JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2018090405410Floorbeam · corrodedDURING INSPECTION FOUND CORROSION ON FLOORBEAM STA Y= 947 AND RBL 50 PAX CABIN. FLOORBEAM STA Y= 947 AND RBL 50 PAX CABIN WAS REPAIRED PER SRM 53-70-51 REPAIR 5. FLOORBEAM STA Y= 947 AND RBL 50 PAX CABIN WAS REPAIRED PER SRM 53-70-51 REPAIR 5.SDR SWAA2018092825612Floorbeam · corrodedFLOORBEAM T-CAP CORRODED AT BS 294.5, BETWEEN RBL 5 TO RBL 13. REPAIRED T-CAP IAW SRM & EA.SDR FDEA2018090512301Floorbeam · corrodedCORROSION ON ANCHOR NUT STRIPS UNDER FLOORBEAM AT BSTA 1682 LBL 47 TO RBL 52. REMOVED DAMAGE AND EVALUATED UPPER FWD FLANGE IAW SRM 51-10-02 AND SRM 53-00-51-1A. FOUND 1 AREA OUT OF LIMITS. PERFORMED REPAIR AT BS 1681.8 UPPER FORWARD FLANGE AREA LBL 47 IAW SRSDR DALA2018090405408Floorbeam · corrodedDURING INSPECTION FOUND INITIAL INSPECTION: CORROSION ON FLOORBEAM STA Y=312 LBL 11 AT PAX CABIN ( W1 ). CORROSION LEVEL 2. FLOORBEAM STA Y=312 LBL 11 WAS ACCOMPLISHED SECTION I AS PERMANENT REPAIR PER ETI-37-18 -486 REV 1 AND ER/A 571228-14 REV ORIG.SDR SWAA2018101025860Floorbeam · corrodedFLOORBEAM CORRODED AT BS 967, LBL 33. REPAIRED FLOORBEAM IAW EA AND ER.SDR SWAA2018101025859Floorbeam · corrodedFLOORBEAM CORRODED AT BS 967, LBL 27. REPAIRED FLOORBEAM IAW EA AND ER.SDR SWAA2018101025858Floorbeam · corrodedFLOORBEAM CORRODED AT BS 986.5, BETWEEN RBL 20 TO RBL 45. REPAIRED FLOORBEAM IAW ER AND EA.SDR SWAA2018101025857Floorbeam · corrodedFLOORBEAM CORRODED AT BS 986.5, BETWEEN LBL 20 TO LBL 45. REPAIRED FLOORBEAM IAW ER AND EA.SDR SWAA2018092425473Floorbeam · crackedFLOORBEAM CRACKED AT BS 328, RBL 24. REPAIRED FLOORBEAM PER SRM.SDR R61A2018091320955Floorbeam · corrodedWHILE PERFORMING HEAVY MAINTENANCE TECHNICIANS FOUND CABIN FLOOR STRUCTURE AT FR 87-88 WEB WITH CORROSION AROUND FASTENER HOLES RBL 24-38". FOUND TO BE OUT OF LIMITS PER SRM 53-23-10. REMOVED AND REPLACED WEB IAW SRM 51-40-08 AND ETD 2011-190/01333 REV C. A/C SDR FDEA2018090502299Floorbeam · crackedTHE STUB BEAM AT STA 580 LT SIDE IS CRACKED AND REQUIRES REPAIR. REPAIRED CRACKED STUB BEAM AT BSTA 580 LBL 45 IAW EA F-5310-T0341592.SDR REXA2018091400840Floorbeam · corrodedAFT CARGO FLOOR FRAME LBL27 AT FS1031 HAS CORROSION. REPAIRED FLOORBEAM IAW REO 670-53-00-029.SDR ASAA2018091226104Floorbeam · corrodedSTA 986 FLOORBEAM UPPER FLANGE CORRODED BETWEEN LBL32 AND RBL 32. GROUNDED - YES. REPAIRED 986 BEAM UPPER CHORD IAW SRM 53 70 51 2R 4 W 1" O .150" R .130" L 1" D .020".SDR ASAA2018090626031Floorbeam · corrodedSTA 947 FLOORBEAM UPPER FLANGE CORRODED BETWEEN RBL1 AND RBL8. GROUNDED - YES. REPAIRED FLOORBEAM IAW SRM 53 00 51 2R 1 W 1" O .180 R .122 L 4" D .058.SDR AALA2018083028003Floorbeam · corrodedCORROSION FOUND ON THE FLOORBEAM FLANGE AT BS 947 AND LBL 52 - 53. REPLACED THE FLOORBEAM IAW SRM 53-70-51-2R-5.SDR DALA2018082905345Floorbeam · corrodedDURING INSPECTION FOUND CORROSION ON FLOORBEAM, BS 887, BETWEEN STRINGERS 25L & 26R , IN THE AFT CARGO BAY. THE FLOORBEAM WAS REPLACED IAW SRM 51-40-02, AND DWG 146A9401, REV C.SDR SIMA20180828001Tee Fitting · crackedATTACH ANGLE ON THE AFT SIDE OF FLOORBEAM AT BS 280, LBL 9 WAS CRACKED .250 INCHES. INSTALLED A NEW FABRICATED TEE BRACKET ATTACH ANGLE IAW SRM 51-21-26 AND 51-42-21.SDR