JASC 2161
Service difficulty reports · 308
Reports filed under 2161 · Cabin Temperature Controller, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2161' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2161' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2020060401207Warning System · false activationFWD CGO BACKUP ADVISORY AFTER TAKEOFF. MSG CLEARED ABOUT 5 MINS LATER. PERFORMED TROUBLESHOOTING AS PER FIM 21-61 TASK 803 AND FOUND OK AT THIS TIME.SDR ABXA20200521063Controller · malfunctionedAFT CABIN TEMPERATURE EICAS MESSAGE. AIRCRAFT WAS GROUNDED.SDR P5CA2020051300160Controller · malfunctionedFWD CARGO A/C EICAS MESSAGE DISPLAYED AFTER BLOCK OUT.(<P>REMOVED AND REPLACED AUX ZONE TEMP CONTROLLER IAW AMM 21-61-12, OPS CHECK GOOD AT THIS TIME.<BR /></P>)SDR UIEA2020050801001Controller · malfunctionedAFT CABIN AND FORWARD CABIN TEMP EICAS MSG(<P>ISSUED MDDR #128108 PER MEL CH 21-61-01-02, CAT 'C'.</P><P>LP 1140486: REMOVED AND REPLACED CABIN ZONE TEMP CONTROLLER IAW AMM 21-61-03. THIS CLEARS MDDR 128108.<BR DATA-MCE-BOGUS="1" /></P>)SDR UIEA2020050801000Controller · malfunctionedFLIGHT DECK TEMP EICAS MSG(<P>TRANSFER TO MDDR #128109 IAW DDG 21-61-02-03, CAT 'C', DUE DATE 18 MAY 2020.</P><P>LP 1140486: REMOVED AND REPLACED CABIN ZONE TEMP CONTROLLER IAW AMM 21-61-03. THIS CLEARS MDDR 128109.<BR DATA-MCE-BOGUS="1" /></P>)SDR UIEA2020042400822Controller · faultyFLT DECK TEMP CAUTION MESSAGE AND INOP LIGHT.(<P>PERFORMED BITE OF ZONE TEMPERATURE CONTROLLER IAW AMM 21-61-03. FOUND CONTROLLER FAULT. REMOVED AND REPLACED ZONE TEMP CONTROLLER IAW AMM 2-61-03, OPS CHECK GOOD. NO FAULTS FOUND. OK FOR SERVICE.<BR /></P>)SDR ASAA2020041332631Controller · faultedCONT CABIN ZONE TEMP LIGHT ILUMINATED ON RECALL. GROUNDED - YES. PERFORMED B737-800 FIM 21-62 TASK 801 FOUND # CONTROLLER FLT DECK TRIM VALVE FAULT, PERFORMED BITE NO FAULTS NOTED.SDR UIEA2020040600685Controller · malfunctionedAFT CABIN TEMP EICAS MESSAGE(<P>TRANSFER TO MDDR 126634 IAW DDG 51-61-04-02, CAT C, DUE DATE 13-APR-2020.</P><P>LOG PAGE 822006: REPLACED CONTROLLER CABIN ZONE TEMPERATURE MODULE, PROBLEM RESOLVED, OPS CHECK GOOD AS PER AMM 21-61-03. THIS CLEARS MDDR 126634.</SDR P5CA2020031700086Controller · malfunctionedAFT CABIN TEMP EICAS MSG.(<P>TRANSFER TO MDDR 125899 IAW DDG 21-61-01-02, CAT 'C'.</P><P>LP 952878 - M2: RESET TEMP CONTROLLER AND ACCOMPLISHED TEST IAW AMM 21-61-00. SYSTEM FOUND OK. THIS CLEARS MDDR 125899.