Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026060816878Oven · odorFAS STARTED OVEN NO 204 IT STARTED SMOKING THEY TURNED IT OFF AN D STOPPED USING IT REQUEST NEF FOR FWD GALLEY OVER 204 AS NEEDED PERFORMED SMOKE FUME INSPECTION IN REFERENCE TO 21-00-830 INFROMATION UPDATE PER FIM 21-00 TASK 830 FOUND OVEN NR 204 TO BE SOURCESDR SWAA2026060809206Filter · odorFAS REPORT THE POTABLE WATER HAS A FOUL ODOR. THE TANK WAS EMPTIED AND REFILLED IN DEN. IN CRUISE TO SAN THEY REPORTED THE ODOR OR THE WATER WAS THE SAME OR WORSE. REMOVED AND REPLACED FWD AND AFT COFFEE MAKER FILTERS. OPS AND LEAK CHKD GOOD IAW MM 38-11-04.SDR DALA2026061303558Coffeemaker · odorAFTER PUSHBACK FA SMELLED ROTTEN EGGS. TAXI TO GATE TO TROUBLESHOOT. FOUND COFFEE MAKER NR 3 AS THE ISSUE. CB DID NOT POP AFTER PUSH W/ TWO ENGINE START. AFTER SHUTDOWN AND START R ENGINE AT GATE, CB POPPED AND COFFEE MAKER SMOKING, ROTTEN EGG SMELL CAME BACK.SDR QXEA2026053100130Oven · inoperativeFWD GALLEY OVEN 204 NOT HEATING FOOD. TIMER WORKS. MILD ELECTRICAL ODOR, NEGATIVE SMOKE. ODOR WENT AWAY WHEN OVEN TURNED OFF. CB DID NOT TRIP.REMOVED FROM SERVICE AND PLACED ON DMI. RETURNED TO SERVICE.SDR CALA2026060116665Oven · odorFA REPORTS OVEN 105 PRODUCED SMOKE. TURNED OVEN OFF-NO SMOKE N OTED. FOUND BURNT FOOD RESIDUE IN THE OVEN INSERT, OVEN INSERT REMOVED AND OVEN OPERATED FULL CYCLE (25 MINUTES). NO SMOKE OR ODORS OBSERVED. FORM 46-6020 COMPLETED BY CABIN CREW, TOMC CONTACTED IASDR AALA202606025659Chiller · odorAIRCRAFT WAS NOT GROUNDED: AFT GALLEY CHILLER SMELLS OF ELECTRICAL SMOKE WHEN RUNNING. MAINTENANCE REPLACED CHILLER PER AMM 25-34-51 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR CALA2026060116664Oven · dirtyFA REPORTS AFT GALLEY OVEN 425 HAS BAD SMELL CLEANED GALLEY OVEN 425 REF. AMM 25-34-00. OPS CHECK SAT. SMELLS NORMAL AFTER CLEANING.SDR CALA2026060116716Oven · odorOVEN 707 HAS BURNING ELECTRICAL SMELL. CREW TURNED IT OFF. FORM 46-6020. ATTACHED INSPECTED INSIDE OF OVEN. OVEN CLEAN. NO SPILLS. OVEN SHOWS. NO FAULTS ON SELF TEST REMOVED OVEN AND INSPECTED CONNECTIONS ON OVEN SIDE ALSO AIRFRAME SIDE. NO SIGNS OSDR CALA2026052816605Oven · dentedOVEN/WARMERSMOKING OR SPARKING IN AFT GALLEY OVENS 706 707 708 709 710 711 SMOKE FROM BEHIND OVENS ON DEPARTURE. SHUT OVENS OFF AND PULLED OVEN CIRCUIT BREAKERS. SMOKE APPEARED TO DISSIPATE. TURNED ON OVEN 711 WITH STEAM FUNCTION AND AFTER 15 MINUTES APROX, OSDR AALA202605272826Oven · dirtyAIRCRAFT WAS NOT GROUNDED: NR 2 OVEN HAS BURNING SMELL WHEN TURNED ON. MAINTENANCE SCRUBBED, SANITIZED AND DISINFECTED THE FORWARD GALLY OVEN #2 PER CMM 25-33-01. A SATISFACTORY OPERATIONAL CHECK OF THE OVEN WAS ACCOMPLISHED