JASC 2160
Service difficulty reports · 3,041
Reports filed under 2160 · Cabin Temperature Control System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2015121314229Warning Light · false activationAFTER PUSHBACK AND ENGINE START CONT CAB ZONE TEMP AMBER LIGHT ILLUMINATED ON RECALL CHECK. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONTROLLER BITE CK. ALL PASS GO IAW AMM 21-51-00.SDR ASAA2015121314228Warning Light · false activationZONE TEMP LIGHT ILLUMINATES ON RECALL BUT RESETS. ACFT GROUNDED. BITE OF NR 2 PACK/ZONE TEMP CONTROLLER LOGGED FAULT: FLT DECK TRIM VALVE, RESETS. FLT DECK TRIM VALVE OPS NORMAL. NO ZONE TEMP LIGHT ON RECALL, REF FIM 21-62, TASK 848.SDR ASAA2015121214202Warning Light · false activationCONT CABIN ZONE TEMP LIGHT ILLUMINATED. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONTROLLER BITE CHECK IAW FIM 21-62 842. NO FAULTS FOUND. OPS CHECK GOOD.SDR ASAA2015121214197Controller · failedLEFT PACK LIGHT ILLUMINATED ON APPROACH ABOUT 3500' ON RECALL. ACFT GROUNDED. PERFORMED PACK/ZONE TEMPRATURE CONTROLLER BITE TEST. NO FAULTS OR FAULT HISTORY LOGGED. RAN LT PACK. PACK OPERATES NORMALLY. DUE TO HISTORY, R & R NR 1 PACK/ZONE TEMPERATURE CONSDR ASAA2015121114196Warning Light · false activationFWD CABIN-ZONE TEMP AMBER LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. NR 2 ZONE TEMP CONTROLLER LOGGED TRIM VALVE ZONE TEMP. RESET FAULT, PERFORMED BITE CHECK, OPS TEST NORMAL AMM 21-61-00.SDR ASAA2015121014200Warning Light · false activationON MASTER CAUTION RECALL, HAD LT CABIN ZONE TEMP LIGHT. LIGHT EXTINGUISHED WHEN MASTER CAUTION RESET. ACFT GROUNDED. BITE CHECK ZONE TEMP CONTROLLERS, NO FAULTS.SDR ASAA2015120914170Valve · failedDURING LANDING CHECK MASTER CAUTION RECALL, ZONE TEMP CONT CAB LIGHT ILLUMINATED. GOES OUT WHEN MASTER CAUTION IS RESET. ACFT GROUNDED. PERFROMED PACK/ZONE TEMP CONTROLLER BITE IAW FIM 21-62-00-810-801. NR 2 CONTROLLER SHOWS FLIGHT DECK TRIM VALVE FAULT ON SDR ASAA2015120914169Warning Light · false activationON RECALL CONTROLLER CABIN ZONE TEMP ILLUMINATES, EXTINGUISHES ON RECALL. ACFT GROUNDED. ON ZONE TEMP CONTOLLER 2, BIT, SHOWED, TRIM VALVE, FLT DECK, PREV FLGHT, SHOWED, TRIM VALVE, ZONE TEMP CONTROLLER 1 BIT SHOWED, GO, PREVIOUS FLIGHT SHOWED GO AND BOTH ZSDR ASAA2015120914168Warning Light · false activationDURING AFTER START CHECKLIST, MASTER RECALL "CONTROLLER CABIN" ZONE TEMP LIGHT ILLUMINATED. