Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2018031220319Beam · crackedR1 DOOR CRACKED AT LOWER FORWARD INTERNAL HANDLE BOX BEAM. R & R THE DOOR IAW AMM.SDR AALA201803089014Actuator · low pressureR4 DOOR DAMPER ACTUATOR PRESSURE IS LOW. INSTALLED SERVICEABLE ACTUATOR IAW AMM 52-13-14-400.SDR AALA20180308002Battery Pack · no testR2 DOOR EMERGENCY POWER ASSIST SYSTEM BATTERY PACK, NO GREEN LIGHT BLINKING. MAINTENANCE REPLACED R2 DOOR EMERGENCY POWER ASSIST SYSTEM BATTERY PACK PER AMM 52-11-20-000-805, 52-11-20-400-805, AND PERFORMED A SATISFACTORY OPERATIONAL CHECK IAW AMM 52-11-20-700SDR AALA20180308001Battery Pack · no testR3 DOOR EMERGENCY POWER ASSIST SYSTEM BATTERY PACK, NO GREEN LIGHT BLINKING. MAINTENANCE REPLACED BATTERY PACK IAW AMM 52-11-20-000-805, 52-11-400-805-002, AND PERFORMED A SATISFACTORY OPERATIONAL CHECK IAW 52-11-20-77-803-002.SDR R61A201803170333Service Door · corrodedREMOVED AND REPLACED WASTE SERVICE DOOR REF AMM 53-03-60.SDR AALA201803079023Lens · missingR3 DOOR HAS LENS MISSING. INSTALLED A NEW LENS IAW AMM 52-11-25.SDR DALA2018030701466Door · out of sequenceRIGHT CENTER PAX DOOR EICAS AND FLASHING DOOR SLIDE LIGHT WHEN ARMED. FOUND THE DOOR OUT OF SEQUENCE; CYCLED DOOR AND OPS CHECKED OK. ACFT OK FOR SERVICE. (9858786).SDR AALA201803069020Bottle · low pressureR1 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THE R1 DOOR BOTTLE IAW AMM 52-1-00.SDR AALA201803069018Panel · brokenR1 DOOR UPPER BUSSLE GUIDE BROKEN, CANNOT OPEN DOOR. REPLACED THE R1 DOOR MOVEABLE CEILING PANEL IAW AMM 25-22-04. AIRCRAFT WAS GROUNDED.SDR ASOA201803025067Plate · corrodedSERVICE DOOR STEP PLATE IS CORRODED. REMOVED AND REPLACED THE SERVICE DOOR STEP PLATE IAW SRMS 51-40-11-001-001-A01, 51-42-02-001-001-A01, AND 51-42-06-001-001-A01.SDR R61A201803020276Door · lack of lubeR1 DOOR DIFFICULT TO ARM. CLEANED AND LUBRICATED THE DOOR, PERFORMED AN OPS CHECK IAW AMM 52-41-20, OPS CHECKED GOOD.SDR AALA201803029032Bottle · low pressureCIDS WARNING R4 DOOR PRESSURE LOW. SERVICED THE DOOR ASSIST BOTTLE IAW AMM 52-13-14.SDR AALA201803029033Cylinder · low pressureR4 DOOR EMERGENCY OPERATION CYLINDER FOUND BELOW LIMITS. CHARGED THE R4 DOOR EMERGENCY OPERATION CYLINDER IAW AMM 52-10-00.SDR R61A201802270277Roller · dirtyR2 DOOR LEVER IS STICKING AND HARD TO OPEN. CLEANED DEBRIS FROM THE R2 DOOR ROLLER FITTINGS IAW AMM 52-42-00.SDR AALA201802289037Snubber · leakingBROWN OILY SUBSTANCE LEAKING FROM INTERIOR HANDLE OF THE R2 DOOR. MAINTENANCE REPLACED THE R2 DOOR SNUBBER IAW MM 52-11-08, AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201802279022Handle · brokenAIRCRAFT WAS NOT GROUNDED. RIGHT HAND FORWARD SERVICE DOOR ASSIST HANDLE BROKEN. INSTALLED HANDLE PER AMM 25-20-00.SDR SWAA2018022820153Fitting · out of positionR1 DOOR GIRT BAR FITTINGS OUT OF POSITION. REPOSITIONED FITTING IAW AMM.SDR AALA201802269076Decoder · faultyR3 DOOR PRESSURE, SLIDE LIGHT CHECK. REPLACED DECODER/ENCODER UNIT B (300RH6) SYSTEM CHECKS OK IAW AMM 23-73-42-400-001-A.SDR AALA201802269035Cylinder · low pressureR1 DOOR