WITH NO BURNING SMELL DETECTED.SDR CALA2026052716565Structure · damagedFWD GALLEY WALL BY OVEN 205 DISCOLORED. VERIFIED OVEN 205 NOT LEAKING TO THE WALL. REMOVED OVEN FOR RAMS TEAM REF AMM 25-34-00 REMOVED DAMAGED DECO MATERIAL, WALL NOT DAMAGED, INSTALLED NEW DECO MATERIAL REF CMM 25-32-43. REINSTALLED FWD GALLEY OVEN 205 REF SDR CALA2026052616524Oven · faultedOVEN SMOKING OR SPARKING DR-1 CTR GAL ALL OVENS SMOKING WHEN ON. ALL OVENS TURNED OFF NO MORE SMOKE CREW FILLED OUT FORM 46.6020. AFFECTED AREA NOTIFIED BY CREW TO BE DR-4 OVEN 705. SUSPECTED SMOKE AND ODOR FROM FOOD LIQUIDS. BURN SMELLS REPORTED BY CREW. ON CSDR DALA2026052103120Coffeemaker · odorFWD FA SMELLED A DIRTY SOCKS SMELL AFTER TAKEOFF. SMELL DISSIPATED AFTER 5 MINS AND DID NOT RETURN. NO ABNORMAL ODORS IN THE FLIGHT DECK OR AFT GALLEY. REPLACED FORWARD COFFEEMAKER. (LP 8939196, 8939198 - AIRCRAFT WAS GROUNDED)SDR CALA2026060316799Coffeemaker · leakingGALLEY COFFEEMAKER LEAKS. COFFEEMAKER BAG BROKE OPEN SO NOW HS GROUNDS IN IT AND SMELLS FUNNY WHEN HEATING UP FWD GALLEY COFFEEMAKER INOP LEAKS IN USE CLEANED EXCESS GROUNDS AND AREA. PLACE ON NEF 2522AK BREAKER COLLARED AND PLACARD IN PLACE. APPROVED FOR NESDR DXTA2026051908121Coffeemaker · faultyFA NOTICED WISPY SMOKE FROM COFFEE MAKER. FO GOT UP TO LOOK AND SMOKE WAS ALREADY GONE, WITH NO SMELL NOTICED. IT LASTED MAYBE 20-30 SECONDS. COFFEE MAKER WAS TURNED OFF AND FLIGHT CONTINUED UNEVENTFULLY. CORRECTIVE ACTION: REMOVED FAULTY GALLEY COFFEE MAKER PSDR AALA202605207235Oven · burned outAIRCRAFT WAS GROUNDED: PLASTIC BURNING ODOR THROUGHOUT THE CABIN. STRONGER ODOR TOWARDS THE FRONT OF THE AIRCRAFT. PERFORMED 09L00021001 AND FOUND NUMBER 1 OVEN HAS EVIDENCE OF BURNING PLASTIC. REMOVE AND REPLACED NUMBER 1 OVEN. PER AMM 25-35-03. GROUND OPS CHSDR DALA2026051903075Oven · odorFA SMELLED ELEC ODOR FROM FWD GALLEY OVEN. TURNED OFF OVEN AND ODOR CLEARED. C/A: VERIFIED THAT ODOR COMES FROM CLEANNG SOLUTION AFTER TURNING ON THE OVEN. CLEANED AND DRIED OUT THE SMELLING CLEANING SOLUTIONS THRO-OUT THE OVEN. RUN OVEN AT HIGH TEMP FOR 30 MISDR SCNA20260515200Oven · dirtyAFT OVEN RACK TO SMALL SMOKEY AND NEEDS CLEANING. INFORMED CATERING FOR NEW OVEN INSERTS AND RACKSSDR DALA2026052203122Oven · odorSHIP 3161 DISC: OVEN -INCLUDES OVEN TIMERS DAMAGED. WHEN ON AND IN USE, THE OVEN HAS A STRONG BURNT PLASTIC SMELL. THE SMELL FILLS UP THE GALLEY. I DO NOW THINK THIS OVEN SHOULD BE USED AGAIN BEFORE IT'S FIXED. C/A: DISCUSSION SMELL WITH F/A AND CAPT. RAN OVENSDR CALA2026051416223Oven · dirtyGALLEY OVEN DIRTY, NEEDS CLEANING AT FWD G1A GALLEY OVEN 103 OVEN 103 HAS CAKED ON FOOD. PLACARDED AND COLLARED. CREW ADVISED ADDING