SDR 2008UALA05493Coffeemaker · smokeAFT GALLEY SMOKE APPEARING. OCCURRED JUST PRIOR TO LANDING AND ELECTRICAL POWER REMOVED FROM GALLEY AS A PRECAUTION. PER FLIGHT ATTENDENTS, THEY SAW A SMALL AMOUNT OF SMOKE COMING FROM AREA NEAR AFT LEFT COFFEE WARMER. OPERATED ALL AFT GALLEY EQUIPMENT. CHECSDR USAA920081567Coffeemaker · brokenFLT 1062 ABE CLT BURNING ODOR FORWARD COFFEEMAKER HAD ELECTRICAL ODOR. TURNED OFF AND PULLED CIRCUIT BREAKER. NO FURTHER PROBLEMS NOTICED.SDR AALA200802163Oven · dirtySTL INFLIGHT T1419/22AUG. FIRST CLASS GALLEY OVEN SMOKING AFTER TAKE OFF. RETURNED TO STL AND LANDED WITHOUT INCIDENT. FOUND RESIDUE IN OVEN. REPLACED FIRST CLASS GALLEY OVEN AND OVEN CONTROLLER. SYSTEM GROUND CHECKED NORMAL OPS.SDR N93A17082008Oven · odorOVEN PRODUCED SMOKE. FLIGHT ATTENDANT PULLED CIRCUIT BREAKER. SMOKE DISSIPATED (FOOD BURNT ODOR). OVEN REPLACED AS PRECAUTION. SUSPECT BURNT FOOD. (S)SDR USAA920081516Chiller · faultyFLT 1177-LGA-CLT- BURNING ODOR - FORWARD CHILLER HAS A BURNING ODOR. TURNED CHILLER OFF AND ODOR DISSIPATED. MAINTENANCE REMOVED AND REPLACED FORWARD CHILLER. OPERATIONAL CHECK WAS GOOD. (S)SDR USAA920081508Coffeemaker · smokeFLT 981, SMOKE CAME OUT FWD COFFEEMAKER WHEN TURNED ON. R & R FORWARD COFFEEMAKER. OPS CHECK WAS GOOD.SDR 2008FA0000522Pan · misinstalledCABIN SMOKE DUE TO DRIP PAN IN OVEN BEING IMPROPERLY INSTALLED CAUSING DRIPPINGS FROM FOOD TO CONTACT OVEN LOWER BURNER ELEMENTS. (K)SDR QXEA200800858Coffeemaker · malfunctionedPDX - FLIGHT 2335. CREW REPORTED A BURNING ODOR IN THE AFT GALLEY AREA. MAINTENANCE FOUND THE SOURCE TO BE THE LT JUG. REPLACED THE LT JUG. OPERATIONAL CHECKS GOOD. ACFT RETURNED TO SERVICE. (S)SDR AALA200801925Chiller · inoperativeDEN INFLIGHT T073/22JUL ORD TO HNL. CREW REPORT SMOKE AND FUMES IN CABIN AT LT NR FOUR LAVATORY. CREW WAS ABLE TO CLEAR SMOKE. LANDED DEN WITHOUT INCIDENT. FOUND RT HAND AFT CHILLER CIRCUIT BREAKER POPPED AND HOT. REPLACED RT HAND AFT CHILLER. SYSTEM GROSDR USAA920081394Coffeemaker · defectiveFLT 350 PHX-LAX - BURNING SMELL - COFFEEMAKER WILL NOT BREW. COFFEEMAKER WENT OFF AND THERE WAS A SMELL OF WIRE BURNING. NO SMOKE WAS DETECTED. MAINTENANCE REMOVED AND REPLACED THE COFFEEMAKER. OPERATIONAL CHECK WAS GOOD. (A)SDR CA080728004Oven · dirty(CAN) FLIGHT RETURNED TO THE STATION DUE TO CABIN SMOKE FROM FWD OVEN (DARK SMOKE). CABIN DETECTOR