SDR ASAA2014021206834Warning Message · unknownAFT CABIN ZONE TEMP ILLUMINATES ON RECALL. ACFT GROUNDED. PERFORMED PACK-ZONE TEMP CONTROLLER BITE PROCEDURE. FOUND STANDBY PACK FAULT LIGHT ILLUMINATED DURING THE BITE PROCEDURE ON THE NR 2 PACK - ZONE TEMP CONTROLLER. FAULT NOT PRESENT DURING THE VERIFY SDR ASAA2014020906809Valve · faultedCONT CAB ZONE TEMP LIGHT ILLUMINATED ON RECALL. EXTINGUISHES ON RESET. ACFT GROUNDED. PERFORMED PAC/ZONE TEMP CONT BITE IAW MM 21-61-00, PREVIOUS FLT SHOWED RT PACK, COCKPIT TRIM VALVE FAULT. VERIFY SHOWED PASS. NO HISTORY 90 DAYS.SDR ASAA2014020906806Valve · faultedWHILE PERFORMING BITE CHECK ON NR 1 ZONE TEMP CONTROLLER, FOUND AFT CABIN ZONE TEMP VALVE FAULTED. ACFT GROUNDED. REPLACED AFT CABIN ZONE TEMP VALVE, REF MM 21-61-21, OPS CHECK BITE CHECK GOOD. OK FOR SERVICE.SDR ASAA2014020606787Control Valve · malfunctionedON RECALL, CONTROLLER, CABIN ZONE TEMP LT ILLUMINATED, IAW QRH. LIGHT EXTINGUISHED WHEN MASTER CAUTION SYSTEM IS RESET. ACFT GROUNDED. REF FIM 21-62 TASK 832 AND PACK/ ZONE W TEMP CONTROLLER BITE REF FIM 21-62, TASK 801. ACCOMPLISH TEMP CONTROLLER BITE. CONTSDR ASAA2014020306762Control Valve · faultedBITE OF LT PACK- ZONE TEMP CONTROLLER SHOWS FAULT FOR AFT ZONE TEMP CONTROL VALVE TRIM AIR VALVE. VERIFY TEST CONFIRMS FAULT. ACFT GROUNDED. R & R AND TESTED V145 AFT CABIN TRIM AIR VALVE IAW MM 21-61-21-000-801/MM 21-61-21-400-801. OPS NORMAL, NO LEAKS NOSDR ASAA2014020206754Warning Light · illuminatedON MASTER CAUTION RECALL, AFTER ENGINE START, THE AIR COND ANNUNCIATOR AND THE CONT CAB ZONE TEMP LIGHTS ILLUMINATED. BOTH LIGHTS EXTINGUISH WHEN THE MASTER CAUTION SYSTEM IS RESET. ACFT GROUNDED.SDR ASAA2014013106727Warning Light · false activationCONT CAB ZONE TEMP LIGHT ILLUMINATED DURING RECALL. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE TEST ON CONTROLLERS 1 & 2. NO ERRORS. GROUND VERIFICATION SUCCESSFUL IAW AMM 21-61-00-700-806-002.SDR ASAA2014012612495Filter · dirtyF/A REPORTED PASSENGERS COMPLAINED OF AIR CONDITIONING ERRATIC HOT & COLD. NO DISCREPANCIES NOTED WITH CONTROL OF AIR CONDITIONING IN COCKPIT NOR WITH TEMPERATURE READINGS. ACFT GROUNDED. CLEANED CABIN TEMPERATURE SENSORS ASSY FILTER IAW MM 21-61-06-100-801.SDR ASAA2014012612494Warning Message · false activationCONTROL CABIN AMBER ZONE TEMP, ANNUNCIATOR ILLUMINATES WHEN MASTER CAUTION PUSHED. LIGHT RESETS WITH MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMPERATURE CONTROLLER BITE PROCEDURE NR 2 SHOWS FAULT FOR VALVE (V143) & NR 1 SHOWS NO FAULTS. SDR ASAA2014012612493Warning Message · false activationDURING RECALL, CABIN ZONE TEMP LIGHT ILLUMINATED. DURING RESET, MASTER CAUTION LIGHT EXTINGUISHED. ACFT GROUNDED. PERFORMED A BITE TEST OF TEMPERATURE