PICS. FOOD CAKED TO BOTTEM REQUIRES DEEP CLEANING OR REPLACEMENT FWD GALLEY OVEN HAS HARDNED COOKED FOOD ON THE BOTTOM PLACING SDR CALA2026051316207Oven · faultedOVEN 205 SMOKES WHEN OPERATED FOR 5 MINS UP OF ISSUE R EF LOGBOOK REQUESTING MEL 2500BI FOR OVEN 205. DDP C/W. PURSER STATED; DURING SMOKE EVENT, ROW 1 LEFT AND ROW 2 LEFT POWER OUTLETS LOST POWER. COMPLETED SMOKE FORM ATTACHED. ROW 1 LEFT AND ROW 2 LEFT POWSDR CALA2026051416222Oven · odorOVEN 605 SMOKEY SMELL NOT USED TOMC APPROVAL REQUIRED, APPROVED OVEN 605 DEFERRED PER NEF 2500BR, M-PROCEDURE PERFORMED, PLACARD INSTALLED. CLEANNED OVEN 605, OPS CHECK NO SMOKEY SMELL ANYMORE REF AMM DMC-B787-A-25-32-00-12A-999A-A REMOVED NEF NO OTHER ISSUES SDR AALA202605061871Coffeemaker · odorAIRCRAFT WAS NOT GROUNDED: BOTH AFT COFFEE MAKERS PRODUCING CHEMICAL SMELL. REMOVED AND REPLACED BOTH AFT COFFEE MACHINE IN AFT GALLEY. OPS AND LEAK CHECK GOOD. PER AMM 25-32-00.SDR QXEA2026050600103Oven · odorFLIGHT 2276. FWD GALLEY OVEN SMELLS LIKE BURNT CIGARETTES. REMOVED FROM SERVICE. INVESTIGATED FWD CALLEY OVENS, COULD NOT SMELL ANYTHING. RAN APU AND PACKS AND COULD NOT REPLICATE THE SMELL DURING THAT TIME. NO HISTORY LAST 30 DAYS. COULD NOT DUPLICATE. RETURSDR CALA2026050515980Oven · odorOVEN SMELLS BAD G2 GALLEY OVEN 205 INSPECTED OVEN 205 AND OPS CHECK, VERIFIED WITH CREW MO UNUSUAL SMELLS PRESENT. OK FOR SERVICE.SDR CALA2026050716047Oven · odorFWD GALLEY OVEN NUM 2 EMITS STRONG BAD SMELL WHEN HEATED SMELL CONFIRMED WHEN TURNED ON. CB PULLED AND TAG APPLIED. REQUEST MEL FOR FWD #2 GALLEY OVEN INOP. C/W DDP. NOC TOMC APPROVED IAW NEF 2500BI PLACED FWD GALLEY OVEN %2 ON MEL. OVEN RECEIVED WAS DAMAGED. SDR DALA2026050402811Oven · smokeSMOKE FROM FORWARD GALLEY OVEN WHEN HEATING MEALS. OVEN DEFERRED TO NEF. SUBSEQUENTLY REPLACED FWD GALLEY OVEN. (8671756) AIRCRAFT WAS GROUNDEDSDR AALA202604293577Oven · burned outAIRCRAFT WAS GROUNDED: DESCENDING THROUGH 12000 A BURNING PLASTIC SMELL STARTED ON THE FLIGHT DECK. LEVELING AT 10000 FEET THE SMELL WAS IN THE CABIN AND REPORTED BY THE FLIGHT ATTENDANTS. TROUBLESHOT SMOKE ODOR FUMES, PER W/C 08L00021001. FOUND OVENS AS SOURCSDR SCNA20260428174Coffeemaker · odorELECTRICAL BURNING SMELL COMING FROM OVEN OR COFFEE MAKER. REMOVED AND REAPLCED AFT OVEN REF AMM 25-31-01 OPS CHECK NORMAL THIS CLEARS MEL.SDR CALA2026043015861Rail · brokenLVL 2 DUE TO HISTORY OF FWD GALLEY COFFEEMAKER (M11) INOP. REF. L/PS 8694821, 8683565, 86548211. ACP TSM 25-35-00-810-802-A AND CORRECT FAULTS. VERIFY CM M11 (7055MM) GRDS 9007VN & 9008VN REF. AWM'S 25-31-01, 25-31-02 ARE GOOD. UPDATE LOG WITH FINDINGS AND ALLSDR AALA202604283658Oven · smokeAIRCRAFT WAS NOT