Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2026040802236Coffeemaker · damagedAFTER PUSHBACK AND ENGINE START AFT FA'S CALLED TO REPORT AN ELECTRICAL BURNING SMELL. NO VISIBLE SMOKE OR FIRE REPORTED. PASSENGER IN 29DEF ALSO REPORTED THE ODOR. WALK AFT NOTICED THE SMELL BEGINNING AROUND ROW 15. AND A STRONGER ODOR IN THE AFT GALLEY NEAR SDR CALA2026040615067Oven · dirtyCABIN CREW REPORTS ACRID ODOR IN MID GALLEY DURING LDG SHUT OF F PWR. PERFORMED CABIN INSPECTION. REF 05-51-58-800-801-C3. FOUND FWD GALLEY OVEN 203 INTERIOR NEEDS TO BE SCRUB AND CLEAN, CAUSING ODOR IN THE CABIN. CB IS PULLED AND PLACARD INSTALLED.SDR CALA2026040715130Oven · contaminatedFRONT OVENS SMELLING OF CAMPFIRE. NO SMOKE NOR EVIDENCE OF FLAME . DISCONTINUED USE. PLACING BOTH FIRST CLASS GALLEY OVENS ON DEFERRAL IAW NEF 2510AU. FOUND FWD GALLEY OVEN 204 WITH BURNED PAPER DEBRIS. REMOVED DEBRIS AND CLEANED INSIDE OF OVEN PERFORMED OSDR AALA202604078618Oven · odorAIRCRAFT WAS NOT GROUNDED: ON DEPARTURE A STRONG ODOR WAS SMELLED THROUGHOUT THE ENTIRE AIRCRAFT. THE SMELL WAS A MIX OF BURNING PLASTIC AND BURNING FOOD HOWEVER THE FLIGHT ATTENDANT REPORT THE OVEN IS EMPTY AND OFF. REMOVE AND REPLACED OVEN NUMBER 1 (AALA2026SDR AALA202604072084Oven · odorAIRCRAFT WAS NOT GROUNDED: ON DEPARTURE A STRONG ODOR WAS SMELLED THROUGHOUT THE ENTIRE AIRCRAFT. THE SMELL WAS A MIX OF BURNING PLASTIC AND BURNING FOOD HOWEVER THE FLIGHT ATTENDANT REPORT THE OVEN IS EMPTY AND OFF. REMOVE AND REPLACED OVEN NUMBER 1 (AALA2026SDR CALA2026040615093Oven · faultedOVEN SMOKING OR SPARKING 204 OVEN 204 SMOKE BUILDS AND SMELLS WHEN IN USE. CREW CONFIRMED NO SPARK OF ANY KIND, LIGHT TO MODERATE SMOKE INTERNALLY ONLY. OVEN IS EMPTY, REMOVED AND REPLACED OVEN 204 IAW AMM 25-34-00-000-801-C3 & 25-34-00-000-801-C4. OVEN 204 OPSDR CALA2026040615090Oven · faultedOVEN 705 HAD A BURNING ELECTRICAL ODOR. OVEN OFF & SECURED. NO SMELL, REMOVED OVEN CHK BRACKET IS CLEAN. WIRE BUNDLE CLEARANCE IS ENOUGH, RECEPTACAL IS NML AS WELL. SVC REQ'D SHOW ON INDICATOR AFTER 2 MINS WARM UP. PULL OUT CB. PLACARDED INOP. REMOVED ASDR CALA2026040315065Coffeemaker · unlockedCOFFEEMAKER 106 FOUND TO BE UNLOCKED AND SLIDING OFF RAIL. REINSTALLED AND LOCKED CM106. OPS CK GOOD REF AMM 25-32-01. FLAGGED SDR FOR SAFETYSDR CALA2026040315051Oven · odorOVEN SMELLS BAD DR-4L ATTENDANT PANEL OVEN 809 HAS BAD SMELL NOT USING IT FOR FLT OPT TEST OF OVEN 809 FOUND SMELL BAD FROM THE INSIDE OF OVEN ELETRICAL UNIT, PART NIS AT