JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR A6WA202102177638Floorbeam · corrodedCORROSION COMMON TO PRESSURE FLOOR ANGLE AT FUSELAGE STATION 559.00 LBL 40 . TO LBL 42. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION AT FS 559.00 LBL 40 TO LBL 42, 1.1 INCH WIDE X 1.2 INCH LONG PERFORMED HFEC NO DEFECTS NOTED, PERFORMED UT THICHNESS SDR A6WA202102177639Floorbeam · corrodedCORROSION COMMON TO PRESSURE FLOOR ANGLE AT FUSELAGE STATION 499.00 + 7 TO FUSELAGE STATION 513.00 RBL 36 TO RBL43. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION AT FS 499 + 7 TO FS 513, RBL 36 TO RBL 43. SPOT P1, 1.0 INCH WIDE X 3.5 INCH LONG, FS 499SDR A6WA202102177646Floorbeam · corrodedCORROSION COMMON TO PRESSURE FLOOR ANGLE AT FUSELAGE STATION 484.00 RBL 40 TO RBL 42. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FS 484.00 RBL 40 TO RBL 42. 1.4 INCH WIDE X 1.4 INCH LONG PERFORMED HFEC, NO DEFECTS NOTED. PERFORMED UT THICKNESS CHSDR A6WA202102177637Floorbeam · corrodedCORROSION COMMON TO PRESSURE FLOOR ANGLE AT FS 409.00 + 128 + 12 RBL 36 TO RBL 42 ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION AT FS409.00+128+12 RBL 36 TO RBL 42, SPOT P1 .7 INCH WIDE X .9 INCH LONG, P2 .6 INCH WIDE X 2.3 INCH LONG. PREFORMED HFECSDR A6WA202102177647Floorbeam · corrodedCORROSION COMMON TO PRESSURE FLOOR ANGLE AT FUSELAGE STATION 424.00+4 RBL 36 TO RBL 42. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FS 424.00+4 RBL 36 TO RBL 42. 1.0 INCH WIDE X 2.1 INCH LONG PERFORMED HFEC, NO DEFECTS NOTED. PERFORMED UT THICKNESSSDR A6WA202102167635Channel · corrodedCORROSION COMMON TO FLOOR STRUCTURE AT FUSELAGE STATION 559.00 RBL 38 TO RBL 41. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED AND INSTALLED NEW FABRICATED FLOOR STRUCTURE AT FUSELAGE STATION 559.00RBL 38 TO RBL 41 REF CRJ200 SRM 53-41-43 REV 38.SDR A6WA202102167652Floorbeam · corrodedCORROSION COMMON TO PRESSURE FLOOR ANGLE AT FUSELAGE STATION 513.00+11 LBL 40. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION PRESSURE FLOOR ANGLE AT FS 513.00+11 LBL 40. EVALUATED BLEND AREA FOUND TO BE WITHIN ALLOWABLE LIMITS. HFEC INSPECTION PERFORSDR A6WA202102167654Floorbeam · corrodedCORROSION COMMON TO PRESSURE FLOOR ANGLE AT FUSELAGE STATION 473.15+5 LBL 36 TO LBL 42. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED CORROSION FROM PRESSURE FLOOR ANGLE AT FS 473.15+5 LBL 36 TO LBL TO LBL 42. EVALUATED BLEND AREA FOUND TO BE WITHIN ALLOWABLESDR DALA2021021000785Floorbeam · corrodedSHIP 3303 CORROSION FLOOR BEAM YA LOCATED AT LEVEL FR.73 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM YA AND FASTENERS LOCATED AT LEVEL FR.73 AT AFT GALLEY AREA AS PER A330 SRM. (1726956)SDR SWIA202157501Floorbeam · corrodedFLOOR BEAM AT LBL9 HAS MULTIPLE SPOTS OF CORROSION FROM F.S. 559.00 TO F.S. 559.00+80 (C-CHECK RO 4/12/2021) REPAIRED FLOOR BEAM AT LBL9 FROM FS 559 TO 559+80 IAW CRJ200 SRM 53-00-43 & 51-42-06, BOTH REV. 38B DATED 25 NOV 2020. FORM M-337 AND MAJOR REPSDR