JASC 2597
Service difficulty reports · 798
Reports filed under 2597 · Equipment/Furnishings Wiring, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2597' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2597' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA111028006Electrical Box · inoperative(CAN) PILOT REPORTED WHILE DOING PRE-FLIGHT CHECKS ALL AVIONICS UNSERVICEABLE, EXCEPT FOR UNS GPS, AND INTERPHONE. NO RADIOS. FOUND REU TO BE AT FAULT AND ODOR COMING FROM IT. REPLACED REU, SYSTEMS CHECKED SERVICEABLE AND ACFT RETURNED TO SERVICE. REU TO BSDR UALA2011102005684Connector · damagedLEFT SLIDE BOTTLE PRESS WILL NOT TEST. BOTTLE PRESSURE VERIFIED. READS 2725. FOUND PRESSURE SWITCH ON BOTTLE TO BE OPEN. CONDUCTED TROUBLESHOOTING OF LEFT INFLATION BOTTLE PRESSURE TEST LIGHT. FOUND CONNECTOR D5530 LEFT SLIDE BOTTLE PRESSURE, INTERMITTENT, SDR YENA20111018365Connector · looseFLT 534 TPA-EWR - DURING MAINTENANCE, ON WEEKLY CHECK FOUND EMERGENCY LIGHT TEST FAULT. EPSU EXT LOAD AFT LEFT. RE-SECURED L2 SLIDE CONNECTOR AMM 25-62-44. EMERGENCY LIGHT TEST GOOD.SDR UALA2011101305558Unknown · faultyLEFT EMERGENCY ESCAPE NO TEST TEST2. PER MEL OVERWING EMERGENCY ESCAPE BOTLLES WERE VISUALLY VERIFIED TO BE PROPERLY CHARGED IAW AMM. RDF-T :TRIED M32 TEST PANEL FROM ANOTHER A-C NO HELP, TRIED RELAY K10486 (WDM 25-65-11) NO HELP, FOUND HIGH RES. ON WIRE W35SDR UALA2011100605417Wire · defectivePIGTAIL 56 SPARKING AND SMOKING. NO TIME TO FIX. PULLED CB FOR FOOD CART CONTROLLER 56. REPLACED CABLE NEW TECH CART (PIGTAIL) PER MM. OPS TEST FOR FOOD CART OPERATE NORMALLY.SDR AALA20111005JFK01Wire · defectiveRIGHT OVERWING SLIDE INOPERATIVE. REPLACED WIRE HARNESS REF WDM 25-65-12 FROM D4278P TO RIGHT SPOILER OVERRIDE ACTUATOR M956 DISCONNECT D1166.SDR FDEA201110014265Wire Harness · defectiveDOOR SLIDE LIGHT WILL NOT TEST OR ILLUMINATE WHEN PRESSED. TRIED NEW BATTERIES AND BLUBS NO HELP. SLIDE LIGHT ASSY HARNESS DEFECTIVE. REPLACED SLIDE LIGHT HARNESS ASSY IAW WDM 25-61-01. CHECKED GOOD IAW AMM 25-61-02-5. R & R R1 SLIDE IAW MM 25-61-02-4 PRSDR IPXA1M69635Wire Harness · shortedINSPECTION TYPE:3C L1 DOOR ESCAPE SLIDE REMOTE PRESSURE INDICATOR LIGHT WIRING HARNESS SHORTED, WARNING LIGHT ALWAYS ON, BOTTLE PRESSURE GOOD. PROCURED AND INSTALLED REPLACEMENT L1 DOOR ESCAPE SLIDE ASSY.SDR DALA1152180689Wire Harness · shortedFLIGHT DIVERTED TO SJU DUE TO COMPILING ELECTRICAL ISSUES, HAD T/O WARNING FOR FLAP CONFIG. CENTER BOOST PUMP "LOW PRESSURE