YENA2018101060631Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM INBD POSITION RT LOCATED BTWN FR 12-20 AT FWD GALLEY AREA. CORROSION IS BEYOND LIMITS AS PER SRM 53-10-10; REPLACED FLOORBEAM LOCATED AT FR 12-20 RT SIDE PASSENGER CABIN IAW SRM 51-40-08 AND DRAWISDR YENA2018101050630Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM, FILLER AT FR 17, STR 17R. NO SPECIFIC ALLOWABLE DAMAGE REFERENCE IN THE SRM, THEREFORE THE DAMAGED PART WILL REQUIRE REPLACEMENT; REMOVED AND REPLACED THE FLOOR BEAM FILLER LOCATED AT FR17, STR 1SDR YENA2018101050629Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM, FILLER, LOCTATED ON FR17, STR 17R, HAS CORROSION THAT IS BEYOND LIMITS. NOTE: THERE IS NO SPECIFIC SRM LIMIT FOR THIS SPECIFIC PART, THEREFORE IT WAS DETERMINED TO REPLACE IT; REMOVED AND REPLACESDR YENA2018101050628Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM, UPPER SURFACE, LOCATED ON FR 17, + .617", STGR 17R, IS BEYOND ALLOWABLE SRM LIMITS; REMOVED AND REPLACED FLOORBEAM (P/N: 170-03263-001, TRACK, RIGHT-FLOOR, FWD.) LOCATED BTW FR 12 AND FR 20, PER SDR ASAA2018091926164Floorbeam · corrodedMAIN CABIN FLOORBEAM AT BODY STATION 947.5 CORRODED AT LBL 16. GROUNDED - YES. REMOVED CORROSION IAW SRM 53-70-15-1A-1 FIG 104 DET D. ORIGINAL THICKNESS .180" REMOVED, .059" REMOVING .121" FOUND TO BE OUT OF LIMITS. FABRICATED, MODIFIED, ALODINED, PRIMED, AND SDR DALA2018082705284Tee Fitting · corrodedDURING INSPECTION, FOUND THE AFT CARGO FLOORBEAM TEE WAS CORRODED AT BS 772. REPLACED THE TEE IAW DWG 146A9401.SDR ASAA2018091726130Floorbeam · corrodedMAIN CABIN FLOORBEAM STA 986.5 UPPER CAP IS CORRODED AT FASTENER HOLES NUMEROUS LOCATIONS. GROUNDED - YES. REMOVED CORROSION. ORIG. 150, REMAIN 125, LOSS OF .025. FOUND OUT OF LIMITS IAW SRM 53-70-57. ACCOMPLISHED T CAP REPAIR IAW SRM 53-70-51.SDR FDEA2018082942181Floorbeam · crackedON REMOVAL OF THE FLOOR PANEL, LT BS 475, LBL 77.5 - 87.5 FLOORBEAM AT LBL 68 WAS FOUND DAMAGED. REPAIRED IAW EA 1- 5321-T0341774, PART 1. THE REPAIR WAS CLASSIFIED AS MAJOR IAW GMM 6-2-100.SDR AALA201808279039Floorbeam · corrodedCORROSION FOUND ON THE HARD POINT MOUNT OF THE FLOORBEAM Y-1292 ABOVE FRAME 66. REPAIRED THE FLOORBEAM IAW SRM 51-42-11, 51-72-11, DRAWINGS D53422832 AND D53472816.SDR ASAA2018082426201Floorbeam · corrodedCABIN FWD WET AREA SECT 41 STA 344 LBL 24 TO RBL 11 FLOORBEAM CORR ON UPPER FLANGE. GROUNDED - YES. REMOVED CORROSION ON FLOORBEAM UPPER FLANGE, FOUND TO BE BEYOND ALLOWABLE LIMITS (ORIG .125 REMOVED .060", REMAINING .065") REFERENCE SRM 53-10-51 AP1. REMOVED SDR AALA2018082879038Floorbeam · corrodedCORROSION WAS FOUND ON THE FLOORBEAM AT FRAME 66, -Y765, AND WL Z-500. REPLACED THE FLOORBEAM IAW D53472780, AND SRM 51-42-00.SDR AALA2018082879036Floorbeam · corrodedCORROSION FOUND ON THE FLOORBEAM, FRAME 70, -Y765, AND WL Z-500. REPLACED THE FLOORBEAM IAW D53472780, AND SRM 51-42-00.SDR A6WA2018082846002Angle · crackedFLOORBEAM OTBD ANGLE AT BS 280, RBL 9 WAS CRACKED. REPLACED THE FLOORBEAM ANGLE.SDR A6WA2018082846003Angle · crackedFLOORBEAM INBD ANGLE AT BS 280, LBL 9 WAS CRACKED. REPLACED THE ANGLE.SDR A6WA2018082846001Angle · crackedFLOORBEAM OTBD ANGLE AT BS 280, LBL 9 WAS CRACKED. REPLACED THE ANGLE.SDR SWAA2018100125640Floorbeam · corrodedBEAM UPPER AND LOWER SURFACE