JASC 5311
Service difficulty reports · 61,549
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2016051651797Frame · crackedFRAME CRACKED AT BS 747, BETWEEN STRINGER 8R - 9R. REPAIRED FRAME IAW EA.SDR SWAA2016051651795Frame · crackedFRAME CRACKED AT BS 787, BETWEEN STRINGER 8L - 9L. REPAIRED FRAME IAW EA.SDR SWAA2016051651794Frame · crackedFRAME CRACKED AT BS 727D, BETWEEN STRINGER 8L - 9L. REPAIRED FRAME IAW EA.SDR ABXA20160506088Failsafe · crackedLOWER FASTENER HOLE IN RT FAILSAFE COMMON TO T FITTING IS CRACKED, VERIFIED BY HFEC HOLE SCAN. TRIMMED OUT CRACK ON FAILSAFE STRAP COMMON TO T FITTING IAW DOCUMENT 47008ORD04, THAT IS ATTACHED TO JC EA 53500014-003 FOR WORK STEPS TAKEN. CRACKED LENGTH .125",SDR REXA2016050600776Frame · corrodedLOWER MID FRAME CORRODED AT FS 319.00, STRINGER 23R. REPAIR LOWER MID FRAME IAW EA CRJ253-04290.SDR DALA2016050903792Frame · corrodedFUSELAGE, SECTION 46, FRAME AT BS 1640, S-16L TO S-17L, CORROSION. REINFORCEMENT REPAIR MONITOR INSPECTION REF ERA545011-14AD. REF ERA 545011-14AD.SDR DALA2016050703784Frame · dentedFWD CARGO RT SIDE FRAME, BS 660 HAS 3 EA DENTS STR 23R TO 25R. ACCOMPLISHED PERMANENT REPAIR ON FWD CARGO RT SIDE FRAME STA 660, STR 23R TO STR 27R REF ER/A 546341-14AD REV ORIGINAL REF THIS LOGPAGE, NRC FOR REPAIR ACCOMPLISHMENT.SDR A6WA201643855Frame · crackedFS 333.00 FRAME CRACKED INBD OF PAX DOOR UPPER SILL.SDR CALA2016050695348Frame · damagedFRAME 15, AFT SIDE WEB DAMAGED, APPROX AT STRINGER 2L. REPAIRED FRAME 15 TD-P1-52-19995-2016 & SRM 51 -42-11, 51-21-11 & 51-75-12.SDR SPUY201605060004Frame · corrodedWING CENTER FRONT SPAR LOWER CHORD, CENTER WING WITH CORROSION BS 740.00 LT LBL 20,SDR SWAA2016051651793Frame · crackedFRAME CRACKED AT BS 500A, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2016051651792Frame · crackedFRAME CRACKED AT BS 480, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2016051651791Frame · crackedFRAME CRACKED AT BS 440, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2016051651790Frame · crackedFRAME CRACKED AT BS 867, BETWEEN STRINGER 8R - 9R. REPAIRED FRAME IAW EA.SDR SWAA2016051651789Frame · crackedFRAME CRACKED AT BS 440, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2016051651788Frame · crackedFRAME CRACKED AT BS 400, STRINGER 8R. REPAIRED FRAME IAW EASDR SWAA2016051651787Frame · crackedFRAME CRACKED AT BS 360, STRINGER 8R. REPAIRED FRAME IAW EA.SDR ABXA20160505089Failsafe · crackedLEFT FAILSAFE LOWER HOLE COMMON TO T FITTING HAS CRACK INDICATION, VERIFIED BY HFEC ROTARY HOLE SCAN. TRIMMED OUT CRACK ON FAILSAFE STRAP COMMON TO T FITTING IAW DOCUMENT 47008ORD03, THAT IS ATTACHED TO JC EA 53500013-003 FOR WORK STEPS TAKEN. CRACKED LENGTHSDR FDEA201605051472Frame · corrodedAFT PIT STATION 1500, FRAME AT FLOOR STRINGER RBL 7.55, CORRODED AT FLANGE. R & R FRAME AT STATION 1500, STRINGER 25L - 25R IAW SRM-51-40-02-0G & DWG 146N1030. REPAIR CLASSIFIED AS CAT A MAJOR REPAIR. CORROSION WAS REMOVED IAW-SRM-51-10-02. AFTER REWORK, ASDR DALA2016050703785Frame · dentedTWO DENTS ON AFT CARGO LT FRAME UPPER FLANGE AT BS 1280 ABOVE STR 26L. ACCOMPLISHED PERMANENT REPAIR ON AFT CARGO LT FRAME UPPER FLANGE AT BS 1280 ABOVE STR 26L IAW ER/A 544736-14AD REV A. REFER TO THIS NRC AND THIS LOGPAGE FOR REPAIR.SDR SWAA2016050951654Frame · crackedFRAME CRACKED AT BS 400, STRINGER 8L. REPAIRED FRAME IAW SRM.SDR V0XD20160508091Frame · crackedFRAME AT FS 333.00, STRINGER 2R HAS A CRACK. R & R FRAME 333, BETWEEN STRINGER 0 - 8R IAW SRM 51-42-06, 51-42-21, 51-40-11, 51-25-06, 51-21-11, 51-25-16 & 51-32-54, AMM 51-21-01 & DWG SH 670-35625.SDR V0XD20160508090Frame · crackedFRAME AT FS 333.00, STRINGER 2R HAS A CRACK. R & R FRAME 333, BETWEEN STRINGER 0 - 8R IAW SRM 51-42-06, 51-42-21, 51-40-11, 