JASC 5311
Service difficulty reports · 61,554
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR COMA0360370Frame · crackedFRAME ANGLE AT FS 718 CRACKED. COMPLIED WITH EA 10-5320-00236 AND S/B 601R-53-055 PART C.SDR COMA0360368Frame · crackedFRAME ANGLE AT FS 718 CRACKED. COMPLIED WITH EA 10-5320-00236 AND S/B 601R-53-055 PART B.SDR SWAA031783Frame · crackedDURING SCHEDULED D CHECK, FOUND FUSELAGE FRAME CRACKED AT BS 296, WL 208.5 AND RBL 55. REPAIRED FRAME PER SRM.SDR SWIA200312405Frame · crackedRT FRAME 9 CRACKED BY FO'S O2 STORAGE BOX, UPPER RADIUS. (DISCOVERED DURING C-CHECK INSPECTION) COMPLIED WITH SERVICE BULLETIN NR 120-53-0073 IAW EMB SRM 51-40-00 THRU 51-40-08.SDR UPS03841184Frame · corrodedINSPECTION TYPE: C1, CORROSION ON FRAME FS 1340 S36L. REMOVED CORROSION IAW DC8 SRM 51-1-8, ORIG THICK 0.080, LOSS .020 REM. MATERIAL .060, FOUND OUT OF LIMITS IAW DC8 SRM 53-4-1, 51-2-0, & 53-2-0.FAB BED ANGLE REPAIR (7075-0, 0.080, PO 312487.0) IAW DC8 T/R NSDR CALA0300455Frame · corrodedINSPECTION FOUND CHORD CORRODED AROUND NUTPLATE HOLE AT FS 967, LBL 42. AN UPPER CHORD REPAIR WAS INSTALLED IAW SRM 53-00-51.SDR UPS03841182Frame · corrodedINSPECTION TYPE: C1, MAIN CABIN LT SIDE AT STA 1140 FWD SIDE 4 INCH ABOVE CUSP FRAME HAS CORROSION. REMOVED CORROSION, AREA IS OUT OF LIMITS IAW DC8 SRM 53-2-0, FABRICATED REPAIR IAW DC8 SRM 53-2-0, ALODINED AND PRIMED IAW DC8 SRM 51-1- 8, AND INSTALLED REPASDR USAA030143Frame · crackedPIT - FOUND FRAME CRACKED .5 INCH, FS 400 S8R AND S9R AT PSU SUPPORT BRACKET. INSTALLED DOUBLER PER SRM 53-10-20A. (M)SDR SWAA031777Frame · crackedDURING SCHEDULED 1/2D CHECK, FOUND FUSELAGE FRAME CRACKED AT BS 363, BETWEEN STR 13R AND STR 14R. REPAIRED FRAME PER SRM.SDR 03FDEA01223Frame · bentFWD CARGO BAY 680 FRAME BENT AT RBL 35 BETWEEN STR 24R+25R.SDR 03FDEA01219Frame · bentFWD CARGO BAY 680 FRAME BENT AT RBL 35 BETWEEN STR 24R & 25R. FRAME AT BS 680, RBL 35 BETWEEN STR 24 & 25 RT OUT OF LIMITS. REPAIRED FRAME IAW FEDEX EA 7-5310-72507, SRM 53-10-1 & 51-40-3 FIG 1.SDR CALA0300445Beltframe · crackedINSPECTION FOUND A 2 INCH CRACK IN BELTFRAME AT STA 807 BETWEEN S27L AND S27R. A REPAIR ANGLE WAS INSTALLED IAW SRM 53-00-07.SDR HNAA0300038Frame · corrodedDURING 40K INSPECTION FRAME LEG WAS FOUND WITH CORROSION AT STATION X510 AND BETWEEN STR 32S AND STR 31S. A NEW FRAME WAS SPLICED IN AS PER EO 8-53-03-0782.SDR SWAA031767Frame · crackedDURING SCHEDULED D CHECK, FOUND FUSELAGE FRAME CRACKED AT BS 480, BETWEEN STR 8R AND STR 9R. REPAIRED FRAME PER BFG ER.SDR SWAA031757Frame · crackedDURING SCHEDULED D CHECK, FOUND FUSELAGE FRAME