SDR SWIA201230792Drain Mast · overheatedAFT POTABLE WATER DRAIN MAST WAS OVERHEATING AND CAUSING BURNING SMELL AROUND CARGO AREA. (FLT 6407) REPLACED AFT POTABLE WATER DRAIN MAST IN REFERENCE TO AMM.May 16, 2012 · N919SW · Cndair CL6002B19SDR UALA2012043002558Line · damagedPOTABLE WATER SUPPLY LINE RUNNING FROM STA 1375 TO 1550 HAS A BURN MARK ASSOCIATED WITH RIBBON HEATER TAPE B110 AT BS 1420. REMOVED AND REPLACED DAMAGED WATER LINE IAW AMM 38-10-00 AND SRM 51-40-02. PERFORMED LEAK CHECK TEST IAW 38-10-00. CHECKED GOOD. HEAApr 27, 2012 · N644UA · Boeing 767322SDR UALA2012042402456Valve · shortedPOTABLE WATER DRAIN WILL NOT CLOSE REF DF0790. REPLACED FWD WATER DUMP VALVE ACTUATOR. DURING OPS CHECK VALVE FAILED TO CLOSE AND WATER SYSTEM DRAIN CIRCUIT BREAKER LOCATED IN AFT GALLEY CEILING POPS REPEATEDLY. FOUND NEW VALVE SHORTED INSIDE, REPLACED FWD Apr 23, 2012 · N468UA · Airbus A320232SDR USAA2012042300046Water Heater · faultyFLIGHT ATTENDANTS REPORTED ELECTRICAL AND GAS SMELL NEAR DOORS 3L/R AND AFT RIGHT LAV. PASSENGERS PAX REPORTED SAME SMELL IN THE SAME AREA. MAINTENANCE FOUND SOURCE TO BE LAV 'E' WATER HEATER - REMOVED AND REPLACED WATER HEATER IAW AIRBUS MAINTENANCE MANUAL Apr 22, 2012 · N535UW · Airbus A321231SDR UALA2012041502275Potable Water · contaminatedWATER IN ENTIRE ACFT HAS FOUL ODOR AFFECTING TEA AND COFFEE BADLY. SERVICED WATER SYSTEM TWICE AND FLUSHED LINES IN INTERIOR OUT. WATER TASTES GOOD.Apr 13, 2012 · N502UA · Boeing 757222SDR CA120330005Tank · ruptured(CAN) ACFT RETURNED TO BLOCK AFTER A LOUD BANG HEARD IN CLIMB FOLLOWED BY WATER QTY AND PRESSURE INDICATE ZERO ON FAP PANEL. ON ARRIVAL, FOUND WATER TANK RUPTURED.Mar 27, 2012 · Airbus A310304SDR UALA2012032301866Tank · unknownPOTABLE WATER SMELLS LIKE OIL IN SEVERAL POTS OF BREWED COFFEE. DRAINED AND SVC WATER TANK PER AMM. NOTE -- NO ODOR IN WATER AS DRAINING FROM TANK.Mar 22, 2012 · N673UA · Boeing 767322SDR UALA2012031901760Packing · leakingDEPARTED LAX WITH WATER AT 100 PERCENT. 2HR INTO FLT WATER AT 0 AND ONLY AIR FROM FAUCET - TANK DRAINED INTO BELLY OF FWD CARGO PIT PAST WATER OUTLET PLUMBING PACKINGS. REPLACED PACKINGS REF IPC 38-11-03. SERVICED WITH WATER BEYOND ONE QUARTER TANK CAPACITYMar 16, 2012 · N422UA · Airbus A320232SDR UALA2012030501398Compressor · faultyAFTER CLIMBOUT CREW STATED NO WATER FROM THE LAV FAUCETS AND HAD VIBRATION. CREW REPORTS POTABLE WATER SYSTEM DRAINED TO EMPTY IN FLIGHT. FOUND LARGE BLOCK OF ICE AT WATER SERVICE PNL. SUSPECT OVERHEAT OF WATER HEATERS AND WATER COMPRESSOR BASED ON CREW COMMar 5, 2012 · N570UA · Boeing 757222SDR UALA2012022401119Line · burnedSUPPLY LINE FOR POTABLE WATER BURNED AT STATION 790. REPLACED THE B234 SUPPLY LINE AT STA 790.Feb 24, 2012 · N641UA · Boeing 767322SDR UALA2012022301099Line · burnedPOTABLE WATER SUPPLY LINE HAS BURN DAMAGE AT STA 1495. RMV'D & RPLC'D POTABLE WATER SUPPLY LINE.Feb 23, 2012 · N641UA · Boeing 