Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA201804304612Stop Fitting · out of positionSERVICE DOOR SURROUND, LOWER OUTER EDGE. HAS TWO GOUGES CAUSED BY SERVICE DOOR LOWER FITTINGS. REMOVED AND REPLACED THE LOWER SERVICE DOOR STOP FITTING IAW SRM.SDR GTIA2018040302557Bottle · low pressureR2 DOOR ASSIST BOTTLE LOW. SERVICED THE ASSIST BOTTLE IAW AMM 52-10-00. NO LEAKS NOTED.SDR AALA201804049010Cylinder · low pressureR2 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER INDICATING 200 PSI. SERVICED THE CYLINDER TO 1800 PSI, IAW AMM 52-10-00. NO LEAKS NOTED.SDR IPXA2018040328111Bottle · inoperativeR1 DOOR BOTTLE NOT IN GREEN RANGE. R & R DOOR RESERVOIR IAW MM 52-11-04-400-801, OPS AND LEAK CHECKED GOOD.SDR AALA201804039007Bottle · low pressureR2 DOOR ASSIST BOTTLE LOW. SERVICED THE R2 ASSIST BOTTLE IAW AMM 52-22-00.SDR AALA201804049034Pin · dislodgedAFT SERVICE DOOR HAD GUIDE PIN DISLODGED WITH SPRING MECHANISM ON DOOR CATCH FOR DOOR BAYONETTE. MAINTENANCE REPLACED UPPER AND LOWER LINKS THAT HOLD GUIDE PIN IN PLACE ON THE SPRING MECHANISM OF AFT SERVICE DOOR IAW AMM 52-40-05 AND PERFORMED SATISFACTORY OPSDR AALA201804049022Pin · dislodgedAFT SERVICE DOOR HAD A GUIDE PIN DISLODGED WITH SPRING MECHANISM ON DOOR CATCH FOR DOOR BAYONETTE. MAINTENANCE REPLACED THE UPPER AND LOWER LINKS THAT HOLD GUIDE PIN IN PLACE ON THE SPRING MECHANISM OF AFT SERVICE DOOR IAW AMM 52-40-05 AND PERFORMED SATISFACTSDR DALA2018040202185Handle · bindingRIGHT AFT DOOR EXTERIOR DOOR HANDLE JAMMED OPENED. COULD NOT CLOSE DOOR. RELEASED THE EXTERIOR DOOR HANDLE AND DOOR OPS CHECKED NORMAL IAW AMM 52-11.SDR AALA20180401003Cylinder · low pressureR3 DOOR CYLINDER PRESSURE LOW. MAINTENANCE SERVICED THE R3 DOOR TO PROPER PRESSURE IAW AMM 52-22-00 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201804039036Cylinder · low pressureR3 DOOR EMERGENCY CYLINDER FOUND BELOW LIMITS. MAINTENANCE CHARGED THE CYLINDER TO PROPER PRESSURE IAW AMM 52-10-00, AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201803289019Cylinder · low pressureR2 DOOR DAMPER AND EMERGENCY OPS CYLINDER HAD LOW PRESSURE. SERVICED THE CYLINDER IAW AMM 52-10-00.SDR AALA201803289024Bottle · low pressureR2 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-13-00.SDR KCSA201803271041Gate · crackedR5 DOOR UPPER GATE CRACKED IN 2 PLACES.SDR SWAA2018032920854Frame · crackedR1 DOOR AFT FRAME WAS FOUND CRACKED. R & R THE DOOR IAW AMM.SDR AALA201803289020Gust Lock · dirtyR1 DOOR GUST LOCK INOPERATIVE. CLEANED THE GUST LOCK CONTROL MECHANISM IAW AMM 52-10-00-100-801-A. PERFORMED AN OPS CHECK. FOUND THE R1 DOOR OK FOR SERVICE. AIRCRAFT WAS GROUNDED.SDR AALA201803289015Bottle · low pressureR1 DOOR DAMPER HAD LOW PRESSURE 1500 PSI AT 60F. SERVICED THE BOTTLE