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE TEST, NO FAULTS NOTED. SYS TEST NORMAL, REF AMM 21-61-00.SDR VNAA2015120800007Sensor · dirtyCREW REPORTED RT PACK INOPERATIVE IN MANUAL MODE. CREW RETURNED TO FIELD AND LANDED WITHOUT INCIDENT. MAINTENANCE TROUBLESHOT, CLEANED CABIN TEMPERATURE SENSORS AND PERFORMED CHECKS IAW AMM. ACFT RELEASED FOR SERVICE.SDR 9JLA201512108841Modulating Valve · defectiveTHE FLIGHT CREW HAD SEVERAL REPORTS OF AN INTERMITTENT ISSUE CONTROLLING THE COCKPIT TEMPERATURE. THEY DESCRIBED THIS ISSUE, SAYING THE COCKPIT TEMP WOULD GET EXTREMELY HOT. THERE WERE ATTEMPTS TO CORRECT THE PROBLEM AFTER EACH REPORT WITH TECH SUPPORT ASSISSDR ASAA2015120714141Warning Light · false activationDURING MASTER CAUTION CHECK CONTROLLER CAB ZONE TEMP LIGHT ILLUMINATED. EXTINGUISHES ON MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED FIM 21-61, TASK 861, CONTROL CABIN AUTO TEMPERATURE CONTROL DOES NOT OPERATE FAULT ISOLATION. NO CURRENT FAULTS, GROUNDSDR ASAA2015120614130Controller · faultedCONTROL CABIN ZONE TEMP. LIGHT COMES ON DURING RECALL AND RESETS AFTER MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE, REF FIM 21-62, TASK 801. FOUND FAULT ON FLIGHT DECK TRIM VALVE NR 2 CONTROLLER. FAULT RESET, INTERMITTSDR ASAA2015120314097Controller · failedLEFT PACK LIGHT ILLUMINATES ON RECALL. PACK LIGHT GOES OUT ON MASTER CAUTION RESET. ACFT GROUNDED. NO FAULTS LOGGED AT THIS TIME. DUE TO PREVIOUS PACK HISTORY AND CONTROLLER FAULT LOGGED PREVIOUSLY, REPLACED NR 1 PACK/ZONE TEMP CONTROLLER REF AMM 21-61-20. SDR E07A20151207001Modulating Valve · stuckAFTER TAKEOFF, CREW NOTED HOT SMELL & A SMALL BIT OF SMOKE IN THE CABIN. TURNED OFF RT BLEED VLV, SMOKE & HOT SMELL DISSIPATED. DETERMINED RT CABIN TEMP MODULATING VLV WAS STUCK OPEN. INSTALLED NEW VLV, GND RUN & OPERATIONS CHECK WERE SATISFACTORY. ACFT WASDR ASAA2015120214078Modulating Valve · failedCONTROLLER CABIN ZONE TEMP LIGHT ON RECALL. ACFT GROUNDED. R & R FLT DECK TRIM MODULATING VALVE IAW AMM 21-61-21-400-801. LEAK CHECK GOOD IAW SAME REF ZONE TEMP FAULT NO LONGER ON RECALL.SDR ASAA2015120214077Sensor · dirtyAIR TEMP SUPPLY DUCT SWITCH DOES NOT READ CORRECTLY WHEN SWITCH IS IN AFT POSITION. TEMP GAGE VARIES BETWEEN 20-40 DEGREES C. ACFT GROUNDED. REPLACED FILTER AND CLEANED TEMP SENSOR, ACCOMPLISH BITE ON BOTH ZONE TEMP CONTROLLERS NO FAULTS REF AMM 21-61-00.SDR IPXA2015120296321Valve · inoperativeINSPECTION TYPE: FWD CABIN TEMP EICAS MESSAGE AND INOPERATIVE LIGHT. R & R TRIM AIR VALVE, V2 IAW AMM 21-61-07-40. OPS CK NORMAL,SDR ASAA2015112713955Indicator · inoperativeFORWARD PASSENGER CABIN AIR TEMPERATURE INDICATOR INOPERATIVE. IT READS 0 DEGREES C. ALL OTHER TEMPERATURE INDICATORS NORMAL. ACFT GROUNDED. ON DEFERRAL.SDR ASAA2015112513954Controller · false indicationCONTROL CABIN ZONE TEMP ILLUMINATED ON RECALL OF MASTER CAUTION, LIGHT EXTINGUISHED ON MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED BITE TEST NR 1 CONTROLLER, FLT DECK TRIM AIR AT FAULT. FAULT RESET, VERIFY TEST GOOD.SDR ASAA2015112113899Control Valve · failedAFTER PUSH AND ENGINE START, AFT CAB TEMP RAN AWAY HIGH. ON MASTER CAUTION RECALL, AFT ZONE TEMP LIGHT ILLUMINATED. TRIM AIR NEEDED TO BE