SDR R61A202204190077Seat Track · corrodedCORROSION FOUND AT UPPER FLANGE BTW FR 13 AND FR 14 RH I/B SEAT TRACK. R&R IAW EMB 170/175 SRM 53-10-10.SDR SWAA2022050290217Web · corrodedCORROSION ON AFT CARGO BAY THRESHOLD AT RBL 25 BS 787+11; BS 787+13; BS 807+2; BS 827+2; BS 827+8. / [01] ENTERED MEASUREMENTS;[02] SRM 53-60-15-1A-1 ALLOWABLE DAMAGE 1 IS APPLICABLE FOR THIS AIRCRAFT.<BR><BR>REMOVED CORROSION DAMAGE IAW SRM 51-10-02-0G-0.;[03SDR SWAA2022050290344Web · corrodedCORROSION ON WEB AT AFT WET AREA BS986+8 RBL39 WL208. / [01] REMOVED CORROSION ON WEB AT BS986+8 RBL39 WL 208 IN A 1.5'X1.5'X.005 ORIGINAL THICKNESS .020 OUT OF LIMITS PER SRM 53-70-51-1A-1STEP 4-C 2 FIG 103;[02] REMOVED WEB AT BS 986 TO 1016; RBL 37 TO RBL 47SDR SWAA2022042790196Intercostal · crackedCRACKED INTERCOSTAL AT BS 294.5-312; RBL 15; WL 208.1. INSTALLED FOD PROTECTION FROM BS277 - BS328, BL 0 - RBL 30, WL 198 IAW AMM 20-60-07-913-801. REMOVED ALL FASTENERS FROM INTERCOSTAL IAW SRM 51-40-02-0G-0. REMOVED STIFFENER AT BS 312 RBL 24 AND INTERCOSSDR FDEA202203310795Door Frame · corrodedFUSELAGE CUT-OUT FOR ACCESS DOOR 313AL AFT FRAME CORRODED. EVALUATED CORROSION AT FUSELAGE CUT-OUT FOR ACCESS DOOR 313AL AFT FRAME AND FOUND TO BE CORRODED 100% OUT OF LIMITS IAW SRM 53-00-02-1A FIG. 101 DET.II, REMOVED AND REPLACED OUTER CHORD FX148N1601-SDR SWAA2022050489881Stringer · crackedCRACK STRINGER 15L LOCATED BETWEEN BS294.5 TO BS303.9 AT PASSENGER CABIN 2022-165275 / [01] TOOL USED: ULTRASONIC EQUIPMENT P/N: 45MG; S/N: 130060401; DUE DATE: 22-APR-22.;[02] TOOL USED: EDDY CURRENT EQUIPMENT; P/N: NORTEC500D; S/N: N500X12101V022240; CAL DUESDR AALA202204129245None · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT LEFT PASSENGER / CREW DOOR CUT OUT LOWER SILL AT FR 68 AND S23L. REPAIRED LOWER SILL PER SRM 53-41-14-300-001 PRINCIPLE #7.SDR CALA2022033100848None · none(A3NB-53-3-6299) FRAME 68 INBD FLANGE HAS CORROSION JUST ABOVE F LOOR LEVEL. (DOT 74-26 MARKED) () OF THE LATEST REV OF ECRA 5341-01305 ON OR BEFORE ACFT REACHES THERAFTER 47291TFC. PERFORM REPEAT INSP AT INTERVALS NOT TO EXCEED 16400FC ACCOMPLISHED INTERIM RESDR DALA2022033002132Window Frame · crackedSHIP 3269 CRACK INDICATION ON FRAME 2 WINDSHIELD CENTER POST LOWER ATTACHMENT AREA CONTINUITY FITTING LH SIDE. CORRECTIVE ACTION: COMPLIED WITH ER/A 597259-14AD REV. ORIGINAL. (2176481)SDR FDEA202203290979Seat Track · corrodedMAIN DECK CARGO COMPARTMENT FLOOR STRUCTURE - SEAT TRACK CORRODED, BETWEEN STA1600 AND STA1620, LBL60 REPAIRED MAIN DECK CARGO COMPARTMENT FLOOR STRUCTURE - SEAT TRACK, BETWEEN STA1600 AND STA1620, LBL60 PER B757 SRM53-00-52-2R REPAIR 1. THIS IS CATEGORY ASDR SIMA20220329008Floorbeam · corrodedSSI 53-10-027 FWD GALLEY L/H FLOOR DOUBLER CORRODED AT NUT PLATE HOLE ON FR 19.(LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED FWD GALLEY LH FLOOR DOUBLER AT FR 19 IAW EMB 175 SRM 51-40-08, 51-41-02, 51-43-04, AND 51-45-00.SDR SIMA20220329006None · corrodedSSI 53-23-005 AFT LAV FLOOR STRUCTURE CENTER SHEAR PANEL IS CORRODED.(LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED AFT LAV FLOOR STRUCTURE CENTER SHEAR PANEL IAW EMB 175 SRM 51-40-08.SDR SIMA20220329007None · corrodedSSI 53-23-005 AFT LAV FLOOR STRUCTURE RIGHT SPLICE AT FR 90 IS CORRODED (MARKED) (LEVEL 2 CORROSION) -C/A-REMOVED AND REPLACED AFT LAV FLOOR STRUCTURE RIGHT SPLICE AT FR 90 IAW EMB 175 SRM 51-40-08.SDR SIMA20220329005None · corrodedSSI 53-10-027 FWD GALLEY R/H FLOOR SILL CORRODED.(LEVEL 2 CORROSION) -C/A-REMOVED AND REPLACED FWD GALLEY R/H FLOOR SILL IAW EMB 175 SRM 51-40-08.SDR SIMA20220329004Floor Splice · corrodedSSI 53-10-027 FWD GALLEY L/H SHEER PLATE CORRODED AT NUT PLATE HOLE AT FRAME 16.(LEVEL 2 CORROSION) -C/A-REMOVED AND REPLACED FWD GALLEY L/H SHEER PLATE IAW EMB 175 SRM 51-40-08.SDR SIMA20220329003None · noneSSI 53-23-005 AFT GALLEY FLOOR STRUCTURE RIGHT SHEAR PANEL IS CORRODED.(LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED AFT GALLEY RIGHT SHEAR PANEL IAW EMB 175 SRM 51-40-08.SDR SIMA20220329002None · noneAFT LAV FLOOR STRUCTURE RIGHT PANEL SUPPORT IS CORRODED AT FR 89 AND 90.(LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED AFT LAV FLOOR STRUCTURE RIGHT PANEL SUPPORT IAW EMB 175 SRM 51-40-08.SDR SWAA2022040690269Dump Valve · corrodedCORROSION ON AFT LAV DUMP VALVE PAN ASSY / [01] REMOVED & REPLACED AFT LAV DUMP VALVE PAN ASSY REF SRM 51-40-02;[02] CORRECTED POTENTIAL CORROSION LEVEL ();[03] REPAIR ACCOMPLISHED ON EA-153-00959-W1P1.;[04] COMPLIED WITH;[05] REPAIR WAS COMPLETED IAW EA 22-15SDR CALA2022033100828None · noneRH PRESSURE PANEL FR 35/36 HOLES 3,4,13,14,15,20,22,23,27,28 HAV E CRACK INDICATION. GENERATED BY V061682 ON HAECO LCQ NR 9298423 /30423 AIRS ARE CAT -B- MAJOR REPAIR. START/FINISH DIMENSIONS ARE LISTE NSPECTION PER PART 2 OF THE LATEST ECRA 5331-02868 ON OR BSDR DALA2022033002120Door Frame · crackedSHIP 3259 CRACK INTERNAL STRUCTURE AFT FRAME SEGMENT LOCATED ON EMERGENCY EXIT DOOR 843 IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED FWD FRAME SEGMENT OF EMERGENCY EXIT DOOR PER A320 SRM 51-42-11 AND 51-72-11. (2175740)SDR IXXA2022032900002Support · corrodedCORROSION ON SUPPORT STATION 1417 BL0SDR SWAA2022042088616Angle · crackedFWD SERVICE DOOR FWD LOWER STUB BEAM O/B ANGLE CRACKED BS294.5 RBL 58 WL 210 FWD SERVICE DOOR FWD LOWER STUB BEAM CRACKED BS294.5 RBL 58 WL 210 / [01] REMOVED FWD SERVICE DOOR FWD LOWER STUB BEAM O/B ANGLE FROM BS 294.5; RBL-58; WL- 210 IAW SRM 51-40-02-0G-0;[SDR SIMA20220328001Seat Track · corrodedSSI 53-22-012 - RH CENTER SEAT TRACK IS CORRODED BTW FR 83-85. (MAJOR REPAIR) (LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED RH CENTER SEAT TRACK IAW EMB-175 SRM 51-40-08, EMB-175 SRM 51-41-01 EMB-175 SRM 51-43-03, EMB-175 SRM 51-43-04 EMB-175 SRM 51-21-01, EMB-SDR CALA2022033100821None · noneAFT WET AREA AT R2 DOOR STRINGER 23RT HAS