JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YENA2018101050670Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM FROM FR 66 + 4" TO FR 67 + 16" BTW +Y1292 & +Y1162 AFT GALLEY AREA; REPLACED FLOORBEAM FROM FR 66+ 4" TO FR 67 + 16" BTW +Y1292 TO +Y1162 AFT GALLEY AREA . IAW A320 SRM 51-72-11 AND DWG D53472780SDR ASOA2018092065207Floorbeam · corrodedLEFT HAND FLOORBEAM LBL 27 UPPER O/B FLANGE IS CORRODED AROUND MULTIPLE FASTENER HOLES BETWEEN FS 621 TO FS 559+110. COMPLIED WITH ECTC REO 601R-53-61-3778.SDR SWAA2022022318682Floor Support · crackedCRACKED FLOOR SUPPORT BS 344-360 BL0 WL 208 / REMOVED NON-SERVICEABLE PART AND DRILLED NEW FLOOR SUPPORT IAW SRM 51-40-05-0G-0 AND DWG 141A5400. LOCATED AT BS 344-360 BL0 WL208. 92978U 23SEP18 OK TO INSTALL. 92978U 23SEP18 INSP 358 09/23/18 INSTALLED NEW FLOORSDR SWAA2022022318683Floor Support · crackedCRACKED FLOOR SUPPORT BS 277-344 BL 0 WL 208 / REMOVED FLOOR SUPPORT AND DRILLED NEW FLOOR SUPPORT AT BS 277-344 BL0 WL208. IAW SRM 51-40-05-0G-0 AND DWG 141A5400. 92978U 23SEP18 OK TO INSTALL 92978U 23SEP18 INSP 358 09/23/18. INSTALLED NEW FLOOR SUPPORT B.S. SDR SWAA2018101125888Floorbeam · corrodedFLOORBEAM UPPER CHORD CORRODED AT BS 986, BETWEEN RBL 43 TO RBL 45. REPAIRED CHORD PER ER AND EA.SDR YENA2018101040658Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM +Y 1292 AT FRAME 16 AT FWD GALLEY AREA; REPLACED FLOORBEAM + Y 1292 AT FR 12 TO FR 24 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG 53112816. ALL WORK ACCOMPLISHED ON NR 2018-250238.SDR YENA2018101040657Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM +Y 1292 AT FRAME 16 AT FWD GALLEY AREA; REPLACED FLOORBEAM + Y1292 AT FR 12 TO FR 24 AT FWD GALLEY AREA IAW SRNM 51-72-11 AND DWG 53112816. ALL WORK ACCOMPLISHED ON NR 2018-250238.SDR YENA2018101040656Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM + 503 AT FRAME 16 AT FWD GALLEY AREA; REPLACED FLOORBEAM + 503.2 AT FRAME 16 AT FWD GALLEY AREA IAW SRM 51-72-11, SRM 51-42-11 AND DRAWING D53112825, D53110984 ALL WORK ACCOMPLISHED ON NR 2018-2SDR YENA2018101040655Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM + Y 254 AT FRAME 16 AT FWD GALLEY AREA; PERFORMED REPAIR LOC. FLOORBEAM + Y 254 AT FWD GALLEY AREA IAW SRM 53-11-14-300-001 ALL WORK ACCOMPLISHED ON NR 2018 -250241.SDR YENA2018101040654Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM + Y 254 AT FRAME 16 AT FWD GALLEY AREA; PERFORMED REPAIR LOC FLOORBEAM + Y 254 AT FWD GALLEY AREA IAW SRM 53-11-14-300-001 .ALL WORK ACCOMPLISHED ON NR 2018-250251.SDR CALA2018091701941Floorbeam · corrodedCABIN FLOORBEAM AT BS 303 / LBL52 HAS CORROSION. RECEIVED AND ACCOMPLISHED ECRA 5321-01964 