SDR ASAA2017011119322Pump · failedTHE NR 1 AFT BOOST PUMP LIGHT ILLUMINATED WITH SWITCH ON. ACFT GROUNDED. FOUND THE CIRCUIT BREAKER CLOSED, BUT CFI OPEN WITH WHITE BAND SHOWING. RESET THE GFI, LIGHT EXTINGUISHED THEN REILLUMINATED. WHITE BAND IS SHOWING ON GFI. AFTER GFI RESET , LOW PRESSSDR AALA20170109020Pump · malfunctionedPREMATURE FUEL BURN FROM RIGHT MAIN TANK WITH ALL FUEL BOOST PUMPS ON AND CROSS FEED CLOSED. OVER 600 LBS BURNED FROM RIGHT MAIN TANK, FUEL STILL AVAILABLE IN CENTER TANK. REMOVED AND REPLACED RIGHT CENTER FUEL BOOST PUMP IAW AMM 28-22-41.SDR DALA2017010300015Pump · failedDIVERTED DUE TO THE CIRCUIT BREAKER FOR THE RIGHT WING FORWARD FUEL BOOST PUMP TRIPPED AT FL 330. CREW RECEIVED EOAP MESSAGE RT FUEL INLET PRESSURE LOW AND THE RIGHT WING AFT FUEL BOOST PUMP WAS ON MEL. CREW WAS ABLE TO CROSSFEED FUEL FROM THE LEFT WING TANSDR AALA201701039010Pump · faultedCENTER FUEL TANK PUMP 1 FAULT. PERFORMED TSM 28-21-00-810-813-A, NO ECAM FAULTS NOTED FUNCTIONAL TEST CENTER TANK FUEL PUMP NR 1 OPERATIONAL CHECKED GOOD. CENTER TANK FUEL PUMP GFI OPERATIONAL CHECKED GOOD PER AMM 28-18-00-710-801-A. AS A PRECAUTION, REPLACED SDR AALA20170103006Pump · faultyAIRCRAFT NOT GROUNDED. FUEL IN CENTER EICAS DISPLAYED 45-60 MINUTES AFTER CENTER FUEL PUMPS WERE TURNED OFF. 2200 LBS IN CENTER TANK. CENTER FUEL PUMPED OUT AND SAME EICAS MESSAGE DISPLAYED. REMOVED AND REPLACED LEFT CENTER FUEL SCAVENGE JET PUMP ASSEMBLY IASDR AALA201612319002Switch · malfunctionedDURING CLIMB, COCKPIT CENTER TANK NR 1 FUEL PUMP FAULT, LOW PRESSURE. REPLACED FUEL PUMP SWITCH IAW AMM 28-97-00 OPS.SDR ASAA2016122819182Pump · failedNR 2 FUEL TANK, AFT PUMP, LOW PRESSURE LIGHT ILLUMINATED WITH SWITCH ON AND QUANTITY IN TANK READING 8.56. GROUNDED - YES. REMOVED AND REPLACED NR 2 FUEL TANK AFT PUMP WITH SERVICEABLE UNIT, REF AMM 28-22-41. OPS CHECKS GOOD, REF AMM 28-22-41.SDR AALA20161220006Pump · faultyRIGHT WING TANK OVERFLOW CAUTION LIGHT ILLUMINATED UPON LANDING. AIRCRAFT WAS GROUNDED. REMOVED AND REPLACED RIGHT WING JET PUMP IAW AMM 28-21-53, OVERFLOW SENSOR IAW 28-46-16 AND FUEL LEVEL SENSING CONTROL UNIT 2 IAW AMM 28-46-34. OPERATIONAL CHECK GOOD.SDR AALA20161212002Control Module · inoperativeDURING CRUISE, THE RIGHT CENTER FUEL PUMP DID NOT FULLY SUPPLY THE NR 2 ENGINE FUEL FLOW. RIGHT MAIN TANK QUANTITY DECREASES WITH CENTER FUEL AND BOTH CENTER PUMPS ON. EMERGENCY DECLARED. LANDING UNEVENTFUL. AIRCRAFT GROUNDED. MAINTENANCE ACCOMPLISHED FIMSDR FDEA201612114381Warning Light · false