</P>)SDR FDEA2020012320196Controller · malfunctionedDIVERTED INTO EWRZONE TEMP DROPPED TO 38/49/26. TRIM AIR WAS MEL'D FL 370, NO A/ICE, TRIED AUTO, N, W ON PACK CONTROLLER. TEMP CONTINUED TO DROP IN ALL SETTINGS. LOST 30 DEGREES IN 50 MINS. ETURNED TRIM AIR PRESSURE REGUALTING VALVE TO NORMAL CONFIG. REMOVED ASDR UIEA2019091205488Controller · malfunctionedEICAS MSG: FLT DECK TEMP, IN BLOCKS, IN AUTO MODE. TRANSFERRED TO MDDR #117647 PER MEL 21-61-02-03, CAT C, DUE DATE: 22-SEP-19. PLACARD INSTALLED AND MCC NOTIFIED. LP 1087272 - M2: PERFORMED IAW SUPP MX MANUAL FIM 21-60-00. R/R FLT DECK ZONE DUCT OVERHEAT RELASDR P5CA2019090500178Warning System · false activationAFTER TAKEOFF, RECEIVED "FWD CARGO BACKUP" EICAS MESSAGE. WENT AWAY BY 10,000'. PERFORMED FIM 21-61 FT 803. NO FAULT INDICATIONS FOUND AND COULD NOT DUPLICATE THE FAULT. FIM 21-61 TASK 803 C/W, NO DEFECTS NOTED.SDR RAIA201909020001Coupling · disconnectedPAC #1 VALVE CLOSED IN FLIGHT. FOUND DISCONNECTED COUPLING AT DUEL TEMP CONTROLLER. RECONNECTED COUPLING AND PERFORMED OPS CHECK. LEAK CHECK OF PACK 1 OPS CHECK GOOD AT THIS TIME.SDR UIEA2019072904893Unknown · malfunctionedFLIGHT DECK TRIM AIR VALVE POSITION INDICATOR WILL NOT MOVE TO FULL COLD POSITION WHEN FLIGHT DECK COMPARTMENT TEMPERATURE CONTROL IS MOVED TOWARD "C".(<P>PERFORMED OPS CHECK OF FLIGHT DECK TEMP CONTROL SYSTEM. OPS CHECK NORMAL. ALSO VERIFIED TRIM AIR VALVE OPSDR UIEA2019072604862Warning System · false activation"FWD CGO BACK UP " EICAS MSG. (<P>TROUBLESHOOT PER FIM FT 21-61 TR 803, NO FAULTS FOUND AT THIS TIME. A/C OK FOR SERVICE.</P>)SDR UIEA2019072504841Warning System · false activationFWD CARGO AC FAULT LIGHT AND "FWD CARGO BACK UP" EICAS INTERMITTENT THROUGHOUT FLIGHT. (<P>PERFORMED BITE TEST OF ZONE TEMP CONTROL UNIT IAW AMM 21-61-03, NO FAULTS NOTED. ADDITIONALLY PERFORMED BITE TEST OF AUX ZONE TEMP CONTROL UNIT IAW AMM 21-61-12, NO FAULSDR P5CA2019071200147Warning System · false activationFWD CGO BACKUP EICAS (<P><SPAN>PERFORMED BITE ON XONE TEMP MODULE IAW FIM 21-61 FT 804. NO DEFECTS NOTED AT THIS TIME.</SPAN></P>)SDR UIEA2019071204743Unknown · malfunctioned"AFT CARGO TEMP LIGHT INOP ( COMPT TEMP INOP LIGHTS / ALL CARGO CONFIGURATION )(<P>PERFORMED BITE TEST OF ZONE TEMP CONTROL UNIT IAW AMM 21-61-03. C/W ADJUSTMENT TEST PER AMM 21-61-03</P>)SDR UIEA2019071004730Warning System · false activationFWD CGO BACKUP MSG DURING CLIMB OUT. PERFORMED QRH(<P><SPAN>NO / FAULT FOUND PER FIM 21-61 FT 922 POSSIBLE CAUSE HOT WEATHER AT DEPARTURE / STATION</SPAN><BR /></P>)SDR ASAA2019070829974Controller · faultedAFTER ENG START UPON MASTER CAUTION RECALL TEST, GOT A AMBER MASTER CAUTION LIGHT FOR FWD CAB ZONE TEMP WHICH CLEARED ON MASTER CAUTION RESET. GROUNDED - YES. ACCOMPLISHED PACK TEMP CONTROL BITE PROCEDURE PER FIM 21-62 TASK 801. FOUND ZONE TRIM VALVE CONTROLLESDR P5CA2019052800085Warning System · false activationON CLIMBOUT, FWD CGO BACKUP EICAS MSG RAN APPROPRIATE NNC, MESSAGE REMAINED. MESSAGE DISAPPEARED FIVE MINUTES LATER.