JASC 3800

Service difficulty reports · 227

Reports filed under 3800 · Water and Waste System, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '3800'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR DXTA2016082106285Switch · shortON DECENT AND LANDING RED BAG FIRE LIGHT ILLUMINATED. TOWARDS REAR OF AFT CABIN, THERE IS AN ODOR OF WHAT MAY BE ELECTRICAL. WE SHUTDOWN THE ACFT POWER AND PULLED ALL CIRCUIT BREAKERS FOR AFT LAV. EVERYTHING UNDER THE LAV SINK WAS SOAKING WET. T/S SYSTEM RAug 21, 2016 · N896QS · Raythn HAWKER800XPSDR R61A201612190027Switch · corrodedDURING HEAVY CHECK, POTABLE WATER SERVICE PANEL SWITCH HARDWARE IS CORRODED. MAINTENANCE R & R POTABLE WATER SERVICE PANEL SWITCH HARDWARE IAW AMM 20-10-01 PN. PN NAS1801-08-10, SCREW.Dec 19, 2015 · N103HQ · Emb ERJ170200LRSDR WX0A20151125003Flange · corrodedNONEOct 22, 2015 · N228NV · Airbus A320214SDR CA150908005Housing · punctured(CAN) WAS UNABLE TO FILE A SDR ON LINE AS THE MANUFACTURER WAS NOT ON THE LIST. SYSTEM WOULD NOT ACCEPT ENTRY WITHOUT MANUFACTURER NAME.CREW REPORTED NO WATER ON 06JUL2015 AND DEFECT WAS DEFERRED. WHILE REPLACING THE WATER SYSTEM AIR COMPRESSOR (S/N 4269) TODAJul 6, 2015 · Boeing 73773ASDR CA150427014Compressor · failed(CAN) THE CREW REPORTED AN ELECTRICAL BURNING ODOR NEAR THE REAR OF THE ACFT. MAINTENANCE PERFORMED AN INSPECTION AND FOUND THE POTABLE WATER COMPRESSOR NOT FUNCTIONING AND THE CAUSE OF THE ODOR.Apr 26, 2015 · Boeing 73776NSDR UHLA2015032000285Fitting · corrodedDURING INSPECTION, THE TOILET WASTE VALVE WAS FOUND TO BE CORRODED AROUND THE FITTING. THE FITTING WAS REPLACED IAW AMM 38-32-04 AND SRM 51-40-02.Mar 20, 2015 · N265SK · Emb EMB145SDR CA140123009Line · leaking(CAN) DURING TAKEOFF AFTER ROTATION THE FLIGHT CREW REPORTED AN AUTO FAIL LIGHT ILLUMINATE ON THE PRESSURIZATION PANEL. FOLLOWING PROCEDURES, THE FLIGHT CREW SWITCHED TO ALTERNATE MODE WHICH ALSO FAILED. THE FLIGHT CREW THEN SWITCHED TO MM & WERE SUCCESSFUL Jan 22, 2014 · Boeing 7377*SDR R61A201311181224Spigot · corrodedDURING HEAVY CHECK, AFT GALLEY WATER SPIGOT CORRODED. MX R & R AFT GALLEY WATER SPIGOT IAW AMM 20-10-01. PN 90043-407, SPIGOT ASSY. ACFT REMAINS UNTIL HEAVY CHECK IS COMPLETED.Nov 18, 2013 · N122HQ · Emb ERJ170200LRSDR CALA2013080690176Hose · crackedFOUND ICE BUILD UP INSIDE WING TO BODY FAIRINGS ABOVE FWD DRAIN MAST. REPLACED CRACKED HOSE ATTACHED TO FWD DRAIN MAST. LEAK CHECKED OK, MAST HEATER TESTED OK.Aug 5, 2013 · N210UA · Boeing 777222SDR UALA2013071504950Drain Line · brokenAFT