CONTROLLER IAW AMM 21-61-00-700-806-002. NO FAULTS NOTED.SDR ASAA2014012412470Warning Message · false activationDURING RECALL, MASTER CAUTION FOR AIR CONDITIONING AND CONTROL CABIN ZONE TEMP LIGHTS REMAINED ILLUMINATED AND EXTINGUISHED ON MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED FIM 21-62, TASK 832 & FLT DECK TRIM FAULT ON NR 2 TEMP CONTINUE CLEARED, GROUND FUNCSDR ASAA2014012312469Warning Message · false activationCABIN LIGHT ILLUMINATES, ZONE TEMP ON RECALL. EXTINGUISHED WHEN RESET. ACFT GROUNDED. BITE SHOWS FLT DECK TRIM VALVE FAULT ON NR 2 CONTROLLER. CLEARED FAULT AND BITE OF CONTROLLER, OPS NORMAL IAW AMM 21-61-00, TASK 801.SDR ASAA2014011912406Controller · faultedRECEIVED A ZONE TEMP LIGHT, RAN QRH PROCEDURES AND UPON RESETING MASTER CAUTION, LIGHT WENT OUT. ACFT GROUNDED. AUTO TEMP CONTROLLER LOGGED COCKPIT TRIM VALVE FAULT. RAN BOTH AUTO TEMP CONTROLLERS BITE TEST IAW FIM 21-62, TASK 842 AND FAULT CLEARED AND RESETSDR CA140120005Control Valve · mismanufacturedTEMP CONTROL VALVE, SN 0097 WAS INSTALLED TO RECTIFY ISSUE WITH ORIGINAL, SN 1691. WHILE PERFORMING GROUND RUNS AND TESTS, THE TEMP CONTROL SYSTEM SEEMED TO BE IN FULL HOT MODE. THE DUCT OVER-TEMP PROTECTION SWITCH SHUT THE SYS DOWN AND DISPLAYED A CAS MESSSDR ASAA2014011412392Warning Light · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL DURING LANDING CHECK. ACFT GROUNDED. PERFORMED FIM 21-62-842. TESTS OK. CABIN ZONE TEMP LIGHT STAYS OUT. NO HISTORY 90 DAYS. GROUND VERIFICATION TESTS OK.SDR CA140113004Control Valve · failed(CAN) DURING PRE-FLIGHT INSPECTION, WHILE IN THE HANGAR, AFTER ENERGIZING ACFT ELECTRICAL SYSTEM, TEMPERATURE CONTROL VALVE COULD BE HEARD OPERATING. FURTHER INVESTIGATION REVEALED THAT THE VALVE WAS NOT PHYSICALLY MOVING, WHILE THE ACTUATOR MOTOR WAS CONTINUSDR ASAA2014010812346Warning Light · false activationCONT CABIN ZONE TEMP LIGHT ILLUMINATES ON RECALL. RESETS WHEN RESETTING MASTER CAUTION. ACFT GROUNDED. PERFORMED ZONE TEMP CONTROLLER BITE TEST IAW AMM 21-61-00 - FOUND NR 2 ZONE TEMP UNIT W/ FLT DECK CABIN SENSOR RED FAULT LIGHT ON IN PREVIOUS FLT MODE. VSDR ASAA2014010712339Warning Light · false activationCONT CABIN ZONE TEMP LIGHT ON. LIGHT GOES OUT WHEN MASTER CAUTION IS RESET. ACFT GROUNDED. PERFORMED FIM TASK 21-62, TASK 832, SYSTEM BITES NORMAL. RAN LT PACK, NO FAULTS NOTED. GROUND VERIFICATION SUCCESSFUL.SDR ASAA2013122812245Valve · failedCONT CABINE ZONE TEMP LIGHT ILLUMINATED ON MASTER CAUTION RECALL. ACFT GROUNDED. RT TEMP CONTROLLER LOGGED FLIGHT DECK TRIM VALVE, V143. PERFORMED FIM 21-62, TASK 832. REQUIRES VALVE CHANGE. LT TEMP CONTROLLER LOGGED LT TCV, V139. PERFORMED FIM 21-62, TASSDR YENA20131228252Circuit Card · failedAIRCRAFT DIVERTED, FLIGHT