767322SDR CALA2012021300096Line · loosePOTABLE WATER QTY WENT TO ZERO DURING FLIGHT FOUND LOOSE POTABLE WATER SUPPLY LINE AT STA 825 LT. REPLACED O-RING, SECURED LINE. LEAK CHECKS GOOD.Feb 12, 2012 · N78004 · Boeing 777224SDR UALA2012020600722Valve · faultyFOUND AFT GALLEY WATER SHUT OFF UNABLE TO STOP WATER FLOW. NEW VALVE REF IPC 25-30-00B-001A ITEM 55, VALVE PN (#641-1090). TIGHTENED SET SCREW ON KNOB. OPS CHECKS OKAY.Feb 6, 2012 · N523UA · Boeing 757222SDR UALA2012012700561Heater · leakingWATER LEAK, FLIGHT DIVERTED. CREW REPORT HEAVY WATER LEAK FROM UPPER DECK TO FIRST CLASS AREA. CARPETS HAVE STANDING WATER. FOUND WATER HEATER PRESSURE VALVE LEAKING. RPLC'D HEATER PER MM.Jan 27, 2012 · N107UA · Boeing 747422SDR UALA2012011100251Potable Water · contaminatedPOTABLE WATER CONTAMINATED. A STRONG CHEMICAL TASTE AND ODOR. FLUSHED WATER SYS. VERIFIED WATER TASTE WITH CREW OK.Jan 11, 2012 · N180UA · Boeing 747422SDR UALA2011122307077Line · damagedWATER SUPPLY TUBING AT STA 1087 TO STA 808 IS DAMAGED BY ARCING HEATER TAPES. REPLACED DAMAGED WATER SUPPLY LINE BETWEEN STA 808 AND 1087 IAW GNMM, LEAK CHECKS GOOD.Dec 22, 2011 · N643UA · Boeing 767322SDR ZKFR201112223218ACheck Valve · faultyPOTABLE WATER IN LAV HAS LOW PRESSURE AND PUMP CONTINUOUSLY CYCLES. R & R DRAIN CHECK VALVE. OPS CHECKED GOOD. INSPECTED CHECK VALVE ON BENCH AND FOUND VALVE NOT COMPLETELY CLOSING AND REQUIRING EXCESSIVE PRESSURE TO CLOSE AT ALL.Dec 22, 2011 · N78KN · Hawbee 4000SDR UALA2011122107004Cartridge · defectiveCREW REPORTED THAT 2R AFT LAV COLD WATER DOES NOT SHUTOFF. REPLACED COLD WATER CARTRIDGE.Dec 19, 2011 · N214UA · Boeing 777222SDR UALA2011121606911Coupling · defectiveLARGE WATER LEAK IN CTR OF CABIN BEHIND DOOR 3 BULKHEAD. SAMC TEXT: FLIGHT LOST ALL WATER PRESS AND QTY ALL LAVS DRY. LOCATE AND RPR SOURCE OF LEAK. CHECK BELOW DECK FOR WATER DMG, CLEANUP PER GENERAL PROCESSES MANUAL (GPM) 4-0-6-004 SAMC. FOUND WATER SUPDec 16, 2011 · N223UA · Boeing 777222SDR UALA2011113006577Hose · leakingCREW REPORT: RUNNING WATER LEAK INSIDE LAV 105 REF DF872 WATER SOV SHOULD ALREADY BE IN OFF POSITION. SAMC TEXT: F/O CONFIRMED SOV IS IN THE OFF POSN, WATER STILL LEAKING. MAINT PLZ DEBRIEF FLT CREW UPON LANDING. :REF PTT 5432015 AND 5432016 FOR HOSES REPNov 30, 2011 · N122UA · Boeing 747422SDR UALA2011111806330Cap · looseUPON ARR FOUND WATER LEAK FROM AFT CARGO AREA. FOUND END CAP LOOSE AT PORTABLE WATER LINE INSIDE RT SIDE WALL IN AFT CARGO. SECURED SAME. NO LEAK FOUND.Nov 18, 2011 · N785UA · Boeing 777222SDR R61A20110364Spigot · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND AFT GALLEY WATER FAUCET CORRODED. MX REMOVED AND REPLACED SPIGOT AT AFT GALLEY IAW EMB 175 AMM 20-10-03. A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION. P/N 90043-407Nov 8, 2011 · N118HQ · Emb ERJ170200LRSDR R61A20110190Flange · corrodedWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE REPORTED