TPE, REQUEST TO NEF 2520AV. DEACTIVATED THE C/B OF OVEN 809. OK TO DEFER OVEN 809 INOP INSDR AALA202604075879Oven · odorAIRCRAFT WAS GROUNDED: SLIGHT BURNING SMELL WHEN OVENS IN FORWARD GALLEY WERE USED. ACCOMPLISHED J/C 09L00021001 DETERMINED SOURCE OF SMELL TO FORWARD GALLEY NUMBER 1 OVEN. REMOVED AND REPLACED NUMBER 1 FORWARD GALLEY OVEN. PER CMM 25-37-26. OPS CHECK GOOD.SDR CALA2026040615085Oven · fumesAT CRUISE FL320 FUMES IN MID CABIN TURN OVENS OFF..FUMES DISSIPA TED SUSPECT OVEN 405. INSTALLED OVEN IN REF WITH AMM B787-A-25-32-00-10A-720A-A. OPS CHECK GOOD.SDR SWAA2026040785727Trash Bin · dirtyELECTRICAL ODOR AFT GALLEY, STRONGER FO SIDE AND LOWER BY FLOOR. INSPECTED AFTER GALLEY AREA. FOUND ODOR COMING FROM GALLEY TRASH BINS. CLEANED TRASH BINS. NO SMELLS NOTED. AMM 05-51-56.SDR VNAA2026040315701Coffeemaker · odorBURNING SMELL COMING FROM GALLEY / PERFORMED SEVERAL OPS CHECKS/BREW CYCLES OF BOTH COFFEE POTS IAW CRJ 700 AMM 25-32-06-710-801 AND WHILE BREWING, NOTICED ABNORMAL SMELL COMING FROM BOTH COFFEE POTS AND SUSPECT BOTH COFFEE MAKERS TO BE FAULTY. REMOVED AND REPSDR CALA2026040114987Cart · odorVERBAL FROM CABIN CREW LEAD UPON DOOR OPENING. FOUL SMELL OF EXHAUST OR FUEL IN FWD AND AFT GALLEYS PERFORMED AMM 05-51-00 SMELL OR SMOKE IN CABIN INSPECTION. APU WAS OFF WHEN SMELL WAS ENCOUNTERED IN BOTH FWD AND AFT GALLEYS. FOUND DRY ICE IN GALLEY CARTS INSDR AALA202603313925Oven · odorAIRCRAFT WAS NOT GROUNDED: STRONG BURNING SMELL FROM FORWARD GALLEY OVEN NUMBER 1 WHEN IN USE AND SET ON LOW. REMOVED AND REPLACED GALLEY OVEN NUMBER 1. PER AMM 25-32-03. OPS CHECK GOOD.SDR CALA2026033114969Coffeemaker · odorFUMES COMING FROM FWD COFFEE MAKER. PULLED COFFEE MAKERS 105 & 106, INSPECTED AREA AND DID NOT FIND ANY OBVIOUS DEFECTS. REPLACED FWD GALLEY COFFEE MAKERS 105 & 106, BREWED 2 POTS OF COFFEE IN EACH COFFEE MAKER AND HAD NO BURNING ODOR, ORD FIRE DEPT CHECKED ASDR AALA202603318438Oven · smokeAIRCRAFT WAS NOT GROUNDED: WISPY SMOKE FROM FIRST CLASS OVEN THE LEFT DOOR. VERIFIED FORWARD GALLEY NUMBER 2 INOPERATIVE. REMOVE AND REPLACED OVEN NUMBER 2. PER AMM 25-32-03, OPS CHECK GOODSDR AALA202603314774Oven · smokeAIRCRAFT WAS NOT GROUNDED: NUMBER 4 OVEN WAS CREATING SMOKE WHEN IN OPERATION. MAINTENANCE REPLACED OVEN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 25-35-19.SDR AALA202603308438Oven · smokeAIRCRAFT WAS NOT GROUNDED: WISPY SMOKE FROM FIRST CLASS OVEN THE LEFT DOOR. VERIFIED FORWARD GALLEY NUMBER 2 INOPERATIVE. (OPEN).SDR