JASC 2160
Service difficulty reports · 3,041
Reports filed under 2160 · Cabin Temperature Control System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2160' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2014062808370Control Valve · faultedAFT CABIN ZONE TEMP LIGHT ILLUMINATED DURING RECALL. ACFT GROUNDED. PERFORMED CABIN TEMP CONTROL BIT CHECK ON NR 2 CONTROLLER. CURRENT FAULT SHOWS BACKUP ZONE, AFT ZONE, SENSOR. ON VERIFY GOT TCV FAULT ON NR 2. RESET NR 2 CONTROLLER. RAN BIT CHECK NO FAUSDR ASAA2014062808369Warning Message · false activationDURING WALK AROUND, FOUND "FLT DECK TRIM VALVE" LIGHT ILLUMINATED ON ZONE TEMP CONT NR 2. ACFT GROUNDED. ACCOMPLISH 21-62, TASK 801, CLEARED FAULT. PERFORMED TEST AGAIN, FAULT DID NOT COME BACK. NO FAULTS NOTED ON RECALL.SDR FDEA201406271569Valve · inoperativeRIGHT ON DESCENT HAD A FAINT HOT ELEC SMELL. ON LANDING WE WERE UNABLE TO CONTROL THE COCKPIT TEMPERATURE IN AUTO OR MANUAL MODE. R & R 3 WAY VLV & TESTED IAW AMM 21-27-70-4. DURING MTSI COMPLIANCE FOUND VLV AT LOCATOR V21021 PARTIALLY OPENED. R & R VLV IASDR ASAA2014062508351Sensor · dirtyAFTER STARTING THE ENGINES AFT CABIN ZONE TEMP LIGHT ILLUMINATED. DURING RECALL WHEN THE MASTER CAUTION WAS RESET, THE ZONE TEMP LIGHT EXTINGUISHED. QRH WAS ACCOMPLISHED AND MASTER CONTROL WAS NOTIFIED. ACFT GROUNDED. ZONE TEMP CONTROLLER 2 FAULTED BACKUPSDR ASAA2014062408341Warning Light · false activationAFT CABIN ZONE TEMP LIGHT ILLUMINATED DURING MASTER CAUTION RECALL DURING LANDING CHECK . EXTINGUISHES DURING MASTER CAUTION RESET. ACFT GROUNDED. BITE CHECKED BOTH ZONE TEMP CONTROLLERS IAW MM 21-61-00. FOUND NR 2 ZONE TEMP CONTROLLER FAULTED BACKUP CABIN SDR ASAA2014062408340Warning Light · false activationAFTER ENGINE START, ZONE TEMP LIGHT ON RECALL. ACCOMPLISH QRH 2.15 LIGHT EXTINGUISHED WHEN MASTER CAUTION RESET. TRIP RESET PUSHED BUT ZONE TEMP LIGHT DID NOT RESET ON TRIP RESET. ACFT GROUNDED. NR 2 PACK TEMP CONT LOGGED FLT DECK TRIM AIR FAULT LAST FAULTSDR ASAA2014061508201Sensor · dirtyCAB ZONE LIGHT ILLUMINATES ON RECALL AND EXTINGUISHES ON MASTER CAUTION RESET. ACFT GROUNDED. PACK/ZONE TEMP CONTROLLER BITE IAW FIM 21-61, TASK 801, SHOWED FLIGHT DECK TRIM VALVE FAULT ON NR 2 ZTC BUT VERIFY TEST PASSED WITH NO FAULTS. FOUND FLIGHT DECK TEMSDR ASAA2014061308173Display · malfunctionedNO SATCOM PROMPT ON MCDU. ACFT GROUNDED. ACCOMPLISHED FIM TASK 23-15, TASK 801, NO FAULTS NOTED. NO HISTORY 90 DAYS.SDR ASAA2014060708082Controller · failedRIGHT PACK LIGHT ILLUMINATED DURING RECALL. ACFT GROUNDED. PACK/ZONE CONTROLLER FAULT LOGGED. FAULT CLEARED & BITE CK WAS NORMAL SEVERAL TIMES. DURING NORMAL PACK OPERATION, FAULT WOULD OCCUR AFTER APPROX 15 MINUTES. REPLACED NR 2 PACK/ZONE TEMP CONTROLLERSDR ASAA2014052607929Selector Knob · malfunctionedAIR TEMP SELECTOR SWITCH