SDR SWAA2022031649731Track · corrodedAFT CARGO COMPARTMENT FLOOR SUPPORT STA 727B+1 LBL18 HEAVY CORROSION AT FASTENER HOLE / REMOVED AND REPLACED AFT CARGO FLOOR TRACK FROM STA 727 TO 867 LBL 17 PN # 146A7501-1 PER SRM 51-10-02.SDR SWAA2022031649733Track · corrodedAFT CARGO COMPARTMENT FLOOR SUPPORT STA 727B+9-727B+16 RBL13 HEAVY CORROSION AT FASTENER HOLES / REMOVED AND REPLACED AFT CARGO COMPARTMENT FLOOR TRACK FROM STA. 727+5 TO 887 RBL13 ; P/N 146A7501-25 PER SRM. 51-10-02SDR SWIA2019100446409Floorbeam · crackedL/H FS280 CENTER FLOOR BEAM OUTBD CLIP CRACKED (C-CHCEK) RO: 10/01/2019 REMOVED CRACKED FS280 LBL9 OTBD CLIP ANGLE AND INSTALLED NEW, FABRICATED, CLIP ANGLE IAW REO.SDR SWAA2019092537186Floorbeam · corrodedAFT CARGO COMPARTMENT FLOORBEAM CORRODED BETWEEN BS 787 TO BS 823, RBL 15. REPAIRED FLOORBEAM PER SRM AND EA.SDR SCNA20190907137Floorbeam · corrodedPASSENGER COMPARTMENT FLOOR BEAM AT STA 986.5 LBL 43.5 CORRODED AT FASTENER HOLE ON TOP FLANGE. REMOVED CORROSION ON THE TOP FLANGE OF FLOORBEAM @ STA 986.5, LBL43.5. ORIGINAL THK .150", REMOVED .020", REMAINING THK .130", FOUND BEYOND ALLOWABLE DAMAGE LIMITS.SDR SCNA20190907136Floorbeam · corrodedPASSENGER COMPARTMENT FLOOR BEAM AT STA 986.5 RBL 34 CORRODED AT FASTENER HOLE ON TOP FLANGE. FS 986.5 FLOORBEAM REPLACEMENT AND REPAIR.SDR SCNA20190907135Floorbeam · corrodedPASSENGER COMPARTMENT FLOORBEAM AT STA 986.5 RBL 29.5 CORRODED AT FASTENER HOLE ON TOP FLANGE. FS 986.5 FLOORBEAM REPLACEMENT AND REPAIR.SDR SCNA20190907134Floorbeam · corrodedPASSENGER COMPARTMENT FLOORBEAM AT STA 986.5 RBL 43.5 CORRODED AT FASTENER HOLE ON TOP FLANGE. FS 986.5 FLOORBEAM REPLACEMENT AND REPAIR.SDR DALA2019090705199Floorbeam · corrodedCORROSION LEVEL: 2. CORROSION FLOORBEAM +Y254 LOCATED BTW FR 12 TO FR 24 AT FWD GALLEY AREA (1 EA). REPLACED FLOORBEAM +Y254 LOCATED BTW FR12 TO FR24 AT FWD GALLEY AREA (1E/A) AS PER SRM 51-72-11, SRM A319 51-42-11 AND DWG #D53-110920 ISSUE "D", D53110984 ISSUSDR DALA2019090705198Floorbeam · corrodedCORROSION LEVEL: 2. CORROSION FLOORBEAM -Y765 BTW FR67 TO FR68 AT AFT GALLEY AREA ( SSI 534147). REPLACED FLOORBEAM -765 LOC FR 66 TO FR 70 AT AFT GALLEY AREA ASPER SRM 51-72-11 AND DWG #D53472104202 AND ISSUE: A,B,E RELEASE DATE:17-DEC-15, MEASURE OF CORROSIOSDR SWAA2022031657590Seat Track · corroded***CORROSION*** FIRST OFFICER'S FWD INBOARD AND OUTBOARD SEAT TRACKS HAVE CORROSION / REMOVED AND REPLACED FO'S FWD INBOARD AND OUTBOARD SEAT TRACKS IAW AMM 25-11-11-400-801 STEPS 3.D.