(<P>TROUBLESHOT FAULT MSG FOR FWD CARGO BACKUP IAW FIM TASK 21-61-43-803, OPS CHECK GOOD. NO DEFECTS AT THIS TIME.</P>)SDR UIEA2019052404287Valve · warning messageFLT DECK TEMP EICAS MESSAGE.. REMOVED AND REPLACED FLT DECK TRIM AIR VALVE IAW AMM 21-61-00. OPS CHECK GOOD.SDR HALA2019052100253Controller · malfunctionedETOPS SIGNIFICANT SYSTEM - ONCE ON GROUND AND INFLIGHT HOT AIR 2 TRIM AIR VALVE CLOSED AUTOMATICALLY. AMBER LINE FROM VALVE TO MANIFOLD ON COND PAGE. X BLEED VALVE OPENED. RESET ZONE CONTROLLER. PERFORMED BITE TEST CAB TEMP ECS PER AMM 21-63-00. OPS TEST PASSESDR HALA2019052100252Controller · malfunctionedETOPS SIGNIFICANT SYSTEM - COCKPIT/ CABIN TEMP CONTROL UNCONTROLLABLE WHEN SET AT BASELINE SETTINGS. RESET TEMP CONTROLLERS AND PERFORMED BITE NO FAULTS NOTED. OPS CK'D NORMAL REF AMM 21-63. OK FOR SERVICE.SDR ASAA2019043029208Controller · failedON RECALL DURING AFTER START CHECKLIST MASTER CAUTION ILLUMINATED AIR CONDITIONING ANNUNCIATOR FOR LEFT PACK LIGHT ILLUMINATION ON OVERHEAD PANEL. ALL LIGHTS RESET PER CHECKLIST BY PUSHING MASTER CAUTION RESET BUTTON. GROUNDED - YES. REF FIM TASK 21-53 TASK 80SDR UIEA2019043004073Selector · faulty30 MINUTES INTO FLIGHT, COCKPIT AND FWD CABIN TEMP WENT UP 7 DEGREES IN 10 MINUTES. UNABLE TO ADJUST UNTIL TRIM AIR WAS CYCLED AND CABIN TEMP SET TO MANUAL. FLIGHT DECK TEMP INOP IN AUTO, OK IN MASDR ASAA2019031028547Indicator · failedCABIN TEMPERATURE CONTROL PANEL GAUGE SHOWS NO TEMPERATURE INDICATING WHEN LEFT OR RIGHT PACK SOURCE SELECTED. GROUNDED - YES. VERIFIED DEFECT REMOVED AND REPLACED TEMP CONT MODULE & TEMP GAUGE PER AMM 21-61-15 ALL OPS CKD NML.SDR UIEA2019030403461Controller · malfunctionedEICAS MSG "CGO CARGO FLOOR OVHEAT" STATUS MESSAGE: CARGO TRIM AIR(<P>REMOVED & REPLACED AUX ZONE TEMP CONTROL IAW AMM 21-61-12, & 21-43-05 OPS CKD SUCCESSFUL, DMI #107996 CLOSED.</P>)SDR HALA2019022500068Controller · malfunctionedOPEN - ETOPS SIGNIFICANT SYSTEM - FLIGHT DECK TEMP DIFFICULT TO CONTROL EITHER TO HOT OR TOO COLD. ZONE TEMP INDICATION OVERSHOOTS TO HIGH OR LOW. COCKPIT ZONE TEMP ROTARY SELECTOR, DOES NOT SEEM TO RESPOND IN THE MID RANGE 12 O'CLOCK POSITION. RESET PACK CONTSDR ASAA2019021428194Warning System · false activationCONTROL ZONE TEMP OFF LIGHT ON. GOES