GIVES ERRATIC INDICATIONS WITH COCKPIT SELECTED. OTHER POSITIONS NORMAL. KNOB IS VERY LOOSE. ACFT GROUNDED.SDR ASAA2014052207916Warning Light · false activationFLIGHT DECK ZONE TEMP LIGHT ILLUMINATES ON RECALL. ACFT GROUNDED. PERFORMED TASK 21-61-00-700-806-002 PACK/ZONE TEMP CONTROLLER BITE TEST. NO FAULTS FOUND AFTER RESET. NO HISTORY 60 DAYS.SDR ASAA2014051607826Modulating Valve · failedAFTER START, DURING RECALL THE AIR CONDITION LIGHT ILLUMINATED ASSOCIATED WITH ZONE TEMP LIGHT CONTROL CABIN. PERFORMED QRH. LIGHT EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. R & R CONTROL CABIN TRIM AIR MODULATING VALVE ASSY, OPS BITES GOOD IAW SDR ASAA2014051507825Controller · malfunctionedAMBER "ZONE TEMP" FOR CONTROL CABIN COMES ON WITH RECALL, EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. TESTED PACK/ZONE TEMP CONTROLLER IAW AMM 21-61-00-700-806-002. NO HARD FAULTS AND NO MAINTENANCE HISTORY WITHIN PAST 30 DAYS.SDR ASAA2014051407809Regulator · malfunctionedCOCKPIT CABIN TEMP CONTROLLER WOULD NOT PROVIDE WARM AIR IN FULL WARM POSITION. COCKPIT REMAINED VERY COLD THROUGHOUT FLIGHT. ACFT GROUNDED. ACCOMPLISHED BITE CHECK OF BOTH PACK/ZONE TEMP CONTROLLERS. BOTH PASS AIRFLOW ACROSS CONTROL CABIN TEMP SENSOR OK. SDR ASAA2014050907735Modulating Valve · malfunctionedDURING RECALL, ZONE TEMP ILLUMINATED FOR CONTROL CABIN. EXTINGISHED AT MASTER CAUTION RESET. ACFT GROUNDED. REPLACED CONTROL CABIN TRIM AIR MODULATING VALVE IAW AMM 21-61-21-000-801/-400-801. OPS AND LEAK CHECKED GOOD.SDR ASAA2014042707587Control Valve · malfunctionedCONT CAB "ZONE TEMP" LIGHT ILLUMINATES ON MASTER CAUTION RECALL AND EXTINGUISHES ON MASTER CAUTION RESET. ACFT GROUNDED. PERFORMED PACK/ZONE TEMPERATURE CONTROLLER BITE IAW FIM 21-62, TASK 801, FAULTED LT PACK TCV. REMOVED LT PACK TEMP CONTROL VALVE IAW MM SDR ASAA2014042507569Valve · malfunctionedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON MASTER CAUTION RECALL. LIGHT EXTINGUISHES ON RESET. ACFT GROUNDED. R & R TRIM AIR MODULE VALVE REPLACED IAW IAW 21-61-021-00MM. OPS CHECKED GOOD.SDR ASAA2014041707497Screen · cloggedON RECALL, AFT CABIN ZONE TEMP LIGHT ILLUMINATED. RAN CHECKLIST, LIGHT STAYED ON. ACFT GROUNDED. PERFORMED FIM 21-61, TASK 801 T/S. ALL BITE CHECKS ON ZONE TEMP CONTROLLER AND PASSED. FOUND AFT CABIN TEMP SENSOR INLET SCREEN CLOGGED, CLEANED SCREEN. RAN PASDR ASAA2014041707493Warning Message · false activationCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED DURING RECALL. ACFT GROUNDED. PERFORMED SUCCESSFUL ZONE TEMP CONTROLLER BITE TEST IAW AMM 21-61-00-700-806-002. NO HARD FAULTS FOUND AND NO MAINTENANCE HISTORY FOUND FOR THE PAST 30 DAYS.SDR ASAA2014041407472A/C Pack · malfunctionedCABIN TEMP CONTROLLER REQUIRED ABNORMALLY HIGH SETTING TO MAINTAIN A COMFORTABLE TEMPS. ALL THREE CONTROL KNOBS IN 