DECK TEMP UNCONTROLLABLE, COCKPIT TEMP 3C CABIN TEMP 17C. R & R AMS CONT CARD SPDA 2 SLOT REF AMM 21-00-03. OPS CK GOOD.SDR ASAA2013122312223Valve · failedDURING CRUISE FLIGHT, AT FL 340, CONTROL CABIN AUTO TEMP CONTROL DELIVERS NO HIGHER THAN 19 DEGEES IN THE MAN/OFF POSITION THE SYS DELIVERS 23 DEGREES CONSEQUENTLY, THE PF AND THE PNF ARE NOT HAPPY BECAUSE THE ARE COLD AND DISTRACTED. PASSENGER CABIN CONTROLSSDR CALA2013122393885Valve · faultyCOND HOT AIR FAULT. ACFT IS FAULTING TRIM AIR VLV. REPLACE TRIM AIR VLV IAW AMM 21-63-52 FOR R &R OF VLV. VLV PCN IS 644-0100. R & R TRIM AIR VLV IAW AMM, OPERATIONS CHECKED GOOD. MEL CLEARED PLA REMOVED.SDR ASAA2013122112187Warning Light · false activationCONT CABIN ZONE, TEMP LIGHT ILLUMINATED ON RECALL BUT RESETS SYSTEM APPEARS TO OPERATE NORMALLY. ACFT GROUNDED. PERFORMED FIM 21-62/832. NO FAULTS FOUND. INTERMITTENT FAULT. NO HISTORY 60 DAYS.SDR ASAA2013122112191Modulating Valve · faultedFLT DECK TOO COLD, CANNOT MAKE WARMER IN AUTO MODE. OK IN MANUAL MODE. ACFT GROUNDED. PERFORMED BITE TEST OF PACK/ZONE TEMP CONTROLLERS IAW MM 21-51-00-700-803. THE CONTROLLER FAULTED THE CONTROL CABIN TRIM VALVE. REPLACED TRIM AIR MODULATING VALVE FOR THESDR ASAA2013122012185Filter · dirtyCABIN TEMP CONTROL WORKS ERRATICALLY. COCKPIT TEMP IS STILL TOO COOL EVEN WITH TEMP CONTROL FULL HOT. ACFT GROUNDED. FOUND TEMP SENSOR FILTER VERY DIRTY. CLEANED ALL TEMP SENSOR FILTERS REF MM 21-61-06. TESTS OK. SUCCESSFUL GROUND VERIFICATION COMPLETED.SDR ASAA2013122012184Sensor · failedCONTROL CABIN TEMP CONTROL INOPERATIVE. COCKPIT TEMP VERY COLD REGARDLESS OF WHERE CONTROL IS POSITIONED. ONLY WAY TO KEEP IT WARM IS TO TURN TRIM AIR OFF AND CONTROLL CAB OFF. ACFT GROUNDED. FOUND CONTROLL CABIN SENSOR FAULT ON BOTH PACK/ZONE TEMP CONTROLSDR ASAA2013121912188Unknown · unknownCABIN TEMP SELECTOR TURNED UP TO MAX AND COCKPIT IS STILL COOLER THAN DESIRED. TRIM AIR OFF RESTORED CABIN HEAT. ACFT GROUNDED. BITE CKD BOTH TEMP CONTROLLERS FIM 21-61, TASK 801 NO FAULTS LOGGED. GVI LT PACK FOR LEAKS, NO LEAKS NOTED. OPS CKD FLT DECK TEMP SDR ASAA2013121712161Control Valve · failedLEFT PACK LIGHT ILLUMINATED DURING RECALL, PACK LIGHT EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. R & R LT TEMP CONTROL VALVE IN REF AMM 21-51-10. PERFORMED OPS CK IAW MM 21-51-10-400, PASSED.SDR CALA2013121693728Actuator · faultyPACK 2 HIGH TEMP OUTPUT OF 95C CAUSING CABIN TEMPS OF 85F+. PACK OFF IAW A320 QRH 20.23. IAW MEL 2152B RT PACK INOPERATIVE VLV FOLLOW COMMAND. HITTING PACK 2 RAM AIR INLET ACTUATOR. IAW TSM TASK 21-61-00-810-850-A. ACTUATOR WAS REPLACED 5DEC FOR OSCILLATSDR ASAA2013121196831Warning Light · illuminatedZONE TEMP ON CONTROLL CAB ON DURING RECALL, CANCELS