activationAT LEVEL OFF, RECEIVED A CTR L FUEL PUMP ALERT WITH 5.1 OF FUEL IN CENTER TANK. REACTIVATED LT CTR OVERRIDE FUEL PUMP. AUDIBLE CHECKED THE LT CTR OVERRIDE PUMP FOR OPERATION, PUMP IS RUNNING. TRANSFERRED 22 KLBS INTO CENTER FUEL TANK. LT CTR OVERRIDE PUMSDR HALA2016120900529Pump · faultedUPON APU START UP, AFTER LANDING, ECAM CAUTION "FUEL APU AFT PUMP FAULT. CAUTION CONDITION INTERMITTENT. FOUND APU AFT PUMP FAULT ON FCMC GRD REPORT. REMOVED AND REPLACED APU AFT PUMP (3QC) PER AMM 28-22-52-400-801-A. OPS CHK OK. A/C OK FOR SVC. PUMP, FUEL FESDR AALA20161212011Switch · faultyRIGHT CENTER FUEL PUMP LOW PRESURE DOES NOT EXTINGUISH WHEN PUMP IS TURNED ON WITH FUEL IN CENTER TANK. REMOVED AND REPLACED POWER SWITCH RELAY IAW SPM 20-81-11. OPERATIONAL CHECK GOOD.SDR ASAA2016120518943Motor · failedLEFT AFT LOW PRESSURE LIGHT ILLUMINATED. GROUNDED - YES. REMOVED AND REPLACED NR 1 TANK AFT BOOST PUMP MOTOR IMPELLER IAW AMM 28-22-41. OPS AND LEAK TEST GOOD.SDR AALA201612069013Pump · failedTHE NR 1 AND 2 CENTER FUEL TANK BOOST PUMP FAILED. AIRCRAFT WAS GROUNDED. AIRCRAFT RETURNED TO DEPARTURE AND DECLARED AN EMERGENCY. MAINTENANCE REPLACED THE PUMPS GFI 69QA, AND 70QA, ALONG WITH THE FUEL QUANTITY INDICATION COMPUTER IAW ESPM 20-46-50-101, ANSDR AALA201612069012Pump · failedNR 1 AND 2 CENTER FUEL TANK BOOST PUMP FAILED. AIRCRAFT WAS GROUNDED. AIRCRAFT RETURNED TO DEPARTURE AND DECLARED AN EMERGENCY. MAINTENANCE REPLACED THE PUMP GFI 69QA, AND 70QA ALONG WITH THE FUEL QUANTITY INDICATION COMPUTER IAW ESPM 20-46-50-101, AND 24-4SDR AALA20161202010Pump · faultyDURING CLIMB THE CENTER FUEL PRESSURE LIGHT ILLUMINATED. DEACTIVATED MAIN PUMPS TO GET FUEL OUT OF CENTER TANK. AIRCRAFT WAS GROUNDED. REMOVED AND REPLACED CENTER BOOST PUMP UFI IAW AMM 28-20-28, EXTRACTION CHECK VALVE IAW AMM 28-20-26-401, AND FORWARD AND AFSDR AALA20161202009Pump · faultyDURING CLIMB, THE CENTER FUEL PRESSURE LIGHT ILLUMINATED. DEACTIVATED MAIN PUMPS TO GET FUEL OUT OF CENTER TANK. AIRCRAFT WAS GROUNDED. REMOVED AND REPLACED CENTER BOOST PUMP UFI IAW AMM 28-20-28, EXTRACTION CHECK VALVE IAW AMM 28-20-26-401, AND FORWARD AND SDR UIEA2016113000917Sleeve · corrodedLEFT FWD BOOST PUMP SHUTOFF SLEEVE FOUND WITH A HOLE ON SLEEVE STRUT OUTSIDE OF THE LIMITS DUE TO EROSION. THE SLEEVE REPLACED IAW MM 28-22-03.SDR JIKA2016112001Pump · intermittentTHE PILOT WAS EN-ROUTE WHEN THE RT FUEL TRANSFER LIGHT ILLUM. FOLLOWED THE QRH AND SWITCHED TO THE RT AUX FUEL BOOST PUMP FROM THE MAIN AND THE LIGHT EXTINGUISHED. MINUTES