STA 303 FLOORBEAM UPPER CHORD REPAIR, PERMANENT INSTRUCTIONS AND FIGURES NR 2013742-38.SDR CALA2018091701940Floorbeam · corrodedCABIN PASSENGER FWD WET AREA AT FLOORBEAM STA 325 APROX LBL 52" FOUND CORROSION . RECEIVED AND ACCOMPLISHED EC/RA 5321-01965, PERMANENT REPAIR INSTRUCTIONS AND FIGURES STA 325 FLOORBEAM UPPER CHORD REPAIR.SDR FDEA2018091432523Floorbeam · corrodedCORROSION "T" CAP FLOORBEAM MAIN CARGO CABIN STA 1661 LBL 18. REMOVED CORROSION FROM MAIN CABIN FLOOR BEAM "T" CAP, MATERIAL LOSS ".019 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51-1A DETAIL III. REMOVED DAMAGED "T" CAP, FABRICATED NEW "T" CAP FROM BAC1505-1008SDR IPXA2018092874481Floorbeam · crackedTHE FLOORBEAM WAS CRACKED AT STATION 6-70, LBL 57.5 AND WL 98. REPAIRED THE FLOORBEAM IAW SRM 53-40-51, REPAIR 1, FIG 201. MAJOR.SDR IPXA2018092654387Floorbeam · crackedFLOORBEAM WAS CRACKED AT STATION 6-70 ABOVE LONGERON 43L. REPAIRED THE FLOORBEAM IAW SRM 53-40-51, REPAIR 1, FIGURE 201. MAJOR.SDR FDEA2018091422476Floorbeam · crackedMAIN CABIN FLOOR STA 580 LBL 45.5 STUB FLOORBEAM IS CRACKED AFT SIDE IN RADIUS COMPLIED WITH EA TF-5310-T0342277 P1. FLOORBEAM SPLICE SEGMENT UPPER AFT FLANGE CRACK REPAIR LBL 45.5.SDR YENA2018101010649Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM -Y254 BTW FR 12 TO 18 AT FWD GALLEY AREA; REPLACED FLOORBEAM -Y254 IAW SRM 51-72-11. WORK ACCOMPLISHED ON NR 2018-261159.SDR YENA2018101010648Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM +Y254 AT FRAME 18 +3 INCHES AT FWD GALLEY AREA; PERFORMED PERMANENT REPAIR LOCATED ON FLOORBEAM +254 AT FRAME 18 +3 IAW SRM 53-11-14-300-002. WORK ACCOMPLISHED ON NR 2018-261162.SDR YENA2018101010647Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM -Y765 BTW FR 67 TO FR 69 AFT GALLEY AREA; REPLACED FLOORBEAM -Y765 IAW SRM 53-72-11. WORK ACCOMPLISHED ON NR 2018-261212.SDR YENA2018101010646Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM -Y765 BTW FR 67 TO FR 69 AFT GALLEY AREA; REPLACED FLOORBEAM IAW SRM 53-72-11. WORK ACCOMPLISHED ON NR 2018-261212.SDR YENA2018101010645Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM -Y765 BTW FR 67 TO FR 69 AFT GALLEY AREA; REPLACED FLOORBEAM -Y765 IAW SRM 51-72-11. WORK ACCOMPLISHED ON NR 2018-261212.SDR YENA2018101010644Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM -Y765 BTW FR 67 TO FR 69 AFT GALLEY AREA; REPLACED FLOORBEAM -Y765 IAW SRM 51-72-11. WORK ACCOMPLISHED ON NR 2018-261212.SDR YENA2018101010641Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON BEAM FLOOR STRUCTURE LOCATED AT +Y1175 AND FR68 AT AFT GALLEY AREA; REPLACED FLOORBEAM LOCATED +Y1175 AND BTW FR 67+18" TO FR 69 IN AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472780.SDR YENA2018101010640Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON BEAM FLOOR STRUCTURE LOCATED AT +Y1175 + AND FR 68 AT AFT GALLEY AREA; REPLACED FLOORBEAM LOCATED AT +Y1175 IAW SRM 51-72-11. REF NR 2018-261213.SDR YENA2018101010639Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM Y765 BETWEEN FR 67 TO FR 69 AT AFT GALLEY AREA; REPLACED FLOORBEAM Y765 IAW SRM 51-72-11. WORK ACCOMPLISHED ON NR 2018-261211.SDR YENA2018101010638Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM Y765 BETWEEN FR 67 TO FR 69 AT AFT GALLEY AREA; REPLACED FLOORBEAM Y765 IAW SRM 51-72-11. WORK ACCOMPLISHED ON NR 2018-261211.SDR YENA2018101010637Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM LOCATED -Y1175 AND FR 68 AT AFT GALLEY AREA; REPLACED FLOORBEAM IAW SRM 51-72-11. WORK ACCOMPLISHED OM NR 2018-261214.SDR YENA2018101010636Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM LOCATED -Y1175 AND FR 68 AT AFT GALLEY AREA; REPLACED FLOORBEAM IAW SRM 51-72-11. WORK ACCOMPLISHED ON NR 2018-621214.SDR YENA2018101010635Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOORBEAM LOCATED -Y1175 AND FR 68 AT AFT GALLEY AREA; REPLACED FLOORBEAM IAW SRM 51-72-11. WORK ACCOMPLISHED ON NR 2018-261214.SDR AALA201809219003Angle · corrodedCORROSION ON FLOORBEAM ANGLE AT FRAME 68, +Y1292. REPAIRED THE FLOORBEAM ANGLE IAW SRM 53-41-14-300-001, REPAIR PRINCIPAL 7.SDR FDEA2018091412454Floorbeam · corrodedCORROSION ON FLOORBEAM LBL 58- RBL 58 BS 1200. FLOORBEAM FOUND TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-51-1A FIG 101 DETAILIII REV 124 ON SNRMS N00331, N00332, N00333, N00334, N00330. REPAIR CARRIED OUT IAW SRM 53-00-51-2R REPAIR 9 REV 124.SDR AALA201809121004Floorbeam · corrodedCORROSION FOUND ON THE FLOORBEAM AT BS 1640, RBL 3. REPAIRED THE FLOORBEAM IAW SRM 53-00-51-2R-3.SDR ASAA2018100826378Floorbeam · corrodedAFT WET AREA FLOORBEAM STA. 986 HAS CORROSION ALONG TOP CAP. GROUNDED - YES. REPAIRED 986 FLOORBEAM UPPER HORZ. FLANGE IAW SRM 53-70-51-2R-4.SDR ASAA2018091026327Floorbeam · corrodedMAIN CABIN FLOORBEAM AT STA 360 LBL 8 FASTENER HOLE HAS EVIDENCE OF CORROSION. GROUNDED - YES. REPAIRED FLOORBEAM AT STA 360 LBL 8 IAW SRM 53-10-51-28-13 AND EA 900-53EA-20766 REV 00 DATED 09/25/2018. ORIGINAL THICKNESS IS .200, REMAINING IS .167 , .033 WAS RESDR ASAA2018092106257Floorbeam · corrodedAFT WET AREA FLOOR BEAM STA. 947 HAS A CORROSION PIT O/B OF RH LAV. MOUNT. GROUNDED - YES. REPAIRED FLOOR BEAM HORIZONTAL FLANGE IAW 737-800 SRM 53-70-51-2R-5.SDR SWAA2018100125650Floorbeam · crackedFLOORBEAM CRACKED AT BS 294, RBL 52. REPAIRED CHORD IAW EA & ER.SDR AALA2018091407012Floorbeam · corrodedCORROSION ON TOP OF THE FLOORBEAM, BS 986.5, RBL 4 TO RBL 6. REPAIRED THE FLOORBEAM IAW SRM 53-70-51-2R-4.SDR AALA2018091107005Floorbeam · crackedCABIN BS 540 CENTER FLOORBEAM, RBL 2 CRACKED. REPLACED THE FLOORBEAM PER AARD 51-00-05-1.SDR DALA2018090705486Floorbeam · corrodedINITIAL INSPECTION. CORROSION ON FLOORBEAM UPPER CHORD LWR SURFACE STA 345 LBL 63 AT PAX CABIN FLOOR STRUCTURE. DAMAGE ON BEAM STA 345 LBL 63 LWR SECTION WAS REPAIRED PER ER/A 571242-14 REV ORIGINAL.SDR CALA2018090701916Floorbeam · corrodedCABIN FLOOR SUPPORT BEAM IS CORRODED AT BS 986.5 11IN RIGHT OF CENTER LINE. REMOVED CORROSION AT FLOORBEAM BS 986.5 11IN RT OF CENTER LINE MAT FOUND OUT OF LIMITS MAT LOSS .032 ORG MAT .150 MAT REMAINING .118. FLAP PEEN BLENDING AREAS FAB REPAIR STRAP AND SHIMSDR FDEA201809062357Floorbeam · corrodedFLOORBEAM CORROSION RBL 64 AT BS 900-1020. REMOVED CORROSION AT ABOVE LOCATION IAW SRM 51-10-02 REV 124. MEASURED AND EVALUATED CLEANUP IAW SRM:53-40-13-1A ALLOWABLE DAMAGE 1 FIG 101 DET VII REV 124 AND FOUND OUT OF LIMITS. INSTALLED NEW CREASE BEAM BETWEEN BSSDR SWAA2018092525522Floorbeam · crackedFLIGHT COMPARTMENT FLOOR CRACKED BETWEEN BS 254 TO BS 270, BETWEEN BL 0 TO LBL 17. REPAIRED FLOOR IAW SRM.SDR ASAA2018092126195Floorbeam · corrodedMAIN CABIN STA 947.5 FLOORBEAM IS CORRODED ON THE UPPER SURFACE FROM LBL 5 TO RBL 10. GROUNDED - YES. REMOVED AND REPLACED DAMAGED REPAIR PARTS REF EA 900-53EA-20727 REV "00" DATED 09/16/2018 NO LIMITS ALLOWED.SDR F3LA2018091700435Floorbeam · corrodedMAIN CABIN FLOORBEAM TOP CAP, CORRODED 1292, FR16. REMOVED CORROSION AND EVALUATED FLOORBEAM 1292 FR16. REMOVED .0185 MATERIAL, FOUND TO BE OUT OF LIMITS IAW A320 SRM 53-11-15. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-42-11, 52-11-15 AND 51-44-11.SDR SWAA2018092425491Floorbeam · corrodedFLOORBEAM CORRODED AT BS 986, BETWEEN LBL 31 TO LBL 44. R&R CHORD PER SRM & EA.SDR F3LA2018091300430Floorbeam · corrodedFLOORBEAM -Y765 CORRODED FR 68. REMOVED AND REPLACED FLOORBEAM -Y765 FROM FS 67 TO FS 70 IAW SRM 51-72-11, 51-42-11 AND 53-00-14.SDR F3LA2018091300429Floorbeam · corrodedFLOORBEAM -Y765 CORRODED FR66. REMOVED AND REPLACED FLOORBEAM -Y765 FROM FS 64 TO FS 66 IAW SRM 51-72-11, 51-42-11 AND 53-00-14.SDR DALA2018090405411Floorbeam · corrodedDURING INSPECTION FOUND CORROSION ON FLOORBEAM STA Y= 947 AND RBL 50 PAX CABIN. FLOORBEAM STA Y= 947 AND RBL 50 PAX CABIN WAS REPAIRED PER SRM 53-70-51 REPAIR 5.SDR SWAA2018092825613Floorbeam · corrodedE&E BAY OUTER "T" CHORD CORRODED AT BS 354, LBL 6. REPAIRED T-CHORD IAW EA.SDR SWAA2018091725176Floorbeam · crackedFLOORBEAM FLANGE CRACKED AT BS 294, RBL 51. R&R ANGLE PER SRM.
Back to JASC 5315