OUT WITH MASTER CAUTION RESET. GROUNDED - YES. PERFORMED A/C TEMP CONTROLLER BITE CHECK PER CONTROLLER PLACARD, ONE FAULT, NR 2 TEMP CONTROLLER FLT DECK TRIM VLV. RAN CONTROLLER BITE & RESET, NO FAULTS NOTED. RAN NR 2 CONTRSDR UIEA2019012803043Controller · malfunctionedFWD CABIN TEMP CONTROLLER EICAS(<P>RESET SYSTEM PER ZONE TEMP CONTROLLER AMM 21-00-00-449 OPS CHECK NORMAL</P>)SDR ASAA2019012327917Controller · failedNR 1 PACK REGULATOR FAULT.2 PRIOR INLET ACTUATORS REPLACED, NEEDS T/S, HAS HISTORY. GROUNDED - YES. REMOVED AND REPLACED NR 1 ACSC IAW AMM 21-61-34 OPS CHECK NORMAL RAN PACKS FOR OVER AN HOUR AND NO FAULTS NOTED.SDR ASAA2019011827862Warning System · false activationFWD CAB ZONE TEMP LIGHT ILLUMINATES UPON MASTER CAUTION RECALL AFTER ENGINE START - TEMP CONTROLLER IN FULL COLD OR FULL HOT SHOWED SUPPLY DUCT TEMP OF 18C CABIN TEMP INDICATED 24C. GROUNDED - YES. ACCOMPLISHED PACK TEMP CONTROL BITE PROCEDURE PER FIM 21-62 TASDR UIEA2019011400085Warning System · false activationHI FLOW INHIBIT ON STATUS PAGE(<P>PERFORMED PACK TEMP CONTROL BITE CHECK REF FIM 21-61-00 FAULT TREE 803 MSG CLEARED NO DEFECTS NOTED</P>)SDR ASAA2018123127645Controller · malfunctionedAFT CAB ZONE TEMP LIGHT ILLUMINATES UPON RECALL. GROUNDED - YES. RESET THE AFT CABIN ZONE TEMP CONTROLLER AND ACCOMPLISHED BITS. VERIFIED AFT CABIN TRIM AIR MODULATION VALVE MODULATES, OPS CK GOOD IAW AMM 21-61-00-700-806-002.SDR HALA2018121700663Controller · malfunctionedETOPS SIGNIFICANT SYSTEM - COCKPIT TRIM AIR TEMPERATURE WAY TOO HOT. 125-130. TWICE RESET ZONE CONTROL WITHOUT EFFECT. RESET TEMP CONTROLLER PER A330 AMM 21-63. OPS CHECK GOOD. NO FAULTS. CLEANED TEMP SENSOR. OPS CHECK GOOD. OK FOR SERVICE.SDR ASAA2018120427212Controller · faultedON TAXI OUT FWD CAB ZONE TEMP LIGHT ILLUMINATED, OUT WITH RESET. GROUNDED - YES. PERFORMED BITE TEST ON BOTH PACK TEMPERATURE CONTROLLER PER FIM 21-62 TASK 801 FOUND ZONE FAULT ON CONT NR 2, CLEARED ZONE SELECTOR FAULT ON NR 2 CONTROLLER.SDR UIEA2018090501896Selector · faultyFLIGHT DECK TEMP AUTO MODE INOPERATIVE. REMOVED AND REPLACED FLIGHT DECK TEMP SELECTOR. OPS CHECK NORMAL IAW AMM 21-61-04.SDR UIEA2018083101859Sensor · faultyFLT DECK TEMP EICAS. MANUALS WORKS FINE. REPLACED FLIGHT TEMP SENSOR SELECTOR IAW AMM 21-61-04. OPS CHECK NORMAL.SDR ASAA2018072525528Warning System · false activationCONT CAB ZONE TEMP LIGHT ILLUMINATES DURING RECALL. ZONE TEMP LIGHT EXTINGUISHES WHEN MASTER CAUTION IS RESET. GROUNDED - YES. PERFORMED PACK/ZONE TEMP CONTROLLER NR 1 AND NR 2 BITE TEST REF AMM 21-61-00-700-806-002. NR 2 