IAW AMM 52-10-00. NO LEAKS FOUND.SDR ASAA2018032624044Roller · bindingCREW REPORTED THE R2 DOOR DID NOT FULLY CLOSE. ACFT GROUNDED. FOUND THE UPPER HINGE ROLLERS JAMMED OVER DOOR CLOSED SWITCH. FREED THE DOOR. NO DEFECTS OR DAMAGE NOTED AMM 52-41-00. ACFT GOOD FOR SERVICE.SDR AALA201803279026Pawl · dirtyR2 DOOR SLIDE ARM LEVER WAS STIFF TO MOVE. MAINTENANCE INSPECTED THE DOOR AREA. FOUND DEBRIS IN AND AROUND THE PAWLS, CLEANED AND LUBRICATED AND PERFORMED A SATISFACTORY OPERATIONAL CHECK.SDR AALA201803279022Cylinder · low pressureR2 DOOR DAMPER LOW PRESSURE. PRESSURE APROXIMATELY 1200 PSI. SERVICED THE R2 DOOR CYLINDER IAW AMM 52-22-00.SDR DALA2018032701942Plate · corrodedCORROSION ON PLATES OF FWD SERVICE DOOR ENTRY. THE PLATES WERE REPLACED IAW SRM 51-40-08-0G.SDR AALA20180327001Door · low pressureR3 DOOR PRESSURE LOW. SERVICED R-3 DOOR TO PROPER PRESSURE IAW 52-20-00.SDR AALA201803279010Cylinder · low pressureFOUND THE R4 DOOR EMERGENCY CYLINDER PRESSURE BELOW LIMITS. SERVICED DOOR CYLINDER IAW AMM 52-22-00. AIRCRAFT WAS GROUNDED.SDR AALA20180325006Bottle · low pressureR3 DOOR PRESSURE LOW. SERVICED DOOR BOTTLE IAW 52-20-00.SDR AALA20180325002Bottle · low pressureR3 DOOR EPAS BOTTLE HAS LOW PRESSURE. REPLACED THE BOTTLE IAW AMM 52-11-22-401.SDR AALA20180324003Cylinder · low pressureR1 DOOR PRESSURE IN EMERGENCY CYLINDER IS LOW. SERVICED THE CYLINDER TO PROPER PRESSURE IAW AMM 52-10-00.SDR CALA2018032300989Switch · inoperativeR3 DOOR FAILED TO TEST. TROUBLESHOT THE SYSTEM, FOUND THE SWITCH S52125 HAD NO CONTINUITY. REMOVED AND REPLACED IAW AMM 52-11-28-000-802, CHECKED GOOD.SDR FDEA201803220757Hinge · damagedR1 DOOR WILL NOT FROM OPEN FROM OUTSIDE. PERFORMED A GVI OF DOOR AND HINGES. DOOR NEEDS TO BE LIFTED APPROX 1/4 INCH TO OPEN. REMOVED AND REPLACED DOOR SUSPENSION SUPPORT ARM PINS AND BUSHINGS IAW AMM 52-11-12-04, DOOR OPENS AND CLOSES WITHOUT LIFTING, DOSDR GTIA2018032202533Bottle · low pressureR4 DOOR ASSIST ACCUMULATOR HAD LOW PRESSURE. SERVICED THE DOOR ASSIST ACCUMULATOR IAW AMM 52-10-00. LEAK CHECKED GOOD.SDR AALA201803229023Cylinder · low pressureR2 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. ACCOMPLISHED TSM 52-11-00-810-828-A. REPLACED THE R2 DOOR DAMPER AND EMERGENCY OPERATION CYLINDERS IAW AMM 52-11-14.SDR DALA2018032101856Door · out of sequenceFA REPORTED, UNABLE TO ARM THE R1 DOOR. THE GIRT BAR DOES NOT APPEAR TO BE IN THE CORRECT POSITION. SYNCRONIZED THE DOOR AND ARM MECHANISM.SDR AALA201803219021Cylinder · low pressureR1 DOOR EMERGENCY OPERATING CYLINDER PRESSURE LOW. 1000 PSI AT 71 DEGREES F. SERVICED THE DOOR EMERGECNY OPERATING CYLINDER IAW AMM 52-10-00.SDR GTIA2018032002528Bottle · low pressureR4 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00 TO