ON RESET. ACFT GROUNDED. CONFIRMED CONTROL CABIN ZONE TEMP ANNUNCIATES, ILLUMINATES W/ MASTER RECALL. PERFORMED PACK/ZONE TEMP CONTROLLER BITE TEST IAW AMM 21-61-00, FOUND NR 2 CONTROLLER W/ BIT & PREVIOUS FSDR ASAA2013120796661Controller · malfunctionedZONE TEMP FWD CABIN LIGHT ON RECALL, WOULD NOT RESET IAW QRH. ACFT GROUNDED. PERFORMED BITE TEST ON BOTH TEMP CONTROLLERS, ZONE TEMP CONTROLLER NR 1 SHOWED CONTROLLER FAULT STANDBY PACK RESET CONTROLLER FAULT CLEARED, RETESTED CONTROLLER, NO FAULTS NOTED.SDR ASAA2013120796655Sensor · dirtyLEFT PACK LIGHT ILLUMINATED ON RECALL. LIGHT EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. BITE CHECK OF NR 1 AND 2 ZONE TEMP CONTROLLERS SHOWS NO FAULTS. CLEANED COCKPIT TEMP SENSOR. RAN BITE ON BOTH ZONE TEMP CONTROLLERS. ALL OPS NORMAL. NO SDR CALA2013120393418Control Valve · faultyTEMPERATURE ON FWD CABIN CONTROLLER VARIES A LOT & CANNOT CONTROL TEMPERATURE. TROUBLE SHOT TO FWD CABIN TRIM AIR VLV 12HK, IAW AMM 21-63-51 PCN 644-0088. R & R VLV AIR FLOW CONTROL 12 HK IAW AMM, OPERATIONS CHECKED OKAY.SDR CALA2013120393417Unknown · malfunctionedTRIM AIR SYS FAULT. TRIM AIR HI PRESS ECAM AT START OF TAKEOFF ROLL & 1 MIN INTO FLIGHT. RT AFT SWELTERING HOT, FWD FREEZING.SDR ASAA2013112896571Valve · malfunctionedZONE TEMP AMBER LIGHT FOR CONTROL CAB ILLUMINATES ON RECALL. EXTINGUISHES ON RESET. ACFT GROUNDED. NR 2 TEMP CONTROLLER LOGGED FLT DECK TRIM AIR VALVE. SYS TESTS GOOD, FAULT RESET.SDR ASAA2013112796555Valve · faultedON RECALL MAST CAUTION , AIR CONDITIONING, AND CONT CABIN ZONE TEMP LIGHT ILLUMINATED. ON MAST CAUTION RESET, ALL LIGHTS EXT. TEMPERATURE CONTROL IS NORMAL. ACFT GROUNDED. NR 2 ZONE TEMP CONTROLLER SHOWS A FLT DECK TRIM VALVE ON BITE & PREVIOUS FLT. REPLASDR ASAA2013112696548Warning Light · illuminatedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL AND WILL NOT RESET WITH TRIP RESET. AIRCRAFT GROUNDED. CONFIRMED CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL. PERFORMED PACK/ZONE CONTROL BITE TEST IAW AMM 21-61-00. FOUND NR 2 PACK/ZONE TEMP CONTROSDR ASAA2013112696547Filter · dirtyUNABLE TO CONTROL FLT DECK TEMP USING CONTROL CABIN TEMP SELECT. ACFT GROUNDED. CLEANED CONTROL CABIN TEMP SENSOR & REPLACED FILTER. OPERATED PACKS. VERIFIED CONTROL CABIN DUCT TEMP, RESPONDS TO TEMP SELECTOR NORMALLY. BITE CHECK OF BOTH TEMP CONTROLLERS SDR ASAA2013112596546Warning Light · illuminatedAMBER ZONE TEMP LIGHT ILLUMINATED AFTER START. FOLLOWED QRH, LIGHT EXTINGUISHED. LIGHT CAME BACK ON AT RECALL ON LANDING. AIRCRAFT GROUNDED. PERFORMED BITE CHECK OF PACK/ZONE TEMP CONTROLLERS 1 & 2 REF AMM 21-61-00. FLT DECK TRIM VALVE DISPLAYED ON NR 2 RESDR SIMA20131124006Fan · faultyDISPLAY FAN MADE LOUD NOISE WITH ELEC BURNING