JASC 5311
Service difficulty reports · 61,554
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS04441959Frame · crackedINSPECTION TYPE: C, M/D - NR 5R MED CUTOUT BS 2231 FRAME AT S25R FOUND 1 FASTENER HOLE CRACK AT STRAP. M/D R5 DOOR FWD CUTOUT FRAME STRAP REPAIRED PER SRM 53-10-04 FIG 115.SDR SWAA040449Frame · crackedDURING SCHEDULED D CHECK, FOUND FRAMES CRACKED AT BS 867, BETWEEN STRINGERS 8L AND 9L, AND BS 907, BS 887, BS 867, BETWEEN STRINGERS 8R AND 9R. REPAIRED FRAMES PER ER.SDR SWAA040448Frame · crackedDURING SCHEDULED D CHECK, FOUND FRAME CRACKED AT BS 188, STRINGER 17R. REMOVED AND REPLACED FRAME SECTION PER SRM.SDR MALA040200Frame · damagedDURING C-CHECK INSPECTION IN LCQ, LT FUSELAGE FRAME 20A STRINGER 17L HAS DENTS AND GOUGES. MAINTENANCE FABRICATED AND INSTALLED PERMANENT FUSELAGE REPAIR IAW MESABA EO A53133. A/C RELEASE DATE 2/20/04.SDR DL73S040149Frame · crackedDURING INSPECTION OF THE BS 663 FRAME CRACKS WERE NOTED IN THE FRAME AT S3L, S2L AND S1. DURING INSTALLATION OF THE SRM FRAME REPAIR IT WAS NECESSARY TO CUT THE FUSELAGE SKIN TO ACCOMMODATE FRAME REPAIR FASTENERS. FRAME WAS REPAIRED PER SRM, SKIN REPAIRED PESDR 04FDEA00397Frame · chafedAFT TAIL CONE LT FWD FRAME FOUND WITH CHAFED MARK. AFT TAIL CONE LT FWD FRAME REMOVED & REPLACED AS PER SRM 513101 V2.SDR CALA0400104Frame · dentedINSPECTION FOUND FRAME DENTED AT BS 1460, S27L. THE FRAME WAS REPAIRED IAW SRM 53-00-07, FIGURE 201.SDR COMA0460133Doubler · crackedRIGHT FS 718 BETWEEN STRINGERS 10R AND 12R P/N 600-36030-32 IS CRACKED. PERFORMED A MAJOR REPAIR TO FS 718 BETWEEN STRINGERS 10R AND 12R BY REMOVING AND REPLACING DOUBLER P/N 600-36030-32 IAW CRJ 200 SRM 51-42-00 AND 51-42-21.SDR ASAA0410064Frame · corrodedOKC - DURING SCHEDULED C-CHECK, FOUND THE FRAME AT BS 887, STRINGER 24L-25L CORRODED. REPAIRED PER SRM. (M)SDR 04FDEA00391Frame · chafedFWD TAIL CONE AFT LT FRAME FOUND CHAFED MARK. FWD TAIL CONE AFT LH FRAME REPAIR CARRIED OUT AS PER SRM 53-00-01 FIG 9 VOL1.SDR SWAA040430Frame · crackedDURING SCHEDULED 1/2D CHECK, FOUND FRAME IN E/E COMPARTMENT CRACKED AT BS 344, BETWEEN STRINGERS 23L AND 24L. REPAIRED FRAME SECTION PER SRM.SDR HALA0400211Frame · crackedHNL - DURING A 1A/1C4 CHECK, A 1.75 INCH CIRCUMFERENTIAL CRACK WAS FOUND ON THE CANTED FRAME REAR SPAR BULKHEAD STATION 1178.225 BELOW LONGERON 17L, IN THE CAP'S FORWARD FLANGE P/N 9911839-15. ACCOMPLISHED REPAIR PER HAL M105 FILE 485031. REMOVED AND INSTALLSDR 04FDEA00388Frame · dentedCABIN G-NET YOKE ASSY ATTACHMENT AT LT SIDE STA 535 DENTED AT UPPER & LOWER LOCATION. CABIN G-NET YOKE ASSY ATTACHMENT AT LT SIDE STA 535 DENTED AT BOTH UPPER & LOWER LOCATION REPAIR CARRIED OUT AS PER DWG NR SRZ-53-503 & PERFORMED NDT INSPECTION ON TRIMMEDSDR 04FDEA00386Frame · scratchedFWD CABIN RT FRAME SCRATCHED AT STA 695 BETWEEN STR 12 & 13. REPAIR CARRIED OUT AS PER MD11 SRM 53-30-00 FIG 1 VOL 1. PERFORMED NDT INSPECTION ON TRIMMED AREA CRACK FREE CONDITION. FRAME DAMAGE REPAIRED BY SRM. REPETITIVE INSPECTION REQUIREMENT PER SRM - DTASDR 04FDEA00385Frame · dentedCABIN RT FRAME DENTED AT STA 1661 BETWEEN STR 12 & 13. CABIN RT FRAME DENTED AT STA 1661 BETWEEN STR 12 & 13 REPAIR CARRIED OUT AS PER MD11 SRM 53-30-00 FIG 1 VOL 1. PERFORMED NDT INSPECTION ON TRIMMED OUT AREA CRACK FREE CONDITION. FRAME DAMAGE REPAIRED BY SDR 04FDEA00384Frame · dentedCABIN LT SIDEWALL FRAME DENTED AT STA 1681 BETWEEN STR 12 & 13. CABIN LT SIDEWALL FRAME DENTED AT STA 1681 BETWEEN STR 12 & 13 REPAIR CARRIED OUT AS PER MD11 SRM 53-30-00 FIG 1 VOL 1. FUSELAGE FRAME DAMAGE REPAIRED BY SRM. REPETITIVE INSPECTION REQUIREMENT PESDR 04FDEA00383Frame · dentedCABIN LEFT FRAME DENTED AT STA 1521 BETWEEN STR 12 & 13. CABIN LT FRAME DENTED AT STA 1521 BETWEEN STR 12 & 13 REPAIR CARRIED OUT AS PER MD11 SRM 53-30-00 FIG 1 VOL 1. PERFORMED NDT INSPECTION ON TRIMMED OUT AREA CRACK FREE CONDITION. FUSELAGE FRAME DAMAGE RSDR 04FDEA00382Frame · dentedFUSELAGE FRAME DENTED AT STA 5-93 BETWEEN STR 12 & 13. REPAIR CARRIED OUT AS PER MD11 SRM 53-30-00 FIG 1 VOL 1. PERFORMED NDT INSPECTION ON TRIMMED OUT AREA CRACK FREE CONDITION. FUSELAGE FRAME DAMAGE REPAIRED BY SRM. REPETITIVE INSPECTION REQUIREMENTS PER SSDR MALA040207Frame · gougedFS 583.0 FRAME BETWEEN STR SL1501 AND 1601 GOUGED. CUT OUT DAMAGED AREA, FABRICATED AND INSTALLED A DOUBLER REPAIR IAW EO NR S53152. A/C RELEASE DATE 2/26/04. REFER LOG PAGE NR 1264969 FOR ADDITIONAL INFORMATION.SDR SWAA040384Frame · corrodedDURING SCHEDULED D CHECK, FOUND FRAME CORRODED AT BS 847, RBL 30 TO RBL 45. REPAIRED FRAME PER SRM.SDR AUS20040096Frame · cracked(AUS) FUSELAGE FRAME LOCATED AT RF 265-760 CRACKED IN AREA ADJACENT TO FLOORBEAM. FOUND DURING INSPECTION IAW AD/BEECH200/65.SDR ABXA040074Frame · crackedSTA 775 AFT OVERWHEEL WELL FRAME WAS CRACKED BETWEEN POINTS E AND E IN AFT OB POCKET AND CRACKED BETWEEN POINTS H AND I IN AFT IB POCKET AND CRACKED IN FORWARD IB POCKET BETWEEN FASTENERS THAT