POTABLE WATER TANK FILL BOX FLANGE HAS CORROSION. MAINTENANCE REMOVED AND REPLACED WATER TANK FILL BOX FLANGE IAW EMB SRM 51-43-02. THE AIRCRAFT WAS RETURNED TO SERVICE 7-23-11.Jul 23, 2011 · N109HQ · Emb ERJ170100SUSDR USAA2011072100004Water Heater · defectiveABOUT 2 HOURS INTO FLIGHT, ATTENDANT SMELLED ELECTRICAL WIRES IN LAV 'E'. HOT WATER HEATER WAS SHUT OFF AND SMELL DISSIPATED. MAINTENANCE REMOVED AND REPLACED THE LAV 'E' WATER HEATER IAW AIRBUS MAINTENANCE MANUAL 38-12-16.Jul 17, 2011 · N620AW · Airbus A320231SDR USAA20110620SB105O-Ring · damagedTPA - EN ROUTE CLT TO FLL, DURING CRUISE, A MASSIVE WATER LEAK WAS REPORTED IN THE AFT GALLEY. WATER TANK QUANTITY WENT FROM FULL TO LESS THAN ONE QUARTER TANK IN A SHORT TIME, FLOODING THE AFT GALLEY. ESTIMATE 15 GALLONS PLUS DRAINING ONTO FLOOR. FLIGHT DIJun 18, 2011 · N532AU · Boeing 7373B7SDR UALA2011061502949Motor · malfunctionedWATER SYSTEM C-B AT 2001VU POPPING. FOUND DRAIN VALVE 14MP POPPING C-B AND OVERFILL VALVE DRIVING OPEN 8MP. WITH CONNECTOR REMOVED C-B STAYS CLOSED. CONNECTOR REMOVED, CAPED AND TYED BACK. WILL NEED TO BE MANUAL FILL. VALVES LOCATED IN FWD PIT BEHIND RT AFTJun 13, 2011 · N402UA · Airbus A320232SDR UALA2011061302871Unknown · malfunctionedPOTABLE WATER SYS PRESSURE DOES NOT MAINTAIN HEAD PRESSURE AS IT SHOULD AFTER BLEEDS HAVE BEEN SHUT DOWN. CHECKED OVERFLOW MANUAL VALVE AND FILL VALVES AND NO LEAKS NOTED. NO WATER LEAKS NOTED IN SYS EITHER. SYS OPERATES FINE WITH BLEED. NO PROBLEMS NOTED Jun 11, 2011 · N823UA · Airbus A319131SDR DALA1137473233Water Heater · odorON DESCENT APPROXIMATELY 20000 FEET, FLIGHT ATTENDANT CALLED WITH A SLIGHT SMOKEY SMELL IN AFT GALLEY AREA. PILOT IN JUMP SEAT CONFIRMED SLIGHT SMELL, GALLEY POWER WAS TURNED OFF FOR REMAINDER OF FLIGHT AND LANDING WAS UNEVENTFUL. REPLACED RIGHT AFT LAVATORYJun 1, 2011 · N333NW · Airbus A320211SDR UALA2011032501416Transmitter · faultyPOTABLE WATER SYSTEM SERVICED TO FULL, BUT INDICATIONS SHOW 3 QTR. SERVICED TO FULL, INDICATIONS INOP IN CABIN AND SERVICE PANEL. WHEN CLEARING DEFER ITEM REMOVE DF-CF PLACARD FROM INTERIOR OF BOTH POTABLE WATER SERVICE PANEL. ALL QTY INDICATORS SHOWS 3 QTR,Mar 24, 2011 · N782UA · Boeing 777222SDR UALA2011031601272Connector · leakingAFT GALLEY FLOOR SOAKED BY WATER FROM BEHIND AFT GALLEY CARTS. FOUND CONNECTOR FROM AIRCRAFT TO COFFEEMAKER M40 LEAKING. INOPED AFT GALLEY WATER AND OPENED ASSOCIATED COFFEEMAKER CB(S). NO FURTHER LEAKS NOTED. NEEDS WATER COUPLING THAT ATTACHES TO THE RAILMar 14, 2011 · N580UA · Boeing 75721BSDR DALA1112699006Water Heater · odorIN-FLIGHT PERSONNEL STATED THAT RIGHT AFT LAVATORY SMOKE DETECTOR WENT OFF. SMELL APPEARED TO BE COMING FROM HOT WATER HEATER. MAINTENANCE INSPECTED HEATER. NO EVIDENCE OF OVERHEAT. AIRCRAFT IS OKAY FOR SERVICE.Feb 21, 2011 · N906DE · Doug MD88SDR UIEA2011021100060Compressor · smokeDURING OFFLOAD, LOADMASTER NOTED SMOKE COMING OUT OF