TURNED OFF TO CONTROL AFT ZONE TEMP. ACFT GROUNDED. BITE CHECKED ZONE TEMP CONTROLLERS REF FIM 21-62, TASK 801, NR 1 CSDR ASAA2015111913898Controller · malfunctioned"CONTROLLER CABIN" ZONE TEMP LIGHT ILLUMINATES ON RECALL AND EXTINGUISHES WITH MASTER CAUTION. ACFT GROUNDED. BITE TEST NR 2 CONTROLLER SHOWED FLT DECK TRIM VALVE FAULT. VERIFY TEST IS GOOD. BITE CHECK NOW GOOD.SDR ASAA2015111913896Controller · malfunctionedCONTROLLER CABIN ZONE TEMP LIGHT ON WITH RECALL. RESETS WITH MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED CABIN TEMP CONTROLLER BITE REF 21-61, TASK 801. NO FAULTS. OPS TEST NORMAL.SDR ASAA2015111713823Control Valve · failedOBSERVED CONTROLLER CABIN ZONE TEMP LIGHT ON RECALL, EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED PACK TEMP CONTROL BITE CK, NR 1 & NR 2 PACK/ZONE TEMP CONTROLLER FAULTED, FLT DECK TRIM AIR VALVE, REF FIM 21-62, TASK 801. R & R FLT DECSDR ASAA2015111613797Warning Light · false activationAIR CONDITION AND MASTER CAUTION LIGHTS ILLUMINATED ON RECALL AFTER ENGINE START, WITH CONTROLLER CABIN ZONE TEMP LIGHT. BOTH LIGHTS WENT OUT WHEN MASTER CAUTION WAS RESET. ACFT GROUNDED. NR 2 PACK/ZONE TEMP CONTROLLER LOGGED FLT DECK TRIM VALVE FAULT. PERFSDR ASAA2015111513780Warning Light · false activationUPON "RECALL" ON THE AFTER START CHECK LIST, CONTROL CABIN ZONE TEMP LIGHT ILLUMINATES. LIGHT RESET UPON MC PUSH TO RESET. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE TEST, CONTROLLER NR 1 NO FAULTS, CONTROLLER NR 2 FAULTED TRIM VALVE FLT DECSDR ASAA2015111513783Control Valve · failedON MASTER CAUTION RECALL, ZONE TEMP CONT CAB ILLUMINATED AND EXTINGUISHED ON RESET. ACFT GROUNDED. ACCOMPLISHED PACK TEMP CONTROL BITE, FLT DECK TRIM VALVE LIGHT ILLUMINATED ON NR 2 PACK, ZONE TEMP CONTROLLER, REF FIM 21-62, TASK 801. R & R CONTROL CABIN TRISDR ASAA2015111513782Control Valve · failedAFTER ENGINE START AND DURING AND AFTER START CHECKLIST MASTER CAUTION RESET, CONT CAB "ZONE TEMP" LIGHT ILLUMINATED. THE "ZONE TEMP" LIGHT EXTINGUISHED UPON MASTER CAUTION RESET. ACFT GROUNDED. HAD "TRIM VALVE FLT DECK" FAULT. R & R V143, TRIM VALVE FOR CONSDR ASAA2015111113730Valve · failedFWD CAB & AFT CAB TEMP CONTROLLERS FAIL TO CONTROL CABIN TEMP IN AUTO. ROWS 6-12 WERE COLD WHILE AFT CABIN WAS TOO WARM. AS FWD CAB WAS TURNED WARMER, THE FLT CABIN ALSO GOT WARMER. RUNNING CONTROLLERS IN OFF STABILIZED THE TEMP. ACFT GROUNDED. ACCOMPLISHEDSDR ASAA2015111013710Filter · dirtyF/A'S REPORT CABIN TEMP EXCESSIVELY WARM DESPITE ATTEMPS TO COOL IN AUTO. MOVED ALL 3 CABIN TEMP CONTROLLERS TO OFF, APPEARED TO RESOLVE CABIN TEMP BUT FLIGHT DECK BECAME QUITE WARM. ACFT GROUNDED. BITE TEST OF BOTH TEMP CONTROLLERS REF AMM FIM 21-61, TASK SDR ASAA2015110913709Control Valve · failedLEFT PACK LIGHT ON MASTER CAUTION RECALL. ACFT