CORRODED AT BS 986, RBL48. REPAIRED BEAM PER ER AND EA.SDR CALA2018082701841Floorbeam · crackedBS 780, LBL 11 FLOOR BEAM WAS FOUND CRACKED. THE FLOORBEAM WAS REPAIRED IAW SRM 53-00-51, REPAIR 3, FIG 201.SDR FDEA201808212137Floorbeam · corrodedMAIN DECK CARGO TEE FITTIN FLOORBEAM WAS CORRODED AT FRAME 15, -Y1959. CORROSION EXCEEDED SRM ALLOWABLE LIMITS, REMOVED AND REPLACED THE TEE FITTING IAW SRM 51-40-20, AND DWG A53212550.SDR AALA201808221005Floorbeam · corrodedCORROSION FOUND ON CABIN FLOOR STRUCTURE ZEE CHANNEL FLOORBEAM AT BS 993 33R-46R. REPLACED FLOORBEAM ANGLE IAW SRM 51-40-02 AND 51-00-05.SDR AALA201808221008Floorbeam · corrodedCABIN FLOOR STRUCTURE HAS CORROSION ON FULL TOP SURFACE OF FLOOR BEAM LOCATED AT STA 986.5. REPAIRED BEAM PER SRM 53-70-51-2R AND 51-40-02.SDR SWIA2018091245065Floorbeam · corrodedCARGO, FLOORBEAM CORRODED FS568 - FS611 LBL27. (C-CHECK) RO: 09/12/2018. REPAIRED OTBD FLANGE IAW SRM AND REO.SDR A6WA2018082145997Floorbeam · crackedBS 280 FLOORBEAM WAS CRACKED AT RBL 9. REPLACED THE FLOORBEAM IAW SRM 51-42-06.SDR AALA20180820005Floorbeam · corrodedCORROSION FOUND ON THE FLOORBEAM BS 993, BETWEEN LBL 33 TO LBL 46. REPAIRED THE FLOORBEAM IAW DRAWING 147A5700, 51-00-05-1, AND SRM 51-40-02.SDR A6WA2018082145996Floorbeam · crackedFLOORBEAM INBD ANGLE CRACKED AT BS 280, RBL 9. REPLACED THE ANGLE IAW SRM 51-21-43, 51-31-59, 51-24-36, AND 51-41-21.SDR SWAA2018090424774Floorbeam · corrodedMAIN CABIN FLOORBEAM CORRODED AT BS 967, RBL 28. R&R FLOORBEAM IAW SRM & EA.SDR AALA201808209020Floorbeam · corrodedCORROSION FOUND ON THE FLOORBEAM AT FRAME 65. REPLACED THE FLOORBEAM IAW SRM 51-72-11.SDR DALA2018082005154Floorbeam · corrodedDURING INSPECTION, FOUND CORROSION ON THE FLOORBEAM BS 947.5, BETWEEN LBL 40 - 52. THE FLOORBEAM WAS REPAIRED IAW SRM 53-70-51, REP 5.SDR IPXA2018082983299Floorbeam · crackedLOWER CENTER CARGO, BS 1521, FLOORBEAM ANGLE WAS CRACKED BETWEEN LBL 8 TO LBL 25. REMOVED, FABRICATED, AND REPLACED THE FLOORBEAM ANGLE IAW DWG AEA0341, AND SRM 51-35-01. MINOR.SDR YENA2018101070623Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON RT FLOORBEAM -Y1292 UPPER SURFACE AT FR 66; REPLACED FLOORBEAM. WORK ACCOMPLISHED ON NR 24381.SDR YENA2018101070622Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON RT FLOORBEAM AY -Y1292, FRAME 68 +10.00", STR 23R. HAS CORROSION THAT IS OUT OF LIMITS AFTER BLEND-OUT WAS PERFORMED; BLENDED CORROSION IAW SRM 51-74-00, FROM RT FLOORBEAM -Y1292, FR 68 +10.00". DAMAGE IS SDR YENA2018101070620Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LT FLOORBEAM AT Y1292, FRAME 67 +12.00". HAS CORROSION THAT IS BEYOND LIMITS AFTER BLEND-OUT (REF. 53-00-14-283-002, FIG 001, SHT 1); REMOVED AND REPLACED LT FLOORBEAM (P/N: D5347217220400) AT Y1292, FRAME SDR YENA2018101070619Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LT FLOORBEAM Y1292 AT FR 67 +15; REMOVED AND REPLACED LT FLOORBEAM Y1292 FR 68-69 STR 23L IAW SRM 51-42-11 & 51-72-11; REF NR 24397.SDR YENA2018101070615Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LT CABIN FLOORBEAM Y1292 AT FR 66 +3.00"; BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS PER SRM 53-0014-283-002, FIG 001. REF. NR 24396. NOTE: FLOORBEAM AT Y1292, FR66 WAS REPLACED ON NR 24395.
Back to JASC 5315