CALA2026033014898Oven · inoperative205 FORWARD GALLEY OVEN SMELLS LIKE SMOKE WHEN TURNED ON WE TURN ED IT OFF REQUEST NEF:2510AU. PULLED CB & COULRED. PERFORMED OPS CK, LOT OF SMOKE CAME OUT FROM INSIDE OVEN. NOT ELECTRICAL SMELL FOUND. THE CAUSE WAS THE FOOD ATTACHED TO THE FAN. SEE ATTACHED CSDR DALA2026033002069Oven · smokeTOWARDS THE END OF HEATING UP THE MEALS, I OPENED THE OVEN AND NOTICED SMOKE COMING OUT. THERE WAS NO SMELL WHICH LED ME TO BELIEVE IT WAS FOOD. REPLACED OVEN PERFORMED OPS CHK ALL NML. REF B737 AMM 25-31. OK FOR SVC. (LOG 1511996)SDR DALA2026032702029Coffeemaker · odorELECTRICAL ODOR AT 1R, IMMEDIATELY SHUT OFF FORWARD GALLEY COFFEE MAKER, OVENS, AND CHILLERS. ODOR DECREASED IMMEDIATELY BUT COULD STILL SMELL IT. SHUT OFF CABIN FANS, SELECTED HI FLOW AND AVIONICS EXTRACT TO INCREASE AIRFLOW AND SHUT OFF GALLEY POWER ODOR FINSDR DALA2026032301956Coffeemaker · odorF/A'S SMELLED AN ACRID ODOR IN THE AFT GALLEY-INTERMITTENT AND NOT LOCALIZED-DECREASED/STOPPED WHEN COFFEE MAKERS STOPPED. CORRECTIVE ACTION: FOUND AFT INBOARD COFFEE MAKER C/B TRIPPED AFTER IT OVERFLOWED. REPLACED COFFEE MAKER, INSPECTED HARNESSES & COMPLETEDSDR CALA2026032414803Oven · odorOVEN 205 HAD BAD ODER OF BURNT ELECTRIC. TURNED OFF AND SMELL DISSIPATED. DEBRIEFED FLIGHT CREW AND FLIGHT ATTENDANTS TO CONFIRM SOURCE WAS OVEN 205 IN FWD GALLEY... SMOKE/ODOR FORM 46-6020 ATTACHED IN PHOTO,S... PERFORMED SMOKE/ODOR IN CABIN ECRA 0500-01014SDR CALA2026032314757Oven · fireFAS REPORTED OVEN FIRE, CREW REPORTS ITS GALLEY OVEN 103. REMOVED AND REPLACED OVEN 103 IAW AMM 25-34-00, OPS CHKD GOOD.SDR CALA2026032314735Oven · odorSTRONG ODOR WHEN TRYING TO USE OVEN 2 IN AFT GALLEY. POSSBL ELE CTRIC SMELL. STOPPED USING IT OPS CHECK #2 AFT GALLEY OVEN, OKAY NO SMELL NOTED AT THIS TIME REF AMM 25-34-00.SDR J7SA2026040200477Coffeemaker · odorCOFFEE POT OVER HEATED CAUSING STRONG BURNING SMELL IN FLIGHT. CREW PULLED AND COLLARED HOT JUG 1 AND 2 CIRCUIT BREAKERS. COFFEE POT WAS THEN SECURED IN AFT BAGGAGE AREA. REPLACED COFFEE POT IAW EMB-505 AMM 25-31-02. HOT JUG 1 AND 2 CIRCUIT BREAKERS RESET AIRCSDR AALA202603232001Oven · dirtyAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO PHL DUE TO THE FLIGHT CREW REPORTING THAT WHILE CLIMBING THRU THE UPPER TEENS THE FLIGHT ATTENDANTS REPORTED A SMELL THAT RESEMBLED AN OVEN OR ELECTRICAL SMELL. THE AIRCRAFT LANDED SSDR AALA202603237556Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD GALLEY OVEN HAS PUTRID SMELL. MAINTENANCE