(2)(3)(D)(4-8) AND SOPM 20-50-01 56572U 06SEPT19 PRIOR TO REPLACEMENT OF FO'SDR SWAA2022031657591Seat Track · corroded***CORROSION*** CAPTAINS'S FWD INBOARD AND OUTBOARD SEAT TRACKS HAVE CORROSION / REMOVED AND REPLACED CAPTS FWD INBOARD AND OUTBOARD SEAT TRACKS IAW AMM 25-11-11-400-801 STEPS 3.D.(2)(3)(D)(4)(5)(6-8) AND SOPM 20-50-01 56572U 06SEPT19 PRIOR TO CAPTAINS SEAT TRSDR AALA201909259018Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LONGITUDINAL FLOOR BEAM BETWEEN FR 66 AND FR 70 AT +Y765. REPLACED FLOOR BEAM PER SRM 51-72-11.SDR SWAA2019092636951Floorbeam · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE FLOOR TRACK CORRODED AT BS 767+5, RBL 8. R&R FLOORBEAM IAW SRM AND EA.SDR KCSA201909051211Floorbeam · corrodedFWD PIT UPPER CHORD FLOORBEAM HAS EVIDENCE OF CORROSION STA 434 LBL 50.SDR SWIA2019100446408Floorbeam · crackedRH FS280.00 CENTER FLOOR BEAM CLIPS ARE BOTH CRACKED. (C-CHECK) RO: 10/01/2019 REMOVED CRACKED ANGLE AND INSTALLED NEW CLIP ANGLE ON R/H SIDE INBD OF FLOOR BEAM AT RBL18 IAW REO.SDR ASAA2019090430727Floorbeam · damagedFLOORBEAM @ STA 727I LH HAS PULLED THRU FASTENED- DOT & STREAMER ATTACHED. GROUNDED - YES. REMOVED AND REPLACED DAMAGED ZEE CHANNEL SECTION FROM LT STA 727 TO 827+8 IAW SRM 53-00-53-2R-5 REPAIR 5.SDR CALA2019090901506Floorbeam · corrodedB757-53-3-0551 (SECONDARY FINDING)MAIN CABIN FWD FLOORBEAM AT A PPROX STA 345 RBL 2-LBL 40 HAS CORROSION,16-126 REF ENGINEERING N/R 0073053 REMOVED CORROSION FROM MAIN CABIN FLOORBEAM UPP CAP STA 345 RBL 2 TO LBL 40 (L=22 X W=2 D=.028) FOUND TO BE OUT OF LIMITSDR DALA2019090505169Floorbeam · corrodedCORROSION LEVEL: 2. CORROSION FLOORBEAM +Y1292 AT LEVEL FR 16 FWD GALLEY AREA (1 EA ) (SSI 531189). REPLACED FLOORBEAM +Y1292 BTW FR12 AND FR24 FWD GALLEY AREA AS PER SRM 51-72-11 AND DWG D53112812.SDR DALA2019090405133Floorbeam · corrodedCORROSION LEVEL: 2. CORROSION FLOORBEAM -Y1292 FR 67 AT AFT GALLEY AREA (SSI 534147 ). REPLACED FLOORBEAM -Y1292 FR67 TO FR68 AT AFT GALLEY AREA ASPER SRM 51-42-11 SRM 51-72-11 AND DWG D53472000 ISSUE S RELEASE DATE 06-JAN-05 MEASUREMENTS OF CORROSION IS L=1.1SDR DALA2019090405132Floorbeam · corrodedCORROSION LEVEL: 2. CORROSION FLOORBEAM -Y1292 AT FR68 AT AFT GALLEY AREA (SSI 534147). REPLACED FLOORBEAM -Y1292 AT FR 68 TO FR 69 AFT GALLEY AREA ASPER SRM 51-42-11 SRM 51-72-11 AND DWG D53472001 ISSUE K RELEASE DATE 25-OCT-17 MEASUREMENTS OF CORROSION IS L=SDR SWAA2022031506800Tie Down · crackedAFT CARGO PIT FLOOR TRACK STA 747 RBL 13.8 IS CRACKED IN RADIUS OF MOUNTING TAB UNDER TIEDOWN / REPLACED CRACKED TIE DOWN TRACK FROM STA 727-747; RBL 13.8 I.A.W B737 SRM 51-40-02 & BOEING DWG # 146A7500 TY:DWG;ID:0062; REV:-SDR SWIA2019101746489Angle · crackedCLIPS ATTACHING L/H AND R/H FLOOR BEAMS TO THE FS280 BEAM AT