WARNING. F/A HEARD A POP AND SAW SPARKS FROM LEFT AFT OVEN. OVEN C/B TRIPPED AND EMITTED AN ELECTRICAL ODOR. MAINTENANCE REPLACED THSDR CA110919002Cable · shorted(CAN) THE CABLE THAT RUNS FROM THE ELT REMOTE SWITCH TO THE ELT HAD A SHORT IN IT. THIS WAS CAUSING THE ELT TO ACTIVATE IN FLIGHT AND OR ON THE GROUND.SDR UALA2011082404543Cable · defectivePIGTAIL P56 -AFT GALLEY SPARKED - SMOKED-ELEC ODOR; NOW UNPLUGGED. FOUND CONNECTOR BURN. CB PULLED AND COLLARED. ITEM DEF PER MEL 2520ACX. NEED PARTS, NIL IN SGNMM. 1EA CABLE ASSY 561-2282 READY FOR LOB & HOLD AT NRTJL - TANI. 1EA CABLE AY 561-2282 LOB INSDR CA110815010Wire · burned(CAN) DURING SCHEDULED REVENUE OPERATION, THE COCKPIT AND CABIN CREW NOTICED AN ODOR OF HEAT AND ELECTRICS COMING FROM THE OVEN AREA IN GALLEY ONE. ACFT LANDED SAFELY. DURING INVESTIGATION, BURNED TERMINAL LUGS AT CB2 (OVEN NR 2) ON THE GALLEY CONTROL PANEL SDR UALA2011081204237Connector · intermittentSQUIB TEST FAIL ON NR 1 SYSTEM. NR 2 SYS INTERMITTENT. RESET CONNECTORS, ALL CHECKED OKAY.SDR FDEA201107232912Wire · brokenEVACUATION SLIDE REMOTE PRESSURE PRESS TO TEST INDICATING SYS INOPERATIVE. RELEASED FOR SERVICE IAW MEL: 25-61-01. FOUND WHITE WIRE AT BATTERY PACK BROKEN. REPAIRED WHITE WIRE TO BATTERY PACK IAW STANDARD WIRING PRACTICE 20-10-05. REMOVED AND REPLACED BULBSSDR UALA2011072503804Control Unit · faultedG4A GALLEY CB FOUND POPPED. REPLACED GALLEY ELECTRIC CONTROL UNIT FOR GALLEY G4A (M225) PERMM, CHECKED OKAY.SDR AALA20110728DFW01Wire Harness · shortedFOUND POWER PORT UNIT AT SEAT 12D HAD SHORTED OUT. REPLACED POWER SUPPLY J BOX AND POWER PORT HARNESS FOR 12DEF. OPS CHECK NORMAL.SDR UALA2011071503590Wire · damagedPIGTAIL P41 SHORT IN HARNESS AND WILL NOT HOOK. CART SLIGHT SIZZLE NOISE HEARD BY FLT ATTENDANT. PIGTAIL DAMAGED REQUIRES REPLACEMENT. REPLACED PIGTAIL, OPS GOOD.SDR UALA2011071103433Wire · damagedPIGTAIL P41 SHORTED WIRE AND WILL NOT COOK CART SLIGHT SIZZLE NOISE HEARD BY FLT ATTENDANT.SDR FDEA201107092622Connector · dirtyR1 DOOR REMOTE PRESSURE TEST INOPERATIVE ON PREFLIGHT VERIFIED SLIDE PRESSURE IN GREEN BAND (3300PSI). REF SRM 25-61-0 AND AMM 25-61-06-5, CLEANED DISCONNECT PLUG AND RESEATED LENS MODULE. SLIDE LOW PRESSURE PRESS TO TEST FUNCTIONS NORMAL. OK FOR SERVICSDR CA110708008Switch · failedSMOKE COMING FROM SEAT ROW 31 HJ. POWER REMOVED WITH IFE/PAX SWITCH. SMOKE STOPPED AND ELECTRICAL ODOR DECREASED AFTER REMOVAL OF POWER. DISPATCH AND MX ADVISED FOUND QSEB 31J AT FAULT. PART