JASC 5313
Service difficulty reports · 36,303
Reports filed under 5313 · Fuselage Main, Longeron/Stringer, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5313' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5313' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA202163398None · corroded*CORROSION ON INTERCOSTAL BETWEEN STGR 26R - 27, FS 349.00 - 364.00 (C CHECK RO 12-31-21) / REPLACED INTERCOSTAL BETWEEN STGR 26R AND 27 FROM FS349.00 TO FS364.00. REF CRJ900 SRM 51-42-06-001-001-A01, CRJ900 SRM 51-42-21-001-001-A01, AND DWG SH670-32050 RSDR SWIA202163397None · corroded*CORROSION ON INTERCOSTAL ATTACHED TO STGR 26R BETWEEN FS 349.00 - 364.00 (C CHECK RO 12-31-21) / REPLACED INTERCOSTAL ATTACHED TO STGR 26R BETWEEN FS349.00 TO FS364.00 REF CRJ900 SRM 51-42-06-001-001-A01, CRJ900 SRM 51-42-21-001-001-A01 AND DWG SH670-320SDR SWIA202163383None · corrodedR/H SIDE BELOW FLOOR BETWEEN FS 319.70 TO FS 310.0 INTERCOSTAL HAS CORROSION AT STR 20R (C CHECK RO 12-31-21) REPLACED RH SIDE BELOW FLOOR BETWEEN FS319.7 TO FS310.0 INTERCOSTAL AT STR 20R REF CRJ900 SRM 51-42-06-001-001-A01, DWG SH670-31950 REV. Y. COMPLISDR SWIA202163382None · corrodedFS 280 AT APPROX STR20L THERE IS CORROSION ON CIRCUFRENTIAL STRAP. (C CHECK RO 12-31-21) REMOVED CORROSION AT FS280 (FS333.00 CIRCUMFERENTIAL JOINT) REF CRJ-900 SRM 51-21-06-001-001-A01. EVALUATED AND FOUND TO BE WITHIN LIMITS REF. CRJ 900 SRM 53-00-01-101SDR SWIA202163381None · corrodedUNDER FLOOR AT STR21L IN BETWEEN FS 333. TO FS 349.0 INTERCOSTAL HAS CORROSION. (C CHECK RO 12-31-21) REPLACED UNDERFLOOR AT STR 21L INTERCOSTAL (BACK-UP SILL) REF CRJ900 SRM 51-42-06-001-001-A01 AND DWG SH670-31810 REV.AE. COMPLIED WITH 51-900-1002-SKY.SDR SWIA202162825None · corrodedEVIDENCE OF CORROSION ON PLATE BRACKET AT INTERCOSTAL BETWEEN STGR 22L AND STGR 23L, BETWEEN FS533.00 AND FS534.00 INTERNAL SURROUND STRUCTURE OF FORWARD BAGGAGE BAY DOOR. (C-CHECK RO 11-24-21) BLENDED CORROSION ON PLATE BRACKET BETWEEN STGR 22L AND STGR23SDR MASA20211105526Stringer Splice · corrodedSTRINGER SPLICE 27 AT FS333 CORRODED |R&R STRINGER SPLICE 27SDR SWAA2021120740612Tie Clip · crackedSUPPLEMENTAL INFORMATION: CRACK TIE CLIP LOCATED BS 277 AND STR 10R AT PASSENGER CABIN ; 2021-511908 / [01] REPLACED TIE CLIP LOCATED BS 277 AND STR 10R AT PASSENGER CABIN IAW B737-700 SRM 51-10-02 AND DRAWING 141A1110 REV - AND DRAWING 141A8380 REV -; [02] RESDR SWAA2021120340484Stringer · crackedCRACKED STRINGER AT AREA AFT OF FCB BS540 S-23R WL164. MARKED ; / [01] EVALUATED CRACK MEASUREMENTS ON FCB STR 23R BS 536 ; STRINGER DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-00-03-1A-1 