LT GALLEY DRAIN LINE BROKEN, AFT LEFT GALLEY WATER SUPPLY INOPERATIVE.Jul 14, 2013 · N661UA · Boeing 767322SDR UALA2013071504913Valve · malfunctionedNO WATER PRESSURE ALL AREAS. FOUND WATER FILL SELECT VALVE NOT FULLY CLOSED. CYCLED VALVE TO CLOSED POSITION, WATER PRESSURE NOW OK.Jul 12, 2013 · N220UA · Boeing 777222SDR UALA2013070904771Drain Line · cloggedCREW LAVATORY SINK DRAIN INOPERATIVE. FOUND LAVATORY WATER SHUTOFF VALVE UNDER SINK IS LETTING WATER BY, CAUSING INBOUND CLOG. F/A PEELED BACK CLEAR TAPE TO LET WATER DRIP INTO SINK. ON ARRIVAL, SINK WAS HALF FULL WATER AS SINK DRAIN LINE FOUND CLOGGED.Jul 8, 2013 · N416UA · Airbus A320232SDR UALA2013070104579Control Unit · faultyAFT CABIN, LAVATORY TOILET WILL NOT FLUSH. AFT LAV VACUUM SYS IS INOP ON GROUND. WATER ENTERS BOWL NORMALLY WHEN FLUSHED. LAV FCU IS NOT TURNING ON VACUUM. VERIFIED WHEN OTHER LAV FLUSHES THIS LAV WILL FLUSH.Jun 29, 2013 · N429UA · Airbus A320232SDR UALA2013053103810Transmitter · failedACRID ODOR IN AFT GALLEY, FLT DIVERTED. ADJUSTED COMPRESSOR INTER LOCK SWITCH AFTER COMPRESSOR REPLACED, ADJUSTED WATER FILL AND VENT VALVE CABLE ASSY. PRESSURISED POTABLE WATER SYSTEM, ALL OPS NORMALMay 30, 2013 · N667UA · Boeing 767322SDR UALA2013052203536Faucet · damagedPOTABLE WATER SYS INOPERATIVE. REPLACED FWD LAVATORY FAUCET.May 21, 2013 · N569UA · Boeing 757222SDR UALA2013052003466Unknown · leakingAFT GALLEY HAS CONTINUOUS WATER LEAK FROM CEILING. FOUND WATER CONTAMINATION UNDERNEATH CHILLER C52 SHROUD PAN. OPERATED CHILLER C52 AND FOUND NO LEAKS. ALSO VERIFIED DRAIN PAN & HOSE CONNECTED AND SECURE.May 19, 2013 · N178UA · Boeing 747422SDR CA140613002Drain Valve · failed(CAN) THE AUTOMATIC DRAIN VALVE, INSTALLED IN THE LOWER GALLEY OF CL-605, A/C FAILED ALLOWING WATER TO LEAK OUT OF ITS VENT HOLE AND INTO THE GALLEY AND UNDER THE FLOOR INTO THE AVIONICS BAY AND SOAKED THE INSULATION BLANKETS INSTALLED BETWEEN FS 280R AND FS 3May 10, 2013 · Cndair CL6002B16SDR UALA2013042202769Unknown · leakingCREW REPORT: F/A REPORTS AFT GALLEY CARPET SOAKED WITH WATER. POSSIBLY FROM FWD AFT LAV FOUND WATER LINE GOING TO FLUSH VALVE CRACKED AND LEAKING. INOP WATER TO TOILET WILL BE A DRY FLUSH. REF IPC 38-31-41-30C ITEM 80 2-012N602-70 ITEM 130 3-906E515-80 ITEMApr 20, 2013 · N404UA · Airbus A320232SDR UIEA2013041900247Bracket · looseLAVATORY E WASTE COMP DOOR CABLE BRACKET RIVETS LOOSE AND PULLED THROUGH. R & R 2 LOOSE RIVETS SECURING BRACKET IN PLACE REF SRM 51-40-02.Apr 18, 2013 · N642GT · Boeing 7673Y0SDR