SDR SWAA042744Frame · crackedDURING SCHEDULED D-CHECK, FOUND 2 FRAMES AT BS 188, LBL 32 AND BS 188, RBL 32, CRACKED. REMOVED AND REPLACED FRAME SECTIONS PER SRM.SDR SWAA042737Frame · crackedDURING SCHEDULED D-CHECK, FOUND FRAME AT LT BS 188, WL 208, CRACKED. REMOVED AND REPLACED FRAME SECTION PER SRM.SDR 371PA0062Frame · crackedFRAME CRACKED AT RIVET AT BS 500 AND STR 25LT. REPAIRED IAW SRM 51-70-11.SDR 04FDEA02749Frame · corrodedFOUND CORROSION AT FUSELAGE FRAME 12A AFT FACE AT VICINITY OF STRINGER 44LH. REPAIR C/W AS PER EA 6-5310-77952. RII BY L4724.SDR 04FDEA02748Frame · corrodedFUSELAGE FRAME 14A FWD AND AFT FACE AT VICINITY OF STRINGER 44 LT FOUND CORRODED. REPAIR C/W AS PER EA 6-5310-77955. RII BY L4724.SDR 04FDEA02747Frame · corrodedFUSELAGE FRAME 13A FWD AND AFT FACE AT STRINGER 44 LT FOUND SIGNS OF CORROSION. REPAIR C/O AS PER EA 6-5310-77954. RII L4724 (SIAEC).SDR SWAA042725Beltframe · corrodedDURING SCHEDULED 1/4D CHECK, FOUND BELTFRAME AT BS 500, STRINGER 24R, CORRODED. REPAIRED BELTFRAME PER SRM.SDR 2004UALA00882Frame · dentedFWD PIT MAIN FRAME AT BS 540, BETWEEN STR 24L- STR 25L, DENTED ON IB FLANGE. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. INSTALLED A DOUBLER REPAIR ANGLE.SDR 2004UALA00881Frame · dentedAFT PIT FRAME DENTED AT BS 1460 AND STR 26L, ON IB FLANGE. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. INSTALLED FRAME DOUBLER ANGLE.SDR 2004UALA00880Frame · dentedFWD PIT FRAME AT BS 520 AND STR 24L IS DENTED ON IB FLANGE. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. INSTALLED FRAME DOUBLER ANGLE.SDR USAA040622Frame · crackedPIT - FOUND STUB FRAME CRACKED .5 INCH LONG, STATION 360, S11L. FABRICATED NEW CLIP AND INSTALLED PER SRM 51-40-02 AND BOEING DWG 60-48985. (M)SDR 2004UALA00876Frame · dentedFWD PIT FRAME DENTED AT BS 580 STR 23L. INSTALLED J-ANGLE REPAIR.SDR DLM88040895Frame · crackedCRACK ON FORMER WEB AT X=0 OF AFT P-DOME FWD FACE STRUCTURE AEROMEXICO NRC T0024606. REPLACED FORMER WEB.SDR 04FDEA02721Frame · corrodedWHILE REMOVING CORROSION ON SHEAR TIE AT BS 1148 BETWEEN STRINGERS 28L AND 28R CORROSION WAS FOUND TO BE .100 PERCENT THROUGH THE FRAME. ALL WORK DONE PER E.A. 7-5310-55378SDR 04FDEA02710Frame · dentedFUSELAGE FRAME AT STA 1601, LT L12, FOUND DENTED. DENTED AREA TRIMMED OUT AT CABIN-FUSELAGE FRAME STA 1601, LEFT HAND LONGERON 12 AND REPAIR CARRIED OUT AS PER SRM 53-30-00 VOL I AND INSTALLED AS PER SRM 51-33- 01 VOL II. REFER TO EA 1-5310-79743.SDR 371PA0065Frame · crackedFRAME CRACKED AT RIVET AB BS 460 AND STR 25 LT. REPAIRED IAW SRM 51-70-11.SDR 371PA0064Frame · crackedFRAME CRACKED IN RADIUS AT BS 480 AND STR 25 LT. REPAIRED PER SRM 51-70-11.SDR SWAA042683Frame · corrodedDURING SCHEDULED D-CHECK, FOUND FRAME AT BS 847, STRINGER 27R, CORRODED. REMOVED AND REPLACED FRAME SECTION PER ER.SDR SWAA042666Frame · crackedDURING SCHEDULED D-CHECK, FOUND FRAME AT BS 847, STRINGER 8R CRACKED. REPAIRED FRAME SECTION PER SRM.SDR 2004UALA00884Frame · dentedAFT PIT FRAME AT BS 1440 IS DENTED BETWEEN STRINGERS 25L AND 26L. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. INSTALLED REINFORCING ANGLE REPAIR.SDR P5CA0401212Frame · puncturedBULK CARGO COMPT FUSELAGE FRAME WEB BELOW THE UPPER CHORD IS PUNCTURED. CUT OUT DAMAGED AREA, FABRICATED DOUBLER & FILLER, REINSTALLED, TREATED & PRIMED.SDR P5CA0401226Frame · corrodedCTR CARGO COMPT FRAME TOP OF UPPER CHORD AT STA 1740 RBL 40 IS CORRODED. REMOVED CORROSION FOUND OUT OF LIMITS, INSTALLED NEW CHORD.SDR P5CA0401203Frame · corrodedBULK CARGO COMPT FUSELAGE FRAME, UPPER CHORD TOP & BOTTOM HAS SURFACE CORROSION. REMOVE CORROSION, ORIGINAL MATERIAL IS 0.085, AFTER REWORK 0.083 WITHIN LIMITS.SDR SWAA042667Frame · crackedDURING SCHEDULED D-CHECK, FOUND FRAME AT BS 480, STRINGER 8L, CRACKED. REPAIRED FRAME SECTION PER SRM.SDR 2004UALA00885Frame · dentedAFT PIT MAIN FRAME AT BS 1420, STR 26L IS DENTED. INSTALLED REINFORCING ANGLE REPAIR.SDR UPS04843305Frame · corrodedINSPECTION TYPE: C3, FS 1360 FRAME LWR FLANGE AT LONGERON 36 HAS EXFOLIATION CORROSION. REMOVED CORROSION & FOUND OUT OF LIMITS IAW DC-8 SRM 53-2-0 FIG 1F. FABRICATED TWO REPAIR ANGLES & INSTALLED IAW DC-8 SRM 53-2-0, 51-1-21 AND 51-1-20D.SDR 2004UALA00906Frame · dentedAFT PIT MAIN FRAME STA 1400, STR 25L TO 26L DENTED. MAJOR REPAIR ACCOMPLISHED. INSTALLED J-ANGLE REPAIR.SDR 2004UALA00905Frame · dentedAFT PIT FRAME DENTED STA 1540 AT STR 26L. MAJOR REPAIR ACCOMPLISHED. INSTALLED J-ANGLE REPAIR.SDR 2004UALA00904Frame · dentedAFT PIT FRAME STA 1480 IS DENTED BETWEEN STR 25L AND 26L. MAJOR REPAIR ACCOMPLISHED. INSTALLED J-ANGLE REPAIR.SDR CALA0400632Frame · corrodedINSPECTION FOUND FRAME CORRODED IN FORWARD CARGO COMPARTMENT AT STA 480, RBL 11. REPAIRED FRAME IAW SRM 53-00-07, FIGURE 206.SDR GAIA04138Frame · dentedDURING C-CHECK INSPECTION FOUND MAIN CABIN FRAME AT BS 660 ABOVE STR17,16 RT, DENTED. REF FASI NR 86687, CUT OUT DAMAGED AREA DIM 1.0 X 2.25 AND 1.0 X 2.25. INSTALLED ANGLE REPAIR IAW SRM 51-40-3, FIG 1.SDR GAIA04137Frame · dentedDURING C-CHECK INSPECTION FOUND MAIN CABIN FRAME BS 640 ABOVE STR 17, STR 16, RT DENTED. REF FASI NR 86686 CUT OUT DAMAGED AREA DIM 1.0 X 3.50. INSTALLED ANGLE REPAIR IAW SRM 51-40-3, FIG 1.SDR GAIA04136Frame · dentedDURING C-CHECK INSPECTION FOUND MAIN CABIN FRAME AT BS 600 ABOVE STR 17 RT, DENTED. REF FASI NR 86685, CUT OUT DAMAGED AREA DIM 1.0 X 3.50. INSTALLED ANGLE REPAIR IAW SRM 51-40-3, FIG 1.SDR GAIA04135Frame · dentedDURING C-CHECK INSPECTION, FOUND MAIN CABIN FRAME AT BS580 ABOVE STR17,STR16 RT, DENTED. REF FASI NR 86684, CUT OUT DAMAGE AREA DIM 1.0 X 6.0, INSTALLED ANGLE REPAIR IAW SRM 51-40-3, FIG 1.SDR GAIA04133Frame · dentedDURING C-CHECK INSPECTION, FOUND BS540 FRAME WITH DENTS INTO THE RADIUS. REF FASI NR 86682, ACCOMPLISHED ANGLE REPAIR IAW SRM 51-40-9, FIG 1.SDR