FIG 103; [28] REPAIRED STRINGER 23R; BETWEEN STA 500D - 540; INSTALLED ASDR SWAA2021120340483Stringer · crackedCRACKED STRINGER AT AREA AFT OF FCB BS540 S-26R WL153. MARKED ; / [01] EVALUATED CRACK MEASUREMENTS ON FCB STR 26R BS 536 ; STRINGER DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-00-03-1A-1 FIG 103; [18] REPAIRED STRINGER 26R; BETWEEN STA 500D - 540; WL 153. IAWSDR SWAA2021120340476Stringer · crackedCRACKED STRINGER AT AREA AFT OF FCB BS540 S-26L WL153. MARKED ; / [01] EVALUATED CRACK MEASUREMENTS ON FCB STR 26L BS 536 ; STRINGER DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-00-03-1A-1 FIG 103; [21] REPAIRED STRINGER 26L; BETWEEN STA 500D-520; WL 153 I.A.W SDR SWAA2021120340486Splice · corrodedCORROSION ON STRINGER SPLICE IN AFT CARGO BAY BS 796 RBL14 WL 153. REMOVED SPLICE BS 789 TO 799 RBL 14 WL 1.53 IAW SRM 51-40-02. REMOVED CORROSION ON STRINGER SPLICE, FOUND OUT OF LIMITS IAW SRM 53-00-03-1A-1, STEP 4A (1)(B). LOCATED AND DRILLED A NEW STRSDR SWAA2021120240482Stringer · crackedCRACKED STRINGER AT AREA AFT OF FCB BS540 S-25R RBL22 WL155. REPAIRED IAWSRM 53-00-03-2R-1 AND EA 21-153-03333.SDR SWAA2021122040181None · crackedSUPPLEMENTAL INFORMATION: TYPICAL CRACK EXTENDING FROM FASTENER HOLE OPPOSITE FITTING LATCH AT STA 294.5 BETWEEN S-8R AND S-9R. CRACK LENGTH 1.732' ; / REMOVED R-1 DOOR BODY TORQUE TUBE TO FACILITATE MAINTENANCE. REF B 737 AMM 52-41-41-000-801 STRIPPED PAINT ASDR SWIA202163305None · damagedRBL 9 INBD FLOORBEAM WEB BETWEEN FS 409+16 & FS 409+32 HAS A DAMAGED RADIUS ON THE FORWARD SIDE REQUIRING REPLACEMENT. (C CHECK RO 12/28/2021) PERFORMED A MAJOR REPAIR BY REMOVEING AND REPLACING RBL 9 INBD FLOORBEAM WEB BETWEEN FS 409+16 & FS 409+32 IAW CRSDR SWAA2021112940323Stringer · crackedCRACKED STRINGER 25R AND BS540 AT FWD CARGO COMPARTMENT. PERFORMED PERMANENT REPAIR ON STRINGER 25R BETWEEN BS 500C AND BS540 IAW SRM B737-700 SRM 53-00-03-2R-1; FIG 206.SDR SWAA2021112939897Stringer · crackedCRACK ON STRINGER 26R, BS540 AT FWD CARGO COMPARTMENT. PERFORMED PERMANENT REPAIR ON STRINGER 26R AND BTW BS 500D TO BS 540 IAW SRM 53-00-03-2R-1 REPAIR 1; FIG 206.SDR SWIA202163690None · corrodedPAX DOOR INTERCOSTAL CORRODED BETWEEN FS320.163 AND FS338.63 AT DD6. (C CHECK RO 01-05-2022) REMOVED AND REPLACED CLIP ATTACHED TO INTERCOSTAL DD6 IAW CRJ 700 SRM 51-42-06-001-001-A01SDR SWIA202163188None · corrodedPAX DOOR INNER STRUCTURE - INTERCOSTAL CORRODED - DATUM 6 - BETWEEN FS'S 311/320 - REF DWG 601R31702 REV N (C CHECK RO 12-19-21) REMOVED AND REPLACED INTERCOSTAL - DATUM 6 - BETWEEN FS'S 311/320 REF CRJ 700 SRM 