PROPER PRESSURE.SDR IPXA2018032027667Cylinder · low pressureR1 DOOR BOTTLE PRESSURE BELOW GREEN BAND. SERVICED THE CYLINDER IAW MM 12-25-00-001. CHECKED NORMAL.SDR GTIA2018031902526Bottle · low pressureR1 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THE R1 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR AALA201803199023Bottle · low pressureCIDS PANEL DISPLAYED A R3 DOOR PRESSURE CAUTION LOW. CHARGED THE DOOR DAMPNER BOTTLE IAW AMM 52-10-00.SDR DALA2018031901806Handle · out of sequenceR3 DOOR WAS STUCK IN THE OPEN POSITION. WOULD NOT CLOSE. SEQUENCED THE DOOR HANDLE.SDR AALA201803199008Cylinder · low pressureR4 DOOR EMERGENCY CYLINDER PRESSURE IS AT 400PSI. SERVICED THE CYLINDER IAW AMM 52-10-00-614-001A. OK FOR SERVICE.SDR AALA20180319003Cylinder · low pressureR4 DOOR DAMPER CYLINDER PRESSURE IS BELOW LIMITS. SERVICED THE DOOR CYLINDER IAW AMM 52-13-00.SDR AALA20180319002Bottle · low pressureTHE R2 DOOR DAMPER PRESSURE WAS BELOW LIMITS. SERVICED R2 DOOR DAMPER BOTTLE IAW AMM 52-12-00.SDR GTIA2018031702525Bottle · low pressureR1 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THE R1 DOOR ASSIST BOTTLE IAW AMM 52-10-00. LEAK CHECKED GOOD.SDR DALA2018032902026Relay · inoperativeAFTER PARKING AT GATE, THE R1 DOOR WOULD NOT OPEN ELECTRICALLY. OPENED MANUALLY. REMOVED AND REPLACED THE FWD ENTRY DOOR UP RELAY K380 IAW SWPM 20-81. TESTED IAW AMM 52-11. FOUND SATISFACTORY.SDR DALA2018032601938Cover · damagedR4 DOOR HANDLE TRIM COVER PLATE DAMAGED. REPLACED THE DOOR HANDLE INSERT.SDR AALA201803169016Handle · brokenR2 DOOR ARM HANDLE BROKEN. REMOVED AND REPLACED R2 DOOR ARM-DISARM HANDLE IAW AMM 52-22-00. OPS CHECKED OK.SDR DALA2018031301700Mechanism · no testR4 DOOR ASSIST BOTTLE TRIGGER MECHANISM FAILED A CLEARANCE CHECK. REPLACED THE BOTTLE IAW AMM 52-11-33.SDR AALA201803139030Bottle · low pressureR4 DOOR PRESSURE LOW. MAINTENANCE CHARGED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00, AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA20180312005Cylinder · low pressureR4 DOOR, EMERGENCY OPERATION CYLINDER PRESSURE WAS FOUND LOW. MAINTENANCE SERVICED THE CYLINDER IAW AMM 52-10-00, AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201803139024Bottle · low pressureR4 DOOR ASSIST BOTTLE HAS LOW PRESSURE. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-10-00. NO LEAKS NOTED. AIRCRAFT OK FOR SERVICE.SDR DALA2018031001564Gate · gougedR1 DOOR HAS A GOUGE AT THE LOWER AFT CORNER. REMOVED AND REPLACED THE GATE IAW AMM 52-11-38.SDR AALA20180309005Bottle · low pressureFOUND THE R2 DOOR DAMPER LOW. SERVICED THE DOOR DAMPER IAW AMM 52-22-00.SDR SWAA0121030120347Beam · crackedR1 DOOR BEAM FORWARD INBOARD FASTENER CRACKED AT THE RADIUS. R & R THE DOOR IAW AMM.
Back to JASC 5240