FOUR EACH HOLES OVER S IZED ON HORZ FLANGE AFT OF FR68, GENERATED AT HAECO LCQ PER NR92 98484 (30484) BY V052030. REMOVED AND REPLACED AFT CABIN STRINGER 23 RT AFT OF FRAME 68 IA W A320 SRM 51-72-11. PERFORMED BY V9252SDR FDEA202203280720None · noneMAIN CABIN SEAT TRACK SCALLOP IS GOUGED LBL0 AT APPROX STA 1013 ACCOMPLISHED FEDEX EA# F-5310-T0367542 : FUSELAGE - MAINFRAME - SEAT TRACK STA 1013, BL 0, SPLICE REPAIRSDR SIMA20220327006Seat Track · gougedL/H CENTER SEAT TRACK GOUGED BETWEEN FRAMES 78-79 (MAJOR REPIAR) -C/A-RAR LH CENTER SEAT TRACK AT FRAMES 78-79 IAW EMB 175 SRM 51-40-08, 51-41-01, 51-43-03, AND 51-43-04SDR SIMA20220327005Track · gougedLH FLOOR SEAT TRACK GOUGED AT FR 23-24 (MARKED).(MAJOR REPAIR)-C/A-RAR LH FIRST CLASS SEAT TRACK BEAM BETWEEN FR 23-34 IAW EMB-175 SRM 51-40-08.SDR SIMA20220327004Track · gougedRH FLOOR SEAT TRACK GOUGED AT FR 25-26 (MARKED) (MAJOR REPAIR)-C/A-RAR RH FLOOR SEAT TRACK BEAM BETWEEN FR 23-34 IAW EMB-175 SRM 51-40-08. REFER TO NRTC E910856 FOR REINSTALLATION OF BEAM SPLICE BETWEEN FR 22-23.SDR DALA2022032802048Crossbeam · bentSHIP 3270 BENT INTERNAL STRUCTURE CROSS BEAM AT LEVEL FR30 AND BTW STRG 38RH AND STRG44 IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: REPLACED CROSS BEAM PER A320 SRM 51-42-11 AND 51-72-11. (2173015)SDR DALA2022032802047Crossbeam · bentSHIP 3270 BENT INTERNAL STRUCTURE CROSS BEAM AT LEVEL FR 26 AND BTW STRG38LH AND STGR41RH IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: REPLACED CROSS BEAM PER A320 SRM 51-42-11 AND 51-72-11. (2173010)SDR SIMA20220326010Track · corrodedSSI 53-23-005; RIGHT CENTER SEAT TRACK IS CORRODED BETWEEN FRAMES 84-85 (LEVEL 2 CORROSION) (MAJOR REPAIR)-C/A-REMOVED AND INSTALLED AFT RH CENTER SEAT TRACK BEAM IAW EMB 175 SRM 51-40-08, SRM 51-43-08, SRM 51-43-04, AND SRM 51-41-01SDR SIMA20220326007Panel Support · corrodedSSI 53-23-005; RH OTBD PANEL SUPPORT IS CORRODED BETWEEN FRAMES 89-90 (LEVEL 2 CORROSION)-C/A-RAR RH OTBD PANEL SUPPORT BETWEEN FR 89-90 IAW ERJ 175 SRM 51-40-08SDR SIMA20220326006Floorbeam · corrodedSSI 53-23-005; LH CENTER BEAM UPPER SHEET IS CORRODED BETWEEN FRAMES 85-86. (LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED LH CENTER BEAM UPPER SHEET BETWEEN FRAMES 85-86 IAW EMB-175 SRM 51-40-08SDR SIMA20220326005Floor Skin · corrodedSSI 53-23-005; RH CENTER BEAM UPPER SHEET IS CORRODED BETWEEN FRAMES 85-86 (LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED RH CENTER BEAM UPPER SHEET BETWEEN FRAMES 85 AND 86 IAW EMB-175 SRM 51-40-08SDR SIMA20220326003Splice Plate · corrodedSSI 53-23-005; CENTER SPLICE IS CORRODED AT FRAME 90 (LEVEL 2 CORROSION) -C/A-RAR CENTER SPLICE AT FRAME 90 IAW EMB 175 SRM 51-40-08SDR SIMA20220326002Intercostal · corrodedSSI 53-23-005; RH INTERCOSTAL SPLICE IS CORRODED AT FRAME 90 (LEVEL 2 CORROSION) -C/A-RAR RH INTERCOSTAL SPLICE AT FRAME 90 IAW EMB 175 SRM 51-40-08SDR SIMA20220326004Gusset · corrodedSSI 53-23-005; R/H FLOOR BEAM SPLICE IS CORRODED AT FRAME 90 MAJOR REPAIR (LEVEL 2 CORROSION) -C/A-RAR R/H FLOOR BEAM SPLICE AT FRAME 90 IAW EMB 175 SRM 51-40-08SDR ANCF20220317016None · none26.MAR.2022 WO 54394182 => BIRD STRIKE