SWIA202157500Floorbeam · corrodedFLOOR BEAM AT RBL 9 HAS MULTIPLE SPOTS OF CORROSION FROM F.S. 559.00 TO F.S. 559.00+80 (C-CHECK RO 4/12/2021) REMOVED AND REPLACED FLOORBEAM IAW CRJ200 SRM 51-42-21, 51-42-36 (BOTH REV. 38B, DATED 11/25/20) AND REO 601R-53-51-565 REV. --, DATED 03/09/20SDR SWIA202157499Floorbeam · corrodedFLOOR BEAM AT LBL9 HAS MULTIPLE SPOTS OF CORROSION BETWEEN F.S. 574.00 AND F.S. 621.00 (C-CHECK RO 4/12/2021) REMOVED AND REPLACED FLOOR BEAM AT LBL 9 BETWEEN FS 574.00 TO FS 609.00 IAW CRJ 200 SRM 51-42-06, 51-42-21, 51-42-15 AND 51-42-36. FORM 337 ANSDR SWAA2021031550668Floorbeam · damaged/ REMOVED AND REPAIRED DAMAGED FLOOR BEAM RBL58 TO LB 58 ALL WORK ACCOMPLISHED PER SRM 53-70-51-2R-5 AND EA 21-153-00314 PARTS 1 AND 2.SDR SWIA202156892Floorbeam · corroded* FS 559+80 RBL 9 TO RBL 27 TOP CAP HAS CORROSION (C-CHECK) RO 3/10/2021 REMOVED AND INSTALLED NEW CAP PN 601R32215-43. REF. CRJ200 SRM 51-42-06 AND DWG 601R32215 REV. M. COMPLIED WITH 51-900-1003-SKY.SDR SWAA2021030847322Floorbeam · corroded***CORROSION*** AT AFT PASSENGER CABIN ON FLOOR BEAM BS986 RBL43 WL208. / REMOVED AND REPLACED FLOOR BEAM AT BS986 FROM LBL9 TO RBL43 WL208 RIGHT HAND SIDE IAW SRM 53-70-51-2R-4 REPAIR 4; SRM 53-70-51-1A-1; SRM 51-40-02; AMM 20-60-07; DWG# 147A5730 REV A; DWG#SDR SWAA2021030847331Floorbeam · crackedCRACKED FLOOR BEAM AT FWD CABIN BS328 RBL20 WL208. / REPAIRED CRACKED FLOOR BEAM AT FWD CABIN BS328 RBL20 WL208 IAW SRM 53-10-51-2A-7; NO FURTHER ACTION.SDR SWAA2021051347141Floorbeam · corrodedCORROSION FOUND ON FLOOR BEAM 947.5 RBL 25 AFT LAV FLOOR MOUNTS / REPAIR TO BE ACCOMPLISHED AND REMOVED STRUCTURE TANSFERRED TO NR D472553.SA-M 326 A1304066SDR SWAA2021051347142Floorbeam · corrodedCORROSION FOUND ON FLOOR BEAM 947.5 LBL 25 AT AFT LAV MOUNTS / REPAIR TO BE ACCOMPLISHED AND REMOVED STRUCTURE TRANSFERRED TO NR D472553.SDR SWAA2021030948153Floorbeam · corrodedCORROSION FLOOR BEAM LOCATED BS 986.5 AND LBL 42 WL 208 AT PASSENGER CABIN / PERFORMED PERMANENT REPAIR ON FLOOR BEAM LOC BS986.5 AND LBL 42 WL 208 AT PASSENGER CABIN IAW SWA EA#21-153-00451 REV IR AND AEROMAN EA #53-0064-21 REV 0 AND PART 1 MATERIAL USED BAC SDR SWIA202156543Floorbeam · corrodedAFTER REMOVING COCKPIT FLOOR AFT SUPPORT FOUND RH FS280 CROSSBEAM TO HAVE CORROSION (C-CHECK) RO 3/2/2021 REMOVED AND REPLACED RH FS 280.00 NEW CROSSBEAM P/N CC670-34094-2S REF CRJ700 SRM 51-42-06-001-001-A01, SRM 51-42-22-001-001-A01, AND DWG CC670-3401SDR SWIA202156542Floorbeam · corrodedAFTER REMOVING COCKPIT FLOOR AFT SUPPORT FOUND LH FS280 CROSSBEAM TO HAVE CORROSIONREMOVED AND REPLACED LH FS 280.00 NEW CROSSBEAM P/N CC670-34094-1S REF CRJ700 SRM 51-42-06-001-001-A01, SRM 51-42-22-001-001-A01, AND DWG CC670-34010 REV -K , COMPLIED WITH TASSDR R61A2021021900173Floorbeam · corrodedCFIII FLOOR STRUCTURE, CORROSION FOUND AT CROSSBEAM UPPER FLANGE AT FR 84. REPAIRED CARRIED OUT IAW EMB SRM 53-00-10 & ETD2021-170-003621.SDR SWAA2021030846972Floorbeam · corroded***CORROSION*** ON RAIL AROUND