JASC 2620
Service difficulty reports · 703
Reports filed under 2620 · Extinguishing System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2620' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2620' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR A6WA200840399Extinguisher · dischargedCARGO BOTTLE LOWER MESSAGE IN FLIGHT. COMPLIED WITH QRH. R&R LT CARGO FIRE BOTTLE IAW AMM 26-25-01. CHECKS GOOD. NO AIR LEAKS FOUND AND NO SMOKE PRESENT IN CARGO BAY. OK FOR SERVICE.SDR MASA200800369Warning System · malfunctionedASH FLT 2922 COS - FIRE BOTTLE WARNING MESSAGE. OPS CHECKED THE FIRE BOTTLE WARNING SYSTEM, NO DEFECTS NOTED.SDR FDKA200805190Extinguisher · inoperativeFDM 6132 MCO-RIC. BAG EXTINGUISHER BOTTLE INOP/ BAG LIGHT INDICATION. RESET SYSTEM, NO FURTHER ACTION REQUIRED.SDR MASA200800334Fire Bottle · warning messageFLT 2838 PHX-BUR. CARGO BOTTLE LOW CAUTION MESSAGE. DECLARED EMERGENCY AND DIVERTED TO LAS. REPLACED LEFT CARGO FIREX BOTTLE.SDR SWIA200819713Tube · deformedBAGGAGE FIRE EXTINGUISHER TUBE IS KINKED. (FOUND AT C-CHECK) REPLACED KINKED DISCHARGER TUBE PER CRJ200 AMM 26-25-07-400-801.SDR SWIA200819712Switch · sticksNR 2 ENGINE FIRE BOTTLE DISCHARGE SWITCH LIGHT STICKS CLOSED. (FOUND AT C-CHECK) REPLACED INNER SWITCH CONTACTS PER AMM 26-21-01-000-802.SDR GTIA0800052Pipe · crackedENGINE FIRE EXTINGUISHING PIPE OVER THE HOT SECTION (NR 2 ENG) IS CRACKED. REMOVED AND REPLACED PIPE AFT SECTION IAW A319 AMM 26-21-49.SDR HALA0800432Cartridge · malfunctioned"AGENT NR 1 LOW" ON. REMOVED AND REPLACED NR 1 FIRE BOTTLE PER AMM 26-21-01, OPS CHK GOOD OK TO CONTINUE. REMOVED AND REPLACED FIRE CONTAINER DISCHARGE CARTRIDGE PER AMM 26-21-02.SDR MASA200800220Fire Bottle · malfunctionedASH FLT 2950 PHX-ASE - LT FWD AND RT AFT FIRE BOTTLE WILL NOT ILLUMINATE DURING TEST. RESET, OPS GOOD.SDR YZ4R200800001Extinguisher · inoperativeFIRE EXTINGUISHER DID NOT ACTIVATE. THE FIRE EXTINGUISHER IS FILLED WITH 4.5 POUNDS OF HALON 1301 AND PRESSURIZED TO 600 PSIG WITH DRY NITROGEN. THE CONTENTS ARE HELD IN THE CYLINDER BY A PLUG VALVE, PN 13038 WITH AN O-RING SEAL. THIS PLUG VALVE IS COMPRESSED SDR 2008UALA00861Squib · faulty'ENG FIRE EXTINGUISHING-SQUIB' LIGHT OF 'AGENT 1' PUSHBUTTON SWITCH IS OFF DURING 'LOOP-SQUIB TEST'. SQUIB IS FAULTY. REPLACED SQUIB, ALL OPS CHECKS NORMAL.SDR MWEA080029B-Nut · disconnectedLEFT ENGINE FIRE SUPPRESSION LINE AFT "B" NUT DISCONNECTED. RECONNECTED "B" NUT. SURPRESSIONSDR QXEA200800003Fire Bottle · malfunctionedSEA - FLIGHT 2264 - FORWARD BAGGAGE COMPARTMENT FIRE TEST BOTTLE WOULD NOT ARM. MAINTENANCE PLACED ON MEL 26-20-4B. AIRCRAFT