UALA2013032201784Unknown · unknownLAVATORY AND POTABLE WATER ISSUE, FLIGHT DIVERTED.Mar 21, 2013 · N543UA · Boeing 757222SDR AMCR2013032202Fitting · crackedWHEN TROUBLESHOOTING AN INOP CHECKLIST MGMT SYS, PULLED FLOORBOARD IN FORWARD CABIN TO ACCESS THE CHECKLIST BOX AND FOUND BOX TO BE WET, AND ABOUT 3.5 GALLONS OF WATER IN THE FORWARD SECTION OF THE FUSELAGE BELLY, WHERE NO FUSELAGE DRAINS ARE INSTALLED. ALSOMar 20, 2013 · N716DV · Cessna 525CSDR UALA2013022001041Unknown · inoperativeLAV SYSTEM INOP, FLIGHT DIVERTED.Feb 19, 2013 · N827UA · Airbus A319131SDR UALA2013021400870Compressor · leakingWATER LEAK IN AFT BELLY AREA. WATER LEAKING FROM BELLY DRAIN LOCATED BELOW AFT CARGO DOOR. DRAINED WATER TANK, WATER STILL DRAINING FROM BELLY BUT AT SLOWER RATE. SERVICED WATER TO THREE QUARTER FILL. DURING THE SERVICE PROCESS THE VOLUME OF WATER COMING FFeb 13, 2013 · N552UA · Boeing 757222SDR UALA2013010300025Line · leakingWATER GUSHING FROM BELLY OF ACFT. SUSPECT RUPTURED WATER LINE. TROUBLESHOOTING FOUND RUPTURED WATER LINE IN CABIN FLOOR AT ROW 12ABC AND 20ABC. REPLACED WATER LINE REF AMM 20-23-38-300-002-A. PRESSURE CHECKED LINE AND NO LEAKS FOUND.Jan 3, 2013 · N837UA · Airbus A319131SDR CA121105026Sink · smoke(CAN) FLIGHT ATTENDANTS NOTICED SMOKE COMING OUT OF THE SINK IN THE LAV, AFTER PUSH. FLIGHT RETURNED TO THE GATE FOR INSPECTION AND WAS CLEARED BY MTC. ON RETURN ACA303, FLIGHT ATTENDANTS FELT NAUSEOUS, AND COMPLAINED ABOUT CONDITIONS. ONE OF THE F/A`S BOOKED Nov 5, 2012 · Emb ERJ190100IGWSDR UALA2012101005775Compressor · noisyCLICKING SOUND COMING FROM UNDER THE AFT GALLEY FLOOR. NOISE STOPS WHEN P6 K21 CIRCUIT BREAKER IS OPENED. REPLACED COMPRESSOR.Oct 9, 2012 · N554UA · Boeing 757222SDR REXA2012073001212Drain · kinkedTOILET SMOKE CAUTION MESSAGE IN FLIGHT. PERFORMED QRH. SWEET ODOR ASSOCIATED WITH IT. DETECTOR WENT OFF. FLIGHT ATTENDANT REPORTED SMOKE, BUT IT DISSIPATED VERY QUICKLY. REPORTED NO PROBLEMS AND RESET SMOKE DETECTOR ALARM. SEVEN MINUTES LATER ALARM WENT Jul 30, 2012 · N8390A · Cndair CL6002B19SDR CA120509010Wastegate Valve · leaking(CAN) WASTEGATE FOUND LEAKING. WASTEGATE REPLACED.Apr 17, 2012 · Piper PA31SDR UALA2012040902155Control Panel · inoperativeWATER INDICATOR INOPERATIVE ON CSCP. WATER MUST BE SERVICED TO FULL. REPLACED CSCP, WATER INDICATION IS OKAY.Apr 6, 2012 · N210UA · Boeing 777222SDR UALA2012020800765Line · leakingWATER LEAKING FROM THE BELLY OF FUSELAGE UNDER THE AFT CARGO PIT. COMPLIED WITH MEL 3810W, ONLY TO REVERSE MEL PROCEDURE AFTER