LATER THE LT FUEL TRANSFER LIGHT ILLUM AND FOLLOWING THE SAME PROCEDURES AND SWITCHED BOSDR ASAA2016111818739Pump · failedDURING PREFLIGHT, LEFT MAIN FWD FUEL PUMP LOW PRESSURE LIGHT REMAINED ILLUMINATED WHEN SWITCH TURNED ON. ACFT GROUNDED. REMOVED AND REPLACED LEFT MAIN FWD BOOST PUMP IAW AMM 28-22-41. OPS CHECK GOOD IAW AMM 28-22-41.SDR AALA201611149017Pump · failedWHEN NR 1 LEFT FUEL PUMP WAS TURNED ON, A FAULT INDICATED. REPLACED L1 PUMP (21QA) IAW AMM 28-21-51.SDR ASAA2016111118622Pump · failedAFTER LANDING LEFT FWD FUEL PUMP LOW PRESSURE LIGHT ILLUMINATED. PLENTY OF FUEL IN THE TANK. ACFT GROUNDED. CONFIRMED FWD LEFT FUEL PUMP INOPERATIVE. REPLACED THE FUEL PUMP IAW AMM 28-22-41 ALL OPS CHECKED NORMAL.SDR UIEA2016110900834Relay · failedRIGHT FWD BOOST PUMP PRESS LIGHT INDICATION ON PUSH BUTTON SWITCH FAILED TO COME ON WITH GFI TRIPPED. REMOVED AND REPLACED TIME DELAY RELAY (K-5) ON FUEL CONTROL PANEL FOR RIGHT FWD BOOST PUMP PRESS LIGHT INDICATION.SDR CALA2016110700863Pump · unserviceableEMERGENCY DECLARED. PUMP INDICATION, LEFT TANK PUMP 1 INOP & RIGHT TANK PUMP 1 INOP ON FUEL SYSTEM ECAM. FOUND LT WING TANK PUMP1 AND PUMP 2 LOW PRESSURE. RESET CB A14. FOUND PUMP 1 TO OPERATE NORMALLY. PUMP 2 FOUND TO BE INTERMITTENT. REPLACED BOTH LT WSDR P5CA2016110200285Pump · malfunctionedNR 1 LEFT FWD FUEL PUMP EICAS MESSAGE. REMOVED AND REPLACED THE LT FWD. FUEL BOOST PUMP IAW AMM 28-22-03. OK FOR SERVICE.SDR SWAA2016110109290Actuator · faultyINFLIGHT SHUT DOWN/AIR TURNBACK/DECLARED EMERGENCY. FUEL GAUGES WERE EQUAL ON TAKEOFF ABOUT 6 MIN AFTER TAKEOFF WE NOTICED A 900 LB IMBALANCE NR 1 SIDE LOW. AT 15 MIN AFTER T/O 1700 LB IMBALANCE NR 1 SIDE LOW. NR 2 GAUGE DECREASED AT NORMAL RATE & NEVER INCSDR 2016FA0000556Washer · detachedDURING A 50 HOUR INSPECTION/OIL CHANGE THE QUICK DRAIN OIL DRAIN BECAME WEDGED OPEN BY DEBRIS/FOD. THE QUICK DRAIN WAS REMOVED AND INSPECTED BY MAINTENANCE PERSONEL AND IT WAS DETERMINED THAT FOD/DEBRIS WAS THE WASHER FROM THE ENGINE DRIVEN FUEL PUMP. FUEL PUSDR FDEA201610263703Relay · failedAT FL 370 , THE NR 2 LEFT INNER PUMP FAULTED. PUMP FAULTED AND STRONG ACRED ODOR IN THE COCKPIT AND THE AVIONICS COMPARTMENT, ON DESCENT THE REMAINING THREE INNER PUMPS FAULTED AND FUEL FEED RESORTED TO OUTER TANK TO ENGINE. ACCESSED THROUGH THE COCKPITSDR EBTR201610150001Pump · inoperativeENROUTE FROM APN TO MKG, DURING CRUISE AT 8,000 FT APPROXIMATELY 20 MINUTES FROM MKG, FUEL SYSTEM AUTOMATICALLY SWITCHED TO CROSSFEED TO SUPPLY FUEL TO RT