JASC 5311
Service difficulty reports · 61,554
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GAIA03030SPFrame · damagedDURING C-CHECK, FOUND MAIN CABIN FRAME BS 460 HAS A TOOLING HOLE INTO THE RADIUS AT STRINGER 17R FASI N/R 35747. CUT OUT DAMAGE AREA, FABRICATED DOUBLER FROM 7075-T6 .063 PO NR 9912495 DIM 3.5 INCH BY 7.75 INCH, INSTALLED REPAIR IAW B727 SRM 51-30-2. (M)SDR GAIA03045SPFrame · dentedDURING C-CHECK, FOUND MAIN CABIN FRAME BS 580 HAS A DENT AT STRINGER 16 RT, FASI N/R 36051. CUT OUT DAMAGE 1 INCH BY 1.5 INCH, REPAIR DOUBLER 7075 T-6 INSTALLED IAW B-727 SRM 51-40-3 FIG 1. (M)SDR UPS03441122Frame · crackedINSPECTION TYPE:C M/D- BS 380 STR 25L FRAME CRACKED. FRAME REPLACED AS PER SB747-53-2272 DWG 624U0003 FROM S23L TO S44L AT BS380.SDR UPS03441055Frame · corrodedINSPECTION TYPE: C, FX - BODY FAIRING SUPPORT FRAME FOUND SURFACE CORROSION AT STA 920 FROM RBL 20 - 50. CORROSION BLEND OUT 0.056 X 1 X 1.5 INCH. BODY FAIRING SUPPORT FRAME REPAIRED AS PER SRM 53-50-04 FIG 2 AT STA 920 FROM RBL 0 - RBL 30 AREA. BODY FAIRINSDR UPS03441053Frame · corrodedINSPECTION TYPE: C, FX - BODY FAIRING SUPPORT FRAME FOUND SURFACE CORR AT STA 1050, RBL 22 - 25 AND RBL 50 - 60 AS MARK. FX - BODY FAIRING SUPPORT FRAME STA 1050 RBL 22 - 25 SURFACE CORROSION AREA CORROSION CLEANED AS PER SRM 51-10-01 AND REPROTECTED AS PER SDR DL73S030665Frame · crackedFUSELAGE SKIN STA 663, S2R TO S1 - MISALIGNMENT: DURING INSPECTION OF THE FS 663 FRAME, MTC FOUND CRACKS IN THE FRAME AT S2R AND S1R. THESE WERE WITHIN THE AREA ADDRESSED BY B737-200 SRM 53-10-4, FIG 14. DURING INSTALLATION OF SRM FRAME REPAIR, SKIN ATTACH SDR AUS20030736Frame · cracked(AUS) FUSELAGE FRAMES CRACKED AT PSU ATTACHMENT POINTS. FOUR FRAMES ONTHE LT SIDE AND THREE FRAMES ON THE RT SIDE CRACKED. FOUND DURING EDDY CURRENT INSPECTION IAW EI 737-53-68R1 AND NDT TECHNIQUES E-13 AND E-18.SDR SWAA031576Frame · crackedDURING SCHEDULED SPECIAL VISIT, FOUND FUSELAGE FRAME CRACKED AT BS 380, STR 16L. REPAIRED FRAME PER SRM.SDR USAA030163Frame · crackedFOUND FRAME CRACKED 1 INCH LONG, FS 601, LEFT SIDE BELOW CABIN FLOOR, THROUGH 2 FASTENERS. DAMAGE CUT OUT, FILLER AND DOUBLER INSTALLED PER EA 76450. (M)SDR USAA030139Frame · crackedPIT - FOUND FRAME CRACKED APPROX 1 INCH, CRACKED THROUGH 2 FASTENERS, FRAME 601, LEFT SIDE JUST BELOW CABIN FLOOR. DAMAGE CUT OUT, FILLER AND DOUBLER INSTALLED PER EA 76450. (M)SDR 2003UALA00565Frame · puncturedAFT PIT FRAME HAS 3 INCH PUNCTURE STA 1351, STR 24R TO 25R. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED DOUBLER REPAIR.SDR SWAA031560Shear Tie · corrodedDURING SCHEDULED D CHECK, FOUND SHEAR TIE CORRODED AT BS 787, WL 148 AND RBL 9. REPAIRED SHEAR TIE PER SRM.SDR SWAA031580Frame · crackedDURING SCHEDULED C3 CHECK, FOUND T-CHORD CRACKED AT TOP NOSE WHEEL WELL FWD CENTER BEAM AT BS 230. REMOVED AND REPLACED T-CHORD AND WEB PER SRM.SDR CALA0300387Frame · crackedINSPECTION FOUND A .5 INCH CRACK IN RT MAIN FRAME ANGLE AT STA 616 FLOOR LINE. A STIFFENING ANGLE REPAIR WAS INSTALLED IAW ECRA 5311-01157.SDR SWAA031537Frame · crackedDURING SCHEDULED D CHECK, FOUND RT BS 188 CHORD CRACKED AT WL 207. REMOVED AND REPLACED CHORD PER SRM.SDR DL73G030647Frame · crackedFUSELAGE BULKHEAD FS 178 SIDE CHORD WL 207 : CRACK REPAIR, THE LT SIDE CHORD OF THE FS 178 BULKHEAD WAS FOUND WITH A 1 INCH CRACK AT WL 207. THE CRACK IS TYPICAL OF BAC S/B 737-53 -1173 AND AD 2000-05-29. THE CRACKED SECTION OF CHORD WAS REMOVED AND A NEW SDR AWXA200300897Frame · crackedMCN - MAJOR REPAIR - DURING C-14 CHECK A .5000 INCH CRACK WAS FOUND ON BS 178 BULKHEAD RT SIDE CHORD JUST ABOVE WL 207. MAINTENANCE REMOVED BS 178 BULKHEAD RT SIDE CHORD AT WL 207; FABRICATED A NEW REPLACEMENT SIDE CHORD; INSTALLED REPAIR PART IAW B737-300 SRMSDR UPS03241049Frame · crackedINSPECTION TYPE: C, FRAME CRACKED AT BS 1070 AND ATTACH POINT FOR AFT LWR CARGO DOOR. CRACKED FRAME AT BS 1070 REMOVED AND NEW FRAME INSTALLED IAW DRAWING NR65-18622.SDR AWXA200300850Frame · crackedDURING C-14 CHECK A .25 INCH CRACK WAS FOUND ON FRAME AT BS 616, LBL 65, WL 200. MAINTENANCE CUT OUT CRACK ON FRAME AT BS 616, LBL 65, WL 200; PERFORMED A HFEC INSPECTION TO VERIFY NO CRACKS EXIST; FABRICATED A FILLER AND REPAIR ANGLE; INSTALLED REPAIR PARTS SDR AWXA200300827Frame · crackedDURING C-14 CHECK A 1 INCH CRACK WAS FOUND ON FRAME INNER CHORD AT BS 616, RBL 45, WL 200. MAINTENANCE CUT OUT CRACK ON FRAME INNER CHORD AT BS 616, RBL 45, WL 200; PERFORMED A HFEC INSPECTION TO VERIFY NO CRACKS EXIST; FABRICATED A STIFFENING ANGLE AND FILLESDR 2003FA0000757Frame · corrodedFRAME HAS SEVERE RUST PITTING ON FRAME TUBING BOTTOM LEFT AND RIGHT SIDES FORWARD OF WELDED CLUSTER. PITTING AREA APPROXIMATELY 1 INCH LONG ALL AROUND TUBING. CAUSE UNKNOWN, HOWEVER THIS IS INBOARD AND AFT OF FLAP AREA. NOTED CONDITION WHEN FLOOR REMOVED FSDR 03FDEA01103Frame · crackedCENTER CARGO DOOR CUT OUT LOWER AFT CORNER FOUND ROLLER TRAY SUPPORT CHORD CRACK. ***** S/D COMING ****SDR AALA20030802Frame · corrodedFOUND FRAME WEB AT STATION 1562 BL 0 HAD CORROSION BLENDED FROM SIDE. REQUEST ENGINE APPROVAL TO CONTINUE AS IS. ALODINED 2 COATS OF PRIMER. BLEND OUT CORROSION AND VERIFY CORROSION HAS BEEN COMPLETELY REMVOED. REFINISH BLENDED AREA WITH ALODINE AND TWO COSDR DHL2003604675Frame · brokenAFT CARGO COMPT. DOOR NR 4 FRAME ANGLE BROKEN, STA.1440.000. REMOVED BROKEN ANGLE IAW SRM 51-3-0 PG.1. FABRICATED