIC AIR CONDITIONING CONTROL THERMOSTAT IAW AMM 21-61-07 AND LSDR ASAA2016123019196Filter · contaminatedON RECALL FLIGHT DECK ZONE TEMP LIGHT ILLUMINATED. LIGHT EXTINGUISHED ON MASTER CAUTION RESET. GROUNDED - YES. ACCOMPLISHED AMM TASK 21-61-00-700-806-002 PACK/ZONE TEMPERATURE CONTROLLER BITE TEST. NR 2 CONTROLLER SHOWS FLIGHT DECK ZONE TEMP LIGHT. ACCOMPLISHESDR ASAA2016122819176Control Valve · faultedRIGHT PACK LIGHT ILLUMINATED AFTER ROTATION. RAN QRH, TRIP RESET PUSHED, RIGHT PACK LIGHT EXTINGUISHED. ACFT GROUNDED. RT PACK/ZONE TEMP CONTROLLER BITE SHOWS PACK TCV (V141) FAULT. REMOVED & REPLACED THE RT PACK TCV IAW AMM TASK 21-51-10, LEAK & OPS CHECKEDSDR UIEA2017010300005Regulator Valve · malfunctionedPACK AUTO CONTROL DRIVES TEMP TO FULL COLD -15C. REMOVED & REPLACED THE TRIM AIR PRESSURE REGULATOR VALVE OPS & LEAK CHECKED GOOD IAW AMM 21-61-06-404-020.SDR UIEA2016122401052Unknown · malfunctionedCOCKPIT TEMP CONTROL GOES FULL HOT & FULL COLD, AUTO REGULATION INOPERATIVE. PERFORMED TEMP CONTROL SYS ADJUSTMENT AND TEST, SYS FUNCTIONS NORMAL IAW AMM 21-61-00/501.SDR ASAA2016122319133Warning Light · false activationDURING MASTER CAUTION RECALL, CONTROL CABIN, FWD, AND AFT CABIN ZONE TEMP LIGHTS ILLUMINATED. ON MASTER CAUTION RESET, ALL THREE ZONE TEMP LIGHT EXTINGUISHED. ACFT GROUNDED. BITE OF NR 1 & 2 PACK ZONE TEMP CONTROLLERS SHOW FLT DECK & SELECTOR FAULTS FOR PRESDR ASAA2016122219132Knob · bindingAIR TEMP GAUGE SELECTOR KNOB IS VERY HARD TO TURN. ACFT GROUNDED. CONFIRMED FAULT, REMOVED & REPLACED P5-17 TEMPERATURE CONTROL MODULE IAW AMM 21-61-15, OPS CHECKED NORMAL.SDR CVGA20161223001Control Valve · failedTWO MINUTES AFTER TAKE OFF, RECEIVED AN EICAS AMBER DUCT O'TEMP CABIN LIGHT. REFERRED TO THE QRH EMERGENCY/ ABNORMALS CHECKLIST. AFTER COMPLETING THE CHECKLIST THE DUCT OVERTEMP CABIN LIGHT REMAINED ILLUMINATED AND THE CREW WAS UNABLE TO CONTROL THE CABIN HEATSDR ASAA2016122019106Warning Light · false activationZONE TEMP LIGHT ILLUMINATED, WILL NOT RESET. ACFT GROUNDED. PERFORMED FIM 21-61 TASK 861. CHECKED GOOD. NO FAULT NOTED. OPS NORMAL.SDR ASAA2016121919096Valve · failedCONTROL CABIN ZONE TEMP ON RECALL RESETS WITH MASTER CAUTION. ACFT GROUNDED. REMOVED AND REPLACED THE LEFT ECS FWD TRIM AIR MODULATING VALVE IAW AMM 21-61-09. LEAK CHECKED PASSED. ACCOMPLISHED PACK/ZONE TEMP BITE TEST IAW AMM 21-51-00. NR 2 FAULTED CONTROL SDR UIEA2016121901031Controller · malfunctionedTEMP NOT CONTROL IN AUTO. REMOVED AND REPLACED THE ZONE TEMP CONTROLER IAW AMM 21-61-03 OPS TEST OK.SDR ASAA2016121519051Sensor · faultedUNABLE TO CONTROL TEMP IN CABIN FROM ROW 6-11, EITHER TOO HOT OR TOO COLD. ACFT GROUNDED. PERFORMED NR 2 (RT) TEMP CONTROLLER BITE CHECK AND FOUND CABIN SENSOR ZONE FAULT IAW FIM 21-61 TASK 801. CLEANED CABIN TEMP SENSOR FILTERS IAW AMM 21-61-06 AND CLEANED CASDR AALA20161216011Sensor · faultyDURING CRUISE RECIEVE A "L PACK TEMP" EICAS MESSAGE. ACCOMPLISHED QRH CHECKLIST AND TURNED LEFT PACK OFF. EMERGENCY DECLARED. RETURNED TO FIELD. AIRCRAFT WAS GROUNDED. MAINTENANCE REMOVED AND REPLACED COMPRESSOR OUTLET SENSOR IAW AMM 21-51-06, TEMPURATURE COSDR AALA20161216010Valve · faultyDURING CRUISE RECIEVE A "L PACK TEMP" EICAS MESSAGE. ACCOMPLISHED QRH CHECKLIST AND TURNED LEFT PACK OFF. EMERGENCY DECLARED. RETURNED TO FIELD. AIRCRAFT WAS GROUNDED. MAINTENANCE REMOVED AND REPLACED COMPRESSOR OUTLET SENSOR IAW AMM 21-51-06, TEMPURATURE