CRACKED AT BS 887, BETWEEN STR 8R AND STR 9R. REPAIRED FRAME PER SRM.SDR SWAA031756Frame · crackedDURING SCHEDULED D CHECK, FOUND FUSELAGE FRAMES CRACKED (4 EA) BETWEEN STR 8L AND STR 9L, BS'S 827, 867, 887 AND 907. REPAIRED FRAMES PER SRM.SDR SWAA031746Shear Tie · corrodedDURING SCHEDULED 1/2D CHECK, FOUND SHEAR TIE CORRODED AT BS 363, BETWEEN STR 14R AND STR 15R. REPAIRED SHEAR TIE PER SRM.SDR SWAA031744Frame · corrodedDURING SCHEDULED D CHECK, FOUND FUSELAGE FRAME CORRODED AT BS 847, BETWEEN STR 22R AND STR 23R. REPAIRED FRAME PER SRM.SDR USAA030157Frame · crackedFOUND FRAME CRACKED AT RIVET, STATION 440 S8L AND S9L FRAME. CUT OUT DAMAGED AREA AND INSTALLED DOUBLERS PER TYP REP 53-10-20A. (M)SDR USAA030140Frame · corrodedPIT - FOUND CHORD CORRODED 8 INCHES BY 2 INCHES, BS 1016 BETWEEN STRINGERS 26L AND 26R. REMOVED CORROSION AND INSTALLED REPAIR PER SRM 53-00-01 AND BOEING DWG 65C28106. CORROSION LEVEL 2, TASK NR C53-208-01. (M)SDR SWAA031727Frame · crackedDURING SCHEDULED D CHECK, FOUND FUSELAGE FRAME CRACKED AT BS 1091, WL 285 AND LBL 38. REMOVED AND REPLACED FUSELAGE FRAME SECTION PER SRM.SDR C2XA03SH255Frame · corrodedDURING C-CHECK, THE DOUBLER AT FRAME 22 WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFFECTED DOUBLER IAW EMB 145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA03SH254Frame · corrodedDURING C-CHECK, THE DOUBLER AT FRAME 20 WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFFECTED DOUBLER IAW EMB 145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA03SH251Frame · gougedSHV-DURING C CHECK FRAME 81 WAS FOUND TO BE GOUGED. MAINTENANCE REMOVED THE DAMAGED AREA AND PERFORMED A DOUBLER REPAIR IAW EC 5310-01246. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR SWAA031720Frame · crackedDURING SCHEDULED D CHECK, FOUND FUSELAGE FRAME CRACKED AT BS 663, STR 3R. REPAIRED FRAME PER SRM.SDR 03FDEA01197Splice · crackedLEFT MLG WHEEL, AFT END, OUTBOARD WALL, FRAME REPAIR IS CRACKED. CLOSING ACTION ON 07/19/03. FOUND CRACK IN FRAME REPAIR. REMOVED IAW SRM 53-33-01 FAB NEW SPLICE IAW GMM 7-0-1-001 SECTION 3C FROM 7070-T6 .125C. INSTALLED NEW SPLICE IAW SRM 31-33-01.SDR C2XA03SH244Frame · corrodedDURING C-CHECK, FOWARD DIGITAL BUTTSTRAP WAS FOUND TO HAVE CORROSION AT FRAME 15. MAINTENANCE REMOVED DAMAGE AND REPAIRED AFFECTED AREA IAW EMB 145 SRM 53-21-10. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.SDR MALA030362Frame · corrodedDURING 4K INSPECTION IN CWA, UPPER FLANGE ON BOTTOM FUSELAGE FRAME STA 294 HAS CORROSION RBL 30.5 MAINTENANCE REPAIRED DAMAGE IAW EO NR $53108. REFER TO 409 NR 192516 FOR DETAIL. A/C RELEASE DATE 7/31/03.SDR MALA030389Frame · corrodedDURING C CHECK INSPECTION IN CVG, MAINTENANCE FOUND FLOOR FRAME 18 BETWEEN NR 3 & NR 4 SEATRAILS WITH CORROSION. REPAIRED IAW EO NR A53126. A/C RELEASE DATE 8/11. REFER TO 409 NR 128559 FOR DETAIL.SDR SWAA031679Frame · crackedDURING SCHEDULED D CHECK, FOUND FUSELAGE FRAMES CRACKRD (2 EA) AT BS 500, WL 148 AT RBL 8 AND BS 827, WL 148 AT RBL 3. REPAIRED FRAMES PER SRM.SDR SWAA031678Shear Tie · crackedDURING SCHEDULED D CHECK, FOUND SHEAR TIE CRACKED AT BS 294, STR 11L. REMOVED AND REPLACED SHEAR TIE PER SRM.SDR 03FDEA01156Frame · damagedDAMAGED FASTENER HOLE ON FRAME AT BS 1070, LBL 22, WL 152. DAMAGED FASTENER HOLES ON FRAME AT BS 1070, LBL-22, WL-152 FOUND TO BE OUT OF LIMITS PER SRM 53-10-1, CUT OUT DAMAGED MATERIAL AND REPAIRED IAW SRM5 1-40-3, FED- EX EA 7-5310-54913.SDR 03FDEA01154Frame · damagedELONGATED FASTENER HOLE AT B/S 1070, 1050, 1110, LBL-22, WL-152. REPAIRED FRAME AT B.S. 1070, 1050, 1110, LBL 22 (WL 152) IAW SRM 51-40-3 AND EA 7-5310-54911.SDR 03FDEA01155Frame · damagedDAMAGED FASTENER HOLES ON FRAME AT BS 1110, LBL 22, WL 152. CUT OUT MATERIAL FROM FRAME THAT HAD DAMAGED FASTENERS HOLES AT BS 1110, LBL 22, WL 152. FABRICATED REPAIR FROM HFAB53-FR-011, AND INSTALLED ALL IAW SRM 53-10-1, 51- 40-3, 51-30-5, 51-30-2, AND 51SDR UPS03841110Frame · corrodedINSPECTION TYPE: C2, MAIN CABIN CANTED FRAME IS CORRODED BEYOND LIMITS AT STA 1746 AT LONG 26L. REMOVED CANTED FRAME BETWEEN LONG 26L TO 36, FABRICATED AND INSTALLED FRAME AND SPLICES IAW DWG 5612148 AND SRM 53-2-0 FIG 2.SDR EIA2003105Frame · crackedBS 1000 BULKHEAD FRAME CRACKED AT S-38L. CRACK VERIFIED WITH HFEC S/N J032592, CAL DUE 4-21-04. CRACK LENGTH APPROXIMATELY .75 INCH. REPAIRED PER ECRA 485-53-157-2.SDR EIA2003102Frame · crackedFRAME CRACKED, INTERIOR FUSELAGE STA 300L, BELOW S-25L, OUTBOARD NEAR SKIN. REMOVED AND REPLACED FUSELAGE FRAME AT FS 300L, STR 23-41, PER SB 747-53-2272, PER -B-DRAWINGS 141U1021 AND 65B1708 & ECRA 485-53-152-2.SDR C2XA03TY100Frame · bentON GROUND WITH GUSTLOCK ENGAGED, AIRCRAFT EXPERIENCED WINDS GUSTING 54+KTS. GUSTLOCK DISENGAGED. MAINTENANCE INSPECTED THE SYSTEM AND FOUND THE FRAME JUST FORWARD OF THE GUSTLOCK ASSY IN THE FORWARD FUSELAGE UNDER THE COCKPIT CENTER PEDESTAL BENT. MAINTENANSDR UPS03441128Frame · corrodedINSPECTION TYPE:C RT TUNNEL TORQUE BOX STA 340 IN BETWEEN STR 42 AND STA 43 CHORD FOUND CORRODED. THE CORD REPLACED IAW SRM 51-10-01 P8. (CORROSION REMOVED - BLEND OUT DEPTH 0.050 WIDTH 1 INCH LENGTH 1 INCH OUT OF SRM 53-10-01 FIG 1 LIMITS.SDR UPS03441079Frame · crackedINSPECTION TYPE:C FESC-LT STA 