ACTIVATED. BOTH FWD OVENS INSPECTED AND ELECTRICAL CONNECTION CHECKED AND FOUND SERVICEABLE. LT OVEN INSERTS FOUND DIRTY (FOOD RESIDUE). OVEN REPLACED AND SERVICSDR DXTA200803149Microwave Oven · defectiveMICROWAVE CAUGHT FIRE INTERNALLY DURING USE IN FLIGHT, FIRE SMOOTHERED AND MICROWAVE CB PULLED. DEFERRED IAW AC EASY MEL. ACCOMPLISHED MAINT PROCEDURE, PULLED AND COLLARED MICROWAVE CB IN GALLEY. REMOVED DEFECTIVE MICROWAVE P/N 400-1338-O4L S/N 00-5-26863 ANDSDR YEN2008F00009Coffeemaker · odorIN CRUISE, HAD ELECTRICAL FUMES IN FAT GALLEY APPROX 5 MIN, IT DISSIPATED C/W TSM 23-39-00-810-801. NO FAULTS FOUND AND NO DAMAGE NOTED DUE TO LTV SYS, OPS TEST NORMAL AT THIS TIME. ACCOMPLISHED TSM TASK 24-00-00-810-823. ELECTRICAL BURNING ODOR OR FUMES INSDR HNA2008F00024Coffeemaker · burnedHOT JUG IN WARMER NR 1 HAS BURNING SMELL. REPLACED HOT JUG. FOUND ONE BURNED PIN IN OLD JUG. (K)-SDR WRLA2008053Coffeemaker · odorAFT GALLEY COFFEEMAKER 5 OR 8 HAS STRONG ELECTRICAL SMELL. BOTH SHUT OFF IN FLIGHT. FOUND COFFEEMAKER NR 8 POPPED. NR 5 COFFEEMAKER OPS CHECK OK PER MM 25-32-15. CHECKED OPERATION, OPERATES NORMAL NEF ITEM N25JU1808-721 CLEARED. (S)SDR 2008UALA03357Chiller · trippedSMOKE POSSIBLY ELECTRICAL IN BUSINESS GALLEY IN FLT. ALL POWER TO GALLEY SECURED. *S/D* FOUND CHILLER CIRCUIT BREAKER TRIPPED. REPLACED MID FWD GALLEY CHILLER, OP CHECK GOOD. AC OK FOR SERVICE.SDR HNAA0800208Receptacle · burnedWARMER NR 1 SOCKET ON AIRCRAFT LOOKS DAMAGED AND DOES NOT WORK. WARMER NR 2 OPERATES NORMALLY. WARMER NR 2 HAS SMOKE ODOR WHEN SELECTED ON. INSPECTED FOR DAMAGE FOUND BOTH AIRCRAFT SOCKETS TO BE DAMAGED DURING HIDDEN DAMAGE INSPECTION, REF LOG BOOK PG 26925SDR C2XA08IA137Coffeemaker · burnedIAH - FLIGHT 2504, THE CREW REPORTED A BURNING SMELL IN FRONT OF CABIN. MAINTENANCE INSPECTED THE ACFT AND FOUND THE NR1 COFFEE BREWER TO BE BURNED UP. MAINTENANCE REMOVED AND REPLACED THE COFFEE BREWER. OPERATIONALLY CHECKED WITH NO DEFECTS, AND THE ACFT WSDR C2XA08IA133Coffeemaker · odorJAN - FLIGHT 2461 DURING TAXI THE CREW REPORTED AN ELECTRIC SMELL IN GALLEY AREA. CONTRACT MAINTENANCE, "FOUND COFFEE MAKER NR 1 MAKING SMELL PLACED ON NEF-6L01 CAT D CONTROL NR 146579", AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. THE AIRCRAFT LANDESDR SWAA082857Coffeemaker · faultyDECLARED EMERGENCY - FLIGHT CREW REPORTED BURNING SMELL AT FL 190. INSPECTED