JASC 5313
Service difficulty reports · 36,310
Reports filed under 5313 · Fuselage Main, Longeron/Stringer, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5313' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5313' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2010F00149Stringer · corroded(COER) CORROSION FOUND ON STRINGER 20LT BETWEEN FR 24- FR 25 BEYOND SRM LIMITS. (LEVEL II) REMOVED CORROSION REF ATR72 SRM 51-21-58 REV 77 .010IN MATERIAL REMOVAL. ALLOWABLE IS .0027IN REF 51-10-10, SECTION IS OUT OF LIMITS. REPAIRED STRINGER IAW SRM.SDR 2010FA0000704Stringer · crackedDURING COMPLIANCE WITH AD 2005-01-18/ SB 53-2472 R4 INSPECTION OF THE AFT STRINGER CRACKED. RT AND LT SIDE STRINGERS NR 8, 9 AND 10 WERE CRACKED. ORDERED KITS 101-4064-1S, 101-4064-2S, 101-4064-3S, 101-4064-4S, 101-4064-5S, AND 101-4064-11S TO MODIFY STRINGESDR SWIA201024887Stringer · corrodedFORWARD END OF STRINGER 18 UNDER PAX DOOR CORRODED. (C-CHECK) REMOVED AND REPLACED FORWARD SECTION OF STRINGER 18 PER SRM.SDR K11A2010070672201Longeron · corrodedCORROSION ON O/B LOWER FLANGE OF OVERWING LONGERON (2 INCHES).SDR COER2010F00153Stringer · damagedBLENDED AREA ON STRINGER 20 IAW SRM 51-21-58, REV 77. MEASURED AFFECTED AREA MIN MATERIAL REMAINING .040" REF NTM 51-40-00, REV 34. FOUND OUT OF LIMITS IAW SRM 53-51-00, FIG 301, ORIG MAT .051 IAW SRM 53-51-26 IT 20 PERCENT MAT LOSS. CUT DAMAGED SECTION OUT SDR FDEA201007062378Longeron · corrodedCABIN - LONGERON 17 LT FROM STA 1441 TO STA 1461 CORRODED. REMOVED AND REPLACED AS PER SRM 51-31-01, VOLUME II. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100, REVISION 110.SDR FDEA201007062379Longeron · corrodedLONGERON 17 LT FROM STA 1501 TO STA 1521 CORRODED. DAMAGE REMOVED AS PER SRM 51-31-01 VOL 2 REV 96. NEW LONGERON FABRICATED AS PER QWG AEA 0220 P/N AEA0220-1 REV R. NEW LONGERON INSTALLED AS PER SRM 51-31-01 VOL 2 REV 96. REPAIR CLASSIFIED AS MAJOR AS PER GMMSDR FDEA201007062380Stringer · corrodedCORROSION - STRINGER 27L, STATION 740 INSIDE CHANNEL. CUT OUT STRINGER 27L AT BS 740, 8 5/8" LONG AND 2 STRINGER TIES ANGLES IAW SRM REV 103 53-10-3 FIG 1 51-30-2. FABRICATED STRINGER SECTION FROM BAC1498-147, 7075T6, 8 5/8" LONG SPLICE FROM BAC1498-131 707SDR FDEA201007062377Longeron · corrodedCABIN - LONGERON 17 LT FROM STA 1381 TO STA 1401 CORRODED. R & R IAW SRM 51-31-01 VOLUME II, REVISION 96. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 110.SDR FDEA201007062376Longeron · corrodedCABIN - LONGERON 17 LT FROM STA 1421 TO STA 1441 CORRODED. R & R IAW SRM 51-31-01 VOLUME II, REVISION 96. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 110.SDR FDEA201007062375Longeron · corrodedCABIN - LONGERON 17 LT FROM STA 1341 TO STA 1361 CORRODED. R & R IAW SRM 51-31-01 VOLUME II, REVISION 96. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 110.SDR FDEA201007062374Longeron · corrodedCABIN - LONGERON 19 LT FROM STA 1381 TO STA 1401 CORRODED. R & R IAW SRM 51-31-01 VOLUME II, REVISION 96. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 110.SDR SWAA103959Stringer · crackedDURING SCHEDULED 16Y CHECK, FOUND STRINGER CRACKED BETWEEN BS 500D TO BS 540, STR 11L. REMOVED AND REPLACED STRINGER PER EO.SDR SWAA103951Stringer Splice · corrodedDURING SCHEDULED 16Y CHECK, FOUND STRINGER SPLICE CORRODED BETWEEN BS 986.5 TO BS 1006, STR 24L. REMOVED AND REPLACED SPLICE PER SRM.SDR QXEA2010070600380Stringer · corrodedRFD - C CHECK - FOUND CORROSION ON STRINGER 20L BETWEEN FS485-FS501. REMOVED CORROSION FROM STR 20L AT FS485-FS501 IAW SRM 51-21-06-001-001-A01. 2 AREAS BLENDED 1ST BLEND MEASURES .5"X.5" AND .007" DEEP, 2ND BLEND WAS 1"X 1" AND .005" DEEP. ORIGINAL MATERIALSDR FDEA201007032343Stringer · corrodedCORROSION ON STRINGER 29L FROM BS 950F TO 970. REMOVED CORROSION ON STR 29L FROM 950F TO 970 IAW SRM 51-10-6. CW UT. THICKNESS IAW NDTM 51-00-00 PT 4 FIG 2, ORIGINAL AREA .140, REMAINING .111. EVALUATED AREA FOUND TO BE WITHIN LIMITS IAW EA 7-5330-135567. TRSDR FDEA201007022323Stringer · corrodedAFT CARGO COMPT BILGE AREA, STR 44 LT HAS CORROSION ON VERTCAL LEG FROM FR 62 TO FR 63,APPROX 10 SQ IN. REMOVED LEVEL 1 CORROSION. CUT OUT DAMAGED SECTION OF STR 44 LT AND INSTALLED STRINGER REPAIR AT STR 44 LT BETWEEN FR 62 AND FR 63 IAW SRM 53-10-14, FIG 2SDR EE4Y100239Stringer · corrodedLOWER FUSELAGE, AFT CARGO COMPARTMENT AT BS 865.5 STRINGER 27RT WITH CORROSION.SDR FDEA201007022317Stringer · crackedSTRINGER 9L AT STA 439 IS CRACKED. REMOVED STR 9L AL STA 439 AND STRINGER CLIP AT STA 418 ON S-9L FOR ACCESS IAW: SRM 51-40-02. ROUTED AND RECEIVED FROM FAB SHOP, REPAIR STRINGER TRAV NR T10/843350. LOCATED AND DRILLED REPAIR STRINGER 9L AT STA 439 AND STSDR DHLA201000077Longeron · crackedLONGERON 24R CRACKED 1.5" STA FS 900.000. PERFORMED MAJOR REPAIR IAW SRM 53-2-2 FIG 5, SHEET 1, 13, 14, 15, 16, 25, 26, 27 TR 53-123 DATED 05-15-01. REMOVED FASTENERS IAW SRM 51-1-20D. PERFORMED STOP HOLE AND FABRICATED 2 REPAIR ANGLES, & 2 SHIMS IAW SRM 53-SDR EE4Y100237Stringer · corrodedLOWER FUSELAGE AFT SECTION AT BS 977 STR 20LT WITH CORROSION.SDR EE4Y100236Stringer · corrodedLOWER FUSELAGE E&E COMPARTMENT FROM BS 344 TO BS 360 STR 25LT WITH CORROSION.SDR AALA20100630TUL08Longeron · crackedLONGERON 2 LEFT CRACKED AFT OF STATION 1418. INSTALLED LONGERON SPLICE REPAIR AT STATION 1418 LONGERON 2 LEFT PER AARD 53-30-00-2.SDR AALA20100630TUL04Longeron Splice · corrodedAFT CARGO, CORROSION IN LONGERON 30 SPLICE AT STATIONS 1293 TO 1299. REPLACED SPLICE PER SRM 51-30-05 AND EA MD80-51-011436.SDR FDEA201006302281Longeron · damagedMAIN DECK CARGO STATION 535 LONGERON 25L STRINGER FOUND DAMAGED. DAMAGED LONGERON AT MAIN DECK CARGO STATION 535 LONGERON 25L REMOVED AND REPLACED WITH NEW FABRICATED LONGERON AS PER DWG ACA3017 REV L AND INSTALLED AS PER SRM 51-31-01 REV 43. REPAIR CLASSIFIESDR GLBA20100630HStringer · crackedMAJOR REPAIR - DURING A SCHEDULED ROUNTINE INSPECTION A CRACK WAS FOUND AT FS 451 ON THE STRINGER 10R ON THE HORIZONTAL