JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021031750532Crease Beam · corrodedAFT CABIN WET AREA STA 960-982; BL54R; WL208; CREASE BEAM INNER CHORD ANGEL UPPER SURFACE; CORROSION; MRK'D. / CORROSION FOUND TO BE OUT OF LIMITS PER SRM 53-70-15-1A-1 ORIG T: .080 LOSS: .012 REMAINING: .068 REMOVED AND REPLACED R2 CREASE BEAM FROM STA 887+5 SDR FDEA202102220419Floorbeam · corrodedMAIN CABIN BS 1200 FLOOR BEAM HAS AREAS OF CORROSION ON UPPER SURFACE BETWEEN BL0 AND LBL 24. REMOVED CORROSION AT MAIN CABIN BS 1200 FLOOR BEAM ON UPPER SURFACE BETWEEN BL0 AND LBL 24 IAW B 757 SRM 51-10-02-OG.EVALUATED AREAS ORIG MAT .125" LOWEST READISDR FDEA202102220421Floorbeam · corrodedMAIN CABIN FLOOR PANEL SUPPORT ANGLE UPPER SURFACE HAS AREAS OF CORROSION AT BB BB BS 1020 BETWEEN BL0 AND LBL 24. ACCOMPLISH WITH FEDEX E.A.#:F-5310-T0359922 P1. TITLE: FUSELAGE - MAINFRAME - MAIN CARGO FLOOR SUPPORT STA 1020 CORRODED,NEW PART FABRICATISDR FDEA202102220420Floorbeam · corrodedMAIN CABIN FLOOR PANEL SUPPORT ANGLE UPPER SURFACE HAS AREAS OF CORROSION AT BS 1055 BETWEEN BL0 AND LBL 24. ACCOMPLISH WITH FEDEX E.A.#:F-5310-T0359923 P1. TITLE: FUSELAGE - MAINFRAME - MAIN CARGO FLOOR SUPPORT STA 1055 CORRODED,NEW PART FABRICATION - TEMSDR SWIA202157487Floorbeam · crackedFOUND FLOOR SUPPORT ANGLE TO BE CRACKED AT F.S 621 BETWEEN LBL27 AND LBL 36. (C-CHECK RO 4/12/2021) REPAIRED DAMAGE BY REMOVING AND INSTALLING NEW REPAIR ANGLE IAW CRJ 200 SRM 51-42-06 AND 51-42-21. COMPLETED TASK CARD 51-900-1003-SKY AND ATTACHED COMPSDR SWIA202156989Strap · corroded*CORROSION ON FLOOR SUPPORT STRAP BETWEEN RBL27 €“ RBL45 AT FS 559.00 (C-CHECK) RO 3/24/2021 FLOOR SUPPORT STRAP BETWEEN RBL27 €“ RBL45 AT FS559.00 HAS CORROSION ACROSS ENTIRE LENGTH. REPLACEMENT IS NECESSARY WHEN MORE THAN 30% OF ITS LENGTH IS DAMAGED.SDR SWIA202157475Floorbeam · crackedFS 484 INTERCOSTAL BETWEEN LBL27 AND LBL36 IS CRACKED ON THE OUTBARD SIDE. (C-CHECK RO 4/12/2021) REPAIRED F.S.484 INTERCOSTAL BETWEEN LBL 27 AND LBL36 IAW CRJ 200 MHIRJ REO 601R-53-41-2872 REV. --, DATED 2021-03-09. / MAJOR REPAIR FORM M-337 IS COMPLESDR SWIA202157184Floorbeam · corrodedF.S 280 FLOOR BEAM CORRODED AT LBL11-RBL11 (C-CHECK RO 4/1/2021) REMOVED AND REPLACED FS280.00 FLOOR BEAM AT FLOOR LEVEL RBL11 & LBL11. REF CRJ700 CRJ700 SRM 51-42-06-001-001-A01 AND REF CRJ700 SRM 51-42-10-001-001-A01, CRJ700 SRM 51-42-21-001-001-A01, CRSDR FDEA202102160452Floorbeam · corrodedCENTER CARGO COMPT CEILING STA 1761 LBL 18 MAIN DECT FLOORBOARD SUPPORT CORRODED AT NUT CLIPS. MRKDSDR FDEA202102160450Floorbeam · corrodedCENTER CARGO COMPT CEILING STA 1661 RBL 65 MAIN DECK FLOORBOARD