REPLACED THE FORWARD GALLEY OVEN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 25-35-19.SDR CALA2026032314734Unknown · odorSTRONG ACRID ODOR WHEN USING AFT GALLEY OVEN NR 2. OPS AFT GALLEY MIDDLE OVEN FOR 10 MINUTES IAW AMM 25-34-00. NO ODORS OR DEFECTS NOTED. OK FOR SERVICE.SDR DALA2026032201927Oven · odorOVEN TURNED OFF, SERVICE MESSAGE SAID MOTOR ISSUE. STRONG BURNT SMELL PRESENT. NO VISIBLE REASON. DUE TO BURNT SMELL FROM OVEN. R/R FWD GALLEY OVEN PER A319 AMM 25-35. RAN OVEN FULL CYCLE. OPS CHECK GOOD. NO SMELL OR FAULT NOTED. PINS/CONNECTOR BEHIND OVEN CHSDR CALA2026032014702Coffeemaker · unlockedCOFFEEMAKER 419 UNLOCKED AND SLIDING OFF RACK FOUND CM419 UNLOCKED AND SLIDING OFF THE RAIL. RESECURED CM419. OPS CK GOOD REF AMM 25-32-01. FLAGGED SDR FOR SAFETY ISSUE.SDR CALA2026032014701Coffeemaker · unlockedCOFFEEMAKER 420 UNLOCKED AND SLIDING OFF RACK FOUND CM420 UNLOCKED AND SLIDING OFF THE RAIL. RESECURED CM420. OPS CK GOOD REF AMM 25-32-01. FLAGGED SDR FOR SAFETY ISSUE.SDR AALA202603270135Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD OVEN NUMBER 2 HAS A STRONG BURNING SMELL, EVEN WHEN NOT IN USE. REMOVED AND REPLACED FORWARD GALLEY OVEN 2. PER AMM 25-32-03. OPS CHECK GOOD.SDR AALA202603190135Oven · odorAIRCRAFT WAS NOT GROUNDED: FORWARD OVEN NUMBER 2 HAS A STRONG BURNING SMELL, EVEN WHEN NOT IN USE. (OPEN).SDR CALA2026032314732Oven · odorAFTER PARKING, OVEN 204 MADE NOISE AND A BURNING ODOR. IT WAS NOT POWERED ON. DEACTIVATED OVEN 204. CREW REPORTS AN ELECTRICAL ODOR FROM FWD GALLEY OVEN 204 BEFORE LANDING.THE OVEN WAS EMPTY AND NOT COOKING ANYTHING. APU WAS ON, HYDRAULICS ON. NO SMOKESDR AALA202603179629Oven · dirtyAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: VERY STRONG ODOR AND FUMES IN COCKPIT AT CRUISE, OCCURED 4 TIMES WAS ISOLATED TO COCKPIT. AIRCRAFT DIVERTED TO AND LANDED SAFELY AT MIA. ACCOMPLISHED SMOKE ODOR FUMES INITIAL T/S PER J/C 08L00021001. FOUSDR CALA2026031714619Oven · shortedDURING CRUISE A FWD GALLEY OVEN SHORTED. ELECTRICAL SMOKE AND AN D FUMES WERE OBSERVED. PLACED OVEN 205 ON NEF CIRCUIT BREAKER PULLED AND COLLARD.SDR SWAA2026031679956Coffeemaker · burnedAFT FA REPORTED BURNING RUBBER SMELL IN AFT GALLEY. ISOLATED ODOR TO AFT GALLEY NR 1 COFFEEMAKER. BURNED PLASTIC ODOR EMANATING FROM REAR SUPPLY TANK OF COFFEEMAKER. REPLACED C/M IAW AMM 25-30-01.SDR F3LA202603160380Water Heater · burned outBURNING ELECTRICAL SMELL FROM FORWARD LAV. AC WAS GROUNDED AS A RESULT OF THIS SDR