51-42-06-001-001-A01, DWG 601R31702 REV N. PRSDR SWIA202162656None · corrodedCORROSION ON RH FLOOR BEAM INTERCOSTAL AS MARKED AT FR 90-91. (C-CHECK RO 11/16/2021) REMOVED AND REPLACED RH FLOOR BEAM INTERCOSTAL AS MARKED AT FR 90-91 REF SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRM 51-23-06SDR SWIA202163044None · crackedINTERCOSTAL PN.601R350121-1 IS CRAKED ON THE AFT SIDE OF THE FS.621 BULKHEAD, OTBD ON STGR.16L (C-CHECK RO 12/04/2021) REMOVED, LOCATED, DRILLED AND REPLACED INTERCOSTAL PN.601R350121-1 CRAKED ON THE AFT SIDE OF THE FS.621 BULKHEAD, OTBD ON STGR.16L IAWSDR SWAA2021122138643Bear Strap · crackedCRACK FOUND EMANATING FROM FASTENER OPPOSITE FITTING LATCH AT THE R1 DOOR BEAR STRAP BETWEEN BS 291.5 & 294.5, S8-9R. LENGTH OF CRACK 1.339'. PERFORMED CUT OUT AT BEARSTRAP IAW SRM 53-10-01-2R-6, REPAIR 6. STEP 4-C. FABRICATED REPAIR IAW SRM 53-10-01-2SDR REXA2021111601020Stringer · corrodedFOUND STR 27R CORRODED AT FS250-FS265. 2.0" X 1.0" X .021" DEEP. REPAIRED PER EA# CRJ953-12410SDR DALA2021110106740None · noneSHIP 6823 DURING EXECUTION NRC 264 REWORKED AREA IS OUT OF LIMITS AFTER CORROSION REMOVAL ON LBL 10.45 AT STA 662. CORRECTIVE ACTION: SUMMARY OF NRC 00711: SECTION FLOOR STRINGER LBL 10.45 BTW STA 635-705 WAS REPAIRED PER B757-200 SRM. (1999082)SDR DALA2021110106739None · noneSHIP 6823 DURING EXECUTION NRC 264 REWORKED AREA IS OUT OF LIMITS AFTER CORROSION REMOVAL ON RBL 16.10 AT STA 642. CORRECTIVE ACTION: SUMMARY OF NRC 00710: SECTION FLOOR STRINGER RBL 16.10 BTW STA 635-705 WAS REPAIRED PER B757-200 SRM. (1999046)SDR DALA2021110106738None · noneSHIP 6823 DURING EXECUTION NRC 256 REWORKED AREA IS OUT OF LIMITS AFTER CORROSION REMOVAL ON LBL 10.45 STA 820. CORRECTIVE ACTION: SUMMARY OF NRC 00707: SECTION STRINGER LBL 10.45 STA 810 - 840 WAS REPAIRED PER B757-200 SRM. (1999043)SDR DALA2021110106737None · noneSHIP 6823 ON REF NRC 0222 CORROSION ON INTERCOSTAL BTW STRINGER 29L TO 30 ON FLANGE AREA FROM STA= 1500 TO 1505 ALSO ON WEB AREA FROM STA= 1500 TO 1501 AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00694. INTERCOSTAL BTW STRINGER 29L TO 30 ON FLASDR AALA202111195612Stringer · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON STRINGER BETWEEN FR 64 AND FR 65 AT S42L. REPLACED STRINGER PER SRM 51-42-11.SDR SWAA2021112933840Stub Frame · crackedSUPPLEMENTAL INFORMATION: CRACK FWD SERVICE DOOR CUTOUT STUB FRAME LOCATED BS294.5 BETWEEN STR 7R AND STR 9R AT PASSENGER CABIN ; 2021-487807 / [01] REPLACED STUB FRAME LOCATED ON FWD SERVICE DOOR CUT OUT BS 294.5 BTW STR 7R AND STR 9R AT PASSENGER IAW B737-70SDR SWAA2021112933612Support Angle · crackedSUPPLEMENTAL INFORMATION: CRACK FWD SERVICE DOOR CUTOUT SUPPORT ANGLE LOCATED BETWEEN BS291.5 TO BS 294.5 AT STR 17R AT PASSENGER CABIN ; 2021-487792 / [01] FAULT RESOLVED ON OTHER FAULT; SEE TTG8Q0070KWP; FOR ANGLE REPLACEMENT; [02] FAULT RESOLVED ON OTHER FASDR SWAA2021112933611Frame · crackedSUPPLEMENTAL INFORMATION: CRACK FRAME ON BS 312 FWD UPPER CUT OUT ENTRY DOOR AT FWD GALLEY AREA ; 2021-487787 / [01] TOOL USED: TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811020 DUE DATE: 21-JAN-22; [02] PERFORMED REPAIR ON FRAME BS 312 FWD UPPER CUT OUTSDR SWAA2021112933605Tie Clip · crackedSUPPLEMENTAL INFORMATION: CRACK TIE CLIP LOCATED BS 277 AND STR10R AT PASSENGER CABIN ; 2021-487784 / [01] REPLACED TIE CLIP LOCATED BS 277 AND STR10R AT PASSENGER CABIN IAW B737-700 SRM 51-10-02; B737-700 SRM 51-40-40-02 AND DRAWING # 141A1110 SHEET 18 REV-.;SDR SWAA2021112933608Floorbeam · crackedCRACK FLOOR BEAM BS 294.5 AND RBL60 AT FWD GALLEY AREA ; 2021-487791 / [01] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600D; S/N: 210138503 DUE DATE: 05-MAR-22; [02] TOOL USED: EDDY CURRENT FLAW DETECTOR. PERFORMED REPAIR IAW SRM 53-10-51-2R-16 REPAIRSDR DALA2021102706654None · noneSHIP 3260 AFT UTILITY AREA FRAME 70 STRINGER 19 CORRODED. CORRECTIVE ACTION: R/R STRINGER CLIP FR70 STR 19R I.A.W. A320 SRM 51-72-11, 51-21-11, AND 51-44-00. (1996826)SDR SWIA202163346None · corrodedSERVICE DOOR CLIP CORRODED AT STGR 17. LOCATED AT CENTER LINE OF DOOR. (C CHECK RO 12/28/2021) REMOVED AND REPLACED CLIP ON SERVICE DOOR WITH NEW CLIP PN: 601R38304-317 AT DATUM 17 AND FS. 334 IAW CRJ 200 SRM 51-42-06 AND REF: DWG: 601R38304 REV: BN. SEE CSDR SWIA202163304None · corrodedSERVICE DOOR ANGLE CORRODED AT STGR 15 ABOVE HANDLE. (C CHECK RO 12/28/2021) REPAIRED SERVICE DOOR ANGLE CORROSION AT STGR 15 IAW CRJ 200 SRM 51-21-11, 51-24-16, 51-25-16, 51-40-11, 51-42-06, 51-42-21, AND 52-00-00. COMPLETED TASK CARD 51-900-1003-SKY AND SDR LR7A2021091102981None · noneDURING SCHEDULED C-4 CHECK WHILE PERFORMING OTHER MAINTENANCE, FOUND THE CHINE CAP CORRODED AT FS517, LBL53, WL146. / REPAIRED IAW LAC MEA 382-53-21-081. NR# 1000574569.SDR DALA2021102606638None · noneSHIP 6823 AFTER REMOVED FLOOR STRINGER, INTERCOSTAL ON STRINGER RBL 16.10 BTW STA 640 TO 660 WAS FOUND CRACKED, IN REF NRC 00710. CORRECTIVE ACTION: SUMMARY OF NRC 00715: INTERCOSTAL ON STRINGER RBL 16.10 BTW STA 640 TO 660 WAS REPAIRED PER B757-200 SRM. (1994SDR A6WA202112068005Skin · gougedDURING INSPECTION, MAINTENANCE FOUND 8 EACH AREAS OF DAMAGE TO THE FUSELAGE SKIN BETWEEN FS 255.00 AND FS 267.00 AND S25R - S27R. DIMENSIONS