JASC 2161

Service difficulty reports · 308

Reports filed under 2161 · Cabin Temperature Controller, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2161'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR P5CA2017091200325Controller · malfunctionedEICAS MESSAGE FWD CARGO BKUP. RESET ZONE TEMP CONTROL SYS AND ZONE TEMP CONTROLLER BITE TEST PERFORMED AS PER AMM 21-61-00 'OK' & NIL FAULTS NOTED.Sep 12, 2017 · N647GT · Boeing 767306SDR P5CA2017062800212Controller · malfunctionedAFTER T/O RECEIVED EICAS "FWD CARGO BACKUP" ACCOMPLISHED QRH, PERFORMED FIM 21-61-812 FIG 112 AND RESET AUX TEMP CONTROLLER. BITE TEST SHOWS GOOD SYSTEM OK FOR CONT SERVICE.Jun 28, 2017 · N647GT · Boeing 767306SDR ASAA2017051020702Controller · faultedZONE TEMP LIGHT ILLUMINATES WITH DURING RECALL - CONT CAB ZONE TEMP LIGHT. GROUNDED - YES. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE TEST. NR 1 CONTROLLER TEST PASSED NO FAULTS. NR 2 CONTROLLER SHOWED FLIGHT DECK FAULT. RESET NR 2 CONTROLLER, TEST PASSED, NOMay 10, 2017 · N535AS · Boeing 737890SDR ASAA2017050320627Controller · malfunctionedREF MEL 21-32B RH PACK LIGHT FAILS TO EXTINGUISH AFTER RECALL AND MASTER CAUTION RESET. GROUNDED - YES. REF AMM FIM TASK 21-61-801 RESET BOTH ZONE TEMP CONTROLLERS ALL FAULTS CLEARED MASTER CAUTION LT NOW DOES NOT ILLUMINATE AND EXTINGUISHED OK FOR CONTINUED SMay 3, 2017 · N587AS · Boeing 737890SDR ASAA2016091718043Controller · failedON RECALL, LT PACK, CONTROLLER CAB, PACK AND ZONE LIGHTS ILLUMINATED. ACFT GROUNDED. FOUND LT PACK CONTROLLER INOPERATIVE. BITE NOT FUNCTIONING. CYCLED C/B, NO HELP, REQUIRES NEW PFTC. R & R PACK FLOW TEMPERATURE CONTROLLER IAW AMM 21-61-17-020-801, 21-61Sep 17, 2016 · N428AS · Boeing 737990ERSDR DALA2016083106319Controller · faultyAT FL360, CABIN TEMP WAS REPORTED TOO COLD. RIGHT PACK TEMP CONTROL VALVE WOULD NOT MOVE TO FULL HOT IN AUTO. WORKS OK IN MANUAL. LEFT PACK WOULD NOT GO PAST 3/4 HOT IN AUTO OR MANUAL. CYCLED AIR SUPPLY ON THE LT PACK. RESULT WAS LT PACK FAIL. SINGLE PACAug 30, 2016 · N940DL · Doug MD88SDR ASAA2016072517541Controller · inoperativeFLIGHT DECK PRIMARY TEMP CONTROLLER INOPERATIVE. ACFT GROUNDED. PERFORMED BITE OF BOTH PZTC IAW FIM 21-62, TASK 801. UNABLE TO VERIFY, FAULT RESET AND LT PACK LIGHT NO LONGER ILLUMINATES ON RECALL.Jul 25, 2016 · N513AS · Boeing 737890SDR UIEA2016072000602Controller · inoperativeFWD AND AFT TEMP TEMP CONTROLLERS INOPERATIVE. PERFORMED ZONE TEMP CONTROLLER BITE IAW AMM 21-61, FAULT TREE 803, NO FAULTS NOTED. SYS CHECK OK.Jul 18, 2016 · N649GT · Boeing 767375SDR ASAA2016070117209Controller · malfunctionedAFT ZONE TEMP ILLUMINATED RESET ON RECALL. COMPLETED QRH. ACFT GROUNDED. FAULT CHECKED NR 1 CONTROLLER TRIM VALVE. RESET CONTROLLER. NR 1 & NR 2 TEMP CONTROLLERS BITE