SHOWING LOW PSI ON CIDS PANEL. ACCOMPLISHED CHARGING OF R1 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER IAW AMM 52-10-00-614-001-A.SDR AALA201802279033Cylinder · low pressureR2 DOOR ASSIST BOTTLE LOW. MAINTENANCE CHARGED THE R2 DOOR CYLINDER TO PROPER PRESSURE IAW AMM 52-10-00-614-001-A AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR DALA2018022601185Not Reported · dirtyR1 DOOR WOULD NOT ARM. REMOVED DEBRIS.SDR R61A201802230237Rod · out of adjustR2 DOOR VENT FLAP ARMING LEVER HARD TO MOVE. PERFORMED ADJUSTMENT OF R2 DOOR VENT FLAP ROD IAW AMM 52-42-25.SDR R61A201802230236Handle · out of adjustR1 DOOR DIFFICULT TO ARM. ADJUSTED VENT FLAP AND ARMING HANDLE. OPS CHECKED GOOD IAW AMM 52-41-25.SDR DALA2018022301180Not Reported · dirtyR4 DOOR WILL NOT ARM. REMOVED DEBRIS. DOOR ARMED. OK FOR SERVICE. AMM 52-11.SDR DALA2018022301179Not Reported · dirtyR1 DOOR WILL NOT ARM. REMOVED DEBRIS. DOOR ARMED. OK FOR SERVICE. AMM 52-11.SDR DALA2018022401123Skin · crackedAFT LAV SERVICE PANEL HAS CRACK SKIN AND CORROSION ON AFT LOWER CORNER. REPAIRED PER PRI 565769-14 REV 0 THRU REV 8. RECEIVED FINAL ERA 565769-14 REV ORIG. FINAL ERA 565769-14 AND PRI 565769-14 REV 0 THRU REV 8 MATCH. REF LOG 0431540 FOR TRACKING.SDR CA180223003Seal · damaged(CAN) SER WHISTLING NOISE DOOR IN FLIGHT CABIN CREW REPORTED THAT THEY HAD A WHISTLING NOISE INTERMITTENTLY FROM DOOR 2R. IT WOULD COME AND GO. AFT SERVICE DOOR SEAL INSPECTED, FOUND DOOR SEAL WORN AND TWO CRACKS LOCATED ON UPPER RT SIDE OF THE DOOR PRESSURESDR DALA2018022201830Skin · crackedCRACK WAS FOUND OF 0.250" ON R1 FWD SERVICE DOOR, BOTTOM AREA, OUTER SKIN. PERMANENT REPAIR. CRACK ON R1 FWD SERVICE DOOR BOTTOM AREA WAS REPAIRED PER SRM 51-70-01-2R. HFEC INSPECTION WAS ACCOMPLISHED ON R1 FWD SERVICE DOOR BOTTOM AREA, OUTER SKIN AFTER TRIM OSDR FDEA201802220478Cable · deformedR1 DOOR CLUTCH RELEASE CABLE HAS DEFORMATION AND KINKING AT FWD CABLE END. REMOVED AND REPLACED THE R1 DOOR CLUTCH RELEASE CABLE IAW AMM 52-11-12.SDR DALA2018022301176Frame · crackedR2 DOOR FORWARD FRAME CRACKED AT UPPER HINGE CUT OUT IN LOWER RADIUS. REPAIRED THE R2 DOOR FORWARD FRAME IAW SRM 52-10-02, REPAIR 1, FIG 201, PRI 564964-14 REV 0, AND ER/A 564964-14 REV. ORIGINAL.SDR AALA20180224002Accumulator · low pressureR4 DOOR ACCUMULATOR LOW. MAINTENANCE SERVICED THE R4 DOOR ACCUMULATOR TO PROPER PRESSURE IAW AMM 52-10-00, AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201802269007Cylinder · low pressureR4 DOOR EMERGENCY OPERATIONS CYLINDER PRESSURE LOW, 500 PSI AT 75 DEGREES FARENHEIT. SERVICED THE CYLINDER IAW AMM 52-10-00.SDR C77A20180223001Schrader Valve · failedR2 DOOR ASSIST BOTTLE HAD LOW PRESSURE 1650 PSI. FOUND SCHRADER VALVE TO THE PNEMATIC ASSY WITH A BROKEN O-RING. R & R THE SHRADER VALVE IAW AMM 52-42-51, AND AMM 20-10-01.OK FOR SERVICE.SDR R61A201803030278Door · corrodedWASTE SERVICING DOOR HAS SEVERAL AREAS OF CORROSION ON INTERNAL SURFACE. REMOVED AND REPLACED THE WASTE SERVICE DOOR IAW AMM 53-03-60, SRM 51-23-04, 51-23-05, AND 51-23-06.SDR R61A201802210215Handle · bindingFA ADVISED THAT THE R2 DOOR IS HARD TO ARM AND DISARM. CLEANED AND PERFORMED AN OPS CHECK OF THE AFT SERVICE DOOR LOCKING MECHANISM IAW AMM 52-42-20. NO FAULTS NOTED.SDR AALA201802229033Cylinder · low pressureR1 EMERGENCY OPERATIONS CYLINDER HAD LOW PRESSURE. SERVICED THE CYLINDER IAW AMM 52-10-00.SDR CALA2018022100745Pan · gougedR1 DOOR, EXTERNAL HANDLE PAN HAS AN APPROX 1.4" LONG GOUGE. (JD116-945) BLENDED OUT GOUGE AREA ON R-1 DOOR EXTERNAL HANDLE PAN (L=2.0", W=0.4", D=.018"). AREA FOUND TO BE OUT OF LIMITS IAW B757-200 SR M 52-10-01 ALLOWABLE DAMAGE 1 FIG 101 DETAIL VI. REMOVED ANSDR AALA201802239010Bottle · low pressureR4 DOOR ASSIST BOTTLE LOW. MAINTENANCE SERVICED THE DOOR ASSIST BOTTLE TO PROPER PRESSURES AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201802199066Cylinder · low pressureAFT R4 DOOR ACCUMULATOR LOW SERVICE PRESSURE. SERVICED R/4 DOOR EMERGENCY ASSIST ACCUMULATOR PER AMM 52-10-00.SDR AALA201802199063Diaphragm · leakingR-1 DOOR PERCUSSION MECHANISM DIAPHRAM LEAKING. REPLACED R1 DOOR PERCUSSION MECHANISM DISPHRAM PER AMM 52-10-610 OPERATIONS AND LEAK CHECK GOOD.SDR AALA201802199076Bottle · low pressureCIDS PANEL DISPLAYED THE R4 DOOR PRESSURE LOW. MAINTENANCE SERVICED THE DOOR ASSIST BOTTLE IAW AMM 25-61-00. PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR DALA2018021400895Lever · detached(AIRCRAFT 6821, L/P 9973752) 1R DOOR ARMING LEVER DETACHED. RMVD R1 DOOR BUSSLE, FOUND FOD IMPEDING GIRT BAR OPERATION, RMVD FOD OPS CHK OK. OK FOR SVC. REF B757 AMM 52-11, ARM AND DISARM OK.SDR FDEA201802140400Bushing · wornR1 DOOR HARD TO OPEN FROM THE INSIDE AND OUTSIDE. INSPECTED THE R1 DOOR, AND FOUND UPPER AND LOWER HINGE SUPPORT ARM HAT BUSHINGS MIGRATED. NO DAMAGE FOUND ON R1 DOOR IAW MM 52-10-11-06. COMPLETED VISUAL INSPECTION OF R1 DOOR LOCKING & LATCHING COMPONESDR N6WA2018021401Warning Message · activatedSERVICE DOOR OUTER HANDLE CAUTION.SDR AALA201802139022Bottle · low pressureR3 DOOR EMERGENCY DAMPER PRESSURE LOW. MAINTENANCE CHARGED THE BOTTLE IAW AMM 52-22-00 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201802129075Cylinder · low pressureR2 DOOR DAMPER ACCUMULATOR PRESSURE LOW. 1500 PSI AT 50F. SERVICED THE R2 DOOR DAMPER ACCUMULATOR IAW AMM 52-10-00.SDR AALA20180211002Damper · low pressureR2 DOOR DAMPER ACCUMUILATOR HAD LOW PRESSURE. SERVICED THE DOOR DAMPER IAW AMM 52-10-00.SDR AALA201802159015Lever · out of adjustR4 DOOR DIFFICULT TO DISARM. ADJUSTED THE LEVER. OPS CHECKED OK IAW AMM DMC-B787-A-52-11-00.SDR CALA2018020900565Guide Arm · out of adjustFWD GALLEY SERVICE DOOR DIFFICULT TO CLOSE AND SEAL. THE R1 SLIDE, ARMING, DISARMING, STOWING ALL NORMAL. OPS CHECKED GOOD. FOUND THE R1 DOOR CLOSING WAS IMPEDED BY A OUT OF ADJUSTED GUIDE ARM. ADJUSTED UPPER GUIDE ARM ONLY IAW 52-41-00. DOOR OPS CHECKED GOOSDR AALA201802129040Decoder · faultyFLIGHT ATTENDANT REPORTED THE R3 SLIDE PRESSURE LOW. MAINTENANCE REPLACED THE DECODER - ENCODER UNIT 300RH6 IAW AMM 23-73-47 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.
Back to JASC 5240