51-25-06, 51-21-11, 51-25-16 & 51-32-54, AMM 51-21-01 & DWG SH 670-35625. WO 80391 & WC 8072.SDR DALA2016050603744Frame · corrodedCORROSION ON AFT CARGO LT FRAME UPPER FLANGE AT BS 1280 ABOVE STR 23L. ACCOMPLISHED PERMANENT REPAIR ON AFT CARGO LT FRAME UPPER FLANGE AT BS 1280 ABOVE STR 23L IAW ER/A 544736-14AD REV A, REFER TO NRC AND LOG FOR REPAIR.SDR DALA2016050603698Frame · damagedTOOL DAMAGE ON FRAME REPAIR BETWEEN LONGERON 26 LT AND 25 LT, BS 1287 AT AFT CARGO COMPARTMENT. REPAIR ANGLE WAS REPLACED, DRILLED, ADJUSTED, TRESTED AND PAINTED IAW SRM 51-10-4, 51-10-3 PAR 21 AND 14, 51-30-2, 51-30-5 AND 53-05 D, FIG 2A.SDR SWAA2016052652160Frame · crackedRIGHT BULKHEAD LOWER FRAME WEB CRACKED AT BS 727, INBD OPEN FASTENER HOLE AT WL 200. REPAIRED WEB IAW EA.SDR SWAA2016052652141Frame · crackedFRAME CRACKED AT BS 907, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2016052652140Frame · crackedFRAME CRACKED AT BS 907, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2016052552112Frame · crackedFRAME CRACKED AT BS 480, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2016052552111Frame · crackedFRAME CRACKED AT BS 500A, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2016052552082Frame · crackedFRAME CRACKED AT BS 827, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2016052552081Frame · crackedFRAME CRACKED AT BS 787, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2016052552080Frame · crackedFRAME CRACKED AT BS 747, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2016052552079Frame · crackedFRAME CRACKED AT BS 727D, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2016052552078Frame · crackedFRAME CRACKED AT BS 727B, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2016052552077Frame · crackedFRAME CRACKED AT BS 500C, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2016052552076Frame · crackedFRAME CRACKED AT BS 500A, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2016052552075Frame · crackedFRAME CRACKED AT BS 380, STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2016052552074Frame · crackedFRAME CRACKED AT BS 867, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2016052552073Frame · crackedFRAME CRACKED AT BS 827, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2016052552072Frame · crackedFRAME CRACKED AT BS 787, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2016052552071Frame · crackedFRAME CRACKED AT BS 727D, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2016052552070Frame · crackedFRAME CRACKED AT BS 500C, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2016052552069Frame · crackedFRAME CRACKED AT BS 400, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2016052552068Frame · crackedFRAME CRACKED AT BS 360, STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2016052452047Frame · crackedLEFT 727 BULKHEAD LOWER FRAME WEB CRACKED AT THE INBD OPEN FASTENER HOLE AT WL 200. REPAIRED FRAME WEB IAW EA.SDR REXA2016050400760Frame · corrodedFS 319 FRAME HAS CORROSION AT STRINGER 27 & 23R. CONTINUATION CARD 8783711 OP 318. REMOVED & INSTALLED SERVICEABLE FRAME 319 LOWER IAW SRM 51-42-06 & 51-42-21.SDR DALA2016050503639Frame · crackedCRACKED FRAME CLIPS 1437 BETWEEN LONGERON 1RT AND 3RT. FRAME CLIPS WERE REPLACED IAW DOUGLAS DWG NR 9953016, REV AT, ETI-88-16-191 REV 1 AND ER/A 545160-14, REV.SDR VNAA2016050400003Frame · corrodedFRAME IS CORRODED FS 549 BELOW WL 72.5 WHERE THE FLOORBEAM ATTACHES AT THE LT SIDE. MAINTENANCE REPARED FRAME SECTOR AT FS 549 IAW REO 670-53-31-364 REV DATED 2016-04-14.SDR VNAA2016050400002Frame · corrodedFRAME IS CORRODED AT FS 565 BELOW WL 72.5 WHERE THE FLOORBEAM ATTACHES AT THE LT SIDE. MAINTENANCE REPAIRED FRAME SECTOR AT FS 565 IAW REO 670-53-31-364, REV.
Back to JASC 5311