CHECK NORMAL. RAN LT & RT AC PACKS FOR 10 MINUTES AT GATES. PACKS OPS CHECK NORMAL. BJul 1, 2016 · N442AS · Boeing 737990ERSDR 9JLA2014122604978Controller · defectiveCOULD NOT CONTROL THE TEMPERATURE FOR THE FLIGHT DECK OR CABIN. TROUBLESHOOTING FOUND THE LOW LIMIT SENSOR CONTROLLER & THE LOW LIMIT PROPORTIONING VLV BOTH TO BE DEFECTIVE, UNITS REPLACED. OPERATIONS CHECKED OK.Nov 21, 2014 · N404BL · Beech 400ASDR ANCF2014070602Controller · malfunctionedDURING CLIMB AFTER TAKEOFF AIR PACK TWO REGULATOR FAULT WAS DISPLAYED, ALSO HOT AIR FAULT, TRIM AIR SYS FAULT, AFT & FWD CABIN TRIM VLV FAULT. IAW TSM 21-61-00-810-900 PERFORMED SWAP BETWEEN ACSC 1 & ACSC 2 IAW AMM 21-61-34-000-002-A & 21-61-34-400-002-A. OPJul 6, 2014 · N281AV · Airbus A320214SDR CALA2013122093845Controller · inoperativeFLT DECK TEMP VERY HARD TO CONTROL, HAD TO USE MANUAL, PER CREW. FLT DECK TEMP CTRL INOPERATIVE, USE MANUAL, DEFERRED IAW MEL.Dec 20, 2013 · N677UA · Boeing 767322SDR N6WA20131216001Controller · faultyLEFT PACK FAULT MESSAGE. R & R NR 1 ACSC IAW CRJ700 AMM 21-61-04. OPERATIONS CHECKED GOOD AT THIS TIME.Dec 16, 2013 · N161GJ · Cndair CL6002C10SDR CALA2013121693723Controller · faultyLOWER FCV VLV ON RT PACK IS CYCLING ON & OFF. REPLACED RT CABIN TEMP CONTROLLER IAW MM. LOADED SOFTWARE IAW MM, GND CHECKED NORMAL.Dec 14, 2013 · N206UA · Boeing 777222SDR CALA2013120393410Controller · faultyCOCKPIT DUCT OVERHEAT DISPLAYED ON UPPER ECAM SCREEN. TEMPERATURE SHOWS 212, HOT AIR SW IS OFF, TEMPERATURE NOT COMING DOWN, COCKPIT IS COOL. REPLACED DUCT SENSOR 15HK & ZONE CONTROLLER 8HK IAW AMM TASK 21-63-15-000-001 & AMM TASK 21-63-34-000-001-A IAW PTTNov 30, 2013 · N415UA · Airbus A320232SDR CALA2013110892740Controller · faultyBUILDING HISTORY OF "HOT AIR FAULT" ECAM WARNINGS. RECENT LEG FAULTED "NO ZONE CTL DATA" AT FLT PHASE 4. REPLACE ZONE CONTROLLER, PCN 565-9207, IAW AMM 21-63-34.Nov 5, 2013 · N483UA · Airbus A320232SDR CALA2013102292273Actuator · faultyPACK 2 RAM AIR FAULTS. DUE TO REPEAT FAULTS ON AHM FOR PACK 2 RAM AIR OUTLET ACTUATOR. R & R THE PACK 2 RAM AIR OUTLET ACTUATOR FIN 29HH IAW AMM 21-61-52 PB401. IAW IPC 21-61-03-13A PCN 565-9028. TEMP CONTROL SYSTEM OPERATIONS CHECKED GOOD.Oct 22, 2013 · N803UA · Airbus A319131SDR CALA2013101191974Controller · inoperativeCOMPARTMENT TEMP INOPERATIVE LIGHT ALL 3. REPLACED ZONE TEMP CONTROLLER & OPERATIONS CHECKED GOOD.Oct 10, 2013 · N589UA · Boeing 757222SDR CALA2013100291663Controller · faultyREPEAT HOT AIR FAULT. REPLACED IAW AMM 21-63-34 TESTED, NO FAULTS NOTED, OPERATIONS CHECKED GOOD.Sep 27, 2013 · N841UA · Airbus A319131SDR CALA2013082690724Controller · faultyBITE TEST ZONE CONTROLLER, FAULTING CONTROLLER.Aug 24, 2013 · N648UA · Boeing 767322SDR UALA2013071805055Circuit Card · failedCABIN AND FLT