SUPPORT CORRODED. MRKD REMOVED AND REPLACED FLOOR SUPPORT, P/N: AFA 3853-21 AT STA 1661 @ RBL 62 TO RBL 68 IN REF TO DWG # AFA 3853.SDR SWAA2021031851347Beam · corrodedCORROSION FLOOR STRUCTURE BEAM LOCATED BS 986.5 AT LEVEL WL 208.1 RBL 43 AT AFT GALLEY AREA / REPAIRED PAX CABIN FLOOR STRUCTURE TRANSVERSAL BEAM AT BS 986.5 AND RBL 43 AND WL 208.1 IAW EA # 21-153-00607 REV IR EA # 53-0086-21 REV 0 AND PART 1SDR FDEA202102160605Floorbeam · corrodedCENTER CARGO COMPT CEILING STA 1561 RBL 60 MAIN DECK FLOORBOARD SUPPORT BRACKET CORRODED AT NUT CLIP. FABRICATED AND INSTALLED FLOOR BOARD SUPPORT P/N AFA3853-33 AT STA 1561 RBL 60 REF SRM 51-35-01 VOL 2 AND DWG AFA3583SDR FDEA202102160474Floorbeam · corrodedCENTER CARGO COMPT CEILING STA 1561 RBL 10 MAIN DECK FLOORBOARD SUPPORT CORRODED AT NUT CLIP. MRKD MAIN CARGO AT STA 1561 RBL 10 REMOVED AND REPLACED FLOOR SUPPORT AFA3853 REF MD10-30 SRM 51-31-01 VOL 2.SDR FDEA202102160462Floorbeam · corrodedCENTER CARGO COMPT CEILING STA 1821 RBL 10-20 MAIN DECK FLOORBOARD SUPPORT HAS CORROSION AT 3 NUTCLIPS. MRKD REMOVED AND REPLACED FLOOR BOARD SUPPORT CENTER CARGO COMPT CEILING STA 1821 RBL 10-20 MAIN DECK. REF. SRM 51-31-01, VOL II.SDR DALA2021030101123Floorbeam · corrodedDURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR BEAM STA 377 BTW LBL 10 TO LBL 24 AND LBL 51 TO LBL 54 AT PAX CABIN FLOOR STRUCTURE. REPAIRED PER ERA 481634-14. (LP 1732084)SDR FDEA202102160453Floorbeam · corrodedCENTER CARGO COMPT CEILING STA 1741 LBL 35 MAIN DECK FLOORBOARD SUPPORT CORRODED AT NUT CLIPS. MRKD REMOVED CORRODED SUPPORT & INSTALLED NEW FABRICATED FLOOR SUPPORT AT STA. 1741 LBL 35 PER SRM 51-35-01 VOL II AND DWG AFA3853SDR FDEA202102160463Floorbeam · corrodedCENTER CARGO COMPT CEILING STA 1761 RBL 10-20 MAIN DECK FLOORBOARD SUPPORT CORRODED AT NUT CLIPS. MRKD REMOVED AND REPLACED FLOOR SUPPORT AT STA. 1761 RBL 10-20 PER SRM 51-35-01 VOL II AND DWG ACA3140SDR SIMA20210216009Angle · crackedRIGHT FLOOR SUPPORT ANGLE AT FR 59 IS CRACKED ON OUTBD EDGE. -C/A- INSTALLED NEW FLOOR SUPPORT IAW SRM 51-40-02.SDR DALA2021021700893Floorbeam · bentSHIP 3240 BENT INTERNAL STRUCTURE CROSS BEAM LOCATED AT FR 29 BTW STR 38L TO STR 38R IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: REPLACED CROSS BEAM PER A320 SRM 51-42-11 AND A320 SRM 51-72-11. (1732178)SDR ABXA2021215021Floorbeam · corrodedDURING C-CHECK, CORROSION ON FWD CARGO STA 654 FLOOR BEAM UPPER CAP BOTTOM SIDE ARPOUND NUT PLATES LBL 10. REMOVED CORROSION AT FWD CARGO STA 654 FLOOR BEAM UPPER CAP IAW B767-300 SRM 51-10-02. EVALUATED DAMAGE, ORIGINAL MATERIAL THICKNESS IS .102, MAT LOSS ISDR