JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2019123107651Floorbeam · corrodedCORRODED FLOORBEAM -Y1162, FRAME 68 IN THE AFT GALLEY AREA. REPLACED THE FLOORBEAM IAW SRM 51-42-11, 51-72-11, AND DWG D53472780. MEASURES OF CORROSION L=3.252", W=1.230", D=0.025".SDR DALA2019123007598Floorbeam · corrodedCORROSION FLOORBEAM +Y1162 AT FRAME 68 IN THE AFT GALLEY AREA. REPLACED THE FLOORBEAM IAW SRM 51-72-11, AND DWG D534727801.SDR SWAA2022041235366Floorbeam · corrodedCORROSION ON FLOOR BEAM UPPER T CAP LOWER SURFACE AT 4 EA FLOOR BOARD SCREW HOLES AT STA 947.5 WL 208 LBL 11 TO RBL 11 / REMOVED CORROSION ON LOWER SURFACE OF FLOOR BEAM UPPER T CAP AT STA 947.5; LBL 11 TO RBL 11 ORIGINAL .180' LOSS OF .037' REMAINING .143' FOSDR SWIA2020020348134Floorbeam · crackedFOUND SUSPECTED CRACK AT FS280 FLOOR BEAM WEB AT RBL9 (C-CHECK) RO 1/29/2020 VERIFIED CRACK AT FS280 FLOOR BEAM WEB VIA NDT. PERFORMED REPAIR TO FS280.00 BULKEAD AND FABRICATED NEW PARTS REFERENCE BOMBARDIER REO.SDR SWAA2020010840248Floorbeam · corrodedFLOOR BEAM UPPER T CAP LOWER SURFACE CORRODED AT BS. 947.5, BETWEEN LBL 11 TO RBL 11. / REPAIRED FLOOR BEAM IAW EA 192600.SDR SWAA2020010240106Floorbeam · crackedFLOOR SUPPORT CRACKED AT BS. 540, BETWEEN RBL 3 TO RBL 23. / R&R FLOOR SUPPORT IAW SRM AND DWG.SDR SWAA2020010240105Floorbeam · crackedFLOOR SUPPORT CRACKED AT BS. 540, BETWEEN LBL 3 TO LBL 23. / R&R FLOOR SUPPORT IAW SRM AND DWG.SDR DALA2019122657543Floorbeam · corrodedFLOOR BEAM AT BS 287, LBL 86 ADJACENT TO L1 DOOR TEE SUPPORT FOUND CORROSION . THE FLOORBEAM WAS REPAIRED IAW PRI583491-14 REV 0 .SDR DALA2019122657541Floorbeam · corrodedFLOORBEAM AT BS 303, LBL 86 ADJACENT TO THE L1 DOOR TEE SUPPORT WAS FOUND CORRODED. THE FLOOR BEAM WAS REPAIRED IAW PRI 583492-14 REV 0. THE PRI 583492-14 REV 0 COMPAIRED AND COMPLETED WITH THE ER/A 583492 -14REV ORIGINAL .SDR SWIA2020013148017Floorbeam · crackedFS280 FLOORBEAM CLIP RBL9 INBOARD IS CRACKED (C-CHECK) RO 1/28/2020 REMOVED AND REPLACED FS280 FLOORBEAM CLIP RBL9 INBOARD REF. CRJ 200 SRM AND REO. C/W TASK CARD.SDR SWIA2020013148016Floorbeam · crackedFS280 FLOORBEAM CLIP RBL9 OUTBOARD IS CRACKED (C-CHECK) RO 1/28/2020 REMOVED AND REPLACED FS280 FLOORBEAM CLIP RBL9 OUTBOARD REF. CRJ 200 SRM AND REO. C/W TASK CARD.SDR SWIA2020013148015Floorbeam · crackedFS280 FLOORBEAM CLIP LBL9 INBOARD IS CRACKED (C-CHECK) RO 1/28/2020 REMOVED AND REPLACED FS280 FLOORBEAM CLIP LBL9 INBOARD REF. CRJ 200 SRM AND REO. C/W TASK CARD. NOTE: REO PREVIOUSLY COMPLIED WITH, AND USED FOR FABRICATION AND INSTALLATION ONLY.SDR AALA2020011439057Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN WET AREA FLOORBEAM AT BS 947 AND LBL 26. REPAIRED FLOORBEAM PER SRM 53-00-53-2R-5.SDR NACA2020010800170Floorbeam · crackedBS660 - BS666, FLOOR BEAM LOWER CHORD, LBL24.82 CRACK INDICATION IN FORWARD HOLE. RBL24.82 CRACK INDICATIONS IN FORWARD AND AFT HOLES. UPSIZE TO REMOVE CRACK IAW SB737-57A1296SDR SWIA2020013148004Floorbeam · corrodedCORROSION ON FLOOR BEAM SUPPORT ANGLE FS349.00 LH SIDE AT WINDSCREEN TIEDOWN POST, MARKED (C-CHECK) RO 1/28/2020 CORROSION ON FLOOR BEAM SUPPORT ANGLE 100% EXFOILIATED, FABRICATED NEW ANGLE AND INSTALLED IT REF DRAWING, AND COMPLIED WITH SKYCARD STRUCTURALSDR SWIA2020013148002Floorbeam · corrodedFS280.00 BEAM HAS CORROSION AROUND SCREW HOLES, COCKPIT ENTRYWAY, MARKED (C-CHECK) RO 1/28/2020 REMOVED AND REPLACED AFT COCKPIT FLOOR SUPPORT AT FS280 REF. CRJ 200 SRM, BOMBARDIER DWG, AND REO. COMPLIED WITH TASK CARD.SDR SWIA2020013148001Floorbeam · corrodedCOCKPIT ENTRYWAY AFT FLOOR SILL ANGLE CORROSION, MARKED, FS280.00 (C-CHECK) RO 1/28/2020 REPAIRED CORRODED COCKPIT ENTRYWAY AFT FLOOR SILL ANGLE FS280.00 REF. REO, ALL STEPS COMPLIED WITH.SDR SWIA2020011447665Floorbeam · corrodedCORROSION AFT WET AREA ON THE FLOOR SUPPORT R/H SIDE LOCATED ON THE FR87 CROSSBEAM (C-CHECK) RO 1/11/2020 REMOVED AND REPLACED FLOOR SUPPORT ON THE RH SIDE LOCATED ON THE FR 97 CROSSBEAM. REF SRM.SDR SWIA2020011447663Floorbeam · corrodedFLOOR BEAM AT + Y= 273.0 CORRODED AT FR 16. (C-CHECK) RO 1/11/2020 REMOVED AND REPLACED CORRODED FLOOR BEAM AT + Y= 273.0 AT FR 12-20 REF SRM. SEE CONTINUATION CARD FOR DETATAILS.SDR CALA2020010600009Floorbeam · corroded[B737-53-3-0737] AFT WET AREA STA 986.5 FLOOR BEAM HAS CORROSION ON UPPER FORWARD FLANGE LBL 43. [MKD 78-35] REF AAR NR 99861630 ACCOMPLISHED PERMANENT REPAIR AT FLOOR BEAM STA 986.5 FROM LBL 50 TO RBL 50 (FULL LENGTH OF BEAM) PER B737-800 SRM 53-70-51 REPASDR SWIA2020012147946Floorbeam · crackedINBOARD CLIP AT RBL9 FS 280 PART# 601R31113-58 IS CRACKED. (C-CHECK) RO:1/17/2020REMOVED, REPLACED AND INSTALLED NEW CLIP P/N 601R31113-58 AT FS 280 RBL 9 REF BOMBARDIER REO.SDR FDEA201912203270Floorbeam · corrodedAFT CARGO FR60 Y140 - Y805, FLOORBEAM WITH HEAVY CORROSION. REPAIRED THE AFT CARGO FR60 Y140 - Y805 CORRODED FLOORBEAM PER SRM 51-40-21 & SRM 53-10-15-201 PARA 9. THE REPAIR CATEGORY "A", MAJOR REPAIR IAW GMM 6-2-100.SDR SWAA2022032554632Beam · crackedON EA# 1-753-36215 (PART 1) HOLE # 5 HAS VISUAL AND HFEC VERIFIED CRACK PER NDT PART 6 51-00-00 PROCEDURE 16. / REPAIRED PER EA 1-753-36215.SDR REXA2020010719031Floorbeam · damaged"HIDDEN DAMAGE: ELONGATED HOLES ON STRIP UPPER SPLICE CROSSBEAM FS280 IN REF NRC 00178 (SM)[CPIL].