BIRD STRIKE DURING TO AT 800 FT ALL SYS OPERATION NORMAL LDG WT 65900KG NORMAL ENG PARAMETERS.
26.MAR.2022 WO 54394182 => IN ACCORDSANCE WITH AMM TASK 05-51-14-200-803 INSPECTION OF THE AIRFRAME AFTER BIRD STRIKE WASDR AALA202203285721Window Post · noneAIRCRAFT IN BASE MAINTENANCE: FLIGHT DECK FIRST OFFICERS #1 WINDOW POST REQUIRES REINFORCING MODIFICATION / REPAIR PER EO 5616J009-008. ACCOMPLISHED REINFORCING MODIFICATION / REPAIR OF THE FIRST OFFICERS #1 WINDOW POST PER EO 5616J009-008.SDR SIMA20220325009Track · gougedRH UPPER SEAT TRACK IS GOUGED AT FRAME 56 (MAJOR REPAIR)-C/A-COMPLETED SEAT TRACK SPLICE REPAIR AND INSTALLED 3 EA SPLICES ON RH UPPER SEAT TRACK AT FR 56 IAW EMB 175 SRM 53-00-10RE01SDR SWAA2022041988221Support Angle · crackedCRACKED INTERCOSTAL UPPER SUPPORT ANGLE STA 380-400; RBL 9; WL 208. / [01] REMOVED DAMAGED INTERCOSTAL UPPER SUPPORT ANGLE STA 380-400; RBL 9; WL 208 PER SRM 51-40-02-0G-0.;[02] LOCATED AND DRILLED NEW INTERCOSTAL UPPER SUPPORT ANGLE STA 380-400; RBL 9; WL 208SDR SWAA2022041988228Attach Angle · crackedCRACKED INTERCOSTAL UPPER ATTACH ANGLE STA B380-400; LBL 13; WL 208. / [01] REMOVED; LOCATED AND DRILLED NEW INTERCOSTAL UPPER ATTACH ANGLE BS380 - BS400 LBL 13 WL 208 IAW SRM 51-40-05-0G-0 AND DWG 143A5400. OK TO INSTALL;[02] VERIFIED CORRECTIVE ACTION 1.<BR>SDR SIMA20220325007Track · corrodedRH CENTER FLOOR BEAM IS CORRODED BETWEEN FRAMES 12-15 (MAJOR REPAIR) (LEVEL 2 CORROSION)-C/A-PERFORMED REPAIR DOUBLER AND FILLER ON RH CENTER FLOOR BEAM BETWEEN FRAMES 12-15 IAW EMB 175 SRM 53-10-10RE-01, FIGURE 202.SDR SIMA20220325006Doubler · corrodedSSI 53-10-027 L/H FLOOR DOUBLER IS CORRODED BETWEEN FRAMES 19 AND 20 (LEVEL 2 CORROSION)-C/A-REMOVED AND INSTALLED SERVICEABLE L/H FLOOR DOUBLER BETWEEN FRAMES 19-20 IAW EMB 175 SRM 51-40-08, 51-40-04,51-23-04,51-40-02SDR CALA2022032800796Seat Track · corrodedSUPPORT TASK, MAIN CABIN STA 730 RBL24 SEAT TRACK SUPPORT HAS CO RROSION, TRANSCRIBED FROM HAECO GSO NRC 9285765SDR CALA2022032800795Door Frame · cracked(SFR) FOUND CRACK ON RH EMERGENCY EXIT DOOR INTERIOR FRAME P/N: D5227902620200SDR KCSA202203251031Tension Tie · crackedSTA 1140 R/H HAS CRACK INDICATIONS IN UPPER AND LOWER O/B HOLES OF TENSION TIE TO FRAME CONNECTIONSDR AALA202203258112Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: FLIGHT DECK CAPTAINS #1 WINDOW FRAME CRACKED AT BS 217. REPAIRED WINDOW FRAME PER EO 5319J023-007.SDR AALA202203253551Window Frame · noneAIRCRAFT IN BASE MAINTENANCE: FLIGHT DECK FIRST OFFICERS #1 WINDOW FRAME REQUIRES REINFORCING MODIFICATION / REPAIR PER ECO 5319J023-008. ACCOMPLISHED REINFORCING MODIFICATION / REPAIR PER ECO 5319J023-008.SDR IXXA2022052406Stringer · crackedSTRINGER 24 AT STA 676 CRACKED