GAIA04132Frame · dentedDURING C-CHECK INSPECTION, FOUND MAIN CABIN FRAME AT BS 520, ABOVE STR 17 RT, DENTED. REF FASI NR 86681, CUT OUT DAMAGED AREA DIM 1.0 X 2.50. INSTALLED ANGLE REPAIR IAW SRM 51-40-3, FIG 1.SDR GAIA04131Frame · dentedDURING C-CHECK INSPECTION FUND MAIN CABIN FRAME AT BS 500 ABOVE STR 17 RT DENTED. REF FASI NR 86680, CUT OUT DAMAGED AREA DIM 1.0 X 2.0. INSTALLED ANGLE REPAIR IAW SRM 51-40-3, FIG 1.SDR GAIA04130Frame · dentedDURING C-CHECK INSPECTION FOUND MAIN CABIN FRAME AT BA 400 ABOVE STR 7 AND 6 RT DENTED. REF FASI NR 86679, CUT OUT DAMAGED AREA DIM 1.0 X 2.125 AND 1.0 X 4.0. INSTALLED ANGLE REPAIR IAW SRM 53-10-4, FIG.SDR GAIA04129Frame · dentedDURING C-CHECK INSPECTION FOUND MAIN CABIN FRAME AT BS 380 DENTED ABOVE STR 7 AND 6 RT. REF FASI NR 86678 CUT OUT DAMAGED AREA DIM 1.0 X 3.50 AND 1.0 X 3.0. INSTALLED ANGLE REPAIR IAW SRM 53-10-4, FIG 1.SDR GAIA04128Frame · dentedDURING C-CHECK INSPECTION FOUND MAIN CABIN FRAME AT BS 400 DENTED ABOVE STR 8, LT. REF FASI NR 86677, CUT OUT DAMAGED AREA DIM 1.0 X 3.50, INSTALLED ANGLE REPAIR IAW SRM 53-10-4, FIG 1.SDR GAIA04127Frame · dentedDURING C-CHECK INSPECTION FOUND MAIN CABIN FRAME AT BS 380 DENTED ABOVE STR 7 LT. REF FASI NR 86676, CUT OUT DAMAGED AREA, DIM 1.0 X 3.0 INSTALLED ANGLE REPAIR IAW SRM 53-10-4, FIG 1.SDR GAIA04126Frame · dentedDURING C-CHECK INSPECTION FOUND DENT IN FUSELAGE FRAME AT STA 1090, STR 25 LT. REF FASI NR 86673, CUT OUT DAMAGED AREA DIM 1.125 X 1.0 INSTALLED SPLICE IAW SRM 51-40-3, FIG 1.SDR GAIA04108Frame · crackedDURING C-CHECK INSPECTION FOUND EE COMPARTMENT, BS 400, STR 25R FRAME ANGLE HAS CUT. REF FASI NR 86452, REPAIRED EE COMPARTMENT FRAME ANGLE IAW SRM 53-10-4, FIG 11.SDR USAA040710Frame · crackedFRAME, .5 INCH CRACK, BS907, S-8L-S-9L. CUT OUT CRACK, INSTALLED PLUG FILLER AND DOUBLER IAW SRM 53-00-07, FIG 202.SDR ASOA04756Doubler · corrodedDUIRNG A C-CHECK IN YUL, THE DOUBLER ON FRAME 40, STRINGER 17L WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE REMOVED AND REPLACED THE DOUBLER ON FS 40, STRINGER 17L IAW SRM 51-25-01. (M)SDR USAA040688Frame · crackedPIT - FOUND FRAME CRACKED .5 INCH CRACK, FRAME BS 867 S8R, S9R. CUT OUT CRACK, INSTALLED PLUG FILLER AND DOUBLER PER SRM 53-00-07. (M)SDR USAA040693Frame · crackedPIT - FOUND FRAME CRACKED .5 INCH, FRAME BS 727F, S8L, S9L. CUT OUT CRACK, INSTALLED FILLER AND DOUBLER PER SRM 53-00-07, FIG 202. (M)SDR USAA040691Frame · crackedPIT - FOUND FRAME CRACKED .5 INCH, BS 727D, S8R, S9R. CUT OUT CRACK, INSTALLED FILLER PLUG AND DOUBLER PER SRM 53-00-07 FIG 202. (M)SDR USAA040690Frame · crackedPIT - FOUND FRAME CRACKED .5 INCH, FRAME FS 747, S8R S9R. CUT OUT CRACK, INSTALLED PLUG FILLER AND DOUBLER PER SRM 53-00-07 FIG 202. (M)SDR USAA040695Frame · crackedPIT - FOUND FRAME CRACKED .5 INCH, BS 867, S8L, S9L. CUT OUT CRACK, INSTALLED PLUG FILLER AND DOUBLER PER SRM 53-00-07 FIG 202. (M)
Back to JASC 5311