2 O'CLOCK POSITION. ACFT GROUNDED. COULD NOT DUPLICATE. ACCOMPLISHED TEMP CONTROL, OPS TEST & BITE CHECKS IAW MM 21-61-00, OPS CHECKED NORMALSDR CA140410010Controller · failed(CAN) PAX TEMP CONTROLLER EXTREMLY HOT TO TOUCH. WOULD NOT CONTROL CABIN TEMP, SYNOPTIC SHOWED 26 DEG C. CONTROL TXDR`D TO COCKPIT AND CONTROLLER REMAINED HOT TO TOUCH. ACFT LANDED AND THE CONNECTOR FROM THE VIP PCU WAS REMOVED, BAGGED & STOWED. VIP PCU TSDR ASAA2014040507437Warning Light · false activationZONE TEMP LT CONTROL CABIN ILLUMINATED DURING RECALL. ACFT GROUNDED. CHECKED, NO HISTORY - 60 DAYS. NR 2 TEMP CONTROLLER SHOWS FLT DECK TRIM VALVE FAULT. RESET FAULT. FAULT DID NOT RETURN. OPS CHECK NR 2 TEMP CONTROLLER GOOD. REF FIM 21-62/T832. GROUND SDR ASAA2014040507434Control Valve · malfunctionedLEFT ZONE TEMP AND BLEED LIGHTS ILLUMINATE WITH APU OFF. ACFT GROUNDED. R & R AIR CONDITIONING MODULE IAW MM 21-51-65-000-801 & MM 21-51-65-400-801. PACK/ZONE TEMP CONTROL BITE IAW MM 21-51-00-700-803 SHOWED NO FAULTS, BUT WITH NEW P5-10 MODULE INSTALLED THESDR ASAA2014040307435Filter · dirtyF/A REPORTED DURING FLIGHT, MID CABIN HOT WITH BACK COLD AND FRONT COOL. ACFT GROUNDED. W/APU RAN BOTH PACKS 4 PLUS HOURS W/ MAIN CABIN TEMP SELECTORS AT VARIOUS SETTINGS. USING P5-17 CABIN TEMP INDICATOR, FOUND FWD AND AFT CABIN TEMPS, DUCT SUPPLY TEMPS MASDR ASAA2014033107377Warning Light · false activationCONT CAB ZONE TEMP LIGHT ILLUMINATED DURING MASTER CAUTION RECALL, EXTINGUSHED WHEN RESET THE MASTER CAUTION. ACFT GROUNDED. TESTED CONTROLLER IAW MM 21-61-20, STEP F. SYSTEM OPS CHECKED GOOD. NO HISTORY IN LAST 60 DAYS.SDR SWIA201436901Control Valve · failedRT PACK FAILED, RAN QRH FOR PACK FAIL. SHORTLY AFTER, SMOKE STARTED DEVELOPING IN COCKPIT. RECEIVED A TRIPLE CHIME, MASTER WARNING AND AURAL SMOKE WARNING. REPLACED RT TEMP CONTROL VALVE IAW AMM.SDR ASAA2014032707338Module · failed"ZONE TEMP" LIGHT ILLUMINATED FIVE TIMES ON CLIMBOUT, TRIED RESET SWITCH HAD NO EFFECT. ACFT GROUNDED. CONTROL CAB ZONE TEMP LIGHT REMAINS ILLUMINATED WITH INTERMITTENT MASTER CAUTION AND AIR CONT ANNUNCIATIONS. DURING TROUBLESHOOTING, REMOVED & REINSTALLEDSDR ASAA2014032607321Warning Light · false activationCONT CABIN ZONE TEMP LIGHT ILLUMINATED DURING ENGINE START. ACFT GROUNDED. PERFORMED NR 2, ZTC BITE IAW 21-62, TASK 801. NO FAULTS LOGGED CLEANED FLT DECK FILTER PRECAUTIONARY. PERFORMED SYS OPS CHECKED IAW 21-61-00. SYS CHECKED NORMAL.SDR CA140604009Ecu · fumes(CAN) FLT COMPARTMENT HOT CAUTION LIGHT AND FUMES DETECTED IN COCKPIT. THE TOILET SMOKE DETECTOR ALSO ACTIVATED. QRH CHECKLIST WAS COMPLETED AND OXYGEN DONNED AS A PRECAUTION DUE TO THE FUMES. A DECISION WAS MADE TO DIVERT TO BASE AND PAN PAN CALL DECLAREDSDR CA140407005Control Unit · failed(CAN) APPROXIMATELY 40 MINUTES INTO FLIGHT THE AIR CONDITIONING WAS