RETURNED TO SERVICE.SDR FDKA200801003Seal · brokenFDM 6024 MCO (1669 PHX LCL) - SEAL ON FLIGHT DECK FIRE EXTINGUISHER WAS BROKEN. MX INSPECTED AND RESEALED THE EXTINGUISHER AS REQUIRED.SDR GUUA11240701Annunciator · warning lightFLIGHT: 9269, DURING FLIGHT, RT FIRE DISCHARGE ANUNCIATOR ILLUMINATED. REPLACED TERMINAL ON RT FIRE EXTINGUISHER.SDR FDKA200711333Bottle · unknownFDM 6150 TYS (0517 PHX LCL) - BAGGAGE EXTINGUISHING BOTTLE CAUTION ILLUMINATED. MX REMOVED AND REPLACED BAGGAGE BOTTLES, OPS CHECKED GOOD.SDR WGEA200700024Fire Bottle · leakingEVIDENCE OF FIRE SUPPRESSION AGENT LEAKING INTO RIGHT ENGINE. SUPPLEMENTAL INFORMATION, CLEANED ENGINE IAW PWC EMM 71-00-00-108-808 AND PWC FSR RECOMMENDATION LETTER.SDR 2007UALA04420Control Panel · faultyCARGO FIRE DET SYSTEM 1ST BOTTLE ARMED GREEN LIGHT IS ILLUM. ARM SWITCH IS AUTO. SYSTEM TEST OK. REPLACED CARGO FIRE CONTROL PANEL- ALL INDICATIONS ARE NORMAL.SDR MASA200700695Fire Bottle · no testASH FLT 7258 ORD-MSN - NR 2 CARGO FIRE BOTTLE WOULD NOT TEST. MX RESET THE TEST SYSTEM AND IT OP CHECKED GOOD.SDR HNAA0700182Relay · unknownCREW ATTEMPTED TO DISCHARGE APU FIRE BOTTLE. FIRE BOTTLE DID NOT DISCHARGE. (VERIFIED IN ROA ON 2 OCT 07). VERIFIED 28 VOLTS AT SQUIB CONNECTOR. REPLACED SQUIB AS PRECAUTION. OPS CHECKED OLD SQUIB, CHECKED GOOD. SUSPECT FAULT CAUSED BY APU AIR/GROUND RELSDR WRLA2007101Ring · missingDURING C-CHECK FOUND NR 3 ENGINE FIRE EXTINGUISHING LINE JOINT RING MISSING. REF N/R 67308. 10-12-07 INSTALLED JOINT RING REF DC10 AMM 26-21-04 REV.81. LEAK CHECKED REF DC10 AMM 26-21-04-201 REV.81.
SDR 2007UALA03876Terminal · corrodedAPU DISCHARGE LIGHT ON INTERMITTENTLY. CLEANED CORRODED TERMINALS AT L26504 GD TERMINAL 2, AT P5 BTL DISCH AND AT P40 BTL DISCH LIGHT. OP CHECKS GOOD.SDR WRLA2007100Seal · missingDURING C-CHECK FOUND THE LOWER CENTER CARGO COMP FIRE EXTINGUISHING LINE JOINT IS OPEN AND SEAL RING IS MISSING AT STA1441. N/R 66723. REINSTALL THE LINE JOINT WITH SEAL RING AND TEST THE DEPLOYMENT LINES REF DC10 AMM 26-22-03.201 REV 81.SDR QXEA200701428Squib · blownSMF FLIGHT NR 2359: 45 MINUTES INTO FLIGHT FROM PDX, MASTER WARNING AND CHECK FIRE DETECT LIGHT ILLUMINATED. ALSO BAGGAGE AFT AND FWD FIRE BOTTLE CAUTION LIGHT ILLUMINATED. MAINTENANCE PER Q400 FIM TASK 26-10-00-810-815, ITEM 4A(1). REMOVED AND REPLACED LOWSDR COMA0760562Relay · faultyFLIGHT 5180 - RECEIVED CARGO BOTTLE LOW MESSAGE. PERFORMED QRH, SQUIBS DID NOT TEST. DIVERTED TO CRW, LANDED WITHOUT INCIDENT. REPLACED RELAY K8HL. NO FURTHER DEFECTS.SDR COMA0760561Relay · faultyFLIGHT 5180 - RECEIVED CARGO BOTTLE LOW MESSAGE. PERFORMED