ARE LOCATED BETWEEN POINTS H AND I. FORWARD IB POCKET CRACK EMINASDR ABXA040072Frame · crackedEDDY CURRENT INDICATED LT MAIN FRAME AT FS 737 CRACKED AT AFT SIDE AT POINT J TO POINT G. REPAIRED IAW J.C. EA 53400110-001-2.SDR 04FDEA00368Frame · misrepairedCABIN - PREVIOUS FRAME REPAIR AT RIGHT STA 1541 STR 12 - 13 WAS FOUND SECURED WITH RIVETS, INSTEAD OF HI-LOKS. CABIN - PREVIOUS FRAME REPAIR AT RT STA 1541 STR 12 - 13 DOUBLER REMOVED AND REPLACED IAW SRM 53-30-00 FIG 1 VOL I WITH REF TO EA 1-5310-74305, FUSESDR 04036405Frame · corrodedDURING HEAVY INSPECTION FRAME 35 WAS FOUND WITH LEVEL 2 CORROSION. THE FRAME WAS REPLACED AND AIRCRAFT WAS RETURNED TO SERVICE UPON COMPLETION OF MAINTENANCE CHECK.SDR MALA040194Frame · corrodedDURING C-CHECK INSPECTION IN LCQ, AFT CARGO COMPARTMENT FRAME 34 CORRODED BEYOND LIMITS. MAINTENANCE REMOVED AND REPLACED FRAME 34 IAW BAE 146 RJ-85 SRM 51-24-11.SDR SWAA040348Frame · crackedDURING SCHEDULED D-CHECK, FOUND FORWARD CARGO COMPARTMENT FRAME CRACKED AT BS 492, STRINGER 24R. REPAIRED FRAME PER ER.SDR SWAA040346Frame · crackedDURING SCHEDULED D-CHECK, FOUND FRAME CRACKED AT BS 787, STRINGER 9L. REPAIRED FRAME SECTION PER ER.SDR SWAA040342Frame · crackedDURING SCHEDULED SPV, FOUND RT SIDE OF FUSELAGE WINDOW BELT FRAMES CRACKED AT BS 842, BS 822, BS 365, BS 385. REPAIRED WINDOW BELT FRAMES PER EA.SDR ASAA0440014Frame · corrodedAFT PIT STUB FRAME HAS CORROSION AROUND NUT PLATE BS 792 BL 18R. REPAIRED IAW SRM 51-40-02. (M)SDR A6WA200440017Frame · damagedFOUND FRAME 700 DAMAGED BETWEEN STRINGERS 16L AND 18L. REMOVED DAMAGED SECTION OF FRAME 700 FROM STRINGER 14L TO EXISTING SPLICE AT STRINGER 20L. FABRICATED SPLICE DOUBLER FROM 2024-T3 .040 INCH. INSTALLED SECTION OF FRAME P/N 600-360290-35 AND SPLICE DOUBLESDR SWAA040331Frame · crackedDURING SCHEDULED D CHECK, FOUND FRAME CRACKED AT BS 787, STRINGER 9R. REPAIRED FRAME PER ER.SDR SWAA040320Frame · crackedDURING SCHEDULED D CHECK, FOUND FRAME CRACKED AT BS 767, STRINGER 9L. REPAIRED FRAME SECTION PER ER.SDR SWAA040319Frame · crackedDURING SCHEDULED D CHECK, FOUND FRAME CRACKED AT BS 907, STRINGER 9R AND AT BS 907, STRINGER 9L. REPAIRED FRAME SECTIONS PER ER.SDR SWAA040318Frame · crackedDURING SCHEDULED D CHECK, FOUND FRAME CRACKED AT BS 867, STRINGER 9R. REPAIRED FRAME SECTION PER ER.SDR SWAA040317Frame · crackedDURING SCHEDULE D CHECK, FOUND FRAME CRACKED AT BS 807, STRINGER 9L. REPAIRED FRAME SECTION PER ER.SDR SWAA040316Frame · crackedDURING SCHEDULED D CHECK, FOUND FRAME INBOARD CHORD CRACKED AT BS 616, RBL 64, WL 202. REMOVED AND REPLACED FRAME SECTION PER ER.SDR SWAA040314Frame · crackedDURING SCHEDULED D CHECK, FOUND FRAME CRACKED AT BS 907, STRINGER 9L. REPAIRED FRAME PER ER.SDR SWAA040313Frame · crackedDURING SCHEDULED D CHECK, FOUND FRAME CRACKED AT BS 400, STRINGER 9L. REPAIRED FRAME SECTION PER ER.SDR SWAA040304Frame · crackedDURING SCHEDULED D CHECK, FOUND FRAME CRACKED AT BS 188, STRINGER 17L. REMOVED AND REPLACED FRAME SECTION PER SRM.SDR SWAA040303Frame · crackedDURING SCHEDULED D CHECK, FOUND FRAME CRACKED AT BS 328, BETWEEN STRINGERS 20R AND 21R. REMOVED AND REPLACED FRAME SECTION PER SRM.SDR UPS04841944Frame · corrodedINSPECTION TYPE:C3 RIGHT STATION 1723 SHEAR TIE AND FRAME SECTION ARE CORRODED BEYOND LIMITS BETWEEN LONG 30R AND 31R. REMOVED, FABRICATED AND REPLACED SHEAR TIE AND FRAME SECTION IAW SRM 53-5-3 FIG 3 AND 53-2-0 FIG 2.SDR SWAA040281Frame · crackedDURING SCHEDULED D CHECK, FOUND FRAME CRACKED AT BS 827, STRINGER 9L. REMOVED AND REPLACED FRAME SECTION PER SRM.SDR SWAA040279Frame · crackedDURING SCHEDULED D CHECK, FOUND R1 DOOR CUTOUT SUBFRAME CRACKED AT BS 303, RBL 56, WL 208. REMOVED AND REPLACED SUBFRAME SECTION PER SRM.SDR DL73S040099Frame · damagedBS 951 FRAME SUSTAINED DAMAGE IN THE RADIUS AT WL 203. DAMAGE WAS REMOVED AND REPAIRED PER ERA 386060-14.SDR 04FDEA00238Frame · corrodedN00260 CORROSION (C53-113-01(2)), AFT CARGO BAY, FRAME HAS CORROSION BY FASTENER COLLAR AT BS 1050 LBL 19 WL 150 (FASTENER COMMON TO FLOOR TO SIDEWALL SUPPORT AND FRAME) BLENDED CORROSION ON FRAME AT BS 1050 LBL 19 WL 150 IN AN AREA OF 3X1X.013 O.TSDR 04FDEA00235Frame · dentedFWD CARGO BAY, FRAME DENTED STA 660 STR 24 LT. CUT OUT DENTED MATERIAL FROM FRAME AT BS 660, STR 24L AND PER SRM 51-40-3, 53-10-1, USING 7075-T6, .050 LOT #466242. CUT OUT WAS 1X1SDR 04FDEA00236Frame · dentedFWD CARGO BAY, FRAME DENTED STA 680 STR 23 LT COMING CUT OUT DENTED MATERIAL 1 X 1 INCH FROM FRAME AT BS 680 STR 23L AND REPAIRED PER SRM 53-10-1, 51-40-3 USING 7075-T6 .050 LOT #466242.SDR 04FDEA00234Frame · dentedFWD CARGO BAY, FRAME DENTED STA 700 STR 23L. REMOVED DENTED MATERIAL FROM FWD CARGO BAY, FRAME AT BS 700, STR 23L, 24L AND REPAIRED PER SRM 51-40-3 USING 7075-T6 .050 LOT 466242, CUT OUT WAS 1X1 INCH.SDR SWAA040268Frame · crackedDURING SCHEDULED D CHECK, FOUND FRAME CRACKED AT BS 277, STRINGER 16 L. REPAIRED FRAME PER SRM.
Back to JASC 5311