DECK TEMP WENT FULL COLD AFTER TAKEOFF. TURNING TRIM AIR OFF, STABILIZED TEMPS. REPLACED M284 FLOW CONTROL CARD & PACK OVERHEAT SWITCH ON RT PACK. OPS CHECKED GOOD ON GROUND. TURNING TRIM AIR OFF STABILIZED TEMPS. REPLACED TEMP BULB, REPLACJul 17, 2013 · N558UA · Boeing 757222SDR UALA2013032802001Controller · faultyCABIN TEMPERATURE STAYS UNUSUALLY WARM FROM THE 1ST CLASS BULKHEAD TO THE OVERWING EXITS. NO FAULTS FOUND ON PFR, OR PREVIOUS LEGS REPORT. REPLACED ZONE TEMP CONTROLLER CHK BITE OK. OPERATIONAL CHECK GOOD.Mar 27, 2013 · N444UA · Airbus A320232SDR UALA2012120607068Controller · faultyNEED TO REPLACE ZONE TEMP CONTROLLER DUE TO FWD, MID, ZONE TEMP FAULT. VERY ERRATIC ON ECS PAGE. VERY ERRATIC ON ECS PAGE. REPLACED ZONE TEMP CONTROLLER. FWD AND MID CABIN TEMPS ROSE TO 76 AFTER 30 MIN AT 69. MOVED CTRL SLIGHTLY, NOW BACK TO 69. FWD AND Dec 5, 2012 · N644UA · Boeing 767322SDR UALA2012120607054Controller · failedFOUND CAB TEMP CONTROLLER FAILED MSG ON UPPER ECAM. REPLACED ZONE CONTROLLER PER MM AND ACP OPS TEST PER MM, ALL CHECK'S NORMAL.Dec 5, 2012 · N454UA · Airbus A320232SDR UALA2012113006878Controller · faultyFLT DECK TEMP CONTROL FULL WARM AND VALVE SHOWS FULL WARM BUT ONLY PUTS OUT COLD AIR. SAMC TEXT: PER VERBAL FROM FLT CREW. COLD TEMPS IN BOTH COCKPIT AND CABIN. STANDBY W-NO HELP. STANDBY ON DID HELP BRING TEMPS UP. ACP BITE CHECKS ON ZONE TEMP AND AUX TNov 28, 2012 · N644UA · Boeing 767322SDR UALA2012112606789Actuator · faultyCABIN TEMP IS IMPOSSIBLE TO CONTROL. CONSTANT COMPLAINTS FROM PAX. REPLACED RT RAM OUTLET ACTUATOR, OPS CHECK NORMAL.Nov 25, 2012 · N427UA · Airbus A320232SDR UALA2012111406570Controller · faultyWARM AIR IS STILL SUPPLIED TO FORWARD CABIN WITH RESPECTIVE ZONE TEMP CONTR IN FULL COLD. CLEAN AND TEST TEMP SENSORS (21HK AND 22HK). REPLACED 8HK ZONE CONT PER AMM 21-63-34. GND TEST OKAY.Nov 12, 2012 · N422UA · Airbus A320232SDR UALA2012092905532Controller · faultyFORWARD CABIN COLDER THAN SELECTED WITH SWITCH ON & TEMP CONTROL IN AUTO. INOP LIGHT EXISTING. PRESS ECS REC BUTTON AND RECORD ZONE TEMPS. REPLACED ZONE TEMP CONTROLLER PER MM. ACCP SVC TIP 21-61-00, NO FAULTS ON PACK TEMP CONTROLLERS AND ZONE TEMP CONTROLSep 27, 2012 · N590UA · Boeing 757222SDR UALA2012090404989Controller · faultyRIGHT PACK WENT FULL HOT IN AUTO AND STBY-C UNABLE TO STABILIZE CABIN TEMP. TRM AIR OFF FIXED IT. REPLACED ZONE TEMP CONTROL.Aug 30, 2012 · N578UA · Boeing 757222SDR UALA2012082904845Controller · faultyCOCKPIT TEMP FAULTY, RTFL. UNCONTROLLABLE IN AUTO OR MAN OR TRIM AIR SWITCH OFF. REPLACED ZONE TEMP CONTROLLER PCN 563-9027. ALSO REPLACED TS175 AND TS201 SENSORS. COCKPIT TEMP OPS CHECKS GOOD.Aug 29, 2012 · N578UA · Boeing 757222SDR UALA2012032601920Controller · faultyCOCKPIT TEMPERATURE TOO WARM, TURNED OFF