SDR 2007FA0000601Fitting · crackedFOUND CRACKED HYDRAULIC TEE FITTING, PN MS21911D6, IN AUXILIARY HYDRAULIC SYSTEM FILTER RETURN LINE. CRACK WAS FOUND AT THE MALE END WHERE END AND TEE BODY COME TOGETHER. REPLACED FITTING AND PRESSURIZED AND LEAK CHECKED SYSTEM. OP'S CHECK WAS GOOD, NO LEAKS SDR RAIA00707018Manifold · leakingFLT NR 5505 - STL - DURING FLIGHT -EICAS MESSAGE- NR 1 HYDRAULIC OVERHEAT MESSAGE, RAN CHECKLIST TURNED NR 1 SYSTEM OFF DURING DESCENT INTO STL. TURNED SYSTEM BACK ON AS PER CHECKLIST AND GOT A NR 1 SYSTEM FAIL-E1 HYD PUMP FAIL HYD NR 1 SOV CLOSED ON FINAL APSDR TSAA0729040Hose · failedFLIGHT 26 HNL-OGG - AFTER TAKEOFF FROM HNL, CREW NOTED LOSS OF SYSTEM A HYDRAULIC PRESSURE. CREW RETURNED TO HNL WITHOUT FURTHER INCIDENT. MAINTENANCE TOWED THE AIRCRAFT TO THE GATE AND REMOVED AND REPLACED THE LEFT MAIN LANDING GEAR HYDRAULIC SURGE RELIEF LSDR CA070707001Accumulator · separated(CAN) DURING TAXI-OUT, HYD 1 LO PRESS MESSAGE CAME ON. THE CREW REPORTED LOUD BANG FROM AFT PART OF CABIN. CREW EXECUTED RELEVANT ABNORMAL CHECKLISTS AND RETURNED TO RAMP. AFTER VERIFICATION BY THE MTCE CREW, THEY FOUND OUT THAT THE NR 2 HYDRAULIC ACCUMULATSDR HALA0700276Relay · malfunctionedETOPS SIGNIFICANT SYSTEM, EICAS MSG "C HYD SYS MAINT" DISPLAYED HYD PRESS NORMAL. REPLACED HYD GEN ADP CMD RELAY K865 & SYS 1 AIR/GROUND RELAY K1788 PERFORMED OPERATIONAL TEST PER M/M 29-11-00-715-896. OPS CKS NORMAL.SDR 2007FA0000699Shutoff Valve · jammedPILOT REPORTED RT ENGINE HYDRAULIC SHUTOFF VALVE WOULD NOT CLOSE FOLLOWING PREFLIGHT CHECKS. FOUND VALVE ASSY STUCK OPEN. REPLACED VALVE ASSY WITH NEW VALVE ASSY, OPERATIONS NORMAL. VALVE ASSY (PN 45AS65014003) HAVE NOTICED THESE VALVE ASSY TENDING TO FAIL SDR DL764070848Unknown · unknownDURING PREFLIGHT, RIGHT HYD .89, AFTER ENGINE START W/ FLAPS EXTENDED TO 5 RIGHT QTY DROPPED TO .66 THEN .61 W/ RF SIGN AT SAME TIME CENTER. HYD INCREASED TO 1.30, DRAINED C HYD SYS REFILLED R SYS TO FULL RAN BOTH ENGS OPERATED BRAKES, FLAPS COULD NOT DUPSDR 2007UALA02317Hydraulic System · malfunctionedLANDED UNDER AMBER ALERT DUE TO LOSS OF NR 4 HYDRAULIC SYSTEM PRESSURE. NORMAL LANDING AND TAXI TO GATE. [07-27-07] AFTER EXTENSIVE TROUBLE-SHOOTING, REPLACED NR 4 HYDRAULIC QUANTITY TRANSMITTER, PER FIM 29-30. SERVICED HYD TO FULL. AIRCRAFT RETURNED TO SDR CA070629002Packing · defective(CAN) WHILE REPLACING O-RINGS AND BACK-UP SEALS IN SOME HYDRAULIC ACTUATORS, FOUND SOME OF NEW BACK-UP SEALS DEFECTIVE. THE CHAMFERED EDGE OF THE SEAL IS TO SHORT WHICH IN TURN CAUSED THE EDGE TO DAMAGE THE O-RING. IT SEEMS TO ACT AS A KNIFE EDGE. ALL SEALS INSDR 2007UALA02313Hydraulic System · failedRTFL WITH BLUE SYSTEM HYDRAULICS FAILURE. FLT HAD IDENTICAL PROBLEM ON PREVIOUS LEG.SDR BA07008O-Ring · damagedFLIGHT 731, LGW-PHL: DURING CRUISE, GREEN HYDRAULIC SYSTEM QUANTITY BEGAN DROPPING. CAPTAIN DECLARED EMERGENCY INBOUND TO PHL. FLIGHT LANDED WITH NO DIFFICULTIES. MAINTENANCE REPLACED AN O-RING ON THE GREEN SYSTEM HIGH PRESSURE FILTER MODULE.SDR 2007UALA02269Elbow · crackedFLIGHT DIVERTED DUE TO A HYDRAULIC INDICATION PROBLEM. HYD LEAK ON NR 1 PYLON. FOUND CRACKED ELBOW MS21907W10, NON STOCK PART AVAILABLE AT BOEING. REPLACED ELBOW. SERVICED HYD SYSTEM. LEAK CHECK OK WITH ENG MOTORING, NO LEAKS NOTED. AIRCRAFT RETURNED TO SDR A6WA200740333Filter · failedAIRCRAFT FAILED HYDRAULIC SYSTEM TEST ON THE FIRST FLIGHT OF THE DAY CHECK. (NR2 SYSTEM) REMOVED AND REPLACED HYDRAULIC MANIFOLD NR 2, REF 29-11-05. (K)SDR 2007UALA02291Hydraulic Line · brokenAILERON MOVEMENT ON EICAS DOESN'T MATCH MOVEMENTS FROM CONTROL WHEEL. TURNING WHEEL TO LEFT GETS STIFF FROM 3 TO 6 DEG. ON INSPECTION FOUND NUT -LOOSE HARDWARE- IN RT LATERAL CONTROL OVERRIDE QUADRANT. PART REMOVED. NO DAMAGE NOTED TO CABLE OR QUADRANT. ASDR DL76G070823Valve · unknownAFTER PUSHBACK CTR HYD PRESS WOULD NOT RISE PAST 460 PSI. RTB, RESET HMG VALVE.SDR CHQA200700032O-Ring · leakingFLIGHT 6267 - SBN-CVG - DESCENDING 10000FT, OBSERVED HYD 1 LOW QTY EICAS MESSAGE. RAN QRH AND OBSERVED A DECREASE IN HYDRAULIC FLUID FOLLOWED BY A DECREASE IN HYDRAULIC PRESSURE. OBSERVED A COMPLETE LOSS OF ENGINE DRIVEN HYDRAULIC PRESSURE, ELECTRIC PUMP ON,SDR DXTA200702297Hydraulic System · failedDURING CRUISE AT FL480, THE B SIDE HYDRAULIC SYSTEM FAILED. AMBER CAS MESSAGE B PUMP FAIL, THE B QTY LOW, B PRESSURE DROPPED TO 0 PSI, QTY DROPPED TO 2 PERCENT, BTEMP AT 60 DEGREES. [07-13-07] FOUND RT ENGINE DRIVEN HYD PUMP FAILED INTERNALLY. REMOVED PUMSDR COMA0760452Hydraulic Line · failedFLIGHT 5298 - NR 1 HYD LOW PRESSURE CAUTION MESSAGE. HYD QTY FLUCTUATES BETWEEN 5 AND 30 PERCENT. AIRCRAFT RETURNED TO DSM AND LANDED SAFELY. REMOVED AND REPLACED NR 1 HYD SYS PRESSURE HOSE.SDR 2007FA0000552Hose · rupturedLT MLG IB GEAR DOOR ACTUATOR HYDRAULIC HOSE, HAD A PRESSURE FAILURE, THUS DRAINING HYDRAULIC FLUID IN FLIGHT, RESULTING IN FAILURE OF PROPER GEAR EXTENSION, EMERGENCY GEAR EXTENSION, AND CAUSING AIRCRAFT GEAR UP LANDING. HYDRAULIC HOSE P/N 17766-2 AND PIPER PSDR VNAA0706014Manifold · failedCREW REPORTED ON APPROACH A NOSE WHEEL STEERING INOP MESSAGE WAS DISPLAYED. CREW AS A PRECAUTION DECLARED AN EMERGENCY. CREW LANDED IN CLT WITHOUT INCIDENT AND WAS TOWED FROM THE TAXIWAY TO THE GATE. MAINTENANCE INSPECTED THE NOSE LANDING GEAR ASSEMBLY. MASDR