REPORTABLE EVENT. PERFORMED ISOLATION/DEACTIVATION OF FWD WATER HEATER, SMELL DISSIPATED AFTER TIME PER AMM 05-50-00-510-831-A. LP680661 ITEM #1 PLACED ON MEL 38-10-01B CN 12450SDR SWAA2026031678775Coffeemaker · odorB FA REPORTED A SMOKY ODOR COMING FROM AFT COFFEEMAKER NR 2. R & R AFT NR 2 COFFEEMAKER PER AMM 25-30-01.SDR YENA2026031300299Coffeemaker · odorFLT # 453 BOS-PLS . " DESCENDING THOUGH 6,000 F/A #1 REPORTED STRONG FUEL SMELL IN FWD GALLEY LASTED @ 30 SECONDS THEN DISSIPATED.; C/W INFORMATION NOTICE 20-17-T015 SEC A ISOLATED FAULT TO TYPE 10 ODOR BELIVE TO HAVE COME FROM COFFEE MAKE VENT NO ODOR PRESENSDR CALA2026031014472Coffeemaker · unlockedCOFFEEMAKER 420 FOUND TO BE UNLOCKED AND SLIDING OFF RAIL RESECURED AND LOCKED COFFEEMAKER 420 REF AMM 25-32-01. OPS CK GOOD. FLAGGED SDR FOR SAFETY.SDR CALA2026031014457Oven · failedBURNING ODOR AND LIGHT SMOKE FROM GALLEY OVEN 109, DEBRIEFED WITH CREW, OVEN SMELLED LIKE CIGARETTES WHEN TURNED ON. REPLACED OVEN IAW AMM 25-34-00-020-801-C3. NO HELP, OVEN DOES NOT POWER.SDR SCNA20260309111Oven · smoke803260 & 803262 - AFT GALLEY CENTER OVEN HAD SMOKING COMING FROM AROUND IT - REPAIRED DAMAGED WIRING BETWEEN OVEN CIRCUIT BREAKERS AND P4 CONNECTOR REF SWPM 20-30-12 AND CMM 25-30-117. REACTIVATED G4 GALLEY REF AMM 25-31-41 440-801 OPS CHECK GOOD REF CMM 25-SDR CALA2026031914678Oven · faultedOVEN IN FWD GALLEY HAS STRONG FUMES AND EMITS ABNORMAL NOISE OVEN 203 IN FWD GALLEY MAKING EXTREMELY LOUD NOISE. TRIED RESETTING, NO HELP. R & R STEAM OVEN IN STATION 203 IN FWD GALLEY REF AMM 25-32-02 OPS CHECKED GOOD.SDR CALA2026030614381Oven · odorMID GALLEY OVEN HAD A BURNING ODOR DURING USE. DEBRIEFED CREW AND WAS INFORMED THAT ODOR ONLY OCCURED DURING OVEN USE. OVEN DEACTIVATED AND PLACARDED MID GALLEY OVEN INOP PER NEF 2520P. R & R G21 OVEN IAW AMM 25-34-00-000-801. OPS CHECK OK. NEF REVERSED.SDR CALA2026030514359Coffeemaker · unsecureCOFFEEMAKER 420 FOUND UNLOCKED AND SLIDING OFF RAIL. FOUND COFFEEMAKER 420 UNLOCKED AND UNSECURE. RESECURED THE COFFEEMAKER IAW AMM 25-32-01. OPS CHKD GOOD.SDR CALA2026030514357Coffeemaker · unsecureFOUND COFFEEMAKER TO BE UNLOCKED AND SLIDING OFF RAIL COFFEEMAKER 106 FOUND TO BE UNLOCKED AND UNSECURED. SECURED THE COFFEEMAKER IAW AMM 25-32-01. OPS CHKD GOOD.SDR DALA2026030301437Oven · odorDIVERTED INTO DUB DUE TO FUMES IN THE AFT GALLEY. APPLIED NEF'S ON BOTH AFT GALLEY OVENS. REPLACED NR 1 OVEN AT POS 217 AND OPS CHECKED GOOD. OK FOR SERVICE. (8046959)
Back to JASC 2530