"SUMMARY OF NRC 00354: STRIP UPPER SPLICE CROSSBEAM FS280 WAS REPLACE PER CRJ/900 SRM 51-42-06-001-001-A01 AND 51-42-SDR ASAA2019122491648Floorbeam · corrodedMAIN CABIN, TOP BEAM CORRODED AT FRAME 66 AT APPROX -Y1500. GROUNDED - YES. REMOVED CORROSION OF DAMAGED AREA BY ENLOGATION FASTNER HOLE TO MAX SIZE, AND DAMAGE WAS STILL PRESENT AREA FOUND TO BE OUT OF LIMITS IAW A319 SRM 51-41-14, FABRICATED (MACHINED) REPASDR AALA2019122319019Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN WET AREA FLOOR BEAM UPPER "T" CAP AT BS 947 AND LBL 25. REPAIRED FLOOR BEAM PER SRM 53-70-51-2R-5.SDR DALA2019122007444Floorbeam · corroded(AIRCRAFT 6717, L/P 1409642) CORROSION ON FLOOR BEAM STA 1640 BTW LBL 15/RBL 5,AT AFT GALLEY FLOOR STRUCTURE. CORRECTIVE ACTION: REPAIRED PER B757-200 SRM 53-00-51-2R REPAIR 10 AND ER/A 521546-14 REV. ORG.SDR AALA202001139045Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN WET AREA FLOOR BEAM BETWEEN FR 75 AND FR 76 AT YA. REPLACED FLOOR BEAM PER SRM 51-72-11.SDR AALA202001139044Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN WET AREA FLOOR BEAM BETWEEN FR 73 AND FR 74 AT YB. REPLACED FLOOR BEAM PER SRM 51-72-11.SDR SWAA2020010940314Floorbeam · corrodedR2 DOOR FLOOR BEAM STRUCTURE CORRODED AT BS. 986.5. / INSTALLED UPPER CHORD FLOOR BEAM PER SRM.SDR SWAA2020010840255Floorbeam · crackedFORWARD WET AREA FLOOR BEAM UPPER CHORD CRACKED AT BS. 294.5, BETWEEN RBL 25 TO RBL 56. / REPAIRED FLOOR BEAM PER SRM.SDR R61A202001040013Floorbeam · corrodedAFT LAV WET AREA HAS CORROSION ON L/H FLOOR BEAM AT FR87 AS MARKED. BLENDED EFFECT AREA AND FOUND OUT OF LIMITS, FABRICATED REPAIR DOUBLER ON BEAM PN: 170-65669-003 REF MB SRM 53-23-10 AND INSTALLED REF EMB SRM 53-23-10, RESTORE SURFACE REF EMB SRM 51-23-06SDR SWIA202002248768Floorbeam · crackedFS280.00 RBL9 ANGLE CRACKED, UNDERFLOOR AT COCKPIT ENTRY. (C-CHECK) RO 2/20/2020 REMOVED CRACKED ANGLE AND REPLACED WITH NEW ANGLE CLIP IAW CRJ 200 SRM AND SRM.SDR SWIA2020020348207Stringer · corroded*INTERIOR STRINGER JOINT FOUND CORRODED AT FS559.+112 FROM STGR27LH THROUGH STGR26LH. CIRCLED WITH GREASE PENCIL (C-CHECK) RO:1/29/2020EVALUATION OF REINFORCEMENT ANGLE LOCATED AT FS559+112 STRINGER 27 ON LH SIDE. OUT OF LIMITS MORE THAN 30% OF THE LSDR AALA2020011009018Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN WET AREA FLOOR BEAM AT FR 66 AND +Y1732. REPAIRED FLOOR BEAM PER SRM 53-41-14-300-001 REPAIR PRINCIPLE 6.SDR SWAA2020010940324Floorbeam · corrodedFLOOR BEAM CORRODED AT BS. 986, BETWEEN RBL 28 TO RBL 43. / REPAIRED FLOOR BEAM IAW SRM.SDR REXA2020010702030Floorbeam · damaged"HIDDEN DAMAGE: ELONGATED HOLES ON RIGHT ANGLE CAP CROSSBEAM FS280 IN REF NRC 00299 (SM)[CPIL].
"RIGHT ANGLE CAP CROSSBEAM FS280 WAS REPLACE PER CRJ/900 SRM 51-42-13-001-001-A01 SDR REXA20200107029Floorbeam · elongated"HIDDEN DAMAGE: ELONGATED HOLES ON LEFT ANGLE CAP CROSSBEAM FS280 IN REF NRC 00178 (SM)[CPIL].