CONTROLLER HAS "FLT DECK" FAULT. FAULTSDR DALA2018072504692Controller · faultyATB- DL236 TWO HOURS OUT, CREW REPORTED THERE WAS ONE HUNDRED AND TWENTY DEGREE HOT AIR ENTERING THE COCKPIT. MAIN CABIN WAS ALSO HOT. CONSULTED WITH MAINTENANCE CONTROL BUT NO FIX. ACFT RETURNED TO DTW. MAINTENANCE REPLACED ZONE CONTROLLER, HOT AIR VALVE 638HSDR ASAA2018071425469Controller · failedZONE TEMP LIGHT ILLUMINATED ON FWD CABIN TEMP CONTROL. EXTINGUISHED ON MASTER RESET. CANNOT CONTROL SUPPLY DUCT TEMP WITH TEMP SELECTOR KNOB. GROUNDED - YES. NR 2 P/Z CONTROLLER LOGGED FWD ZONE CABIN SENSOR FAULT. REF AMM 21-61-10 CLEANED SENSOR, NO HELP. UNABSDR UIEA2018070601359Control Box · malfunctionedFWD ZONE TEMP CONTROLLER. REMOVED AND REPLACED FWD ZONE TEMP CONTROL BOX. PERFORMED BITE TEST SYS TEST NORMAL AT THIS TIME.SDR ASAA2018070225239Controller · malfunctionedON DESCENT CHECKLIST AND RECALL RIGHT PACK LIGHT STAY ILLUMINATED. RAN QRH AND LIGHT EXT. WHEN RESET MASTER CAUTION. GROUNDED - YES. PERFORMED PACK ZONE/TEMP CONTROLLER BITE TEST ON NR 1 & NR 2 CONTROLLER PER AMM 21-61-00-700-806-002. NR 2 CONTROLLER SHOWS RT SDR ASAA2018052224765Controller · faultyFWD CAB ZONE TEMP ILLUMINATED ON RECALL, LIGHT EXTINGUISHED ON MASTER CAUTION SYSTEM RESET. GROUNDED - YES. NR 2 PACK ZONE TEMP CONT SHOWS "FWD CABIN ZONE" SENSOR FAULT DURING BITE TEST. SAME AS "HISTORY" FAULT CLEARS ON VERIFY. NR 1 D2TC - NO FAULTS. ON BITE SDR ASAA2018041024208Sensor · faultyNR 1 A/C PACK REGULATOR FAULTED. ACFT GROUNDED. ACCOMPLISHED COMPUTER RESET IAW TSM 24-00-00-810-818, AIRCRAFT OK FOR SERVICE. REMOVED AND REPLACED THE P1 COMP TEMP (12HH) SENSOR IAW AMM 21-61-11, PB401, CONF 00.SDR ASAA2018040324142Selector · failedCONT CAB TEMP CONTROLLER IS NOT COMMANDING TEMP ABOVE 21C UNTIL KNOB POSITION REACHES NEAR FIRST HASH MARK AT 1 O'CLOCK POSITION. AT THAT POINT, THE TEMP SPIKES TO 60C. POSITIONING THE CONT CAB TEMP CONTROLLER TOWARD THE 10 O'CLOCK HASH MARK SLOWLY LOWERS TEMPSDR UIEA2018022700289Not Reported · malfunctionedROW 30 EXTREME HEAT AT SIDEWALL. PRIOR TO EACH FLIGHT, REVIEW CMC FOR ADDITIONAL FAULTS RELATED TO ZONE TEMP.SDR ASAA2017092622054Controller · malfunctionedRIGHT PACK LIGHT ILLUMINATES ON MASTER CAUTION RECALL. EXTINGUISH ON MASTER CAUTION RESET. GROUNDED - YES. RESET PACK CONTROLLER, REF AMM 21-61-00. OPS CHECK GOOD.SDR ASAA2017091921979Controller · malfunctionedAFTER ENGINE START CHECKLIST- ON RECALL- ALL 3 CABIN ZONE TEMP LIGHTS ILLUMINATED. GROUNDED - YES. RESET NR 1 AND NR 2 ZONE TEMP CONTROLLERS, REF AMM 21-61-20. NO FAULTS NOTED.
Back to JASC 2161