LINE REPLACED. NEW LINE INSTALLED AND LEAK CHECK GOOD.Feb 7, 2012 · N171UA · Boeing 747422SDR UALA2012011600329Drain Valve · defectiveON ARRIVAL CHECK FOUND WATER LEAKING UNDER FUSELAGE OF FWD CARGO AND AFT CARGO PIT, CHK'D FOUND FWD PIT STA 800 DRAIN TUBE BROKEN, AFT STA 1580 DRAIN TUBE END COUPLING DAMAGE. FOUND DOOR 1R LAV, DOOR 2 L AND 2R LAVS DRAIN VALVE IN DRAIN POSITION, PUT ALL THREJan 13, 2012 · N796UA · Boeing 777222SDR UALA2012010300038Cap · misalignedWATER LEAKING FROM NON DRAIN PORTS ABEAM ADP EXHAUST. FOUND WATER LINE END CAP MISALIGNED AT STA 1600 RT WALL IN THE AFT CARGO COMPARTMENT. REPOSITIONED END CAP AND PRESSURIZED THE WATER SYSTEM, NO MORE LEAKS FOUND.Jan 3, 2012 · N785UA · Boeing 777222SDR UALA2011082904639Valve · openNO WATER PRESSURE, FLIGHT DIVERTED. FOUND OVERFLOW VALVE OPEN ON ARRIVAL. CYCLED VALVE MANUALLY AND FROM SERVICE PANEL. ALL OP'S NOW NORMAL.Aug 28, 2011 · N447UA · Airbus A320232SDR UALA2011021800847Packing · leakingRAN OUT OF WATER 9 HRS INTO FLIGHT. QTY WAS FULL BEFORE DEPARTURE. SERVICED WATER TO 95 PERCENT FULL THEN CHECK. NO LEAK FOUND ON GROUND. WATER SOV SWITCH OFF AND M41, 42 COFFEEMAKER DEACTIVATED. DEFER IAW MEL. REPLACED PACKING. OPS CHECKED OK. NO LEAK FFeb 18, 2011 · N175UA · Boeing 747422SDR DXTA2011020404450Fillercap · looseTHUMPING NOISE COMING FROM LAV IN FLIGHT. ON POST FLT FOUND FILLER CAP LOOSE. FOUND LAV FLUID SERVICING PORT CAP NOT LOCKING INTO SECURE POSITION. LUBED FILTER CAP BEARINGS AND RESECURED CAP IAW MM 38-30-02. OPS CHECKED GOOD.Feb 3, 2011 · N669QS · Cessna 560XLSDR UALA2011011000132Drain · cloggedICE FOUND IN THE LOWER E/E AND NOSE TUNNEL BILGE AREA. GRAY WATER HAS BEEN SUCTIONED OUT AND DRIED. ALSO, DRAIN LINE HAS BEEN UNCLOGGED.Jan 8, 2011 · N548UA · Boeing 757222SDR UALA2010122104662Waste Tank · missingLOST WASTE TANKS, FLIGHT DIVERTED. LOST WASTE TANKS 1 AND 2 IN FLIGHT, CYCLED LAV SYS 1 AND LAV SYS 2 CB'S PER SAMC. NO HELP. DOWN TO 3 LAVS OF WASTE TANK 1. NO FURTHER MAINTENANCE ACTION NEEDED PER OPBLM. SERVICED ALL 3 LAVS AND OPERATION IS NORMAL.Dec 21, 2010 · N787UA · Boeing 777222SDR UALA2010031500858Valve · closedNO WATER IN FWD MID-LAVS, FLIGHT DIVERTED. UPON ARRIVAL ALL FC AND BC GALLEY AND SINK DRAINS FULL AND NOTHING DRAINING OUT OF DRAIN MAST. LT RMM FOUND CABLE ON GRAY WATER DRAIN RESTRICTOR VALVE UNATTACHED, ALLOWING VALVE TO REMAIN IN THE CLOSED POSITION. PEMar 14, 2010 · N768UA · Boeing 777222SDR UALA2010020900507Lavatory · fullLAV ISSUE, FLT DIVERTED. LAVS HIGH BUT NOT