PORTION OF THAT STRINGER, .45" IN LENGTH. MAINTENANCE REPAIRED THE AFFECTED AREA AND PERFORMED ALL REQUIRED RII INSPECTIONS IAW EO 10-1900-5SDR FDEA201006302292Stringer · corrodedAFT CARGO COMPARTMENT BILGE AREA STR. 45L HAS CORROSION AT FR60 TO FR60 2 INCHES APPROX TOTAL 2 SQ INCHES. REMOVED CORROSION IAW SRM 51-74-10, CHECKED FOUND OUT OF LIMITS IAW SRM 53-10-00 PAGE 106. REPAIRED STR 45LT BETWEEN FR 60 AND FR 61 IAW A310 SRM 53-1SDR ABXA201006300095Stringer · corrodedSTRINGER 34L STA 434-466 REMOVED DUE TO CORROSION. REPLACED STRINGER WITH P/N BAC1498-207 IAW B767 SRM 51-40-02. REPAIRED IAW B767 SRM 53-00-03 FIG 201 REPAIR 2.SDR ABXA201006300094Stringer · corrodedSTRINGER 33L STA 434-466 REMOVED DUE TO CORROSION. REPLACED STRINGER SECTION WITH P/N BAC1497-207 IAW B767 SRM 51-40-02. REPAIRED IAW B767 SRM 53-00-03 REPAIR 2 FIG 201.SDR ABXA201006300093Stringer · corrodedSTRINGER 32 L STA 434-466 REMOVED DUE TO CORROSION. REPLACED STRINGER SECTION WITH P/N BAC 1498-207. REPAIRED IAW B767 SRM 53-00-03. REPAIR NR 2 FIG 201 AND B767 SRM 51-40-02.SDR WGFY2010FA0000496Stringer · corrodedSTRINGER 43 LT WAS CORROSION STA 960-1000 AT BELOW FWD CARGO AREA. REPAIR CLASSIFICATION FOR SRM REPAIR: CAT 'B', REPETITIVE INSP SRM 53-10-03 FIG 1, SHEET 6, TABLE IV. SRM 51-10-06, 51-21-00, 53-10-03 FIG 1, 51-10-02. REPAIR REPETITIVE INSPECTION REQUIREMESDR UIEA2010062900075Stringer · damagedNRC 1125, FWD CGO STRINGER 36R IS BENT BETWEEN STA 500-520 (DAMAGED PORTION OF STRINGER REMOVED, REINFORCED AREA WITH NEW SEGMENT AND REPAIR STRINGER PN N523MC, NRC 1125 1/2 IAW SRM 53-10-03 FIG 3 AND FASTENERS INSTL IAW SRM 51-30-02)SDR UIEA2010062800074Stringer · bentNRC: 1120 "FWD CGO" STRINGER 38L IS BENT BETWEEN STA 480 TO 500 (DAMAGED AREA TRIMMED OUT REINFORCED AREA WITH NEW SEGMENT AND REPAIR STRINGER AND FILLER PN N52MC, NRC 1120 1,2,3 IAW SRM 53-10-03, FIG 3. FASTENERS INSTALLED IAW SRM 51-30-02).SDR UIEA2010062800072Stringer · bentNRC: 0979 "LOWER DECK" B/T STA 360-380 S 35R STRINGER LOWER FLANGE IS BENT. (DAMAGED AREA TRIMMED OUT, REINFORCED AREA WITH STRINGER REPAIR AND FILLER P/N N523MC NRC 979 1/2 PER SRM 53-10-03 FIG 3. FASTENERS INSTL PER SRM 51-30-02)SDR UIEA2010062800069Stringer · damagedNRC: 0972 "LOWER DECK" STA 320, STR 28.7, R. DOUBLE HOLE ON THE STRINGER. (DAMAGED AREA TRIMMED OUT. REINFORCED AREA WITH NEW SEGMENT AND REPAIR STRINGER PN N523MC, NRC 972 1/2 IAW SRM 53-10-03, FIG 3 & AMP; FASTENERS INSTL IAW SRM 51-30-02.)SDR UIEA2010062800068Stringer · damagedNRC 0971: "LOWER DECK" JUST FWD OF STA 320 STR 37R ELONGAGED FASTENER HOLE ON STRINGER (DAMAGED AREA TRIMMED OUT. REINFORCED AREA WITH NEW SEGMENT AND REPAIR STRINGER PN N523MC NRC 971 1/2 IAW SRM 53-01-03, FIG 3, FASTENERS INSTL IAW SRM 51-30-02).SDR SWAA103832Stringer · corrodedDURING SCHEDULED 16Y CHECK, FOUND STRINGER CORRODED AT BS 967, STR 25L. REPAIRED STRINGER PER SRM.SDR FDEA201006282213Stringer · corrodedFWS CARGO BILGE AREA AT FR 899 AND STR 52. STRINGER HAS