GROUNDED: WHEN FACING OVENS, OVEN ON THE RIGHT SIDE SMOKES WENT TURNED ON. REMOVED AND REPLACED RIGHT HAND FORWARD OVEN. PER AMM 25-32-03. OPS CHECK GOOD.SDR CALA2026042815767Oven · odorNUMBER 2 FWD OVEN PRODUC ED SMOKE DURING USE DEBRIEFED CREW AND THEY STATED THAT THE FWD GALLEY OVEN #2 STARTED TO PRODUCE SOME SMOKE SHORTLY AFTER BEING TURNED ON WITH A FOOD ODOR. SMOKE WAS COMING FROM AROUND THE OVEN DOOR SEAL. THEY SHUT OVEN AND SMOKE STOPSDR CALA2026042915852Oven · smokeCREW REPORTED OVEN 205 BEGAN TO SMOKE IN FLIGHT AND FLIGHT ATTENDANTS NOTED FLAMES CONTAINED TO IN INSIDE OF THE OVEN. EXTINGUISHED WITH HALON FIRE EXTINGUISHER.SDR CALA2026042815755Coffeemaker · odorBURNING ODOR BY COFFEE MAKER 103. PERFORMED CONDITIONAL INSPECTION FOR CABIN EQUIPMENT FWD GALLEY REF FIM 21-00 TASK 830 DID NOT NOTE FOUL SMELL OR ANY SMOKE, FOUND RESIDUAL COFFEE FROM COFFEE MAKER 105, DEFERRED REF NEF 2500BD MX ACTION ACCOMPLISHED INOP PLASDR CALA2026042715732Oven · failedFORWARD GALLEY OVEN 109 ODOR POSSIBLY ELECTRICAL. PRECAUTIONARY C-B PULLED OPEN GALLEY OVEN 109. GALLEY OVEN REPLACED IAW AMM 25-31-00SDR DALA2026042302611Galley · odorDIV - TO CVG DUE TO STRONG PLASTIC SMELL IN AFT GALLEY. FOUND PLASTIC BAG IN CONTACT WITH COFFEE POT. PERFORMED ALL POST SMOKE AND FUME WORKCARDS. (LP# 8948100; AIRCRAFT WAS GROUNDED)SDR CALA2026042215600Oven · odorOVEN 205 BEGAN TO SMOKE BEFORE COOKING FA PULLED BREAKER TO STOP THE SMOKE. OPERATED OVEN FOR 20 MINUTES, NO EVIDENCE OF SMOKE OR ODOR, INSPECTED SURROUNDINGS, NO DEFECTS NOTED.. PLACED OVEN ON NEF 2510AU PRECAUTIONARY. CREW OBSWERVED APPARENT SMOKE COMING FSDR DALA2026042102519Coffeemaker · smokeCOFFEE MAKER DAMAGED / INOPERATIVE / LOCATIONS:400. COFFEE MAKER IS DIFFICULT TO PRESS DOWN, WHEN TURNED ON IT BEGAN TO SMOKE. R/R COFFEE MAKER F103 REF B737 AMM 25-31. INSPECTED ALL WIRING BEHIND COFFEE MAKER. CHECKS OK. (LOG 1550336 - AIRCRAFT WAS GROUNDED).SDR CALA2026042015514Oven · odorOVEN 205 HAD STRONG BURNING ODOR COMING FROM IT. STOPPED USING. CHECKED OUT NO ODOR NOTED, PULLED BREAKER. OVEN 205, WAS OFF AND THERE WAS NO ODOR NOTED. R & R G22/205 OVEN IAW AMM 25-32-03, OPS CHECK GOOD, NO ODOR NOTICED.SDR CALA2026042115571Oven · fireOVEN NR 1, SMOKING DURING FLIGHT. FAS INFORMED CREW, SMELLED LIKE FIRE BURNED FOOD CONTAINED WITHIN OVEN RACK . REMOVED AND REPLACED NR 1 OVEN IAW AMM 25-34-00-000-801-C3. PERFORMED AREA CLEANING IAW 25-31-05-167-002.SDR CALA2026042015486Oven · dirtySMOKE COMING OUT OF OVEN INTO CABIN, CREW DECLARING EMG AND AIR RETURNING TO EWR. RAN OVEN FOR 15 MINS NOT NOTICIABLE BURNING ODOR DETECTED, NOTE BURNING ODOR WAS COMMING FROM OVERSPILLED CARAMEL BEEN BURN INSIDE OVEN, FOUND