THE RT SIDE VENT AT STA 850. ISOLATED SMOKE TO POTABLE WATER COMPRESSOR, INSPECTED GENERAL AREA AND NO ABNORMALITIES FOUND. POTABLE WATER COMPRESSOR INOPERATIVE AND POTABLE WATER SYS DEACTIVATED.Feb 11, 2011 · N496MC · Boeing 74747UFSDR UALA2011021000698Valve · stuckNO WATER PRESSURE, FLIGHT DIVERTED. SUPPLEMENTAL DATA UPDATE THIS FIRST REVENUE FLT SINCE ACFT IN FOR PAINT SCHEME. WATER SYSTEM WAS DRAINED DURING PAINT VISIT. PLEASE CHECK FWD AND AFT FILL VALVES FOR CORRECT CLOSURE. FREED OVERFLOW VALVE, OPS GOOD.Feb 9, 2011 · N211UA · Boeing 777222SDR UALA2011011800292Valve · faultyCREW REPORTS NO WATER PRESSURE THROUGHOUT ACFT. POTABLE WATER FILL VALVE LEAKING AIR IN CLOSED POSITION. CONTROL ROD DISCONNECTED FROM VALVE. REPLACED BORROWED WATER FILL VALVE IN AFT PIT, NO HELP. FOUND WATER SYS AIR COMPRESSOR INOP. REPLACED POTABLE WATJan 17, 2011 · N649UA · Boeing 767322SDR C2XA10IA321Heater · malfunctionedCAE - FLIGHT 2622, DURING PREFLIGHT INSPECTION THE CREW REPORTED A BURNING SMELL COMING FROM THE LAV SINK. MAINTENANCE INSPECTED THE AIRCRAFT AND PLACED THE DRAIN HEATER ON MEL, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. MAINTENANCE RESET THE DRAINDec 6, 2010 · N11199 · Emb EMB145XRSDR AMCR201011Thermostat · separated"LAVATORY WATER" CIRCUIT BREAKER POPPED. FOUND WATER HEATER TO BE AT FAULT. REMOVED PLASTIC COVER ON HEATER AND FOUND THERMOSTAT BODY HAD SEPARATED (POOR SOLDER JOINT) WHICH EXPOSED THE CONTACTS AND SHORTED OUT THE UNIT. HEATER MFG MAY 2008.Nov 23, 2010 · N526AC · Bombdr BD1001A10SDR DALA1027010626Water Heater · malfunctionedAN ELECTRICAL SMELL OCCURRED IN THE FORWARD LAVATORY. THE HOT WATER HEATER WAS TURNED OFF IN FLIGHT. FLIGHT CONTINUED TO BOS AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE HOT WATER HEATER PER MM 38-13-51. (2010-D1238) (DL757102772)Oct 13, 2010 · N626DL · Boeing 757232SDR DALA1026700626Water Heater · malfunctionedAN ELECTRICAL SMELL OCCURRED IN THE FORWARD LAVATORY. THE HOT WATER HEATER WAS TURNED OFF IN FLIGHT. FLIGHT CONTINUED TO BOS AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE HOT WATER HEATER PER MM 38-13-51. (2010-D1238)Oct 13, 2010 · N626DL · Boeing 757232SDR CA101001002Compressor · failedLAVATORY-E WAS REPORTED TO HAVE WATER CONTINUOUSLY RUNNING FROM THE SINK FAUCET. THE WATER COMPRESSOR C/B WAS PULLED FROM THE AFT GALLEY CEILING PANEL 2001VU. A QUICK INSP OF THE WATER COMPRESSOR WAS ALSO CARRIED OUT, AND EXTENSIVE DAMAGE WAS FOUND ON THE COMSep 30, 2010 · Airbus A320*SDR UALA2010090203222Circuit Breaker · pulledWATER QTY ISSUE, FLIGHT DIVERTED. FOUND U 28 CB POTABLE WATER WITH COLLAR ON IT. RESET, SERVICED WATER TANK TO FULL. CHECKED ALL LAVS AND GALLEY SPIGOTS. ALL FUNCTIONING NORMAL.Sep 2, 2010 · N660UA · Boeing 767322SDR R61A20100370Doubler · corrodedWHILE THE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND AT POTABLE WATER BOX DOUBLER. MAINTENANCE REMOVED & REPLACED DOUBLER