ENGINE, INDICATING THAT THE RT ENGINE HAD A FUEL PRESSURE DROP. THIS IS NORMAL SEQUENCE OF EVENTS FOR AISDR UIEA2016100500802Pump · inoperativeLEFT FWD FUEL PUMP INOPERATIVE, RESET CIRCUIT BREAKER LT & FWD BOOST PUMP, OPS CHECKED GOOD IAW AMM 28-22-03.SDR HYIA20161005001Pump · leakingPILOT REPORTED STRONG FUEL ODOR IN CABIN. MAINTENANCE INSPECTED HEATER AND HEATER FUEL INLET, FOUND HEATER FUEL PUMP LEAKING AND REPLACED THE HEATER FUEL PUMP, OPERATIONAL AND LEAK CHECKED GOOD. ADDITIONAL DETAILS WILL BE MADE AVAILABLE UPON TEARDOWN REPORT RESDR AALA201609309029Pressure Switch · faultedNR 1 FUEL PUMP CENTER TANK FAULT LIGHT ON DESCENT. REPLACED NR 1 FUEL PUMP PRESSURE SWITCH 39QA AND ACCOMPLISHED A SATISFACTORY LEAK OPERATIONAL CHECK IAW AMM 28-21-15.SDR ASAA2016091418014Warning Light · illuminatedBOTH CTR TANK FUEL PUMP LIGHTS REMAIN ON WITH PUMPS ON. ACFT GROUNDED. PERFORMED FIM 28-22 TASK 801 & 802. CTR TANK FUELED TO 14000 LBS & PUMPS REPRIMED. BOTH CTR TANK BOOST PUMPS OPS NORMAL. ALL GROUND FUNCTIONAL TESTS PASSED.SDR UIEA2016091400759Line · damagedRT AFT FUEL PUMP LIGHT CAME ON 35 MINUTES INTO FLIGHT , PERFORMED QRH . PERFORMED FIM 28-22 FT 819 BLEED AFT RT BOOST PUMP PRESSURE SENSE LINE IAW AMM 28-42-01 NO DEFECTS NOTED OPS CHECK NORMAL.SDR AALA20160907010Pump · faultedUNABLE TO TRANSFER FUEL FROM CENTER TANK AND FORWARD BOOST PUMP CIRCUIT BREAKER WAS FOUND TRIPPED. EMERGENCY WAS NOT DECLARED. UNEVENTFUL LANDING. REMOVED AND REPLACED THE CENTER FUEL TANK AFT BOOST PUMP IAW AMM 28-20-07-201, OPS CHECKED GOOD.SDR AALA20160829003Pump · faultyLANDED DUE TO UNABLE TO TRANSFER FUEL FROM CENTER TANK AND FORWARD BOOST PUMP CIRCUIT BREAKER WAS FOUND TRIPPED. EMERGENCY WAS NOT DECLARED. UNEVENTFUL LANDING. PLACARDED THE CENTER TANK BOOST PUMPS IAW MEL 28-01B. THE AIRCRAFT WAS NOT GROUNDED. R & R CENSDR HALA2016082900339Warning Light · false activationFUEL RIGHT PUMP 1 LOW PRESSURE ILLUMINATED DURING CRUISE. TROUBLESHOT IAW TSM 28-21-00-810-855A, ACCOMPLISHED FAULT ISOLATION PROCEDURE & FCMS 1&2 BITE TEST,OK AS PER AMM 25-51-00-740-801A. PUMP OPS TEST ALSO NORMAL. ACFT OK FOR SERVICE.SDR 2016FA0000407Pump · leakingLEAKAGE IN THE ELECTRIC FUEL PUMP.SDR AALA201608199010Pump · inoperativeCENTER TANK PUMP NR 2 INOPERATIVE. REPLACED CENTER TANK NR 2 FUEL PUMP AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 28-21-51.SDR AALA20160815004Pump · malfunctionedDURING CLIMB, THE CENTER FUEL PRESSURE LOW LIGHT ILLUMINATED AND THE CENTER BOOST PUMP CIRCUIT BREAKER TRIPPED. R & R CENTER AFT