SELECTED SLIGHTLY WARMER AND THIS ACTION RESULTED IN ILLUMINATION OF THE FLT COMPARTMENT PACK HOT CAUTION LIGHT. CREW ACTIONED QRH - PACK OFF, MAX BLEED, DESCEND SMELL/FUMES IN COCKPIT AND CASDR ASAA2014032407308Controller · failedUNABLE TO COOL AFT CABIN SUFFICIENTLY WITH BOTH FWD CABIN, AFT CABIN TEMP SELECTORS IN FULL COLD POSITIONS. ON GROUND SUPPLY DUCT TEMP FWD AFT 28C IN FLT 20C ALL INDICATIONS NORMAL NO ASSOCIATED LIGHTS LT PACK, TEMP 6C, RT PACK TEMP 40C THROUGHOUT FLIGHT. ACSDR SWIA2014032836856Warning Message · false indicationOVERBOARD COOL CAUTION AND INBD COOL FAIL STATUS MESSAGE. CABIN WOULD NOT PRESSURIZE. INSPECTED OVERBOARD EXHAUST VALVE AND INBD EXHAUST VALVE IAW AMM. BOTH VALVES MOVED TO CORRECT POSITIONS, PERFORMED SELF TEST OF BOTH CABIN PRESSURE CONTROLLERS. NO FAULTSSDR ASAA2014032007257Filter · dirtyFORWARD CABIN TEMPERATURE FLUCTUATES DRAMATICALLY WITH MINIMAL INPUT FROM CABIN CONTROLLER. ACFT GROUNDED. VERIFIED NO FAULTS ON PACK TEMP CONTROLLERS AND CLEANED LINT OUT OF FWD AND AFT CABIN TEMP SENSOR FAN FILTERS IAW MM 21-61-11. OPS NORMAL.SDR ASAA2014031907250Warning Message · false activationCABIN ZONE TEMP LIGHT ON MASTER CAUTION RECALL. LIGHT EXTINGUISHES WHEN MASTER CAUTION SYS IS RESET. ACFT GROUNDED. NO HISTORY. PERFORMED FIM TASK 21-62, TASK 842. NO CURRENT FAULTS, SYSTEM BITES AND RUNS NORMAL. GROUND VERIFICATION SUCCESSFUL.SDR ASAA2014031607210Modulating Valve · failedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED DURING RECALL AND EXTINGUISHED ON RESET. ACFT GROUNDED. ACCOMPLISHED PACK/ ZONE TEMP CONTROLLER BITE TEST. FLIGHT DECK TRIM VALVE LIGHT ILLUMINATED ON RT PACK / ZONE TEMP CONTROLLER. REPLACED CONTROL COMPT TRIM AIRSDR 2CCA20140311918Sensor · failedENROUTE AT FL 36.0, RECEIVED MOMENTARY RT ICE PROTECTION TEMP HIGH LIGHT. WAS ON FOR LESS THAN A SECOND. AIRFOIL ICE OFF, ENGINE ON. CABIN PRESSURE STARTED FLUCTUATING +/- 300-500 FT A MINUTE MOMENTARILLY WITH AN INTERMITTENT FLOW LIGHT. PERFORMED QRH PROCESDR ASAA2014030707101Control Valve · faultedZONE TEMP CONT CAB ILLUMINATES ON RECALL, RESETS. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMP CONT BITE TEST ON BOTH CONTROLLERS. NR 1 SHOWS NO FAULTS. NR 2 SHOWS TCV FOR FLT DECK VALVE. CLEARED FAULT, ACCOMPLISHED CABIN TEMP CONT. & IND. OPS TEST FOR 1 HRSDR QXEA2014030600207Bypass Valve · failedUNABLE TO CONTROL TEMP CABIN AND FLT DECK IN ANY SELECTION. MANUAL-AUTO RECYCLED PACKS OFF-ON. NO CHANGE. FOUND LT PACK BYPASS VALVE FAILED TO FULL HOT WITH ZERO MA FULL COLD INPUT. REPLACED LT PACK BYPASS VALVE IAW AMM 21-51-31-000-801+ 21-51-31-400-801 TSDR ASAA2014030507090Modulating Valve · failedCOCKPIT WAS VERY COLD, TURN TEMP CONTROL TO FULL WARM DUCT TEMP NEVER GOT OVER 30 TRIED IN OFF POSITON , NO CHANGE IN FULL WARM, ALL VENTS BLOWING COLD AIR. ACFT