NEW ANGLE (2024-T3 AL0.040) IAW SRM 53-2-0 PG.1-2. CLEANED, TREATED AND PRIMED AREA AND NEW ANGLE IAW SRM 51-1-8B. INSTALLED NEW ANGLE IAW SRM 51-SDR CALA0300370Frame · crackedINSPECTION FOUND A 1 INCH CRACK IN LT MAIN FRAME ANGLE AT STA 616 BELOW FLOOR LINE, WL 200. REPAIRED FRAME IAW ECRA 5311-01154.SDR ASOA03295Frame · crackedDURING A C-CHECK IN MCN, THE RIGHT SIDE FRAME FS 718 BETWEEN STRINGERS 10 TO 11 WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE REPAIRED THE RIGHT FRAME FS 718 BETWEEN STRINGERS 10 TO 11 IAW ASA EO 600-53-0066. (M)SDR UPS03841031Frame · corrodedINSPECTION TYPE: C2, FRAME CORRODED AT STA 1420 AT L25R ABOVE D-PIT DOOR OPENING. REMOVED CORROSION IAW DC8 SRM 51-1-8. AREA OUT OF LIMITS IAW DC8 SRM 53-2-0. FABRICATED FRAME REPAIR DOUBLER IAW UPS EO DC8-5310-11728. ALODINED AND PRIMED IAW DC8 SRM 51-1SDR DHL2003873565Frame · crackedAFT ACCY COMPT FORMER CRACKED 1.000 STA 640.000 BETWEEN L-26L AND L-27L. REMOVED FASTENERS IAW SRM 51-1-21 PG 1. PERFORMED STOP HOLE ON CRACK END IAW SRM 53-2-0 FIG 1B. FABRICATED DOUBLER IAW SRM 53-2-0 FIG 1B. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. SDR 03FDEA01029Frame · dentedFRAME DENTED BS 500 STR 24L. REPAIRED DENTED FRAME AT BS 500, STR 24L PER SRM 51-40-3.SDR 03FDEA01033Frame · dentedFRAME DENTED BS 540 STR 24L. CUT OUT DENTED SECTION OF FRAME STR 24L BS 540 2.2 X 1 X .050 INCH. FABRICATED REPAIR AND INSTALLED IAW SRM 51-40-3.SDR 03FDEA01036Frame · dentedAFT CARGO BAY BS 990 FRAME IS DENTED AT STR 26L. REPAIRED FRAME AT BS 990, STR 26L PER SRM 51-40-3, FIG 1.SDR 03FDEA01035Frame · dentedFRAME DENTED BS 580 BETWEEN STR 23L TO STR 5L. CUT OUT DAMAGED AREA ON BS 580 FRAME, 2 AREAS BETWEEN STR 23L AND 25L, 1.4 X 1 AND 3.8 X 1 INCH. FABRICATED REPAIR DOUBLER. ALODINED, PRIMED AND INSTALLED PER FED EX SRM 51-40-3.SDR 03FDEA01034Frame · dentedFRAME DENTED BS 560 STR 22L TO 24L. REMOVED DAMAGED AREA OF DENTED FRAME BS 560, STR 22L TO 24L. FABRICATED, ALODINED, PRIMED AND INSTALLED REPAIR PART. ALL IAW SRM 53-10-1 FIG 1, 51-40-3 FIG 1, 51-20-04 PGS 3 AND 4, FED EX MM 51-20-000-7.SDR 03FDEA01032Frame · dentedFRAME DENTED BS 520 STR 24L. INSPECTED DENTS AT BS 520, STR 24L. FOUND TO BE OUT OF LIMITS PER SRM 53-10-1, FIG 1, DETAIL II, NOTE [S]. CUT OUT AND REPAIRED DAMAGE PER SRM 51-40-3, FIG 1.SDR 03FDEA01038Frame · dentedAFT CARGO BAY BS 950F FRAME IS DENTED IN 3 PLACES BETWEEN STR 26L AND 25L. REPAIRED FRAME AT BS 950F BETWEEN STRS 25L & 26L PER SRM 51-40-3 FIG 1.SDR 03FDEA01037Frame · dentedAFT CARGO BAY BS 970 FRAME IS DENTED AT STR 26L AND 25L AND 23L. REPAIRED FRAME AT BS 970, STR 25L - 26L AND STR 23L PER SRM 51-40-3 FIG 1.SDR 03FDEA01031Frame · dentedFRAME