Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5240' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA141030002Drain Valve · not seated(CAN) L1 DOOR DID NOT SEAL AND PREVENTED PRESSURIZATION. AFTER INVESTIGATION, WATER DRAIN VALVE FOR THE SEAL PRESSURIZATION RESERVOIR FOUND IMPROPERLY SEATED. VALVE SEATED AIRCRAFT RETURNED TO SERVICE. (SDR R61A201410231135Stop Fitting · corrodedDURING HEAVY CHECK, THE AFT SERVICE DOOR FWD THREE DOOR STOPS ARE CORRODED. MAINTENANCE R & R AFT SERVICE DOOR FWD 3 DOOR STOPS IAW AMM 52-42-23.SDR AALA20141023001Switch · defectiveRIGHT NR 1 DOOR EPAS OPERATIONAL TEST FAILED DUE TO AMBER TEST LIGHT DID NOT COME ON. SWITCH REPLACED. OPERATIONS CHECKED NORMAL.SDR SWIA201439766Tube · damagedSERVICE DOOR HARNESS CONVOLEX TUBING DAMAGED. C-CHECK, REPLACED THE SERVICE DOOR HARNESS CONVOLEX TUBING IAW REO.SDR UHLA2014102100730Indicator · out of adjustR1 DOOR LATCH INDICATOR NOT SHOWING "GREEN" WHEN DOOR IS ARMED. CLEANED AND ADJUSTED DOOR LATCH INDICATOR REF AMM 52-41-00. OPS CHECK GOOD.SDR USAA2014102100002Bottle · low pressureDOOR ASSIST BOTTLE AT 2R DOOR LOW, NEEDS SERVICE. SERVICED DOOR ASSIST BOTTLE AT 2R DOOR.SDR V0XD201410200206Tube · damagedSERVICE DOOR WIRING HARNESS CONVOLEX TUBING IS DAMAGED. REPAIRED SVC DOOR HARNESS IAW REO 670-20-12-045 DATED 2008-04-17 REV. SEE WORK ORDER 80250 & WORK CARD 8053.SDR ASOA2014111411646Angle · corrodedALL 4 ANGLE CLIPS ON THE PROTECTOR CORRODED AT SERVICE DOOR. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR IAW SOP 5702. REMOVED 4 WEB FLOOR PROTECTORS IAW SRM 51-42-06-001-001-A01 UPON REMOVAL, FOUND CORRODED AND DETERMINED OUT OF LIMIT IAW SRM 53-21-23-101-0SDR ASOA2014111311644Striker · corrodedSERVICE DOOR LOWER SEAL STRIKER CORRODED AT FWD AND AFT SCREW HOLES. BLENDED DAMAGE IAW SRM 51-12-00-001-001-A01, SP 162207. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-00-101-001-A01. REMOVED STRIKER FROM LOWER SERVICE DOOR IAW SRM 51-42-06-001-001-A01. THIS SDR ASOA2014111311643Angle · corrodedSERVICE DOOR ANGLE MOUNT CORRODED. REMOVED MOUNTING ANGLE AND LOWER SILL ANGLE IAW SRM 51-42-06-001-001-A01. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR IAW SOP 5702. ASSEMBLED NEW MOUNTING ANGLE AND EXISTING LOWER SILL ANGLE IAW SRM 51-42-06-001-001-A01 ANSDR UHLA2014101800692Actuator · out of adjustR2 DOOR WILL NOT CLOSE. FOUND HANDLE ACTUATOR SLIGHTLY OVER CENTER AND RELEASED REF AMM 52-41-00.SDR MASA2014101802679Door · bindingSERVICE DOOR WILL NOT OPEN. OPENSDR A6WA201442069Door Seal · damagedNOTED LOUD NOISE FROM SERVICE DOOR. ACFT DEPRESSURIZED AT FL210. CREW DONNED OXYGEN MASK & DECLARED AN EMER. CREW DESCENDED TO 11000 INITIALLY & DIVERTED. INSPECTED SERVICE DOOR & SEAL, FOUND HOLE IN SEAL ON UPPER AFT CORNER. R & R SERVICE DOOR SEAL IAW ASDR C77A20141021001Cable · brokenR2 DOOR SHOWING ARMED AFTER DISARMING. R & R R2 DOOR FLEXBALL CABLE IAW AMM. COMPLETED CLOSE UP OF R2 DOOR IAW AMM & REINSTALLATION OF EMER SLIDE & DOOR LININGS IAW AMM.SDR SWAA2014101733101Fitting · looseR1 DOOR LOOSE AT UPPER RT CORNER. R & R LATCH FITTING IAW MM.SDR SWAA2014120134536Doubler · crackedFORWARD LAVATORY SERVICE DOOR LOWER LOBE FUSELAGE CRACKED. REPAIRED DOUBLER IAW EA & EO.SDR N6WA2014101002Trim Panel · brokenSERVICE DOOR HANDLE TRIM BROKEN, HARD TO CLOSE. DEFERRED SERVICE DOOR PULL HANDLE IAW NEF 25-999-1 CAT 1.SDR USAA2014101300014Actuator · lowFORWARD FLIGHT ATTENDANT PANEL MESSAGE, CHECK SLIDE PRESS R2 DOOR. REPLACED THE ACTUATOR & OPS CHECKED GOOD IAW AMM 52-22-14.SDR SIMA20141007007Door Seal · defectiveSERVICE DOOR SQUEAL IN FLIGHT WITH VISIBLE GAP. TRANSFERRED TO NRWC 854-DFW-01564. REF ITEM NR 1, NR 2 & NR 3 NRWC 854-DFW-01564. R & R FRAME SEAL IAW 52-43-04. LEAK CHECKED GOOD.SDR SWAA2014110633847Hinge · looseR2 DOOR UPPER HINGE LOOSE. REPAIRED HINGE IAW MM.SDR ASOA2014102911570Skin · corrodedSERVICE DOOR LOWER INNER SKIN HAS CORROSION SEVERAL PLACES. BLENDED CORROSION IAW SRM 51-12-00-00.SDR FDEA201410042964Gate · corrodedNUMBER 2R DOOR LOWER GATE EDGE IS CORRODED. NR 2R DOOR LOWER GATE REPLACED IAW AMM 52-11-38-4SDR FDEA201410042963Gate · chafedNUMBER 4R DOOR LOWER GATE AFT EDGE HAS CHAFING DAMAGE. NR 4R DOOR LOWER GATE ASSEMBLY REPLACED IAW AMM 52-11-38-4.SDR AALA20141001007Angle · corrodedRIGHT NR 1 DOOR HAS CORROSION ON CREASE ANGLE. R & R ANGLE IAW AARD 51-00-05-1.SDR SWAA2014102233277Mount Bracket · looseR1 DOOR EMER EVAC SLIDE COVER LOWER MOUNTING BRACKET LOOSE AT DOOR LOWER FRAME. R & R BRACKET IAW SRM.SDR AALA20141007002Skin · dentedRIGHT NR 1 DOOR EXTERNAL FACE LOWER AFTER AREA FOUND DENTED. REPAIRED IAW SRM 52-10-01-2R 8 FIGURE 202.SDR SWAA2014100232548Door Frame · crackedR1 DOOR CRACKED LOWER EDGE FRAME CRACKED AT AFT LOWER CORNER STOP FITTING. R & R DOOR IAW AMM.SDR A6WA201442027Housing · gougedSERVICE DOOR OUTER HANDLE HOUSING INNER BORE GOUGED & WORN.SDR DALA2014100105354Structure · corrodedON REMOVAL OF R4 DOOR HANDLE MECHANISM FOUND CORROSION AND PITTING ON HANDLE BOX INNED DIAMETER. R & R R-4 DOOR HANDLE BOX IAW AMM 52-11.SDR USAA2014092900020Bottle · low pressureCHECK DOOR PRESS AT DOOR R2 ON CIDS PANEL. SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-40-00.SDR SWAA2014102933465Cover Plate · corrodedR1 DOOR ENTRY COVER PLATE CORRODED BETWEEN BS 160 TO 200, RBL 54. R & R PLATE IAW SRM & DWG.SDR DALA2014100105353Structure · corrodedON REMOVAL OF L4 DOOR HANDLE MECHANISM FOUND CORROSION ON HANDLE BOX INNER DIAMETER. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. R & R L-4 DOOR HANDLE BOX IAW AMM 52-11-13-902-015.SDR MASA2014092202611Door · bindingSERVICE DOOR HARD TO OPEN, TROUBLESHOOTING.SDR SWIA201439516Tube · brokenSERVICE DOOR CONVOLEX TUBE BROKEN. C-CHECK, REPAIRED THE SERVICE DOOR CONVOLEX TUBING IAW REO.SDR SWIA201439482Housing · chafedSERVICE DOOR OUTER HANDLE HOUSING CHAFED FROM HANDLE BUMP PAD WORN THROUGH. REPAIRED GALLEY SERVICE DOOR OUTER HANDLE HOUSING IAW AMM AND EA.SDR USAA2014092200010Cover · missingDOOR 4R COVER FOR DOOR HANDLE IS MISSING. INSTALLED DOOR 4R ASSIST HANDLE COVER.SDR SWAA2014112034336Hinge · brokenEXTERNAL POWER SERVICE DOOR UPPER HINGE BROKEN. R & R HINGE IAW AMM.SDR AALA20140920004Switch · failedRIGHT NR 3 DOOR EPAS BATTERY FAILED TEST. REPLACED RT NR 3 DOOR EPAS SWITCH. OPERATIONS CHECKED NORMAL.SDR DALA2014092005167Hinge Fitting · corrodedCORROSION ON HINGE FITTING OF R1 SLIDE DOOR. FITTINGS WERE REPLACED IAW SRM 51-10-3 AND 51-10-4, DWG 3936190.SDR FDEA201409172639Skin · crackedR4 DOOR INNER SKIN LIGHTNING HOLE FOUND CRACK & CHAFED AT EDGE. REPAIRED.SDR AALA20140920002Switch · failedLEFT NR 4 DOOR EPAS BATTERY PACK FAILED TEST. REPLACED LT NR 4 DOOR EPAS MODE SELECT SWITCH. OPERATIONS CHECKED NORMAL.SDR 4AER20140917001Gate · corrodedR1 DOOR LOWER GATE CASTING CORRODED.SDR GTIA2014091201417Bottle · low pressureDOOR ASSIST BOTTLE PRESSURE LOW ON R2 DOOR. SERVICED DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR FDEA201409112579Handle · damagedR1 DOOR VERY DIFFICULT TO OPEN FROM THE OUTSIDE. THE UPPER BUTTERFLY HANDLE IS NOT COMING OUT. IT WORKS ONLY WHEN PLAYING WITH THE LOWER HANDLE & ONLY WHEN PULLING VERY HARD ON THE UPPER BUTTERFLY HANDLE. REMOVED AND INSTALLED R1 EXTERIOR HANDLE MECHAMISMSDR REXA2014091100948Door Seal · defectiveSERVICE DOOR SEAL LEAKING AIR, CLIMBING THROUGH 18000 FEET LOUDER POP THAN PRIOR FLIGHT. HISS & BALLOON NOISE WAS LOUD & INCREASING. STOPPED CLIMB & DESCENDED BACK TO 16000 TO HAVE THE LOUD FLAPPING NOISE QUIT, HISS WAS STILL PRESENT. 6.7DELTA P WAS START. SDR ASOA2014091211216Door · lack of lubeSERVICE DOOR IS EXTREMELY DIFFICULT TO OPEN. LUBRICATED SERVICE DOOR IAW AMM 12-20-52, OPS CHECK GOOD, ACFT RETURN TO SERVICE.SDR SWIA201439356Handle · chafedSERVICE DOOR INNER HANDLE CHAFED ON BOTTOM SIDE FROM SERVICE DOOR HINGE ARM, C-CHECK RO 9/21/14, ORIGINAL MATERIAL THICKNESS WAS 1.700", MEASURED WITH TOOL TUC4232, DUE 28FEB2015, REMOVED 0.115" AND 0.090" NOT EXEEDING REPORTED DAMAGE DEPTH IAW STS EA. REMAISDR CA141001004Handle · lack of lube(CAN) FUSELAGE DOOR WARNING ILLUMINATED IN FLIGHT DUE TO AFT SERVICE DOOR. DURING TROUBLESHOOTING OBSERVED HANDLE WAS HARD TO OPERATE. MAINTENANCE CLEANED AND LUBRICATED THE DOOR AND HANDLE.SDR USAA2014090800005Plate · brokenPLATE REINFORCEMENT BROKEN & PLATE IS BULGING ON R2 DOOR. REPLACED BROKEN PLATE AT R2 DOOR.SDR IPXA2014091584295Mount · gougedINSPECTION 3C, R1 DOOR FWD AND AFT ESCAPE SLIDE MOUNT BRACKETS GOUGED. ACCOMPLISHED PERMANENT REPAIR TO FWD AND AFT R1 DOOR ESCAPE SLIDE MOUNTS IAW EA 011-5200-01-A5528, REV I/R AND EO 5320-55517-A.
Back to JASC 5240