AIRCRAFT FOUND FWD COFFEEMAKER HOT AFTER BEING SHUTDOWN OVER HALF AN HOUR. REMOVED AND REPLACED COFFEEMAKER PER MM.SDR SWAA082720Coffeemaker · faultySMOKE DETECTED INFLIGHT FROM FWD COFFEEMAKER. SMOKE DISSIPATED AFTER GALLEY POWER SHUT OFF. FOUND COFFEEMAKER WIRES SHORTED. REMOVED AND REPLACED COFFEEMAKER PER MM.SDR WRLA2008049Chiller · malfunctionedKDFW/KATL: FORWARD CHILLER POPS C/B IN FLIGHT WITH ASSOCIATED ODOR OF ELECTRICAL SMOKE. REMOVED AND REPLACED FWD GALLEY CHILLER, OPS CHECK SATISFACTORY PER MD-11 25-37-82. (A)SDR F3LA200800275Coffeemaker · odorREFERENCE LOG PAGES 369125 AND 369126. DURING FLIGHT THE FA REPORTED A STRONG ODOR AND HEAT. MAINT RAN APU AND ENGINE (1) AND (2) AT IDLE WITH BOTH PACKS ON. MAINT VISUALLY INSPECTED CARGO PITS, FWD AVIONICS COMPARTMENTS AND FUSELAGE, AFT OF PRESSURE BULKHEADSDR 2008UALA02893Motor · faultyCART LIFT INOP WITH ACRID ELECTRICAL ODOR. NOTE CHRONIC HISTORY. MOTOR AND LIMIT SWITCH TO BE FAULTY. REPLACED SWITCH S10 OPS NORMAL PER MM 25-38-00. REPLACED MOTOR PER 25-38-02 OPS NORMAL. ACFT OK FOR SERVICE.SDR C2XA08RI074Coffeemaker · malfunctionedFLIGHT 2404 - EWR - FLIGHT CREW REPORTED COFFEEMAKERS EMITTING BURNING SMELL WHEN TURNED ON. EWR MX PERFORMED OPERATIONAL CHECK OF BOTH COFFEEMAKERS IAW EMB 145 VCMM 25-30-39 SUCCESSFULLY AND COULD NOT DUPLICATE BURNING SMELL. NO ABNORMALITIES WERE FOUND. ASDR DL777080725Oven · defectiveELEC SMELL IN MID GALLEY NR 1 OVEN SHUTDOWN TURNED OFF SMELL DISSIPATED. REMOVED NR 1 OVEN AND INSP WIRING BEHIND OVEN AND OVEN ELEC CONNECTOR. NO TROUBLE FOUND. REMOVED AND STOWED OVEN ELEC CONNECTOR. PULLED AND COLLARD OVEN NR 1 C/BS FWD TO NEF USING FRCSDR NWAA082093313Oven · smokeAFTER TAKEOFF, SMOKE STARTED COMING OUT OF THE OVEN. LANDING WAS UNEVENTFUL AND OVEN WAS REPLACED.SDR 2008UALA02628Oven · malfunctionedFWD GALLEY OVEN 106 R12 COOKED VERY SLOWLY THEN GOT SO HOT IT BURNED PLASTIC CASING ON OUTSIDE. REPLACED OVEN.SDR 2008UALA02620Control Unit · failedLOST AFT GALLEY POWER ON CLIMB-OUT. THIS ISSUE WAS VERY DIFFICULT TO DIAGNOSE AND REQUIRED THREE WEEKS OF CONSTANT TROUBLESHOOTING. AFTER ALL WIRES WERE HAND OVER HAND CHECKED AND FOUND NORMAL, K1 AND K2 RELAYS WERE CHANGED, BUSS TIE BREAKERS WERE ALSO CHANGSDR HALA0800556Oven · fireFA REPORTED FIRE AROUND OVENS NR 1 AND NR 2 FWD GALLEY. REMOVED AND REPLACED OVENS NR 1 AND NR 2 IN FWD GALLEY VISUALLY