REPLACED SWITCH DOWNLOAD C/O. OPS OK. NO DAMAGE TO WIRING.SDR UALA2011062903193Cable · damagedSMOKE IN CABIN, FLIGHT DIVERTED. FOUND BAD SEAT ELECTRONICS BOX AT SEAT ROW 12 RIGHT. REPLACED SEAT ELECTRONICS BOX AND SEAT TO SEAT CABLE FROM ROW 12 DEF TO ROW 20 DEF. ALL TESTS PASS.SDR UALA2011062003007Wire Harness · damagedGALLEY CONTROLLER N51 DOES NOT COOK MIDDLE LEVELS OF CART. REF WDM 25-36-15 PG1, CHECKED WIRING BETWEEN D031P AND D038P, PIN-6 HAS NO CONTINUITY. FOUND CONNECTOR RECEPTACLE D031J PIN-6 HAS EVIDENCE OF BURN. NEED TO REPLACE CONNECTOR D031J REF WDM. DEACTIVATSDR UALA2011061702984Wire · shortedDOOR 1L SLIDE LIGHT WILL NOT ILLUMINATE WHEN SLIDE IS ARMED. TRIED ANOTHER LIGHT CAP NO HELP. COMPLIED WITH MEL CARD. VERIFIED LIGHT CAP WORKS AT OTHER LOCATION, FOUND WIRE SHORTED TO GROUND APPROX 2 OHMS, BETWEEN SPLICE SP50 AND W3582-A-PA, WITH OR WITHOUTSDR USAA2011061500006Wire Harness · misroutedLAX - EES - ELECTRICAL HARNESS MISROUTED ON R-2 DOOR ESCAPE SLIDE RAFT PACK. REROUTED ELECTRICAL HARNESS ON R-2 DOOR ESCAPE SLIDE RAFT PACK.IAW AMM 25-62-44-400-007-0.SDR USAA2011061500005Wire Harness · misroutedLAX - EES - ELECTRICAL HARNESS MISROUTED ON R-1 DOOR ESCAPE SLIDE RAFT PACK. REROUTED ELECTRICAL HARNESS ON R-1 DOOR ESCAPE SLIDE RAFT PACK IAW AMM 25-62-44-400-007-0.SDR USAA2011061500004Wire Harness · disconnectedLAX - EES - ELECTRICAL HARNESS NOT CONNECTED ON L-2 DOOR ESCAPE SLIDE RAFT. RECONNECTED ELECTRICAL HARNESS ON L-2 DOOR ESCAPE SLIDE RAFT PACK IAW AMM 25-62-44-400-007-0.SDR USAA2011061500003Wire Harness · misroutedLAX - EES - ELECTRICAL HARNESS MISROUTED ON L-1 DOOR ESCAPE SLIDE RAFT PACK. REROUTED ELECTRICAL HARNESS ON L-1 DOOR ESCAPE SLIDE RAFT PACK IAW AMM 25-62-44-400-007-0.SDR CLCA060920111Connector · brokenDURING ROUTINE INSPECTION, MIA, THE ELT FIXED CONNECTOR WAS FOUND BROKEN. ITEM WAS TRANSFERRED TO DMI IAW MD-11 AIRCRAFT MEL 25-676-1-2, CAT A. AIRCRAFT RETURNED TO SERVICE.SDR UALA2011052502551Cable · burnedAFT GALLEY NEW TECH CART CABLES P52, P61 & P62 HAVE BURNT PINS. REPLACED CABLE ASSEMBLIES, OPS CHECK NORMAL.SDR DALA1136145645Connector · burnedFORWARD GALLEY RIGHT HAND OVEN HEATING ELEMENT SHORTED OUT CAUSING SMOKE AND SPARKS. OVEN TURNED OFF AND CIRCUIT BREAKERS WERE PULLED. FLIGHT CONTINUED TO JFK AND LANDED WITHOUT INCIDENT. ON 08JUN11, SEA MAINTENANCE FOUND PIN 8 BURNT AT CONNECTOR D07P. REPLACESDR UALA2011052302526Wire · burnedDOOR2L SLIDE ARM LIGHT NOT ILLUMINATING WHEN DOOR IS ARMED. ON