410 LBL 8- LBL 16 WEB FOUND CRACKED. FESC LT STA 410 LBL 8- LBL 16 FRAME WEB CRACK TRIMMED OFF IAW SRM 51-10-01 AND REPROTECTED IAW SRM 51-10-02.SDR SWAA031650Frame · crackedDURING SCHEDULED D CHECK, FOUND FUSELAGE FRAME CRACKED AT BS 360, STR 20R. REPAIRED FRAME PER SRM.SDR SWAA031624Frame · crackedDURING SCHEDULED D CHECK, FOUND BOTH LT AND RT OUTBD FRAMES CRACKED AT BS 188, WL 207. REMOVED AND REPLACED BOTH LT AND RT FRAMES PER SRM.SDR 03FDEA01122Frame · damagedTEMPORARY REPAIR ON FRAME20A. PERMANENT REPAIR INSTALLED IAW EA 6-5310-60187 A AND DWG SR30-53-001.SDR GAIA03032SPFrame · dentedDURING C-CHECK, FOUND MAIN CABIN FRAME BS 360 HAS DENTS INTO THE RADIUS BETWEEN STRINGER 15L AND 17L FASI N/R 35752. CUT OUT DAMAGES AREAS, FABRICATED REPAIR DOUBLER, MATERIAL USED 7075-T6 .063 PO NR 9912571 DIM 18.5 INCH BY 6.5 INCH. TWO ATTACH ANGLES P/N BSDR GAIA03026SPFrame · dentedDURING C-CHECK, MAIN CABIN FRAME BS 720 HAS A DENT INTO THE RADIUS BELOW STRINGER 16R. REMOVED FASTENERS AND CUT OUT DAMAGED AREA OF FRAME, FABRICATED REPAIR DOUBLER IAW B727 SRM 53-10-4 FIG 1, MAT USED .050 7075-T6 P/O NR 9911488 DIM 10 INCH BY 5 INCH. INSTSDR GAIA03029SPFrame · dentedDURING C-CHECK, FOUND MAIN CABIN FRAME BS 520 HAS A DENT INTO THE RADIUS AT STRINGER 16R FASN/R 35745. CUT OUT DAMAGED AREA, FABRICATED FILLER FROM MATERIAL 7075-T6 .050 PO NR 991420, DIM 2.5 INCH BY 3 INCH, DOUBLER FROM MATERIAL 7075-T6 .063, PO NR 9912495 DSDR GAIA03028SPFrame · dentedDURING C-CHECK, FOUND MAIN CABIN FRAME BS 540 HAS DENT INTO THE RADIUS AT STRINGER 16 RT, FASI N/N 35744. CUT OUT DAMAGED AREA, FABRICATED SECTION OF FRAME MATERIAL USED 7075-T6 .063 P/O NR 991245 DIM 12 INCHES BY 3.5 INCHES, DOUBLER 7075-T6 .071 P/O NR 99120SDR GAIA03027SPFrame · dentedDURING C-CHECK, FOUND MAIN CABIN FRAME BS 600 HAS A DENT INTO THE RADIUS AT STRINGER 16R. CUT OUT DAMAGED AREA OF FRAME. FABRICATED NEW SECTION OF FRAME, MAT USED 7075-T6 .050 P/O NR 991420 DIM 12 INCH BY 5 INCH, AND FILLER MAT USED 7075-T6 .050 P/O NR 9914SDR GAIA03034SPFrame · dentedDURING C-CHECK, FOUND MAIN CABIN FRAME BS 560 HAVE DENTS INTO THE RADIUS AT STRINGER 16R AND STRINGER 8R FASI N/R 35743. CUT OUT DAMAGED AREAS, FABRICATED DOUBLERS FROM MAT 7075-T6 .063 PO NR 9912495, DIM 7 INCH BY 4.5 INCH AND 10 INCH BY 3 INCH. INSTALLED DSDR GAIA03031SPFrame · crackedDURING C-CHECK, FOUND MAIN CABIN FRAME BS 360 HAS A DENT AND CRACK BETWEEN STRINGERS 7R AND 8R FASI N/R 35751. CUT OUT DAMAGED AREA, FABRICATED DOUBLER REPAIR FROM 7075-T6 .050, PO NR 9911488 DIM 11 INCH BY 5.5 INCH. INSTALLED REPAIR IAW B727 SRM 51-30-2 AND
Back to JASC 5311