INSP GALLEY CAVITIES OF FWD GALLEY FOR NR 1 AND NR 2 OVEN. NO RESIDUAL OF SMOKE NOTED. OPS CK OK IAW TR767 AMM 25-001.SDR AALA200801176Oven · dirtySTL INFLIGHT T311/274 - FLIGHT ATTENDANT REPORTED ELECTRICAL SMELL AND SMOKE EVIDENCE. TURNED OFF GALLEY POWER AND CABIN LIGHTS. SMOKE WAS LOCALIZED TO FORWARD GALLEY AND FORWARD SECTION OF FIRST CLASS. SMOKE DISSIPATED DURING APPROACH. RETURNED TO STL ANSDR MASA200800371Angle · corrodedFOUND CORROSION DAMAGE ON LOWER SHELF ANGLES LOCATED INSIDE GALLERY. REPLACED ANGLES 3 EACH.SDR DL76L080645Coffeemaker · shortedREAR COFFEEMAKER ON RIGHT SIDE EMITTED SPARK AND SMOKE WHEN ACTIVATED. SMOKE DISSIPATED SHORTLY AFTER. PULLED REAR COFFEEMAKER AS PER INSTRUCTIONS FROM ATL MTC. THERE WAS A SHORT CIRCUIT BECAUSE OF WATER. CB TRIP RESET A BREWED OK. PLS OBSERVE NEXT FLIGHTSDR 2008UALA02471Relay · faultedGALLEY 415 ALL ELECTRICAL PANELS VERY HOT 1HR INTO FLT. SECURED GALLEY EMERGENCY POWER SWITCH PANELS COLD. FOUND FAULTY CHILLER RELAY. REPLACED RELAY OP CHECKED GOOD. AC OK FOR SERVICE.SDR NWAA081643133Coffeemaker · odorDURING CLIMB-OUT, STRONG BURNING SMELL IN FLIGHT DECK AND CABIN. FLIGHT ATTENDANT FOUND THAT 1ST CLASS GALLEY COFFEEMAKER WAS OVERHEATING AND NOT TURNING OFF WITH SWITCH. COFFEEMAKER CB PULLED FOR REMAINDER OF FLIGHT. REPLACED COFFEEMAKER.SDR 2008UALA02179Wire · arcedSMOKE AND ARC'S IN FWD GALLEY PER CREW. FOUND WIRE ON TOP OF COFFEE MAKER M10 THAT HAD BEEN GROUNDED AND ARCING. REPLACED COFFEE MAKER M10-ALL OPS WERE GOOD
SDR NWAA081563162Coffeemaker · smokeFIRST CLASS COFFEEMAKER MADE A LOUD POP WITH SMOKE, LANDING UNEVENTFUL. FOUND COFFEEMAKER BOTTOM DAMAGED AND CIRCUIT BREAKER ON BACK OF COFFEEMAKER POPPED. REPLACED COFFEEMAKER AND CHECKS OK.SDR DL76S080574Coffeemaker · inoperativeAFT GALLEY NR 4 COFFEEMAKER INOP. HEATING ELEMENT FOR POT WARMER BROKEN CAUSING IT TO SMOKE. REMOVED AND REPLACED COFFEEMAKER.SDR 2008UALA02009Coffeemaker · shortedFLIGHT DIVERTED DUE TO ELECTRICAL/BURNING ODOR AND SMOKE IN AFT GALLEY. COFFEEMAKER WIRING TO TANK CONNECTION DAMAGED. REPLACED COFFEEMAKER.