HNAA0700120Flex Line · leakingNR 1 HYD QTY DROPPED TO 1.3, SYSTEM WENT INTO ISO, PRESSURE REMAINED GOOD AND FLUID DRIPPING FROM NR 2 NACELLE. INSTALLED TFL AT RT WING I/B SPOILER ACTUATOR ON REAR SPAR. REF MP&P VOL 2 20.1. LEAK CHECK GOOD. SERVICE HYD SYSTEM.SDR SWIA200718366O-Ring · leakingON TAXI OUT IN SLC, LOST ALL HYDRAULIC FLUID IN SYSTEM NR 2. RETURNED TO GATE. REPLACED O-RING ON PRESSURE SIDE OF MLG EMERGENCY EXTENSION VALVE. OPS AND LEAK CHECK GOOD.SDR 2007UALA02093Hydraulic System · leakingRTFL DUE TO HYDRAULIC QUANTITY LOSS ON CLIMBOUT. [07-06-07] FOUND RIGHT WING HYDRUALIC LINE GOING TO MAIN GEAR RETRACTING ACTUATOR LEAKING. REPLACED HYDRAULIC LINE.SDR CA070621002Motor · contaminated(CAN) DURING APPROACH, PILOTS SELECTED LANDING GEAR DOWN, GEAR MOTOR CIRCUIT BREAKER POPPED AND GEAR WOULD NOT EXTEND. AN EMERGENCY EXTENSION WAS CARRIED OUT SATISFACTORILY. AFTER RETURN TO BASE MECHANICS FOUND THAT THE HYDRAULIC MOTOR WAS CONTAMINATED WITH HSDR SIMA200717101Dump Valve · failedMAIN HYDRAULIC PRESSURE DROPS FROM 3000 PSI TO 2100 PSI WITHIN 35 SECONDS ON GROUND AND INFLIGHT. REMOVED AND REPLACED HYDRAULIC ACCUMULATOR PRESSURE DUMP VALVE IAW SAAB AMM. OPERATIONAL CHECK GOOD. RETURNED AIRCRAFT TO SERVICE.SDR HEEA115976Line · chafedDURING SHORT FINAL LANDING AT VK989, NR 1 HYDRAULIC LIGHT CAME ON. COMPLETED LANDING SAFELY ON DECK, SHUTDOWN. MAINTENANCE FOUND HYDRAULIC TUBE BELOW TAIL ROTOR GEARBOX TO HAVE A HOLE CHAFED IN IT. REPLACED TUBE ASSY.SDR 07FDEA02131Transmitter · malfunctionedLOST GREEN SYSTEM FLUID IN DESCENT. FOLLOWED ECAM PR OC AND QRH, GRAVITY EXTENDED THE GEAR PER QRH. AFTER PRESSURIZING GREEN HYD SYS DISCOVERED FLUID LEAKING FROM THE TOP OF THE GREEN SYS MANIFOLD AT THE PRESS XMITTER BASE. THE REST OF THE STORY: AFTER TALKSDR CA070614003Line · cracked(CAN) CREW NOTICED A LARGE PUDDLE OF HYDRAULIC FLUID COMING FROM THE NOSE WHEEL WELL AREA. DETERMINED TO BE A CRACKED LINE ON A BEND RADIUS, WHICH WAS THE SUPPLY LINE TO THE NWS SYSTEM. THE SYSTEM WAS DISABLED AND PLACED ON AN MEL DEFERRAL, CLEANED AND LEAK SDR F3LA200700130Line · wornFLIGHT CREW REPORTED YELLOW HYDRAULIC QUANTITY LOW. FOLLOWED HYD QTY LOW ECAM: PTU-OFF; ENG DRIVEN PUMP-OFF. YELLOW HYDRAULIC PUMP NEVER CAVITATED OR OVERHEATED. AN EMERGENCY WAS DECLARED AND AIRCRAFT LANDED WITHOUT INCIDENT AND WAS TOWED TO THE GATE. PERFSDR FDKA200706267Hydraulic System · lowFDM 6029 MCO-DAY (1839 PHX LCL). EMERGENCY DECLARED DUE TO ENGINE 1 HYDRAULIC PUMP FAILURE. MX OPS CHECKED THE PUMP WITH THE CREW RUNNING THE ENGINE. HYD SYSTEM 1 WAS LOW AND WAS SERVICED. NO FURTHER DEFECTS WERE NOTED AFTER THE OPS CHECK.SDR UPS07M49938Line · leakingINSPECTION TYPE:N/A EMERGENCY DECLARED - LOSS OF NR 2 HYD QTY. FOUND HYD PRESS LINE THAT RUNS TO NR 2 HYD MULE CONNECTION LEAKING. INSTALLED FLEX LINE, LEAK CHECK OK REF MD11 MM 20-10-01-2.SDR CA070607010Line · leaking(CAN) ON TRAINING FLIGHT RT HYDRAULIC QUANTITY REDUCED. HYDRAULIC LEAK FOUND IN RIGHT ENGINE PYLON AREA. HYDRAULIC SUPPLY PIPE FOUND LEAKING AT FLEXIBLE AREA, THIS FLEXIBLE AREA IS COVERED BY A RUBBER SHEATH. PEN INDICATES AREA FLUID WAS LEAKING FROM (TC NR 2SDR 2007FA0000626Valve · stickingPILOT REPORTED RT HYDRAULIC SHUTOFF VALVE INITIALLY STUCK DURING PREFLIGHT TEST, THEN OPENED. REPLACED VALVE WITH NEW UNIT, FUNCTIONAL TESTS, OK. REMOVED VALVE ASSY, PN 39045AS65014-003, MANUFACTURED 11/2005. (K)SDR 2007FA0000565Valve · leakingPERFORMED AN EMERGENCY LANDING DUE TO LOSS OF HYDRAULIC PRESSURE. THE EMERGENCY BOTTLE WAS USED TO LOWER THE GEAR AND LAND WITHOUT INCIDENT. THE CAUSE HAS BEEN DETERMINED TO BE THE HYDRAULIC LOADING VALVE (PN 4134-4, SN 781) FAILING IN CLOSED POSITION, RESULSDR UPS07M49890Filter Housing · crackedINSPECTION TYPE:N/A DIVERSION - AIRCRAFT DIVERTED TO KIX DUE TO NR 1 HYDRAULIC LOSS. *SUPPLEMENTAL SDR* FOUND CRACK ON HYD FILTER MODULE. REPLACED NR 1 ENG HYD FILTER MODULE PER MM 29-12-30 AND SERVICED HYD FLUID. LEAK CHECKS OK.SDR CA070606002Line · cracked(CAN) HYD LEAK IN RT WHEEL WELL. FOUND LINE CHAFED, LINE REPLACED AND AIRCRAFT RETURNED TO SERVICE AFTER SUCCESSFUL GEAR SWINGS CARRIED OUT. (TC NR 20070606002)SDR C2XA07RI042Tube · chafedFLT 2246 - EWR - CREW REPORTED HYD 1 LOW QTY AND E1 HYD PUMP FAIL ON EICAS. EWR MX FOUND PUMP RETURN TUBE ASSEMBLY CHAFED / LEAKING IN FUSELAGE AT FR 56. MX REPAIRED THE TUBE ASSY IAW EMB 145 AMM 20-10-03 AND PERFORMED OPERATIONAL CHECK SUCCESSFULLY. ACFT WSDR CHQA200700021Hydraulic Line · leakingFLIGHT 7780 - BOS-IAD - IN CLIMB-OUT AROUND 14,000 FEET, RECEIVED E1 HYD PUMP FAIL INDICATION AND SYS 1 HYD LOW QTY INDICATION. NR 1 ENGINE HYDRAULIC PUMP CAME ON, SYSTEM PRESSURE WAS MAINTAINED AT 2900 PSI, ON HYDRAULIC PAGE INDICATION OF QUANTITY WAS AT BOTSDR DXTA200702232Hydraulic System · lowIN CRUISE (HYD VOLUME LOW A (CAS) MESSAGE ILLUMINATED HYDRAULIC QUANTITY OF A SYSTEM INDICATED 5 PERCENT. WE FOLLOWED CHECKLIST AND BLEW DOWN LANDING GEAR AND USED EMERGENCY BRAKES AND STEERING UPON LANDING. [06-15-07] REMOVED AND REPLACED NOSE WHEEL STESDR SWIA200718302Hydraulic Line · leakingLOST GREEN SYSTEM HYDRAULIC FLUID. REPLACED BAD SECTION OF HYDRAULIC PRESSURE LINE IN LEFT OUTBOARD NACELLE. SERVICED HYDRAULIC FLUID TO PROPER LEVEL. OPS AND LEAK CHECKS ARE GOOD.SDR ANCF200700011Motor · inoperativeFLAPS FAIL TO MOVE, TRAILING