MASA20210316093Floorbeam · corrodedCORROSION ON FLOOR BEAM [ UPPER/AFT FLANGE] IN STA. FS= 280 AND 11LBL TO 14LBL AT PAX CABIN FWD WET AREA. (W1) (CPAX)|LF FLOOR BEAM WAS REPLACED PER CRJ900 SRM 51-42-06-001-001-A01 AND SRM 51-42-20-001-001-A01SDR YENA2021021900123Floorbeam · corrodedDURING HMV, CORROSION FLOOR BEAM +Y599.9 FR 68 AT AFT GALLEY AREA ; REMOVED AND REPLACED FLOOR BEAM +Y599.9 AT FR 68 IN AFT GALLY ARE IAW A320 SRM 51-72-11. WORK ACCOMPLISHED ON AEROMAN NR 2021-060833SDR YENA2021021900122Floorbeam · corrodedDURING HMV, CORROSION FLOOR BEAM +Y765 BTW FR68 AT AFT GALLEY AREA ; REMOVED AND REPLACED FLOOR BEAM +Y765 AT FR 67 IAW A320 SRM 51-72-11. WORK ACCOMPLISHED ON AEROMAN NR 2021-060832SDR YENA2021021900107Floorbeam · corrodedDURING HMV, EC E21-042-01 FUSELAGE / CENTER FUSELAGE III / FLOOR STRUCTURE BEAMS AT FR85 AND Y-273 & Y+273 / CORROSION - PERMANENT REPAIR /// THIS IS CONSIDERED A MAJOR REPAIR.SDR SWIA202157171Floorbeam · corrodedFS280 CAP ANGLE IS CORRODED AND BENT AT FLOOR LEVEL, RBL9 (C-CHECK RO 4/1/2021) REMOVED AND REPLACED THE FS280 CAP AT FLOOR LEVEL RBL9. REF CRJ700 SRM 51-42-06-001-001-A01 AND REF CRJ700 SRM 51-42-13-001-001-A01. COMPLIED WITH TASK CARD 51-900-1002-SKY.SDR SWIA202157169Floorbeam · corrodedFS280 CAP ANGLE IS CORRODED AND BENT AT FLOOR LEVEL, LBL9 (C-CHECK RO 4/1/2021) REMOVED AND REPLACED FS280 CAP ANGLE AT FLOOR LEVEL LBL9. REF DWG CC670-34010 REV K, CRJ700 SRM 51-42-06-001-001-A01 AND REF CRJ700 SRM 51-42-13-001-001-A01 . COMPLIED WITH TASDR MASA20210308070Floorbeam · corrodedCORROSION ON FLOOR BEAM [UPPER/AFT FLANGE] IN STA FS=280 AND 11RBL TO 13RBL AT PAX FWD WET AREA|FLOOR BEAM WAS REPLACED FRO A NEW ONE PER CRJ900 SRM 51-92-06-001-001-A01 AND SRM 51-42-71-001-001-A01SDR DALA2021021900963Floorbeam · crackedSHIP 3240 CRACKS WERE FOUND IN HOLE NR 2 AND HOLE NR 3 OF CROSSBEAM JUNCTION FR 16 LHS. CORRECTIVE ACTION: INSPECT CRACKS AND CONT ON MON. OK FOR CONTINUED SERVICE. (1730391)SDR SWIA202157213Floorbeam · corroded*AVIONICS BAY FORWARD FLOORBOARD SUPPORT ON THE AFT SIDE OF THE FS280.00 FRAME IS CORRODED AT MULTIPLE AREAS ON BOTH THE TOP AND LOWER SURFACE. (MARKED) (C-CHECK RO 4/1/2021) REMOVED AND REPLACED MAIN AVIONICS BAY FORWARD FLOORBOARD SUPPORT ON THE AFT SIDSDR SWIA202157204Floorbeam · cracked*FS 280 BEAM / RBL 12 ANGLE BRACKET HAS EVIDENCE OF CRACK AT TOP OF RADIUS. (C-CHECK RO 4/1/2021) REMOVED AND REPLACED BRACKET, FS280, RBL12, REF CRJ 700 SRM 51-42-21-001-001-A01SDR SWIA202157152Floorbeam · corrodedFS 280 FLOOR SUPPORT ANGLE FOR COCKPIT FLOORBOARD 221ALF HAS EVIDENCE OF CORROSION. (C-CHECK RO 4/1/2021) REMOVED & REPLACED FS 