ARE: (P1) = 0.800"L X 0.700"W X 0.007"D (P2) = 0.650"L X 0.600"W X 0.008"D (P3) = 0.650"L X 0.600"W X 0.007"D (P4) = 0.SDR DALA2021102606611None · noneLOOSE FASTENER ON CLIP STA Y=1152 AND LONG 1L AT AFT ACCESSORY COMPARTMENT. SUMMARY OF NRC 00249: PERMANENT REPAIR WAS PERFORMED ON CLIP STA Y=1152 AND LONG 1L AT AFT ACCESSORY COMPARTMENT PER ETI-17-21- 017 REV. 2 AND ER/A 594962-14 REV. ORIGINAL, SECTION I. SDR SWIA202162824None · corrodedFOUND CORROSION AT LF LATCH-PIN INTERCOSTAL AT FS364 (C-CHECK RO 11-24-21) REMOVED AND INSTALLED NEW LF LATCHPIN INTERCOSTAL FROM FS349 TO FS364 REF CRJ-700 SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-001-A01 AND DWG SH670-32050 REV J. COMPLIED WITH TASDR DALA2021102606625None · noneSHIP 187 DURING INSPECTION MAINTENANCE FOUND A CRACK ON THE END FITTING OF THE FRAME WHICH IS ATTACHED TO THE CENTER WING UP SURFACE AT STA927, S22L. CORRECTIVE ACTION REPLACED THE FITTING ON THE CENTER WING UP SURFACE PER SRM. (LP 1992329)SDR SWAA2021112332533Stringer · corrodedCORROSION STRINGER 26L BTW BS 480/500A; LBL 19 APPROX; WL 150 AT FWD CARGO COMPARTMENT. REPAIRED STRINGER 26L BTW BS 480/500A; LBL 19 APPROX; WL 150 AT FWD CARGO COMPARTMENT B737-700 SRM 53-00-03-2R-1 REPAIR 1.SDR SWAA2021112332532Stringer · corrodedCORROSION STRINGER 27L LOCATED BTW BS500-500A, RBL 12.5, WL 149, FWD CARGO COMPARTMENT. PERFORMED PERMANENT REPAIR ON STRINGER IAW SRM 53-00-03-2R-1 REPAIR 1 TABLE 202 FIG. 206.SDR AALA202111105191Stringer · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON STRINGER BETWEEN FR 64 AND FR 67 AT S31R. REPLACED STRINGER PER SRM 51-42-11.SDR DALA2021102206577None · noneSHIP 187 FWD CARGO SHEAR TIE AT STA 390,S-39L TO S-39R FOUND CORROSION. CORRECTIVE ACTION: REPLACED AS PER B767-300 SRM51-40 (1990692)SDR DALA2021102206575None · noneSHIP 187 FWD CARGO SHEAR TIE AT STA 412,S-35L TO S-36L FOUND CORROSION. CORRECTIVE ACTION: REPLACED AS PER B767-300 SRM51-40(1990689)SDR YENA2021102100712Web · corrodedDURING HEAVY MAINTENANCE, FROM AEROMAN NR 2021-428652 CORROSION WEB LOCATED BTW FR 69 TO FR 70 STRG 23R AT AFT GALLEY AREA ( CPCP RELATED 534195-01) ; (RESOLVED ON W/O: 1121241 TASK CARD: NR-00015) FROM AEROMAN NR 2121-428652, WORK DONE BY H.MENDEZ 8601415, RISDR DALA2021102106551None · noneSHIP 187 CARGO SHEAR TIE AT STA 654+88,S-37L TO S-38L FOUND CORROSION. CORRECTIVE ACTION: REPLACED AS PER B767-300 SRM51-40 (1990685)SDR DALA2021102106550None · noneSHIP 187 FWD CARGO SHEAR TIE AT STA 654,S-34R TO S-35R FOUND CORROSION. CORRECTIVE ACTION: REPLACED AS PER B767-300 SRM51-40REPLACED AS PER B767-300 SRM51-40(1990683)
Back to JASC 5313