EXFOLIATION CORROSION. REMOVED SPLICE IAW SRM 51-21-01. REMOVED COROOSION IAW SRM 51-21-10. FABRICATED PARTS LONGERON REPAIR AND SPLICE REPAIR ON TRAVELER T10/838926 AND T10/838928. LOCATED AND DRILLESDR UIEA2010062700062Stringer · bentNRC 0973 LOWER DECK STA 380-400, STR 39R, STRINGER UPPER FLANGE IS BENT. (DAMAGED PORTION OF TRIMMED OUT REINFORCED AREA WITH NEW SEGMENT AND REPAIR STRINGER PN 523 NRC 1/2 IAW SRTM 53-10-03 FIG 3. FASTENERS INSL IAW SRM 51-30-02).SDR UIEA2010062700067Stringer · twistedNRC: 1397, STA 440, STR 41-L FOUND TWIST STR AND NBSP; TURN TO AT LOWER DECK (P-6 AREA)(DAMAGED AREA TRIMMED OUT. REINFORCED AREA WITH NEW ZEE PN N523MC NRC 1397-1 IAW SRM 53-10-03 FIG 3, FASTENER INSTL IAW SRM 51-30-02).SDR UIEA2010062700063Stringer · bentNRC0974, LOWER DECK STA 380, 400 STR 37R STRINGER UPPER FLANGE IS BENT (DAMAGED PORTION OF STRINGER REMOVED. REINFORCED AREA WITH NEW SEGMENT AND REPAIR STRINGER REMOVED. REINFORCED AREA WITH NEW SEGMENT AND REPAIR STRINGER PN N523MC NRC 971 -/2 IAW SRM 53-1SDR SWAA103818Stringer Splice · crackedDURING SCHEDULED 14Y CHECK, FOUND STRINGER SPLICE CRACKED AT BS 907, STR 4R. REMOVED AND REPLACED SPLICE PER SRM AND BAC DWG.SDR SWAA103817Stringer Splice · crackedDURING SCHEDULED 14Y CHECK, FOUND STRINGER SPLICE CRACKED AT BS 907, STR 4L. REMOVED AND REPLACED SPLICE PER SRM AND BAC DWG.SDR SWAA103800Stringer Splice · crackedDURING SCHEDULED 16Y CHECK, FOUND STRINGER SPLICE CHANNEL CRACKED AT BS 360, STR 16L. REMOVED AND REPLACED CHANNEL PER SRM AND BAC DWG.SDR FDEA201006262201Stringer · corrodedAFT PIT BS 1183 STR 18L IS CORRODED CUTOUT DAMAGED STRINGER SECTION APPROX DIM: 7 1/4", FABRICATED NEW STRINGER SECTION FROM BAC 1498-144 APPROX DIM: 7 1/4", FABRICATED STRINGER REPAIR SPLICE FROM BAC 1498-132 APPROX DIM: 14 1/2" & INSTALLED REPAIR PARTS AT BSSDR AALA20100625TUL04Longeron · corrodedCORROSION ON LONGERON 30 STATIONS 1285 TO 1293. REMOVED CORRODED LONGERON INSTALLED NEW LONGERON AND SPLICE PER SRM 53-02-00.SDR DALA1014623267Longeron · corrodedDURING M-CHECK FOUND CORROSION ON LONGERON 31R AT FR66. REPAIRED IAW SRM 51-42-11, PAGE 211.SDR IPXA10661010Stringer · crackedINSPECTION TYPE:C, M/DECK STA 1552 TO 1556 S20R CRACKED. STA 1542.3 TO STA 1579.3, S20R REPAIRED IAW RS R53-61-36765 AND EO B767-5310-38675. ORG MATL IS BAC1506-3122-7075T62, CRACK LENGTH IS 4" APPROX, CUT OFF LENGTH IS 37" THIS REPAIR IS CLASSIFIED AS A MASDR UIEA2010062400073Stringer · crackedNRC 1115 "LOWER DECK" CRACK ON STR 35L UPPER FLANGE AT STA 420 (DAMAGED AREA TRIMMED OUT, REINFORCED AREA WITH NEW SEGMENT AND REPAIR STRINGER PN N523MC, NRC 1115 1/2 IAW SRM 53-10-03 FIG 3 FASTENER INSTL IAW SRM 51-30-02)SDR UIEA2010062400070Stringer · bentNRC: 0975 "LOWER DECK" B/T STA 380 - 400 STR 40R STRINGER UPPER FLANGE IS BENT. (DAMAGED AREA TRIMMED OUT, REINFORCED AREA WITH NEW SEGMENT AND REPAIR - STRINGER PN N523MC, NRC 0975 1/2 IAW SRM 53-10-03, FIG 3. FASTENERS INSTL IAW SRM 51-30-02).
Back to JASC 5313