"SUMMARY: ON NRC. 00352, LEFTT ANGLE CAP CROSSBEAM FS280; WAS REPLACEDPER CRJ/900 SRM 51-42-13-001-001-A01 SDR MASA20200409001Floorbeam · corrodedL/H FLOOR BEAM CORRODED BETWEEN 85/86. REPAIRED L/H FLOOR BEAM IAW EMBRAER ETD1019-170-161-702SDR SWIA2020020348171Floorbeam · corrodedFS280.00 BEAM AREAS OF CORROSION, (COCKPIT ENTRYWAY) MARKED (C-CHECK) RO:1/29/2020REMOVED CORROSION FROM FS280.00 BEAM AREA (COCKPIT ENTRYWAY) REF CRJ 200 SRM. ORIGINAL MATERIAL THICKNESS IS .040, REF CRJ200 SRM. THE REMAINING THICKNESS IS .034 MATERSDR REXA2020010716023Floorbeam · corroded"INITIAL INSPECTION: CORROSION ON CROSSBEAM FS280.00 AT RBL12 (SM)[CPIL].
""SUMMARY: ON NRC. 00299 CORROSION LEVEL 2. CROSSBEAM FS280.00 AT RBL12 WAS REPLACED PER CRJ-900 SRM 51-42-06-001-00SDR SWAA2019122639923Floorbeam · corrodedAFT CARGO COMPARTMENT FLOOR BOARD SUPPORT CORRODED AT BS. 771, RBL 7. / REPAIRED BEAM IAW SRM.SDR SWAA2019122639922Floorbeam · corrodedAFT CARGO COMPARTMENT FLOOR BOARD SUPPORT CORRODED AT BS. 771, BETWEEN RBL 3 TO RBL 7. / REPAIRED BEAM IAW SRM.SDR REXA2019122641765Floorbeam · corrodedCORROSION FOUND ON FLOORBEAM ANGLE AT BS 280 BETWEEN LBL 11TO RBL 11. FLOORBEAM ANGLE WAS REPLACED IAW SRM 51-42-06-001-001-A01, AND SRM 51-42-20-001-001-A01.SDR A6WA2019121847063Floorbeam · crackedL/H FLOOR SUPPORT SILL PLATE CRACKED AT FS 605.0 ADJACENT TO FASTENER COMMON TO SILL AND FLOOR SUPPORT BEAM AIRCRAFT REMOVED FROM SERVICE REPAIRED L/H FLOOR SILL PLATE AT FS 605.0 IAW REO 601R-53-61-433SDR SWIA2019020348040Floorbeam · damagedPERFORM LOCAL REPAIR TO RBL 9 FLOORBEAM CAP AT FS 559+4 IAW S/N SPECIFIC REO. (C-CHECK) RO 1/28/2020 REPAIRED FLOOR BEAM CAP AT FS 559+4 IAW BOMBA REO. P/N-KFN587-3 TAG#A84011 P/N-HST11AG6-4 TAG#A80240 P/N-KFN587-3 TAG#A83571 P/N-HST11AG5-6 TAG#B99244 SDR R61A201912211420Floorbeam · cracked***WHILE A/C WAS OUT OF SERVICE FOR A HEAVY CHECK*** AT FR12 & LBL39 COCKPIT FLOOR STRUCTURE ANGLE FOUND CRACKED. REMOVED AND REPLACED ANGLE IAW SRM 51-41-01. A/C REMAINS OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR R61A201912211419Angle · cracked***WHILE A/C WAS OUT OF SERVICE FOR HEAVY CHECK COMPLETION*** AT FR12 & BL0 COCKPIT FLOOR STRUCTURE ANGLE FOUND CRACKED. REMOVED AND REPLACED ANGLE IAW SRM 51-41-01. A/C REMAINS OUT OF SERVICE FOR HEAVY CHECK COMPLETION.SDR DALA2019121647340Floorbeam · corroded(LOG 1401758) DURING INSPECTION FOUND CORROSION ON FLOOR BEAM PREVIOUS REPAIR FROM STATION 986 BTW LBL 54 TO RBL 54. FLOOR BEAM FROM STATION 986 BTW LBL 54 TO RBL 54 WAS REPAIRED PER ETI-37-19-356 REV 2 AND ERA 583800-14.SDR SWIA202002248804Strap · corrodedCORROSION FOUND ON FLOOR SUPPORT STRAP AT F.S 559 LBL 27-47 (C-CHECK) RO 2/20/2020 REMOVED AND REPLACED OLD STRAP WITH NEW STRAP AT FS559 LBL 27-47 IAW STS EA.