280 FLOOR SUPPORT ANGLE FOR COCKPIT FLOORBOARD 221ALF REF CRJ-700 SRM51-42-06-001-001-A01 AND DWG# CC670-33052 REV G. COMPLIED SDR MASA20210308069Floorbeam · crackedCRACK ON LONGITUDINAL FLOOR BEAM 12RBL IN STA. FS=279 AT COCKPIT |FLOOR BEAM 12RBL WAS REPAIRED PER CRJ900 SRM-53-11-43-201-003-A01SDR MASA20210308068Floorbeam · crackedCRACK ON LONGITUDINAL FLOOR BEAM 12LBL IN STA. FS-279 AT COCKPIT|FLOOR BEAM WAS REPAIRED PER CRJ900 SRM 53-11-43-201-003-A01SDR CALA2021021500172Floorbeam · corrodedCABIN STA 303 LBL 36 TO 53 FLOOR BEAM FOUND CORROSION REFER NR LP 9130939 CABIN STA 303 LBL 36 TO 53 FLOOR BEAM UPPER CHORD PERMANENT REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 201 AND ECRA 5315-01153 REV.SDR SWIA202157063Floorbeam · corrodedA-BAY FS280 FLOOR SUPPORT ANGLE IS CORRODED (C-CHECK) RO 3/25/2021 REMOVED AND INSTALLED NEW FLOOR SUPPORT ANGLE P/N#CC670-34256-1 ASSY. IN A-BAY FS280.00 REF. CRJ-700 SRM 51-42-06-001-001-A01, CRJ-700 SRM 51-42-21-001-001-A01 AND DWG # CC670-34010 REV K SDR DALA2021021100797Floorbeam · corrodedDURING INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON FLOOR BEAM AT STA 1640 BTW RBL 51 TO RBL 60. FLOOR BEAM REPAIRED PER SRM. (LP 1727639)SDR SWIA202157519Floorbeam · crackedF.S. 280 LBL 9 INBOARD AND OUTBOARD SUPPORT CLIPS ARE CRACKED. (C-CHECK RO 4/12/2021) REMOVED AND REPLACED I/B AND O/B SUPPORT CLIPS AT FS280 LBL 9 IAW CRJ 200 SRM 51-42-06 & 51-42-21 OPS TEST GOODSDR SWIA202157518Floorbeam · crackedINTERCOSTAL CLIP CRACKED AT F.S. 484.00 BETWEEN LBL27 AND LBL36 (C-CHECK RO 4/12/2021) REMOVED AND REPLACED INTERCOSTAL CLIP AT F.S. 484.00 LBL 27 IAW CRJ 200 SRM 51-40-11, 51-42-06, AND 51-42-21. INTERCOSTAL CLIP AT F.S. 484.00 LBL 36 REFERENCE JOB: 97SDR SWIA202157506Floorbeam · crackedF.S. 280 RBL 9 SUPORT CLIP IS CRACKED. (C-CHECK RO 4/12/2021) REPAIRED FS280 RBL9 IAW REO 601R-53-21-3407 REV. --, DATED 03/02/2021. FORM 337 AND MAJOR REPAIR TASK CARD 51-900-1003-SKY COMPLETED AND ATTACHED. NO WEIGHT CHANGE. SEE CONTINUATION CARD FOSDR SWIA202157505Floorbeam · corrodedFLOOR BEAM AT LBL9 HAS MULTIPLE SPOTS OF CORROSION FROM F.S. 409.00 TO F.S. 409.00+128 (C-CHECK RO 4/12/2021). REMOVED AND REPLACED FLOOR BEAM AT LBL9 FROM FS 409.00-409+128 IAW BOMBARDIER REO 601R-53-31-1187 REV -- DATED 2021-03-08. FORM 337 AND MAJOR REPAIRSDR SWIA202157504Floorbeam · corrodedFLOOR BEAM AT RBL9 HAS MULTIPLE SPOTS OF CORROSION FROM F.S. 409.00 TO F.S. 409.00+128 (C-CHECK RO 4/12/2021) REMOVED AND REPLACED FLOOR BEAM AT RBL 9 BETWEEN FS 409-409+128 IAW CRJ 200 SRM 51-42-36, 51-42-21, BOMBARDIER REO 601R-53-00-005 REV.B, DATED SDR SWIA202157476Floorbeam · corrodedFLOOR BEAM AT RBL 9 HAS MULTIPLE SPOTS OF CORROSION FROM F.S. 409.00+128 TO F.S. 559.00 (C-CHECK RO 4/12/2021) REMOVED AND REPLACED FLOOR BEAM AT RBL 9 F.S. 409.00+128 TO F.S. 559.00 IAW REO 601R-53-41-2870 REV-- DATED 2021-02-18. FORM 337 AND MAJOR RESDR SWIA202157474Floorbeam · corrodedFLOOR BEAM AT LBL9 HAS MULTIPLE SPOTS OF CORROSION FROM F.S. 409.00+128 TO F.S. 559.00 (C-CHECK RO 4/12/2021) REMOVED AND REPLACED FLOOR BEAM AT LBL9 FROM F.S. 409.00+128 TO F.S. 559.00 AS REQUIRED IAW REO 601R-53-41-2871 REV-- DATED 2/12/2021. FORM 3SDR SWIA202157473Floorbeam · damagedINTERCOSTAL AT F.S. 484.00 BETWEEN RBL27 AND RBL36 HAS 2 EA BROKEN CLIPS. (C-CHECK RO 4/12/2021) REMOVED AND REPLACED CLIPS IAW CRJ 200 SRMS 51-42-21, 51-42-06, 51-40-11, 51-24-36. REFER TO CONTINUE CARD FOR WORK PERFORMED. FORM 337 AND MAJOR REPAIR TASDR A6WA202102177648Floorbeam · corrodedCORROSION COMMON TO PRESSURE FLOOR ANGLE AT FUSELAGE STATION 439.00 RBL 41 TO RBL 42. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FS 439 RBL 41 TO RBL 42. .5 INCH WIDE X 1.2 INCH LONG PERFORMED HFEC, NO DEFECTS NOTED. PERFORMED UT THICKNESS CHECK, SDR A6WA202102177649Floorbeam · corrodedCORROSION COMMON TO PRESSURE FLOOR ANGLE AT FUSELAGE STATION 461.00 RBL 40 TO RBL 42. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FS 461 RBL 40 TO RBL 42. .8 INCH WIDE X 2.2 INCH LONG PERFORMED HFEC, NO DEFECTS NOTED. PERFORMED UT THICKNESS CHECK, SDR A6WA202102177644Floorbeam · corrodedCORROSION COMMON TO PRESSURE FLOOR ANGLE AT FUSELAGE STATION 513.00+5 RBL 36 TO RBL 42. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FS 513.00+5 RBL 36 TO RBL 42. SPOT P1, .5 INCH WIDE X 1.0 INCH LONG. P2, .8 WIDE X 1.6 INCH LONG. P3, 1.8 WIDE X SDR A6WA202102177645Floorbeam · corrodedCORROSION COMMON TO PESSURE FLOOR ANGLE AT FUSELAGE STATION 499.00+4 RBL 40 TO RBL 42. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FS 499.00+4 RBL 40 TO RBL 42. 1.0 INCH WIDE X 2.5 INCH LONG PERFORMED HFEC, NO DEFECTS NOTED. PERFORMED UT THICKNESS SDR A6WA202102177642Floorbeam · corrodedLIGHT CORROSION COMMON TO PRESSURE FLOOR ANGLE AT FUSELAGE STATION 409.00 +128+3, RBL 43. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FS409.00+128+3RBL 43. 0.3 INCH WIDE X 0.8 INCH LONG, PERFORMED HFEC NO DEFECTS NOTED. PERFORMED UT THICKNESS CHECSDR A6WA202102177643Floorbeam · corrodedCORROSION COMMON TO PRESSURE FLOOR ANGLE AT FUSELAGE STATION 449.85+2 RBL 40 TO RBL 42. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FS 449.85+2 RBL 40 TO RBL 42. P1, .5 INCH WIDE X 1.1 INCH LONG. P2, 1.0 INCH WIDE X 3.0 INCH LONG. PERFORMED HFEC,
Back to JASC 5315