QRH, SQUIBS DID NOT TEST. DIVERTED TO CRW, LANDED WITHOUT INCIDENT. REPLACED RELAY K7HL. NO FURTHER DEFECTS.SDR COMA0760560Relay · faultyFLIGHT 5180 - RECEIVED CARGO BOTTLE LOW MESSAGE. PERFORMED QRH, SQUIBS DID NOT TEST. DIVERTED TO CRW, LANDED WITHOUT INCIDENT. REPLACED RELAY K6HL. NO FURTHER DEFECTS.SDR 2007UALA03202Squib · blownRIGHT ENGINE SQUIB TEST LIGHT WILL NOT LIGHT UP DURING TEST POSITION 2. AS PART OF TROUBLESHOOTING VERIFIED SQUIB CIRCUIT, AND DURING TEST FOUND RIGHT ENGINE SQUIB BOTTLE BLOWN. REPLACED SQUIB.SDR CA070817006Manifold · malfunctioned(CAN) DURING CRUISE, AT APPROXIMATELY 7000 FEET AND THE RETARDANT SYSTEM DE-ARMED, THE RETARDANT TANK CONTENTS EXITED THE TANK. THE CREW RETURNED TO BASE. MAINTENANCE TROUBLESHOT THE SYSTEM AND THE HYDRAULIC MANIFOLD FOR THE RETARDANT TANK WAS REPLACED. THE TSDR A6WA200740367Fire Bottle · unknownMAINTENANCE REPORTED RT ENGINE BOTTLE NR 2 PUS-TO DISCHARGE GREEN PUSHBUTTON WOULD NOT ILLUMINATE WHEN TESTED. REMOVED AND REPLACED RT ENGINE FIRE BOTTLE FIRE BOTTLE. OPS CHECK GOOD. (K)SDR 2007UALA02442Extinguisher · unserviceableF/A REPORTS FIRE EXTINGUISHER IN AFT LAV SHOWS PRESSURE ON RED BAND. REMOVED AND REPLACED AFT LAV FIREXT.SDR 07FDEA02388Head · shearedMDIS: PER FLIGHT CREW, ON PREFLIGHT FOUND EAD ALERT NR 2 ENG NR 1 FIRE BOTTLE PRESSURE LOW ALERT AND OVERHEAD DISCHARGE LIGHT ON. WHILE T/S CONFIRMED NR 2 ENG NR 1 FIRE BOTTLE IS DISCHARGED. FOUND ON ENG SIDE OF BOTTLE DISCHARGE HEAD ASSY TO BE SHEARED IN HASDR 2007UALA02126Fire Bottle · failedENG 1 AGENT 1 DISCHARGE LIGHT ILLUMINATED AFTER 3 HRS OF FLIGHT. FOUND ENGINE FIRE BOTTLE FAILED. REPLACED ENGINE 1 FIRE BOTTLE. SYSTEM CHECK OK.SDR 2007UALA02116Fire Bottle · faultyCARGO FIRE BOTTLE 2 DISCHARGE LIGHT ON. [07-13-07] REPLACED BOTH FIRE BOTTLES.SDR NSVA20070145Warning Light · unknownNO PUSH TO EXTINGUISH LIGHT DURING AMP TEST ON RIGHT SIDE. REMOVED AND REPLACED RIGHT ENG. FIRE BOTTLE AND SQUIB ASSY. REMOVED AND REPLACED RIGHT FIRE "T" HANDLE ASSY. OPS CHECK GOOD IAW COLGAN WORK CARD NR 26-20-05 AND MM CH 26-00-00.SDR 2007UALA01609Squib · no testFIRE EXTINGUISHER SQUIB TEST INOPERATIVE. [06-15-07] LIGHT CIRCUIT FAILS. REPLACED LIGHT PANEL. FOUND SQUIB OP-TEST SATISFACTORILY PER MM26-21-00. A/C OK FOR SERVICE.SDR 2007UALA01593Bottle · inoperativeCARGO DETECT 2ND BOTTLE ARMED LIGHT INOPERATIVE. REPLACED FIRE BOTTLE AND SQUIB- ALL TESTED NORMALLY.SDR TRAX200700559Warning System · activatedAPU SQUIB AND APU BOTTLE LOW MESSAGES. APU FIRE EXTINGUISHING SYSTEM - APU INOPERATIVE.SDR TRAX200700551Warning System · activatedCARGO BOTTLE LOW MSG ILLUMINATED