TEMP CONTROLLER TO COOL COCKPIT. REPLACED ZONE TEMPERATURE CONTROLLER. TWO SEGMENTS LATER THE COCKPIT TEMPERATURE BECAME VERY COLD. REPLACED TRIM AIR PRESSURE REGULATING VALVE.Mar 24, 2012 · N546UA · Boeing 757222SDR MYWA120036Accessory Unit · malfunctionedETOPS SIGNIFICANT SYSTEM: FWD PASSENGER CABIN AND FLIGHT DECK ZONE TEMPERATURE HARD TO WARM UP. REMOVED AND REPLACED RT PACK AIR CONDITIONING ACCESSORY UNIT IAW AMM 21-61-00. SYSTEM OPS CHECK OK.Mar 20, 2012 · N752MA · Boeing 73748ESDR UIEA2012031900096Controller · inoperativeFWD CABIN TEMP CONTROLLER INOPERATIVE.Mar 18, 2012 · N640GT · Boeing 76738ESDR ASAA12511146Controller · malfunctionedCONT CABIN ZONE LIGHT ILLUMINATED DURING CLIMBOUT. ACCOMPLISHED GRH ITEMS. ZONE LIGHT EXTINGUISHED AFTER PRESSURE MASTER CAUTION. PERFORMED BITE TEST OF BOTH PACK/ZONE TEMP CONTROLLERS REF AMM 21 61 00, NR 2 CONTROLLER DISPLAYED FLIGHT DECK TRIM VALVE FAULTFeb 25, 2012 · N516AS · Boeing 737890SDR UALA2012022701188Controller · inoperativeFLT DECK TEMP CONTROLLER INOP. TEMP DOES NOT MODULATE, STAYS AT 70 DEGREES. SAMC TEXT: CREW REPORTS WHEN LEFT PACK IN STANDBY, 1 HOUR INTO THE FLIGHT COCKPIT TEMP TOO COLD AT 60 DEG. TURNED OFF LEFT PACK. REPLACED PACK STBY TEMP SNR AND REPAIRED GRD WIRE AFeb 25, 2012 · N546UA · Boeing 757222SDR UALA2012022201085Controller · faultyOFF THE GATE RECEIVED FLT DECK FWD CABIN AND AFT CABIN ZONE TRIM VALVES INOPERATIVE LIGHT. CYCLING AUTO AND OFF NO CHANGE PER CREW. REPLACED ZONE TEMPERATURE CONTROLLER PER MM.Feb 21, 2012 · N597UA · Boeing 757222SDR CNMA2012020001Control Valve · stickingSTRONG BURNING PLASTIC ODOR BETWEEN ROWS 25-35, ODOR STRONGEST ON RIGHT OF ACFT. COMPLETED NNC8.5 1-9 CONTINUED FLIGHT WITHOUT FURTHER OCCURANCE. R & R ZONE TRIM "C" VALVE IAW MAINT, MESSAGE 21-20009 IAW AMM 21-61 RAN ALL PACKS AT VARIOUS TEMPS FOR APPROX 2Feb 15, 2012 · N918AX · Boeing 777222SDR MYWA120013Controller · malfunctionedETOPS SIGNIFICANT SYSTEM: ZONE TEMP LIGHT ILLUMINATES ON RECALL. F/M ADVICED CONTROLLER 1 HAD THE LIGHTS ILLUMINATED. REMOVED AND REPLACED PACK/ZONE TEMP CONTROLLER NR 1 AND OPS TEST OK IAW AMM 21-61-20.Jan 30, 2012 · N734MA · Boeing 7378Q8SDR ASAA12510954Controller · malfunctionedLEFT PACK ILLUMINATES WITH MASTER CAUTION RECALL. PERFORMED A BITE CHECK OF THE PACK/ZONE TEMP. CONTROLLER REF FIM TASK 21 62 00 810 801 FOUND THE TCV ON CONTROLLER NR 1 HAS AN INTERMITTENT FAULT. CLEARED FAULT SYSTEM OPS NORMAL BY GROUND VERIFICATION.Jan 16, 2012 · N517AS · Boeing 737890SDR DXTA2012011604846Controller · inoperativeDURING TAXI AFTER FLT, LOST CONTROL OF CABIN TEMP WITH APU BLEED AIR ON. CABIN TEMP CONTROLLER WOULD NOT CONTROL VALVE IN AUTO OR MANUAL MODES. PRODUCED SMOKE FROM CABIN FLOOD VENT. SHUTDOWN APU. SMOKE CEASED. NO PROBLEMS DURING FLIGHT. CABIN