GROUNDED. ZONE TEMP CONTROLLER BITE SHOWED AFT ZONE TEMP CONTROL VALVE HARD FAULT. R & R AND TESTED AFT ZONE TEMP CONTROL VALVE, V145 IAW MM 21-62-01, TEST PASSED.SDR ASAA2015110713665Control Valve · failedZONE TEMP CONTROLLER CAB LT ILLUMINATED ON RECALL, ACFT GROUNDED. R & R FLT DECK ZONE TRIM VALVE IAW AMM 21-61-21, OPS & LEAK CK NORMAL. NO FAULTS ON EITHER PACK/ZONE TEMP CONTROLLER AFTER BITE AND COCKPIT ZONE TEMP CONTROLLER CAB ANNUNCIATION REMAINS EXTINSDR ASAA2015110713666Controller · failedUPON RECALL RT PACK LIGHT ILLUMINATED ALONG WITH CONTROLLER CAB AND FWD CAB ZONE TEMP LIGHTS. QRH ACCOMPLISHED. PACK LIGHT & ZONE TEMP WOULD NOT EXTINGUISH. ACFT GROUNDED. FOUND NR 2 ZONE TEMP CONT FAILED, NO TEST, NO LIGHTS. CYCLED C/B'S - NO HELP. REPLACESDR ASAA2015110613660Warning Light · false activationCONTROLLER CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL, EXTINGUISHED WITH RESET. ACFT GROUNDED. ACCOMPLISHED NR 2 PZTC BITE REF 21-61-00. FOUND FAULT FLT DECK TRIM VALVE ONE TIME. PERFORMED FIM 21-61, TASK 861. FAULTS CLEARED GROUND RAN AC SYS FOR 1 HOUR.SDR ASAA2015110513664Control Valve · failedCONTROLLER CABIN PRIMARY TEMP CONTROL INOPERATIVE. ACFT GROUNDED. CONFIRMED FAULT, RT ZONE TEMP CONTROLLER SHOWS FLIGHT DECK TRIM VALVE, V143, FAULTS. R & R FLIGHT DECK TCV REF AMM TASK 21-61-21, GROUND FUNCTIONAL CK/LEAK CK AND PACK/ ZONE TEMP CONTROLLER BSDR ASAA2015110513663Control Valve · failedMID CABIN REPORTED EXCESSIVELY HOT. FWD AND AFT CAB CONTROLLERS SET TO COLD. FWD AND AFT CABIN COLD, MID CABIN STILL HOT IAW QRH 2.7 TURNED OFF TRIM AIR. TEMP NOW CONTROLLABLE THROUGH OUT. ACFT GROUNDED. COULD NOT DUPLICATE FAULT. PERFORMED ZONE TEMP CONSDR ASAA2015110513657Control Valve · failedRIGHT PACK LIGHT COMES ON AT MASTER CAUTION RECALL. ACFT GROUNDED. PERFORMED PACK TEMP CONT BITE IAW FIM 21-62, TASK 801. RT PACK LOGGED TCV FAULT. R & R RT PACK TCV REF. AMM 21-51-10. LEAK CK GOOD. PERFORMED RT PACK TEMP CONTROL BITE TEST IAW AMM 21-61-SDR ASAA2015110413643Control Valve · failedFORWARD CABIN TEMPERATURE VERY WARM, ESTIMATE 90 DEGREES WITH TEMPERATURE SELECTOR IN FULL COLD POSITION. COMPLIED WITH QRH PROCEDURE AND SELECTED TRIM AIR OFF. TEMPERATURE IN CABIN RETURNED TO NORMAL. ACFT GROUNDED. COULD NOT DUPLICATE MALFUNCTION. PZTC LSDR ASAA2015110413639Warning Light · false activationUPON RECALL, AIR CONDITIONER & CONTROLLER CAB ZONE TEMP LIGHT ILLUMINATED, LIGHT EXTINGUISH ON RESET. ACFT GROUNDED. PERFORMED A PACK/ZONE CONTROLLER BITE TEST REF AMM 21-51-00. NO FAULTS FOUND.SDR ASAA2015110213602Control Valve · failedAFTER PUSHBACK AND START UP ON MASTER RECALL, WE HAD ZONE TEMP LIGHT UP ON THE OVERHEAD CONTROLLER CAB, IT EXTINGUISHED WITH THE RESET. ACFT GROUNDED. CONFIRMED FAULT, NR 2 PACK ZONE TEMP CONTROLLER SHOWS FLT DECK TCV, V143, FAULT. NR 1 PACK ZONE