FASTENER HOLE BS727B+3 LBL3 WL156. / PERFORM CUT-OUT FROM BS727+7' TO BS 727B+10' LBL3 WL156 I.A.W SRM 53-00-53-2R-2 STEP 2.F. LOCATED; DRILLED AND COUNTERSANK NEW REPAIRABLE BEAM AND CHANNEL SPLICE I.A.W SRM 53-00-53-2R-2; SRM 5SDR SWAA2021022246921Floorbeam · crackedCRACKED FLOOR SUPPORT AT B.S. 540; B.L. 0 TO L.B.L. 24; W.L. 208.1. / REMOVED AND INSTALLED NEW FLOOR SUPPORT AT B.S. 540; B.L. 0 TO LBL 24. WL. 208.1 ITEM # 7530908 IAW SRM 51-40-02-0G-0; DWG # 143A0060 57319U 02-05-21SDR DALA2021020400666Beam · corrodedSHIP 3236 CORROSION FLOOR STRUCTURE BEAM LOCATED BTW FR 12 TO FR 24 AND -Y765 IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-42-11.SDR SWIA2021080960127Angle · weakCOMPLY WITH REO 601R-53-41-1116 REPAIR & REINFORCEMENT FOR FS 559.00 LWR CAP ANGLES BL 9.00 & 18.00 LHS & RHS (C-CHECK RO 8/5/2021) COMPLIED WITH REO 601R-53-41-1116 REPAIR & REINFORCEMENT FOR FS 559.00 LWR CAP ANGLES BL 9.00 & 18.00 LHS & RHS, REFERENCSDR DALA2021020200628Floorbeam · corrodedSHIP 3303 CORROSION FLOOR BEAM -Y1137.1 LOC. AT LEVEL FR 74 AT AFT GALLEY AREA. CORRECTIVE ACTION: PERFORMED REPAIR INSTRUCTION FLOOR STRUCTURE/INTERCOSTAL AS PER A330 ER/A. (1720740)SDR DALA2021020200625Floorbeam · corrodedSHIP 3303 CORROSION FLOOR BEAM +Y1137.1 LOC AT LEVEL FR 74 AFT GALLEY AREA. CORRECTIVE ACTION: PERFORMED REPAIR INSTRUCTION FLOOR STRUCTURE BEAM AS PER ER/A. (1720744)SDR R61A2021022800206Panel Support · corrodedAFT WET AREA CORROSION ON RH SILL PANEL BETWEEN FR84-85 AND Y=+38. REMOVED AND REPLACED RH SILL PANEL IAW SRM 51-40-08 & 51-41-02.SDR R61A2021022800205Panel Support · corrodedAFT WET AREA CORROSION ON RH PANEL SUPPORT AT FR87 AND Y=+27. REMOVED AND REPLACED PANEL SUPPORT IAW SRM 51-41-01.SDR R61A2021022800203Shear Panel · corrodedAFT WET AREA CORROSION ON RH SHEAR PANEL BETWEEN FR87-FR88 AND Y=+23. REMOVED AND REPLACED RH SHEAR PANEL IAW SRM 51-41-01 & 51-43-01.SDR R61A2021022800201Panel Support · corrodedAFT WET AREA CORROSION ON RH SILL PANEL AT FR89 AND Y=+33. REMOVED AND REPLACED RH SILL PANEL IAW SRM 51-40-08.SDR R61A2021022800200Gusset · corrodedAFT WET AREA CORROSION ON RH GUSSET PLATE UPPER FLOOR AT FR90 AND Y=+22. REMOVED AND REPLACED RH GUSSET PLATE UPPER FLOORL IAW SRM 51-40-08 & 51-41-02.SDR R61A2021022800199Panel Support · corrodedAFT WET AREA CORROSION ON LH SILL PANEL AT FR90 AND Y=-32. REMOVED AND REPLACED LH SILL PANEL IAW SRM 51-40-08 & 51-41-02.SDR R61A2021022800198Shear Panel · corrodedAFT WET AREA CORROSION ON LH SHEAR PANEL BETWEEN FR87-FR88 AND Y=-13. REMOVED AND REPLACED LH SHEAR PANEL IAW SRM 51-40-08.SDR R61A2021022800197Support · corrodedAFT WET AREA CORROSION ON LH PANEL SUPPORT AT FR86 AND Y=-28. REMOVED AND REPLACED PANEL SUPPORT IAW SRM 51-41-01.SDR R61A2021022800196Upper Sheet · corrodedAFT WET AREA CORROSION ON LH UPPER SHEET BETWEEN FR85-FR86 AND Y=-12. REMOVED AND REPLACED LH UPPER SHEET IAW SRM 51-41-01 & 51-43-01.SDR R61A2021022800195Support · corrodedAFT WET AREA CORROSION ON LH MOUNTING SUPPORT