TEMP OPERATEJan 15, 2012 · N896QS · Raythn HAWKER800XPSDR ASAA11510805Controller · malfunctionedPACK LIGHT ILLUMINATED DURING RECALL DURING LANDING CHECK. PERFORMED PACK ZONE TEMP BITE CHECK ON NR 1 & NR 2 ZONE TEMP CONTROLLERS PER AMM 21 61 00 700 806 002 NR 1 TEMP CONTROLLER CHECKS GOOD NR 2 TEMP CONTROLLER HAD A " RAM AIR ACT" FAULT. RESET FAULTS ONDec 17, 2011 · N559AS · Boeing 737890SDR UALA2011121406852Controller · faultyCOND TEMP SENSOR RT STATUS MESSAGE DISPLAYED -MSG 21-23402- VALVE INOP IN OPEN POSITION WITH CONNECTOR TIED BACK. REPLACED RT CTC. RE-ACTIVATED RT LOW LIMIT VALVE.Dec 12, 2011 · N773UA · Boeing 777222SDR UALA2011120906767Controller · faultyFWD CABIN TEMP EICAS DISPLAYED. NO FAULTS ON GRD, BITE OKAY. REPLACED ZONE TEMP CONTROLLER PER MM, BITE OK. ALSO CLEANED FWD ZONE TEMP SENSOR.Dec 9, 2011 · N654UA · Boeing 767322SDR ASAA11510771Controller · faultyON RECALL OF MASTER CAUTION "SIX PACK" RIGHT PACK LIGHT ILLUMINATED. CREW REPORTS LIGHT GOES OUT W/MASTER CAUTION RESET. FOUND NR 2 CTRLR TO HAVE A CONTROLLER FAULT OF PACK/ZONE (IN BIT TEST). REPLACED NR 2 TEMP CTRLR. OPS CHECK GOOD.Dec 8, 2011 · N577AS · Boeing 737890SDR UALA2011120606720Controller · faultyAFT CABIN TEMP EICAS MESSAGE WITH INOP LIGHT ON. RESET ZONE TEMP CONTROLLER - NO HELP. CW MEL. REPLACED ZONE TEMP CONTROLLER PER MM, OPS CHECK GOOD. NO EICAS MESSAGES OR FAULTS.Dec 5, 2011 · N652UA · Boeing 767322SDR MYWA110112Controller · out of adjustETOPS SIGNIFICANT SYSTEM: ALL THREE ZONE TEMP LIGHTS ILLUMINATE ON RECALL EXTINGUISH WHEN SYSTEM IS RESET FAULT CODE 216 224-00. C/W ZONE TEMP CONTROL ADJUSTMENT TEST NO DEFECTS NOTED AT THIS TIME IAW AMM 21-61-00.Nov 6, 2011 · N734MA · Boeing 7378Q8SDR ASAA11510616Controller · malfunctionedLEFT PACK LIGHT ILLUMINATED. RESET LT PACK/ZONE TEMP CONTROLLER PER MM 21 61 00 AND TESTED SYSTEM, SYSTEM OP CHECKS GOOD. NO DEFECTS NOTED.Nov 3, 2011 · N517AS · Boeing 737890SDR ASAA11510410Controller · malfunctionedRIGHT PACK LIGHT ILLUMINATE ON RECALL: RESETS WITH MASTER CAUTION. BITE TESTED ZONE TEMP CONTROLLERS AND FOUND FAULT ON NR 2 CONTROLLER TCV THIS PACK. RESET AND RAN RIGHT PACK PER FIM 21 62 00 810 831. TESTS OK. NO FAULTS.Sep 23, 2011 · N559AS · Boeing 737890SDR UALA2011082904630Controller · faultyAIRPLANE HAS POCKETS OF HOT AND COLD AREAS -TEMP HARD TO CONTROL. REPLACED RT CABIN TEMP CONTROLLER PER MM. OPS NORMAL.Aug 25, 2011 · N782UA · Boeing 777222SDR UALA2011081804398Modulating Valve · faultyAFT CABIN TEMP EICAS. PERFORMED BITE ZONE TEMP CONTROLLER, FOUND AFT TRIM AIR VALVE FAULT, DEFERRED AFT TRIM AIR VALVE PER MEL 2161BB, VALVE SHOWED CLOSED ON EICAS, SECURED CLOSE PER CB'S PULL OUT IAW MEL PROCEDURE 1. REPLACED AFT TRIM AIR VALVE, NO HELP. SAug 17, 2011 · N651UA · Boeing 767322
Back to JASC 2161