L/H AND R/H BL9 ARE CRACKED. (C-CHECK) RO: 10/16/2019 REMOVED AND INSTALLED NEW R/H CLIP P/N: 601R31113-58 AT FS 280 FLOOR BEAM RBL 9 IAW SRM.SDR SWAA2019093037414Floorbeam · corrodedAFT CARGO PIT FLOOR BEAM CORRODED ON UPPER SURFACE AT BS. 767+6, RBL 3. / REPAIRED FLOOR BEAM PER SRM.SDR SWAA2019092537017Floorbeam · corrodedAFT CARGO PIT FLOORBEAM CORRODED ON UPPER SURFACE AT BS 767+6, LBL 8.1. REPAIRED CHANNEL PER EA.SDR SWAA2019092537016Floorbeam · corrodedAFT CARGO PIT FLOORBEAM CORRODED ON UPPER SURFACE AT BS 767+6, LBL 3. REPAIRED CHANNEL PER EA.SDR SWAA2019092537015Floorbeam · corrodedAFT CARGO PIT FLOORBEAM CORRODED ON UPPER SURFACE AT BS 767+6, RBL 8.1. REPAIRED CHANNEL PER EA.SDR SWAA2019091636979Floorbeam · corrodedFLOORBEAM CORRODED AT BS 328, BETWEEN LBL 0 TO RBL 62. REPAIRED UPPER CHORD IAW SRM.SDR SWIA2019101746502Strap · corrodedTHE RH FLOOR STRAP LOCATED AT FS559 BETWEEN RBL27 AND RBL45 HAS MULTIPLE SPOTS OF CORROSION. (C-CHECK) RO: 10/16/2019 REMOVED CORROSION ON THE RH FLOOR STRAP LOCATED AT FS559.0 BETWEEN RBL27 AND RBL45 IAW SRM. REMOVED CORRODED RH FLOOR STRAP AND INSTALLED NEW SDR SWIA2019101746500Floorbeam · corrodedRIGHT FLOOR BEAM RBL 9 OUTBOARD EDGE CORRODED AT FS 559.0+76 TO FS 559.0+80 MARKED (C-CHECK) RO: 10/16/2019 REMOVED CORROSION ON RH FLOOR BEAM OTBD EDGE AT FS 559+76 TO 559+80 IAW SRM. ACCOMPLISH THE FLOOR BEAM REPAIR AT FS559.0+76 TO FS559.0+80 RBL9.0 THE OSDR SWIA2019101746486Floorbeam · damagedTHE PRESSURE FLOOR'S LH INTERCOSTAL LOCATED AT FS484 BETWEEN LBL27 AND LBL45 HAS CRACKED INBOARD AND OUTBOARD ATTACH CLIPS. (MARKED WITH ORANGE FLAG TAPE) (C-CHECK) RO: 10/16/2019 REMOVED DAMAGED INTERCOSTAL ATTACHEMENT CLIPS AT FS484.00 BETWEEN LBL27 AND LBL4SDR SWAA2019090336457Floorbeam · corrodedCABIN FLOORBEAM CORRODED AT FASTENER HOLES BS. 986.5, BETWEEN RBL 12 TO RBL 44. R&R FLOORBEAM PER SRM.SDR SWAA2019090336455Floorbeam · corrodedCABIN FLOORBEAM CORRODED AT FASTENER HOLES BS. 986.5, LBL 43. R&R FLOORBEAM PER SRM.SDR SWAA2022031818660Beam · corroded***CORROSION*** IN MULTIPLE AREAS OF AFT CABIN FLOOR BEAM STA 987 RBL 28-45 WL 208 / REPAIRED THE FLOOR BEAM AT STA 987 RBL 28-45 WL 208. (986.5) IAW EA 1-A53-8241 R3 (T978916)SDR A6WA2019090946851Floorbeam · corrodedLBL27 CARGO FLOORBEAM HAS CORROSION AROUND ONE NUTPLATE HOLE AT FS559+ 114.SDR N6WA201908302901Floorbeam · crackedL/H SIDE OF FS280 FLOORBEAM WAS CRACKED. REPAIRED THE FLOORBEAM IAW EO C700-53MR-011-O.SDR 9WGA20190829106Floorbeam · corrodedMAIN CARGO FLOOR BEAM CORROSION STA. 495 BL 48R. NON-ROUTINE 1554.SDR FOTR20190829002Tee Fitting · damagedAFT CABIN BS 1640 FLOOR BEAM UPPER TEE CHORD HAS 