SMELL. DISPLAY FAN INOPERATIVE IN NORMAL POSITION WITH DISPLAY COOL ON ED1. DEFERRED ITEM IAW MEL 21-05. REMOVED AND REPLACED DISPLAY COLL FAN AIW 21-24-12 (AMM). OPS CHECK OK. MEL RESTOREDSDR ASAA2013111796443Warning Light · false activationCONT CABINE ZONE TEMP CAUTION LIGHT ILLUMINATED ON RECALL WITH NO RESET. ACFT GROUNDED. FAULT RESETS WITH MASTER CAUTION RESET. CLEARED NR 2 CONT CABIN TEMP VALVE FAULT. ACCOMPLISHED BITE TEST OF PACK/TEMP CONTROLLERS IAW AMM 21-61-00. NO FAULTS NOTED.SDR ASAA2013111596422Warning Light · illuminatedON RECALL ZONE TEMP CONT. CABIN LIGHT COMES ON. RESET THE MASTER CAUTION AND THE LIGHT GOES OUT. ACFT GROUNDED. NR 2 ZONE CONT LOGGED FLT DECK TRIM VALVE, FAULT CLEARED & TESTED NORMAL IAW 21-61-00.SDR WX0A2013111800755Controller · inoperativeAFTER TAKEOFF ON CLIMBOUT RT PACK WENT FULL HOT WITH SMELL OF SMOKE. ALL 3 SMOKE DETECTORS ACTIVATED. QRH 26.9 AND FOLLOWED PROCEDURE. ALSO PERFORMED QRH 21.9 TEMPERATURE AUTO CONTROL FAILURE. SMELL AND SMOKE STOPPED AFTER RT PACK SHUTOFF. DIVERTED IAW MX CSDR ASAA2013111496418Controller · warning messageFWD CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL DURING APPROACH. ACFT GROUNDED. BITE CHECK NR 1 CONTROLLER STANDBY PACK LIGHT. REPLACED NR 1 CONTROLLER REF MM 21-61-01.SDR ASAA2013111396410Controller · malfunctionedAFTER ENGINE START, ON MASTER CAUTION RECALL, CONT CABIN ZONE TEMP ANNUNCIATOR ILLUMINATED. ACFT GROUNDED. RESET NR 2 ZONE TEMP CONTROLLER IAW MM 21-60-00 AND 21-62 TASK 801.SDR CA131112014Regulator Valve · malfunctioned(CAN) AT ALTITUDE WITH BLEED AIR ON, TEMP CONTROL KNOB TO FULL HOT. VERY LIMITED AMOUNT OF HEATED AIR ENTERING CABIN. OUTSIDE AIR 19C SURFACE TEMPERATURE ON GROUND AROUND -6C. AT CRUISE ITT 610C. CABIN HEAT DOES NOT START FLOWING TILL APPROXIMATELY 15-20 SSDR ASAA2013111096327Filter · dirtyCABIN AIR TEMPERATURE IS HARD TO CONTROL. AFT CABIN TEMPERATURE DEMANDS SEEM HIGHER THAN NORMAL TO MAINTAIN ADEQUATE WARMTH AND TO MAINTAIN SAME TEMPERATURE AS THE FORWARD CABIN. THE TEMP CONTROL KNOBS SEEM TO BE IN ABNORMALLY SPLIT POSITIONS TO MAINTAIN ADESDR CALA2013110892757Unknown · malfunctionedUNABLE TO COOL COCKPIT BELOW 86.SDR ASAA2013110396289Filter · dirtyTEMPERATURE WAS IMPOSSIBLE TO CONTROL. MANY COMPLAINTS BY F/AS AND PAX. ACFT GROUNDED. PERFORMED BITE CK ON BOTH TEMP CONT, BOTH CK OK ALL GOS. OPERATED BOTH PACKS, FOUND FWD & AFT CABIN TAKES MUCH LONGER TO GET TO TEMP & CONT CAB CK OK. FOUND BOTH CABIN TSDR AALA20131027007Control Valve · inoperativeDFW BOTH CABIN TEMPERATURE CONTROLS INOPERATIVE. FLIGHT RETURNED DFW LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED RT TEMPERATURE CONTROL VALVE. SYSTEM GROUND CHECKED NORMAL OPERATION CLOSED.
Back to JASC 2160