COMPLETION OF LM8651, FOUND BURNT WIRES ON FWD GIRT BAR PROXIMITY SWITCH. REPAIRED WIRE WITH ENVIRONMENT SPLICE. OPS CHECK SLIDE LIGHT GOOD.SDR CA120727002Connector · burned(CAN) AIRCRAFT WAS PARKED OVERNIGHT, BEFORE FLIGHT IN HUMID WEATHER CONDITION. AFTER POWERING UP THE ACFT AND CABIN ON APU GENERATOR, THE F/A HAD A KETTLE CONNECTED TO THE GALLEY ELECTRICAL OUTLET. SHE FELT A BURN ODOR AND SWITCHED THE POWER OFF. AFTER INSPECSDR UALA2011041301784Wire Harness · burnedFOUND DAMAGED,OPEN,BURNT WIRE HARNESS IN BAY STA 1642 TO STA 1664, RBL24 UNDER FLOORBOARDS. WIRES FOR POWER DRIVE UNITS. ORDERED REPLACEMENT WIRE AND STARTED MARKING, ID BROKEN LEADS. (AOG Y3604 3 COLOR CONDUCTOR. 561-1247). ID WIRES FOR R,B, AND Y LEADS REF WSDR UALA2011040801708Wire · chafedG4 GALLEY BEHIND UPPER ELECTRICAL CONTROL PANEL FEEDER WIRES 2456-1406-8 AND 2456-1407-8 CHAFED THRU TO CONDUCTOR 8 INCHES AFT OF CONNECTOR 9004ML4. ACCOMPLISHED EVA 80749. ALL AFT GALLEY COMPONENTS OPERATE NORMAL. NEEDS TO BE RECHECKED AT EACH 2A CHECK. RESDR UALA2011032301390Wire Harness · faultyEMERGENCY EVACUATION SIGNAL SYSTEM DEFECTIVE AT ATTENDANT SEAT AT DOOR 3L. 3L POSITION DOES NOT ALARM OR LIGHT WHEN SYSTEM TESTED AT OTHER LOCATIONS, IT DOES LIGHT AND ALARM WHEN TESTED AT 3L, BUT NO ALARM OR LIGHTS AT ANY OTHER LOCATION. PIGGYBACK GOOD EVACSDR UALA2011031501244Sleeve · tornAFT CARGO, PDU WIRES PROTECTIVE SLEEVE TORN AT BS 1335, RBL 34. REPAIRED DAMAGED CONDUITS AND SLEEVES IAW GNMM.SDR UALA2011031101181Connector · corrodedGREEN LIGHT ON TEST PANEL P61 FOR R EMER ESCAPE OVER WING SLIDE. TRIED NEW TEST RELAY K10487 AND HUNG NEW SQUIB, NO HELP. SHAKING WIRES ON P79 PANEL CAUSES LIGHT TO FLICKER. FOUND MOISTURE & CORROSION IN CONNECTOR D4083 0P & J ON P79 PANEL. CLEANED CONNECSDR YENA20110303207Terminal · burnedFLT 777 BOS-LAS FWD GALLEY COFFEE POTS BEGAN EMITTING AN ELECTRICAL BURN ODOR. ODOR DISAPPEARED AFTER TWO POTS WAS SHUT OFF. PERFORMED INSPECTION PER TSM 24-00-00-810-823, NO FAULTS FOUND. REMOVED COFFEEMAKERS AND INSPECTED. NO HELP, DEFECT REMAINS OPEN UNSDR DALA1114699875Connecting Rod · fireAFTER THE AIRCRAFT PARKED AT THE GATE, THE EXTERNAL ELECTRICAL CONNECTION CAUGHT FIRE. PASSENGERS WERE EVACUATED FROM THE AIRCRAFT. DURING THIS EVACUATION THE TAILCONE FAILED TO EJECT AND THE TAIL SLIDE DID NOT DEPLOY.SDR UALA2011022800977Wire · chafedLEFT WING SLIDE EICAS INTERMITTENT. REPEAT GRIPE. PSEU BITE SHOWS SAME FAULTS AS PREVIOUS. ADJUSTED S218 TARGET PER MM. REPAIRED