3 EACH ELONGATED HOLES BETWEEN LBL 25 & LBL 45SDR SWAA2019100137358Splice · corrodedAFT CARGO BAY FLOOR SUPPORT SPLICE CORRODED AT BS. 887, BETWEEN LBL 8 TO RBL 8. R&R FLOOR SUPPORT SPLICE IAW SRM AND DWG.SDR AALA201909219005Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM UPPER FLANGE AT BS 987 BETWEEN LBL 28 AND LBL 45. REPAIRED FLOORBEAM PER SRM 53-70-51-2R-4.SDR AALA201909179018Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT WET AREA FLOORBEAM UPPER FLANGE AT BS 947.5 AND LBL 4. REPAIRED FLOORBEAM PER SRM 53-70-51-2R-5 AND EA 297899.SDR SWAA2019091636997Floorbeam · crackedFLOOR STRUCTURE CRACKED AT BS 294.5, BETWEEN RBL 27 TO RBL 61. REPAIRED FLOOR BEAM IAW SRM AND DWG.SDR SWAA2019091336868Floorbeam · corrodedAFT CARGO BAY BULKHEAD TO FLOOR SUPPORT CORRODED AT BS 947, BETWEEN LBL 10 TO RBL 22. R&R SUPPORT IAW SRM AND DWG.SDR DALA2019082905185Floorbeam · corrodedCORROSION FLOORBEAM -Y1292 AT LEVEL OF FR 68 AT AFT GALLEY AREA, REPLACED FLOORBEAM -Y1292 LOC. FR68 AT AFT GALLEY AREA ASPER SRM 51-72-11 AND 51-42-11, DWG # D53472000.SDR DALA2019082905184Floorbeam · corrodedCORROSION FLOORBEAM -Y765 AND FR 20 AT FWD GALLEY AREA, REPLACED FLOORBEAM -765 LOC FR 12 TO FR 24 AT FWD GALLEY AREA ASPER SRM 51-72-11 AND 51-42-11 DWG 53112812.SDR DALA2019082905183Floorbeam · corrodedCORROSION FLOORBEAM -Y1292 BTW FR 67 AND FR 68 FLOOR STRUCTURE AT AFT GALLEY AREA, REPLACED FLOORBEAM-Y1292 LOC. FR 68 AT AFT GALLEY AREA AS PER SRM 51-72-11 AND 51-42-11, DWG # D53472000.SDR YENA201908280494Floorbeam · corrodedDURING HEAVY MAINTENANCE, FWD CABIN, LT FLOOR SUPPORT, FR 20 BEAM Y1292 HAS CORROSION AND SCRIBE LINE; REFERENCE NR 440577-20520 REMOVED CORROSION ON FLOORBEAM Y1292 FR 20 REMOVED .040" IN AN AREA L'2.0" X W2.0" FOUND TO BE OUT OF LIMITS PER SRM. REMOVED AND RSDR UIEA2019082105243Floorbeam · damagedM/D - STA 1200, LBL 33 TO 55, FLOOR SUPPORT HOLE ELONGATED. M/D STA 1200, LBL 33 TO LBL 55, FLOOR SUPPORT REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER AMM 20-51-01.SDR UIEA2019081305021Floorbeam · corrodedCABIN - STA 940, BL 0 TO RBL 60 FLOORBEAM FOUND CORROSION. CORROSION REMOVED AS PER SRM 51-10-02. BLEND OUT DEPTH 0.040", ORG 0.128", WIDTH 1-2", LENGTH 7" OUT OF SRM 53-00-51 ALLOWABLE DAMAGE 1 FIG 101 LIMIT. CABIN - STA 940, BL 0 TO RBL 60 FLOORBEAM REPAIREDSDR UIEA2019083105370Floorbeam · corrodedM/D - STA 1220, RBL 99 - 115, FLOOR BEAM FOUND CORRODED. M/D - STA 1220, RBL 99 - 115, FLOOR BEAM CORROSION REMOVED AND RE-PROTECTED AS PER SRM 51-10-02 AND SRM 51-20-01. BLEND OUT DEPTH 0.011", ORG 0.090", WIDTH 1.2", LENGTH 8" WITHIN SRM 53-00-51 ALLOWABLE D
Back to JASC 5315