IAW EMB 170 SRM 51-43-04. A/C STILL OUT OF SERVICE FOR HEAVY CHECK COMPLETION.Aug 5, 2010 · N821MD · Emb ERJ170100SUSDR YENA20100801107Heater · failedFLT 198 LAS-JFK, ELECTRICAL FUMES SMELLED BRIEFLY WHEN HOT WATER SELECTED IN FWD LAV HOT WATER HEATER TURNED OFF SMOKE AND FUME ALARM WENT OFF FOR 2 SEC AT LEVEL OFF. REMOVED AND REPLACED FWD LAV HEATER AS PER AMM 38-12-16. OPS CHECK GOOD.Aug 1, 2010 · N595JB · Airbus A320232SDR UALA2010070602392Compressor · faultyACRID SMELL REPORTED IN AFT GALLEY. ODOR ISOLATED TO H2O COMPRESSOR IN AFT PIT RT SIDEWALL. CB PULLED AND COLLARED PER MEL 3810AT. CONNECTOR REMOVED FROM COMPRESSOR AND CB PULLED ON P320. REPLACED COMPRESSOR IAW AMM.Jul 4, 2010 · N798UA · Boeing 777222SDR UALA2010052601804Valve · bindingWHILE DUMPING WATER OUT OF GALLEY BINS AN ICE SCOOP FELL INTO TOILET OF LAV 136. WHILE ATTEMPTING TO REMOVE ICE SCOOP FOUND DUMP CABLE BROKEN OFF IN TANK. THIS IS THE AFT CABIN AFT LAV THAT IS INOP. WILL REQUIRE SHROUD TO BE REMOVED AND DUMP VALVE MANUALLY OPMay 23, 2010 · N540UA · Boeing 757222SDR ASOA201000635Water Heater · contaminatedFA REPORTS CHEMICAL ODOR/ TASTE FROM POTABLE WATER. ALSO REPORTED BY PASSENGERS. DRAINED FWD POTABLE WATER AND SERVICED IAW AMM 12-18-38. (SDR CLOSED)Apr 18, 2010 · N980EV · Cndair CL6002B19SDR UALA2010041301253Valve · openNO WATER PRESSURE ON ACFT AFTER TAKE-OFF. FOUND TANK OVERFLOW VALVE IN THE OPEN POSITION. CLOSED VALVE. OPS CKS OK. IAW LM, WATER OVERFLOW VALVE TO BE REPLACED. REPLACED WATER OVERFLOW VALVE. OPS ARE GOOD.Apr 13, 2010 · N484UA · Airbus A320232SDR UALA2010031200839Cartridge · defectiveWATER LEAK, RTFL. LEAK COMING FROM SINK FAUCET IN FLIGHT. SHUT OFF WATER TO SINK AND TURNED OFF WATER HEATER. RPLC'D FAUCET. NEED TO RDF BECAUSE COULD NOT GET WATER TO FLOW OUT OF FAUCET. REPLACED CARTRIDGE AND TURNED ON BOTH WATER VALVES, OPS CKS GOOD.Mar 11, 2010 · N807UA · Airbus A319131SDR UALA2010020100384Drain Valve · openPOTABLE WATER ISSUE, FLT DIVERTED. FOUND OVERBOARD DRAIN VALVE AT SERVICE PANEL OPEN. CLOSED VALVE, SERVICED SYS. ALL OP'S GOOD COMPRESSOR INOP PRECAUTIONARY IAW OPBLM. BECAUSE ACFT DIVERTED FOR THE COMPRESSOR VIBRATION, REPLACE COMPRESSOR PRECAUTIONARY.Jan 30, 2010 · N519UA · Boeing 757222SDR UALA2010011900241Motor · overheatedODOR OF SMOKE IN AFT GALLEY. SUSPECT FLUSH MOTOR OVERHEATED. INOPED FLUSH MOTOR PULLING CB'S 28 ON P 11-4 PANEL. LAV NOT USEABLE. RE-ACTIVATED P11 S-28 FLUSH MOTOR CB AND OPERATED LAV MOTOR NUMEROUS TIMES. NO OPERATIONAL PROBLEMS OR SMOKE DETECTED IN FWD AFT Jan 18, 2010 · N519UA · Boeing 757222SDR UALA2010011300158Valve · stuckLOSS OF POTABLE WATER PRESSURE, FLIGHT DIVERTED. FOUND PRESELECT OVERFLOW VALVE STUCK OPEN. POSITIONED VALVE IN CLOSED POSITION. WATER PRESSURE NORMAL. NEED TO MANUALLY CLOSE AT EACH DEPARTURE. OVERFLOW VALVE OPENS & CLOSES OK FROM REAR SERVICE PANEL. WHENJan 12, 2010 · N776UA · Boeing 777222
Back to JASC 3810