CHAFED WIRE NR 216R-20 IN ADP BAY. SEU BITE AND SENSOR TESTS OK.SDR UALA2011022800968Connector · sparksPIGTAIL P53 WHEN PLUGGED INTO CART AND TURNED ON, SPARKS. PULLED CIRCUIT BREAKER CIRCUIT BREAKER COLLARED PIGTAIL CAPPED. REPLACED PIGTAIL, OPS OK.SDR 2011FA0000115Receptacle · failedTHE NR1 TERMINAL AND WIRING FOR THE LIQUID WARMER POT WAS FOUND TO BE ARCED AND OVERHEATED ON THE BACK OF THE GALLEY. DURING REPLACEMENT, FOUND TERMINAL WIRING HARDWARE LOOSE.SDR FDEA201102090510Light · inoperativeL1 DOOR SLIDE PTT LIGHT INOP. WIRE THAT ATTACHES TO C BATTERY HOUSING BROKEN OFF. RELEASED FOR SERVICE IAW MEL: 25-61-01, PRESS VERIFIED IAW MEL 25-61-01. ACFT OK FOR SERVICE.SDR UALA2011012500415Wire · inoperativeGALLEY PIGTAIL-ELECTRICAL INOPERATIVE AT AFT CTR-AFT GAL 425. THE WIRE IS OVRHEATING AND SPARKING, REPLACED PIGTAIL AT N52. OPS NORMAL.SDR AALA20110116DFW09Connector · burnedDFW - FLIGHT ATTENDANTS REPORTED ELECTRICAL ODOR IN CABIN. ODOR WENT AWAY AFTER UTILITY BUSSES WERE TURNED OFF. EMERGENCY DECLARED, FLIGHT RETURNED DFW LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND FIRST CLASS NUMBER 1 COFFEEMAKER TRAY CONNSDR USAA2011010390006Connector · disconnectedFLT 606 - PHX-LAS - EMERGENCY LIGHTS - EMERGENCY LIGHT TEST FAULTED" L EXTERNAL LIGHTS". FOUND L1 SLIDE EXTERNAL PLUG DISCONNECTED. RECONNECTED PLUG. OPERATIONAL CHECK WAS GOOD.SDR CA110104005Connector · burnedON A FLIGHT INBOUND THE CREW REPORTED AN ELECTRICAL BURNING ODOR AND ARCING NOISE COMING FROM THE OVERHEAD BIN AREA AT ROW 1 ON THE LT SIDE. MAINTENANCE INVESTIGATION FOUND AN ELECTRICAL CONNECTOR SHORTED, BURNED AND MELTED ABOVE THE LT ROW 1 OVERHEAD BIN. THSDR CA101224002Wire · burned(CAN) DURING CRUISE THE F/A REPORTED TO THE CAPTAIN A BURNING SMELL IN THE AFT GALLEY AREA. ELECTRICAL POWER WAS REMOVED FROM THE GALLEY AND THE SMELL DISSAPATED. CMC INTERROGATED REAR GALLEY POWER RESTORED BOTH COFFEE MAKERS TURNED ON OVEN TURNED ON BOTH PSDR FDEA201012054600Terminal · brokenR1 DOOR SLIDE REMOTE PUSH TO TEST LIGHT/INDICATOR IS INTERMITTENTLY INOP. RELEASED FOR SERVICE IAW MEL: 25-61-01 CATEGORY: C EXPIRATION: 15DEC10 MEL 25-61-01:RT EVAC SLIDE REMOTE PRESS INDICATOR INOP IAW MEL 25-61-01, VERIFY AND RECORD IN THE AML, EVAC SLIDSDR UALA2010112904372Wire · transposedNO SMOKING SIGN BURNED OUT OVER AFT FLT ATTENDANT JUMP SEAT. RELAMPED, NO HELP. FOUND WIRES TO TERMINALS 2 AND 3 TRANSPOSED. SWAPPED WIRES AND LIGHT CHECKS GOOD IN PROPER SEQUENCE.
Back to JASC 2597