NO EVIDENCE OF ELECTRICAL BURNINGSDR AALA202604172109Oven · fireAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT DIVERTED TO TUS DUE TO THE FLIGHT CREW REPORTING THAT WHILE INFLIGHT, THE FLIGHT, FLIGHT ATTENDANT REPORTED THERE WAS A FIRE IN THE FORWARD GALLEY OVEN. THE AIRCRAFT LANDED SAFELY AT TUS AND TAXSDR CALA2026041415363Oven · odorOVEN 204 SMELLED LIKE BURNING RUBBER WITH SMOKE. BOTH STOPPED ONCE POWER WAS REMOVED REQUEST DEFERRAL APPLIED NEF 2510AU. DDP COMPLIED WITH. REF LP 8544978 FOR CONDITIONAL INSP PERFORMED FOR SMOKE. REMOVED AND REPLACED OVEN 204 IN REF TO AMM 25-34-00. OPS CHECSDR CALA2026041415367Oven · smokePILOT REPORTED SMOKE IN OVEN DURING REF LP8522149 FOUND OIL IN OVEN CAUSING SMOKE. APPLYING NEF 2510AU SEE PICS FOR SMOKE REPORT OVEN IN QUESTION LOCATED 204. REMOVED AND REPLACED OVEN IAW AMM 25-34-00, OPS CHKD GOOD.SDR AALA202604146222Warmer · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS IN AFT GALLEY REPORTING BURNING SMELL COMING FROM GALLEY VENTS DURING DESCENT AND TAXI. MAINTENANCE ACCOMPLISHED THE SMOKE / ODOR / FUME INSPECTION, FOUND BURNT COFFEE IN POTS AND MELTED PLASTIC WATER BOTTLE CAP ON SDR AALA202604140942Coffeemaker · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS IN AFT GALLEY REPORTING BURNING SMELL COMING FROM GALLEY VENTS DURING DESCENT AND TAXI. MAINTENANCE ACCOMPLISHED THE SMOKE / ODOR / FUME INSPECTION, FOUND BURNT COFFEE IN POTS AND MELTED PLASTIC WATER BOTTLE CAP ON SDR AALA202604147322Coffeemaker · odorAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS IN AFT GALLEY REPORTING BURNING SMELL COMING FROM GALLEY VENTS DURING DESCENT AND TAXI. MAINTENANCE ACCOMPLISHED THE SMOKE / ODOR / FUME INSPECTION, FOUND BURNT COFFEE IN POTS AND MELTED PLASTIC WATER BOTTLE CAP ON SDR CALA2026041315323Oven · smokeSMOKE COMING OUT OF OVEN IN FWD GALLEY AFTER TAKEOFF PERFORMED FIM TASK 21-00 TASK 830. SMOKE IN CABIN INSPECTION COMPLETED.FOUND GREASE FROM CUBAN PORK RIBS LEAKED ALL OVER THE FOOD AND OVEN. REMOVED FOOD. CLEANED OVEN. OVEN NEEDS TO BE REPLACED OR CLEANED. PSDR CALA2026041715429Oven · dirtyOVEN 205 FA SHUT OFF DUE BURNING SMELL PERFORMED AMM 05-51-58 REV 139. FOUND FOOD SPILLAGE IN OVEN 205 FWD GALLEY. COMPLIED WITH, CB PULLED AND COLLARED. OVEN 205 DEFERRED IAW NEF 2520P. CLEANED LARGE BURNT FOOD FROM BOTTOM OF OVEN. STILL SMELLS DURING OPS SDR SWAA2026040987838Coffeemaker · smokeFA REPORTS SMOKE SMELL IN AFT GALLEY DURING APPROACH/DECENT. SMELL DISIPATED AFTER COFFEE MAKER SHUT OFF. NO ABNORMAL INDICATIONS IN FLT DECK.<[01] PERFORMED CONDITIONAL INSP 05-51-56; FOUND AFT #1 COFFEE MAKER HOT PLATE AS SOURCE OF SMELL. R&R #1 AFT COFFEE M
Back to JASC 2530