BOOST PUMP IAW AMM 28-20-07.SDR AALA201608129018Switch · inoperativeAIRCRAFT WAS NOT GROUNDED: RT TANK FUEL PUMP NR 1 INOPERATIVE. REPLACED NR 1 FUEL PUMP SWITCH 14QA IAW ESPM 20-15-11 AND ACCOMPLISHED A SATISFACTORY OPS CHECK.SDR SWAA2016080854599Actuator · inoperativeFUEL CROSSFEED VALVE INOPERATIVE. R & R FUEL CROSSFEED VALVE ACTUATOR IAW MM.SDR FDEA201608032823Pump · obstructedDURING INSPECTION OF RT WING TANK A FOREIGN OBJECT WAS DETECTED. A PARTIALLY DISINTEGRATED CLOTH, RAG WAS IDENTIFIED COVERING, BLOCKING THE AFT FUEL PUMP AT POSITION WS 231.5. AN EVALUATION OF THE SYSTEM FOR CONTAMINATION TO BE PERFORMED IAW SNRM N00480, W/O SDR AALA201607319002Pressure Switch · failedECAM FUEL LEFT PUMP 1 LOW PRESSURE. MAINTENANCE PERFORMED TSM 28-21-00-810-852A AND FOUND NO CIRCUIT BREAKERS TRIPPED AND NO DEFECTS NOTED DURING AN OPERATIONAL CHECK OF THE PUMPS. REPLACED FUEL PUMP PRESSURE SWITCH IAW AMM 28-21-15 AND ACCOMPLISHED A SATISFSDR ASAA2016073017555Pump · malfunctionedRIGHT CENTER TANK FUEL PUMP LOW PRESSURE LIGHT ILLUMINATED WITH 1000 LBS OF CENTER TANK FUEL REMAINING. ACFT GROUNDED. SUSPECT RIGHT CENTER FUEL PUMP LOST ITS PRIME. RIGHT CENTER TANK LOW PRESSURE LIGHT EXTINGUISHED WITH SWITCH SELECTED ON AFTER FUELING ANSDR ASAA2016072717534Pump · malfunctionedLEFT CENTER FUEL PUMP LOW PRESSURE LIGHT WOULD NOT EXTINGUISH WHEN SELECTED ON, IN CRUISE 900 LBS IN CENTER TANK. ACFT GROUNDED. PERFORMED FIM 28-22, TASK 801. FOUND LT CENTER BOOST PUMP LOST ITS PRIME. FUELED CENTER TANK TO 14,000 LBS AND LT CENTER BOOST PSDR AALA201607069010Pressure Switch · failedLEFT HAND WING TANK PUMP 1 LOW PRESSURE ECAM MESSAGE. REPLACED FUEL PUMP PRESSURE SWITCH 23QA PER AMM 28-21-15.SDR AALA201607039004Relay · defectiveRIGHT CENTER TANK FUEL PUMP WILL NOT OPEN IN AUTO MODE WORKS IN MANUAL MODE. REPLACED PUMP 2 INHIBIT RELAY 50QA (PN E0242A28A0) AND AUTO CONTROL RELAY 42QA (PN E0244-28A0) PER ESPM 20-46-50. REPLACED CENTER TANK LOW LEVEL RELAYS 46QA AND 45QA PER ESPM 20-46-50SDR AALA201607039003Relay · defectiveRIGHT CENTER TANK FUEL PUMP WILL NOT OPEN IN AUTO MODE WORKS IN MANUAL MODE. REPLACED PUMP 2 INHIBIT RELAY 50QA (PN E0242A28A0) AND AUTO CONTROL RELAY 42QA (PN E0244-28A0) PER ESPM 20-46-50. REPLACED CENTER TANK LOW LEVEL RELAYS 46QA AND 45QA PER ESPM 20-46-50SDR AALA201607029007Pump · low pressureCLASS 1 MESSAGE : FUEL CENTER TANK PUMP 1 LOW PRESSURE. REPLACED LEFT HAND CENTER FUEL TANK FUEL PUMP AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 28-21-51.
Back to JASC 2822