GROUNDED. DURING BITE TEST FOUND NR 1 TRIM AIR MODULATION VALVE INOPERATIVE. R & R TRIM AIR MODSDR ASAA2014030507089Warning Light · false activationCONT CAB ZONE TEMP LIGHT, EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED BITE TEST OF BOTH ZONE TEMP CONTROLLERS, NO FAULTS NOTED, IAW AMM 21-61-00.SDR CA140306008Sensor · failed(CAN) SMOKE IN THE CABIN ON THE GROUND AT ENGINE START PLACE. DURING APU COMPARTMENT INSPECTION MAINTENANCE PERSONNEL FOUND THE RT ACM TEMP SENSOR DESTROYED, MISSING OF 2 BOLTS AND LOOSING ON ACM FLANGE. THE UNCONTROLLED TEMP RISING HAS BEEN NOTICED DURING OSDR ASAA2014022707025Indicator · failedCABIN TEMP GAUGE INOPERATIVE. ACFT GROUNDED. R & R CABIN TEMP INDICATOR REF MM 21-61-32. OPS NORMAL IAW SAME. ETOPS GROUND VERIFICATION TEST PASSED.SDR ASAA2014022707024Sensor · failedAFT CAB ZONE TEMP ILLUMINATES WITH MASTER CAUTION RECALL, EXT WITH RESET. ACFT GROUNDED. ACCOMPLISHED PACK/ZONE TEMP CONT BITE PROCEDURE. FOUND FAULT LIGHT ZONE ON (TRIM VALVE) ON 1 CONT NO FAULTS ON NR 2. CLEARED FAULT. DUE TO HISTORY ACCOMP GVI OF V146 &SDR ASAA2014022406977Warning Message · false activationON RECALL CONTROL CABIN ZONE TEMP LIGHT ILLUMINATED. EXTINGUISHES WITH MC RESET. ACFT GROUNDED. ACCOMPLISHED FIM TASK 21-62 TASK 842, NO ZONE TEMP LIGHT. INTERMITTENT FAULT. ACCOMPLISHED PACK ZONE TEMP CONTROLLER BITE PROCEDURE 21-62 TASK 801, NO FAULT.SDR ASAA2014022306957Filter · dirtyCONTROL CABIN TEMP AND AFT CABIN TEMP DO NOT RESPOND TO INPUTS IN EITHER AND OR OFF, BOTH DURING CLIMB OR CRUISE. TRIM AIR SWITCH ON, BOTH RECIRCULATING FANS IN AUTO, LT PACK AND RT PACK IN AUTO, ISOLATION VALVE IN AUTO NR 1 AND NR 2 BLEED AIR SWITCHES ON APUSDR ASAA2014022306956Controller · faultedDURING RECALL, LANDING CHECKLIST, AFT CABINE ZONE TEMP LIGHT ILLUMINATED AND EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. NR 2 TEMP CONTROLLER LOGGED "CONTROLLER FAULT". REPLACED NR 2 TEMP CONTROLLER. SYSTEM BITES NORMAL IAW MM 21-62-20. GROUND SDR ASAA2014022206941Warning Light · illuminatedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATED ON RECALL, EXTINGUISHED ON MASTER CAUTION RESET. ACFT GROUNDED.SDR AALA20140221001Shutoff Valve · inoperativeJFK INFLIGHT DFW-LHR CREW REPORTED UNABLE TO CONTROL AFT CABIN TEMPERATURE. EMERGENCY DECLARED FLIGHT DIVERTED JFK LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED RT HAND PRESS REGULATING & SOV. SYS GND CHECKED NORMAL OPERATION CLOSED.SDR ASAA2014022006939Valve · faultedCONT CABIN - ZONE TEMP LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. R & R CONT CABIN - ZONE TRIM AIR MODULATING VALVE IAW AMM 21-61-21-400-801, OPS CHECKED NORMAL.SDR ASAA2014022006934Warning Light · false activationCABIN ZONE TEMP LIGHT ILLUMINATED. ACFT GROUNDED. RAN SYSTEM TEST IAW MM 21-61-00. SYSTEM OPS CHECKS GOOD.
Back to JASC 2160