AT FR84 AND Y=-37. REMOVED AND REPLACED PANEL SUPPORT IAW SRM 51-41-01 & 51-41-02.SDR SWAA2021030146012Floorbeam · corrodedFWD CARGO STA 520; RBC AND LBC 25 FLOOR SUPPORT HAS CORROSION / REMOVED + REPLACED LOWER L ANGLE AT STA 500I RBL 25 TO LBL 25 PER SRM 51-40-02 + SRM 53-00-53-1A-1. PART NO. 143A9485-37SDR R61A2021022800207Seat Track · corrodedCORROSION ON FWD WET AREA FLOOR STRUCTURE LH SEAT TRACK UPPER SURFACE FROM FR19-15 SEVERAL SPOTS. REMOVED AND REPLACED LH SEAT TRACK IAW SRM 51-40-08.SDR SWIA202157286Floorbeam · crackedCOCKPIT FLOOR BEAM TO VERTICAL POST ATTACH ANGLE AT FS 280.00 LBL 12 IS CRACKED. MARKED WITH TAPE. (C-CHECK RO 4/2/2021) REMOVED AND REPLACED ANGLE IAW CRJ200 SRM 51-42-06 AND 51-42-10. SEE CONTINUATION CARD FOR DETAILS OF WORK PERFORMED.SDR REXA2021022300072Angle · corroded280 J ANGLE CORRODED ALONG ENTIRE TOP SURFACE BETWEEN LBL 9 AND RBL9. REMOVED & REPLACED 280 J ANGLE IAW CRJ 900 SRM 51-40-11-001-001-A01, 51-42-10-001-001-A01, 51-42-21-001-001-A01, & 51-42-06-001-001-A01. WVAC EMP STAMP NR 796 MTC.SDR V0XD20210302003Floorbeam · corrodedFWD FLOOR BOARD SUPPORT AT F.S. 280 HAS SIGNS OF CORROSION. CORRECTIVE ACTION: REMOVED AND REPLACED FLOOR BOARD FWD SUPPORT AT F.S. 280 IAW CRJ900 SRM 51-42-06.SDR SWIA202156382Floorbeam · corrodedFLOOR BEAM AFT OF F.S 559+80 AT LBL 9.0 HAS CORROSION AT NUTPLATE MARKED WITH RED TAPE (C-CHECK) RO 2/21/2021 PERFORMED REPAIR TO F.S 559. +87€? AT LBL 9.0€? FLOOR BEAM SUPPORT FLANGE IAW REO 601R-53-00-827 REV: -- DATE 2021-01-30 AND REF: CRJ 200 SRM 5SDR SWIA202156381Floorbeam · corrodedFLOOR BEAMS AFT OF FS 559+80 ON LBL 9 AND RBL 9 HAVE CORROSION AT NUTPLATE LOCATIONS MARKED WITH RED TAPE. (C-CHECK) RO 2/21/2021. PERFORMED REPAIR TO FS 559. + 87€? AT RBL 9 FLOOR BEAM SUPPORT FLANGE IAW REO 601R-53-00-827 REV: -- DATE 2021-01-30 AND REF: SDR DALA2021020200622Floorbeam · crackedSHIP 3239 WINGS / CENTER WING / FRONT SPAR AT FR36 / FLOOR BEAM & VERTICAL STIFFENER / CRACKS. CORRECTIVE ACTION: ACCOMPLISH ER/A 589108-14. CONT ON MON. (1718034)SDR DALA2021020100582Floorbeam · corrodedSHIP 3239 CORROSION FLOOR BEAM -Y254 AT LEVEL FR12 AT FWD GALLEY AREA. CORRECTIVE ACTION REPLACED FLOOR BEAM PER A320 SRM 51-72-11.SDR SWAA2021030145796Floorbeam · crackedCRACKED FLOOR SUPPORT AT B.S. 540; B.L. 0 TO L.B.L. 24.5; W.L. 208.1. / REMOVED AND REPLACED FLOOR SUPPORT AT B.S.540 B.L.0. LBL24.5 W.L.208.1 IAW SRM 51-40-02-0G-0 & SRM 51-40-05 & DWG 143A5240SDR FDEA202101280216Floorbeam · crackedCENTER CARGO COMPARTMENT - FLOORBEAM AT STATION 1741, BETWEEN X=-6.5 AND X= 6.5 FOUND CRACK. REPAIR CARRIED OUT ON CRACK FLOOR BEAM AT CENTER CARGO COMPARTMENT STATION 1741, BETWEEN X=-6.5 AND X= 6.5 AS PER EA NUMBER 1-5321-T0359449 PART 1 TITLE: FUSELAGSDR DALA2021012800544Floorbeam · corrodedCORROSION FLOOR BEAM +Y450 LOCATED AT LEVEL FR 80 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM AND FASTENERS +Y450 LOCATED BETWEEN FRAME 75 AND FRAME 80, AS PER SRM A330 51-72-11-911-001.
Back to JASC 5315