COSDR AALA20161215034Sensor · faultyDURING CRUISE RECIEVE A "L PACK TEMP" EICAS MESSAGE. ACCOMPLISHED QRH CHECKLIST AND TURNED LEFT PACK OFF. EMERGENCY DECLARED. RETURNED TO FIELD. AIRCRAFT WAS GROUNDED. MAINTENANCE REMOVED AND REPLACED COMPRESSOR OUTLET SENSOR IAW AMM 21-51-06, TEMPURATURE COSDR UIEA2016121301017Warning Bell · false activationFWD EQUIPMENT COOLING WARNING CHIMES, EQUIPMENT COOLING OVERBOARD CLOSED ON GROUND. RECYCLED OVERBOARD EXHAUST VALVE, PERFORM OPS CHECK OF EQUIPMENT COOLING IAW AMM 21-58-00.SDR ASAA2016121219019Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. FLIGHT DECK TRIM VALVE FAULT NR 2 ZONE TEMP CONTROLLER. RESET & BITE TESTED NORMAL IAW AMM 21-61-00.SDR ASAA2016121219018Knob · looseAIR TEMPERATURE SOURCE SELECTOR KNOB ROTATES WITHOUT CHANGING SOURCE. GROUNDED - YES. REMOVED TEMP CONTROL MODULE, TIGHTENED TEMP SELECT KNOB AND REINSTALLED MODULE PER B737-800 AMM 21-61-15, OPS CHECK GOOD, REF B737-800 AMM 21-61-00-700-807-002.SDR ASAA2016121119004Warning Light · false activationZONE TEMP CONT CAB LIGHT ILLUMINATES ON MASTER CAUTION RECALL AND EXTINGUISHES ON MASTER CAUTION RESET. ACFT GROUNDED. ZONE TEMP CONT 2 BITE FAILS FLIGHT DECK TRIM VALVE. OPERATED FLIGHT DECK TEMPERATURE CONTROL, BITE CHECK TRIM AIR VALVE AND CABIN TEMP CONTROSDR ASAA2016121119003Warning Light · false activationWHILE PERFORMING ETOPS PDC FOUND CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED. ABLE TO RESET. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE TEST IAW AMM TASK 21-61-00-700-806--002 ON BOTH CONTROLLERS. NO FAULTS NOTED. NO FAULT LAST FLIGHT. OPS CHECK SDR IPXA2016121111586Valve · inoperativeFWD EQUIPMENT OVERHEAT MESSAGE AND LIGHT WITH FWD EQUIPMENT OVERBOARD EXHAUST VALVE . RETURNED TO DEPARTURE. R & R OVERBOARD EXHAUST VALVE IAW AMM 21-58-05/401. OPS CHECKED SATISFACTORY.SDR P5CA2016121000321Filter · dirtyFLT DECK TEMP CONTROL INOPERTIVE IN MANUAL OR AUTO. CLEANED THE FLT DECK TEMP SENSOR AIR FILTER, OPS NORMAL IAW AMM 21-61-00.SDR ASAA2016120918980Switch · unsecureTEMP GAUGE IN CONTROL SETTING READS 100 DEGREES C. TAPPING THE SELECTOR CHANGES THE READING TO VARIOUS READINGS 40C, 60C. ACTUAL TEMP IS NORMAL. ACFT GROUNDED. CONFIRMED FAULT, TEMPERATURE GAUGE POINTER FLUCTUATES WHEN TEMP SELECTOR SWITCH MOVED. FOUND CABISDR ASAA2016120918979Controller · faultedON RECALL CHECK DURING AFTER START, RECEIVED AN AIR CONDITIONING ANNUNCIATOR AND ALL 3 ZONE TEMP LIGHTS. ALL LIGHTS WOULD EXTINGUISH WITH MASTER CAUTION RESET, BUT COULD NOT CONTROL THE CABIN TEMP. ACFT GROUNDED. ACCOMPLISHED BITE OF BOTH PZTC IAW IAW FIM 2SDR ASAA2016120718966Warning Light · false activationZONE TEMP LIGHT ILLUMINATED DURING RECALL. ACFT GROUNDED. PERFORMED PACK ZONE TEMP CONTROLLER BITE RESET IAW AMM 21-61-00-700-805-002, NO FAULTS.SDR ASAA2016120518939Control Valve · failedON RECALL CONTROL CABIN LIGHT ILLUMINATED. EXTINGUISHED ON RESET. ACFT GROUNDED. REMOVED AND REPLACED FLIGHT DECK TRIM AIR MODULATING VALVE IAW AMM 21-61-21. PERFORMED BITE CHECK IAW AMM TASK 21-61-00, ALL GREEN, TEST PASSED. NO LEAKS NOTED.SDR ASAA2016120418926Filter · cloggedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL, EXTINGUISHES ON MASTER CAUTION RESET. ACFT GROUNDED. REMOVED AND REPLACED A CLOGGED FILTER AND CLEANED TEMP SENSOR. ACCOMPLISHED PACK TEMP CONTROL BITE IAW FIM 21-62 TASK 801, FAULTED FLT DECK TRIM VALVE O
Back to JASC 2160