OVERFLOWING. RESERVICED LAVS, ALL OPS CHECK NORMAL.Feb 9, 2010 · N537UA · Boeing 757222SDR CA100119007Hose · misinstalled(CAN) THIS PART WAS INSTALLED IN A LOCATION WHICH IS PROHIBITED BY AD 2008-17-13. THE PART WAS ORDERED USING THE CURRENT MFG ILLUSTRATED PARTS CATALOGUE (IPC) APPLICABLE TO THIS ACFT. MY CONCERN IS WHY HAS MFG NOT AMMENDED THEIR IPC TO INDICATE THAT THIS PART Dec 29, 2009SDR NSVA2009054Plate · corrodedLAV DOOR AND SURROUNDING LAV SERVICE CONNECTOR/PLATE CORROSION PLUS 5 CHERRY FASTENERS INSTALLED RT TOP/BOTTOM CORNERS. SRM REPAIR / REPLACEMENT OF RECEPTACLE IAW 51-40-22.Oct 30, 2009 · N311CE · Saab 340BSDR UALA2009100503130Tank · emptyCREW REPORTS NO WATER PRESSURE UPON TAKEOFF. FOUND WATER TANK GAUGE READING 000 PERCENT QTY, SERVICED TANK TO OVERFILL, FOUND NO LEAKS. A/C OKAY FOR SERVICE.Oct 5, 2009 · N118UA · Boeing 747422SDR HALA2009080500350Tank · emptyACFT DIVERTED, DUE TO THE LOSS OF WATER PRESSURE. FOUND ON ARRIVAL H2O TANK EMPTY. SERVICED TO FULL, NO LEAKS NOTED. PRESSURE CHECKED GOOD. OK FOR SERVICE.Aug 5, 2009 · N587HA · Boeing 76733ASDR CALA2009072000376Line · brokenWATER COMING OUT OF AFT CARGO PIT BELLY DRAINS. REMOVED AND REPLACED WATER LINE, FOUND BRACKETS (212N3042Y3) SUPPORTING APU BLEED LINE BROKEN CAUSING LINE TO BREAK WATER LINE (AS4796-12-0282).Jul 17, 2009 · N57857 · Boeing 757324SDR UALA2009041301054Valve · malfunctionedWATER PRESSURE ISSUE. RTFL. FOUND WATER TANK FULL AND FILL VALVE CLOSED. CREW REPORT, THERE WAS WATER PRESS ON GROUND, BUT NONE AFTER DEPARTURE. TANK DRAINED. LAV AND GALLEY DRAINS NOT AFFECTED. TRIED TO PRESSURIZE WITH ENGINES AND APU AIR, NO JOY. WATEApr 12, 2009 · N458UA · Airbus A320232SDR DL76L090660Drain Mast · damagedON ARRIVAL FOUND AFT DRAIN MAST DAMAGED AND WITH ONE ATTACHMENT BOLT SHEARED ANDTHE REMAINING TWO WITH DAMAGED INSERTS DUE TO IMPACT.Apr 10, 2009 · N1201P · Boeing 767332SDR UALA2009012600282Timer · faultyTWO LAVATORIES INOPERATIVE. FLIGHT DIVERTED. LAV FWD OF 3L FLUSH MOTOR FAILED NOW ONLY 2 WORKING LAVS. TROUBLESHOT ITEM. SUSPECT FLUSH SWITCH INOP. REPLACED TOILET FLUSHING TIMER, OPS CHECKS NORMAL.Jan 25, 2009 · N572UA · Boeing 757222SDR 2008UALA06307Water System · malfunctionedLOSS OF ALL WATER PRESSURE. FLIGHT DIVERTED.Oct 29, 2008 · N777UA · Boeing 777222SDR 2008UALA03712Unknown · unknownWATER SYSTEM PROBLEM. RTFL.Jul 7, 2008 · N653UA · Boeing 767322SDR 2008UALA03710Unknown · unknownRUNNING OUT OF WATER AND LAVS SHUTTING DOWN. FLIGHT DIVERTED.Jul 5, 2008 · N218UA · Boeing 777222
Back to JASC 3800