ON DEPARTURE. RETURNED TO GPT. EMERGENCY DECLARED. FLT 4546 DEL 200 MINS. CARGO COMPARTMENT FIRE EXTINGUISHING SYSTEM.SDR 2007UALA01169Squib · no testFOUND CARGO 2 BOTTLE ARMED LIGHT WILL NOT TEST. [SUP 05-01-07] FOUND BAD NR 2 BOTTLE SQUIB AND REPLACED THE SAME.SDR MALA070049Switch · inoperativeFOUND LT FIRE T-HANDLE SWITCH 1 INOPERATIVE DURING FUNCTIONAL CHECK OF ENGINE FIRE BOTTLES. RESERVE CARTRIDGE ON RIGHT FIRE BOTTLE WOULD NOT FIRE DUE TO SWITCH INOPERATIVE. INSTALLED NEW LT FIRE PULL HANDLE PANEL P/N: 7239038-503, S/N ON: 941442, S/N OFF: 07SDR DL75A070293Fire Bottle · malfunctionedAPU QUIT ON PUSHBACK AS POWER CORD WAS REMOVED SIMULTANEOUSLY APU FIRE DISCHARGE LIGHT ILLUMINATED. FOUND BOTTLE DISCHARGED. CHECKING CIRCUITRY FOR UNCOMMANDED BOTTLE DISCHARGE. TESTED OK PER AMM.SDR NOCA07107Fire Bottle · dischargedPRIOR TO DEPARTURE THE APU SHUTDOWN AND THE APU FIRE BOTTLE DISCHARGE LIGHT CAME ON. INSPECTED THE APU COMPARTMENT AND FOUND NO EVIDENCE OF APU FIRE, THERE WAS EVIDENCE THAT THE APU FIRE BOTTLE HAD DISCHARGED. REPLACED APU FIRE BOTTLE, PERFORMED BITE ON THE SDR 2007UALA00699Light · no testBOTTLE 2 DISCHARGE LIGHT INOP, WON`T TEST. RELACED LIGHT.SDR 45AX022607Fire Bottle · false indicationFIRE BOTTLE GAUGE HAS INACCURATE INDICATION, FOUND TO INDICATE (0) ON PREFLIGHT. THE BOTTLE WAS REMOVED AND DETERMINED TO BE FULL OF AGENT AND NOTICED ROTATING THE BOTTLE MOVED THE PRESSURE GAUGE. BY HAND SHAKING THE BOTTLE THE PRESSURE INDICATION WOULD MOVESDR 2007UALA00467Hose · kinkedFIREX HOSE GOING FROM BOTTLE TO NR 2 ENG DISCHARGE TUBE HAS A KINK THAT IS APPROX 20 PERCENT OF THE DIAMETER OF THE HOSE. -SD04-17-07- REPLACED HOSE.SDR NSVA20070036Shutoff Valve · inoperativeFOUND LT ENGINE FIREWALL SHUTOFF VALVE IS INOP. REMOVED AND REPLACED LT ENGINE FIREWALL SHUTOFF VALVE PN/OFF/ON 118-389005-1, SN/OFF 9307076 SN/ON9031512, OPS CHECK GOOD.SDR DJFA2007014Pin · bentDURING THE SCHEDULED REPLACEMENT OF THE SQUIBS AND FIRE BOTTLES MAINTENANCE DISCOVERED A PIN BENT OVER ON THE FORWARD FIRE BOTTLE SQUIB WHICH WOULD HAVE PREVENTED THE DISCHARGE OF THE BOTTLE DURING AN EMERGENCY. THE SDR WILL BE UPDATED UPON COMPLETION OF THE SDR COMA0760013Fire Bottle · faultyFLIGHT 5025 - DURING CRUISE AT FL 290, CARGO BOTTLE LOW CAUTION MESSAGE. REMOVED AND REPLACED CARGO BOTTLE.SDR CA061213002Switch · jammed(CAN) BOTH CARGO FIRE X-BOTTLES DISCHARGED WHEN , NORMAL CARGO SMOKE PUSH) SWITCH-LIGHT ACTUATED TO ARM THE DISCHARGE SQUIBS. AFTER INVESTIGATION FOUND THAT BOTTLE ARMED (PUSH TO DISCHARGE) SWITCH-LIGHT JAMMED IN THE (PUSH) POSITION. (TC NR 20061213002)
Back to JASC 2620