TEMP CONTROSDR ASAA2015102713537Control Valve · failedLEFT PACK LT ILLUMINATED ON RECALL. EXTINGUISHED WITH MASTER CAUTION RESET. ACFT CHECKED AND RELEASED IAW MEL 21-32B, LT PACK TEMP CONTROL INOPERATIVE. ACFT GROUNDED. R & R LT TEMP CONTROL VALVE. OPS CHECKS NORMAL.SDR ASAA2015102313514Filter · cloggedUNABLE TO CONTROL CABIN TEMPRATURE PROPERLY. FWD AND AFT CAB KNOBS IN FULL COLD DRIVE SUPPLY DUCTS TO 10 DEG, IF MOVE THEM TO 12 O`CLOCK POSITION, SUPPLY DUCTS STAY AT 10 DEG C, MUST MOVE THEM TO 1 O`CLOCK POSITION FOR TEMP TO INCREASE. IN "FIXED CABIN TEMP SDR ASAA2015102013479Warning Message · false activationZONE TEMP, CONT CABIN, ON RECALL. ACFT GROUNDED. NR 2 TEMP CONTROLLER SHOWED FLIGHT DECK TCV FAULT LOGGED. RAN BITE OF CONTROLLER, REF 21-61-20. FAULT CLEARED. NO PREVIOUS HISTORY.SDR ASAA2015101913441Warning Message · false activationCONTROL CABIN ZONE LIGHT ILLUMINATED, EXTINGUISHES ON RECALL. ACFT GROUNDED. ACCOMPLISHED BITE OF THE PACK/ZONE TEMP. CONTROLLERS, REF FIM 21-82, TASK 801 ON NR 2 CONTROLLER FLIGHT DECK TRIM VALVE, FAULT CLEARED. RAN APU & PACKS, FLIGHT DECK TEMP. WAS CONTRSDR ASAA2015101613513Warning Light · false activationON RECALL FWD CABIN ZONE TEMP LIGHT ON EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. RIGHT PACK ZONE CONTROLLER LOG FAULT. RESET FAULT, PERFORMED BITE CHECK. BITE CHECK NORMAL, REF AMM 21-61-00.SDR ASAA2015101513511Controller · malfunctionedTEMP CONTROL IN ALL 3 ZONES "HYPER-SENSITIVE", LARGER THAN USUAL SUPPLY DUCT TEMP CHANGES WITH SMALL ADJUSTMENTS. CONDITION MOST PRONOUNCED AFTER ENGINE START & TAKE OFF, THEN IMPROVED ENROUTE. WHEN TEMP SELECTORS OFF: ON GROUND SUPPLY DUST TEMP IN ALL 3 ZONSDR ASAA2015101513510Control Valve · warning lightFWD CABIN ZONE TEMP LIGHT ILLUMINATES ON RECALL, GOES OUT AFTER MASTER CAUTION RESET. ACFT GROUNDED. REF FIM 21-62T814, ACCOMPLISHED PIN TO PIN & PIN TO GROUND RING OUT, MEG CK OF WIRES FROM D15016 AT M2847 TO D3860A, REF WDM 21-61-13. ALSO, SHOOK DOWN ALLSDR ASAA2015101213476Warning Light · false activationDURING RECALL MASTER CAUTION AIR CONDITIONING LIGHT ILLUMINATES AND CONTROLLER CAB ZONE TEMP LIGHT ILLUMINATES. DURING RESET, LIGHTS EXTINGUISH. ACFT GROUNDED. FFR NR 2 TEMP CONTROLLER SHOWS FLT DECK TRIM VALVE FAULT ON PREVIOUS FLIGHT. NO HISTORY - 60 DAYSSDR ASAA2015101213475Warning Light · false activationFORWARD CAB ZONE TEMP ILLUMINATED ON RECALL. ACFT GROUNDED. PERFORMED RT TEMP CONTROLLER BITE AND FOUND ZONE FAULT LIGHT ON. ABLE TO CLEAR FAULT REF 21-61-00. OPS CHECKED SYS, NO FAULTS RETURNED.SDR ASAA2015101013414Warning Message · false activationCONTROL CABIN ON RECALL. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONTROL BITE TEST. FOUND NO FAULTS LOGGED. RAN PACK FOR 1 HR, BITE TESTED 2ND TIME. CK GOOD. NO FAULTS, IAW MM 21-61-00.
Back to JASC 2160