DENTED BS 500 STR 22R. FRAME AT BS 500, STR 22R DENT OUT OF LIMITS PER SRM 53-10-1. REPAIRED FRAME PER SRM 51-40-3.SDR 03FDEA01030Frame · dentedFRAME DENTED BS 520 STR 22R TO 24R. REPAIRED FRAME BS 520, STR 22R TO 24R PER SRM 51-40-03.SDR MALA030356Frame · crackedDURING C-CHECK INSPECTION IN CVG, FLOOR FRAME 18 UPPER SURFACE HAS MULTIPLE CRACKS AND CORROSION, FROM 3.2500 INCH RIGHT OF NR 3 SEAT RAIL AND ENDS UNDERNEATH NR 4 SEAT RAIL. MAINTENANCE REPAIRED IAW EO NR A53124, REFER TO 409 NR 128103 FOR FURTHER DETAIL. A/SDR SWAA031477Frame · crackedDURING SCHEDULED SPECIAL VISIT, FOUND FUSELAGE FRAME CRACKED AT BS 500D, STR 12L. REPAIRED FRAME PER SRM.SDR SWAA031476Frame · crackedDURING SCHEDULED SPECIAL VISIT, FOUND FUSELAGE FRAME CRACKED AT BS 520, STR 13R. REPAIRED FRAME PER SRM.SDR SWAA031463Frame · crackedDURING SCHEDULED A2 CHECK, FOUND FUSELAGE FRAME CRACKED AT BS 440, STRINGER 24R. REPAIRED FRAME PER BFG ER.SDR ASOA03306Frame · crackedDURING HANGAR MAINTENANCE AT CKB, THE FRAME SECTOR AT FS 640 ON THE RIGHT SIDE BELOW STRINGER 9R WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE REPAIRED THE FRAME SECTOR AT FS 640 ON THE RIGHT SIDE BELOW STRINGER 9R IAW ASA EO 600-53-0075. (M)SDR ASOA03299Frame · crackedDURING HANGAR MAINTENANCE AT CKB, THE FRAME SECTOR AT FS 640 BELOW STRINGER 9 ON THE LT SIDE WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE REPAIRED THE FRAME SECTOR AT FS 640 BELOW STRINGER 9 ON THE LT SIDE IAW ASA EO 600-53-0075. (M)SDR MWEA030263Frame · crackedFRAME WEB STATION 1463 AT LONGERON 181 IS CRACKED. FABRICATED AND INSTALLED NEW WEB AND DOUBLER.SDR C2XA03SH211Frame · corrodedDURING C-CHECK, THE DOUBLER AT FRAME 20 WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFFECTED DOUBLER IAW EMB 145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR GTIA030587Frame · corrodedFTW - FOUND RIGHT AFT LAVATORY FLOOR STATION 1338 STRINGER 18 CORRODED. REMOVED 9 HI-LOCKS AND 1 GUSSET. FABRICATED NEW GUSSET. FOUND FRAME AT FS 1338 AND 18R TO BE CORRODED BEYOND LIMITS. FABRICATED NEW FRAME REPAIR SECTION, AND FABRICATED SPLICE SECTION. SDR SWAA031443Frame · crackedDURING SCHEDULED D CHECK, FOUND FUSELAGE FRAME CRACKED AT BS 663.75, BETWEEN STR 2L AND 3R. REPAIRED FRAME PER SRM.SDR CALA0300376Frame · crackedMAINTENANCE FOUND THE INNER CHORD ON THE LT FRAME AT STA 616 CRACKED. THE AREA WAS REPAIRED IAW ECRA 5311-01154.SDR DHL2003720007Frame · corrodedDURING PRE-DEPARTURE CHECK, FOUND CORROSION ON LT BS 950 MAIN FRAME, WL 189, LWBL 70.5, AS VIEWED FROM LT WHEEL WELL. TRANSFERRED TO LOG PAGE 348951 ITEM 1M DUE TO FERRY FLIGHT IAW DHL GMM 2.12. REF LOG PAGE 341424 ITEM 8M REMOVE CORROSION AT LT STA 950 FRAM
Back to JASC 5311