EDGE LIGHT ILLUMINATED AND AICES MSG TE FLAPS DISAGREE AND FLAP ISLN VAL DISPLAYED. FLAPS OPERATE NORMAL USING TE ALTN SYSTEM. FLAP LEVEL VIBRATION WAS FELT DURING OPERATION WHEN TAXING OUT. IN ACCORDANCE WITH FIM 27-51-00 FIG 1SDR SWAA072690Hydraulic Line · chafedAIRTURN BACK / DECLARED EMERGENCY. THE -A- SYSTEM HYDRAULIC FLUID LOSS ON DEPARTURE FROM PHL. FOUND RIGHT MLG DOWNLOCK ACTUATOR LINE CHAFED. REMOVED AND REPLACED LINE PER MM.SDR 2007UALA01650Hydraulic System · unknownFLIGHT DIVERTED UNDER AMBER ALERT DUE TO LOW -A- SYSTEM HYDRAULIC PRESSURE PROBLEM. ON SUBSEQUENT FLIGHTS ON GEAR RETRACTION GOT MASTER CAUTION SIX PACK HYDRAULIC LIGHT WITH BOTH A-SYSTEM LOW PRESSURE LIGHTS ON. SYSTEM-A PRESSURE 3000+ AND QTY 84% AFTER GEARSDR 07FDEA01987Line · leakingON LANDING WITH MEDIUM AUTOBRAKES, LOST ALL GRN SYS HYD QTY GREEN HYD PUMPS WERE SHUT DOWN WITHIN 30 SECONDS. LARGE HYD LEAK SEEN ON RT LANDING GEAR. INVESTIGATING ORIGIN OF LEAK. LOCATED HYD LINE ON RT MLG AT TOP OF GEAR P/N A3241014500000 RUPTURED. REMOVSDR NWAA071949987Line · leakingAS THE AIRCRAFT CLIMBED AFTER DEPARTING DFW, THE CREW NOTICED THE LOSS OF FLUID QUANTITY AND PRESSURE FROM THE RIGHT HYDRAULIC SYSTEM. COM PROCEDURES WERE COMPLIED WITH AND THE AIRCRAFT CONTINUED TO SCHEDULED DESTINATION. AFTER LANDING UNEVENTFULLY THE LANDISDR TRBA2007026Line · brokenGREEN HYDRAULIC SYSTEM LO LEVEL INDICATION. REPLACED UNION ON LINE FROM BRAKE DUAL VALVE LINE TO BLUE ACCUMULATOR, OPS CHECK GOOD.SDR AALA20070889Hose · leakingORD INFLIGHT T681/19MAY - ON FIRST APPROACH AUTO SPEEDBRAKE INDICATION WHEN SPOILERS ARMED. RESET NO HELP. WHEN LANDING GEAR EXTENDED RIGHT MAIN LANDING GEAR UNSAFE INDICATION. INITIATED GO AROUND AND LOWERED LANDING GEAR MANUALLY. LANDED ORD WITHOUT INCIDSDR DLM88070573Module · unserviceableAFTER TAKEOFF PASSING THRU 8000 FT TURNED OFF RT ELEC PUMP AND AUX PUMP, LT HYD PRESS DROPPED TO ZERO AND QTY TO 1. C/W QRH CKLIST AND TURNED OFF LT ENG PUMP APPROX 2 MINS LATER. FOUND POP OUT IND HOUSING IN LT SYS PRESS MODULE OFF OF MODU REPLACED FILTER HOSDR FJT07058741Line · crackedENROUTE FROM THE CREW NOTICED HYD PRESSURE AT ZERO. CREW DIVERTED AND HAND PUMPED THE GEAR DOWN. THE ACFT LANDED WITHOUT FURTHER EVENT. MX REPLACED A CRACKED LINE IN THE RT FWD WING ROOT. ACFT FERRIED FOR GEAR SWINGS AND FUNCTIONAL CHECKS. ACFT RETURNED TSDR 07FDEA01818Line · failedAFTER TOUCHDOWN AMD SPOILER DEPLOYMENT, EXPERIENCED LOSS OF "A" HYDRAULIC SYSTEM QUANTITY AND PRESSURE. FOUND BLOWN FLEX LINE ON LT ELEVATOR PCU. PART IS IN STOCK AT SAV. REMOVED AND REPLACED I/B FLEX LINE PER MM27-30-081-4. SERVICED "A" HYD SYS TO FULL PE
Back to JASC 2910