SDR WRLA2008043Oven · malfunctionedEDDP/KBGR OVEN 609 AFT GALLEY ON FOR 5 MIN. THEN GRAY AND WHITE SMOKE BILLOWED OUT, SHUT OFF OVEN. ITEM PLACED ON DMI PER MEL 25-29-01 CAT C DUE 04/17/08. REMOVED AND REPLACED OVEN 609, DMI CLEARED 04/10/08.SDR 2008UALA01984Coffeemaker · faultyFA SHOCKED WHEN GRABBING BOTH HANDLES OF THE COFFEE POTS AT 2R. REPLACED M51 & M52 COFFEE MAKER - OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA01773Oven · odorRTFL DUE TO CREW REPORTS OF A STRONG ELECTRICAL ODOR IN AFT GALLEY. FOUND NO ODORS FROM AIR CON SYSTEM. FOUND STRONG ELECTRICAL ODOR EMITTING FROM R42 OVEN. INTERNAL SHORTING IN OVEN. REPLACED R42 OVEN, NO ODOR NOTED.
SDR AALA200800744Oven · dirtyEWR INFLIGHT T1905/29MAR - DURING CLIMB FLIGHT ATTENDANT REPORTED OUTBOARD GALLEY OVEN SMOKING AND OVERHEATING. RETURNED TO EWR AND LANDED WITHOUT INCIDENT. FOUND PLASTIC WRAP MELTED ON RACK IN OVEN. REMOVED OVEN RACK AND COLLARED CIRCUIT BREAKER AND PLACARSDR HALA0800465Galley · corrodedMID GALLEY COMPARTMENT M106 LT O/B PARTITION SHOWS SIGNS OF CORROSION BETWEEN PLATES ADJACENT TO BENCH TOP. REPAIRED IAW SRM 51-10-01.SDR DL76G080325Oven · sparksAFT GALLEY OVEN NR 3 HAD SPARKS ON TOP WHEN TURNED ON, PULLED C/B. PULLED OVEN AND INSPECTED OVEN AND AREA FOR EVIDENCE OF ELECTRICAL OR MECHANICAL DEFECT. NO TROUBLE FOUND. REACTIVATED OVER AND PERFORMED OP CK, NO DEFECT NOTED. AS PRECAUTION REPLACED OVENSDR SWAA081260Coffeemaker · leakingAIR TURNBACK. AFT GALLEY SMOKE, STEAM, DRAINING WATER. FOUND AFT NR 2 COFFEEMAKER LEAKING. REMOVED AND REPLACED COFFEEMAKER PER MM.SDR MWEA080038Oven · dirtySMOKE STARTED COMING OUT OF THE NR 2 OVEN. FOUND FOOD IN BACK OF OVEN CAUSING THE SMOKE. CLEANED FOOD OFF OVEN AND SWAPPED OVEN CONTROL MODULES FROM NR 1 TO NR 2 OVEN TIMER KNOB, NOW CHECKED GOOD.SDR NWAA080736302Oven · contaminatedAFTER TAKEOFF, NR 2 MAIN TANK FORWARD PUMP MESSAGE AND LIGHT CAME ON, FOLLOWED BY RIGHT UTILITY BUSS LIGHT AND MESSAGE. PERFORMED FUEL PUMP PROCEDURE AS PER COM FIRST AND COMPLIED. THEN PERFORMED RIGHT UTILITY PROCEDURE AS PER COM AND COORDINATED WITH PURSERSDR NWAA080716304Oven · fireFLIGHT ATTENDANT REPORTED A SMALL PIECE OF TAPE WAS STUCK IN THE OVEN AT DOOR 4 OVEN BELOW UNIT 3-57, AND HALON BOTTLE AT 4L WAS USED, BECAUSE OF A SMALL FIRE DID ERUPT. MAINTENANCE CONFIRMED SOURCE OF SMOKE WAS CATERING TAG/TAPE. REMOVED AND REPLACED OVEN, SDR NWAA080726311Oven · smokeDURING FLIGHT, FLIGHT ATTENDANT REPORTED THAT OVEN NR 1, IN GALLEY NR 2 HAD SMOKE COMING FROM UPPER RT OF SEAL. FIRE EXTINGUISHER WAS USED (REFERENCE LOG PAGE 2810194). FLIGHT CONTINUED ON, AND LANDING WAS UNEVENTFUL. MAINTENANCE FOUND OVEN CONTROL C/B POPP