JASC 5315
Service difficulty reports · 44,187
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR VNAA2026091133Angle · corrodedBS 280 J ANGLE IS CORRODED BETWEEN LBL 12 AND RBL 12. INSTALLED NEW SERVICEABLE BS 280 J ANGLE AT RBL 12 AND LBL12 IAW SRM 51-42-21-001-001-A01, & SRM 51-42-06-001-001-A01.SDR AALA202610015797Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR STRUCTURE, EXFOLIATION CORROSION ON THE STA. 986.5 FLOOR BEAM AT RBL-43. INSTALLED REPAIR PARTS, SUPPORT ANGLES IAW SRM 53-70-51-2R-6.SDR AALA202609304740Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: AFT CARGO GALVANIC CORROSION FOUND AROUND NUT PLATE FASTENER HOLE AT TIE DOWN FITTING LOCATED STA. 747 RBL 16. SPLICE REPAIR INSTALLED PER SRM 53-00-53-2R.SDR AALA202609309718Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR STRUCTURE, EXFOLIATION CORROSION ON THE STA 986.5 FLOORBEAM AT LBL-43. REMOVED DAMAGE AND INSTALLED STRAP, ANGLE AND FILLER IAW SRM 53-70-51-2R-6.SDR SWAA2026101975411Floorbeam · corrodedCORROSION FOUND ON FWD WET AREA FLOORBEAMS AT BS 344, RBL 9, & BS 344, RBL 17, WL 208. CORROSION EVALUATED AND REMOVED FLOORBEAM UPPER FLANGE RBL9 WL208 AND RBL17 1"X1" AREA ORIGINAL MATERIAL THICKNESS IS 0.175" LOWEST MATERIAL THICKNESS IS 0.170" CORROSIONSDR SWAA2026101988789Floorbeam · corrodedCORROSION FOUND ON AFT WET AREA FLOORBEAM AT BS 987, RBL 42, WL 208. REPAIRED THE UPPER TEE ON THE FLOORBEAM IAW SRM 53-70-51-2R-6, REPAIR 6.SDR SWAA2026100872963Floorbeam · corrodedCORROSION FOUND ON AFT WET AREA FLOORBEAM, BS 947, RBL 52, WL 208. REMOVED DAMAGED UPPER FLANGE ON THE FLOORBEAM FROM RBL 30 - RBL 58, WL 208 AND REPAIRED IAW SRM 53-70-51-2R-5, REPAIR 5, ALTERNATIVE 2.SDR SWAA2026100465784Floorbeam · corrodedCORROSION FOUND ON AFT WET AREA FLOOR STRUCTURE AT BS 987 LBL 42 WL 208 \CORROSION FOUND ON AFT WET AREA FLOOR STRUCTURE AT BS 987 LBL 42 WL 208 REMOVED CORROSION FOUND OUT OF LIMIT AND AREA WAS REPAIRED IAW SRM 53-70-51-2R-6 REPAIR 6 VERIFIED ACTION 1SDR DALA2026091605160Floorbeam · corrodedCORROSION ON FLOORBEAM AT BS 365 BTW RBL 10 -RBL 26, BTW RBL 41- RBL 60 AT PAX CABIN. FLOORBEAM AT BS 365 BTW RBL 10-RBL 26, BTW RBL 41- RBL 60 AT PAX CABIN WAS REPAIRED PER SRM 53 -00-51 (1804436)(AIRCRAFT GROUNDED)SDR HNAA2026102901061Floorbeam · corrodedLEFT CROSS FLOOR SUPPORT AT FR 18 CORRODED ON AFT SIDE. REMOVED AND REPLACED CNTR CROSS FLOOR SUPPORT AT FR 18 PER EMB 145 SRM 51-40-02-PRSDR HNAA2026102901060Floorbeam · corroded00274 CNTR CROSS FLOORBEAM AT FR 20 CORRODED. REMOVED AND REPLACED CNTR CROSS FLOORBEAM AT FR 20 PER EMB 145 SRM 51-40-02-PRSDR HNAA2026102901049Floorbeam · corrodedFLOOR SUPPORT ANGLE AT FR 18 CORRODED AT IB EDGE AROUND THE NUTPLATE HOLE. REMOVED CORROSION FROM FLOOR SUPPORT ANGLE AT FR 18 PER EMB 145 SRM 51-10-03 STEP 5.A. TYPE A, AND RESTORED SURFACE PROTECTION PER EMB 145 CPM 51-21-04, AND 51-21-05, 51-21-06SDR SWAA2026101365859Floorbeam · corrodedNUTCLIP HOLE ON CABIN FLOORBEAM BS 328, RBL 47.5 WAS CORRODED ON LOWER SURFACE. REMOVED DAMAGE IAW SRM 51-10-02. MATERIAL REMOVED 0.027. MAX MATERIAL REMAINING 0.103. DAMAGE REMOVAL IS OUT OF LIMITS IAW SRM 53-10-51-1A-1, FIG 104, DETAIL C. PERFORMED DVI OF SDR SWAA2026101306128Floorbeam · corrodedNUTCLIP HOLE ON CABIN FLOOR BEAM STA.328, RBL 39.5 HAS CORROSION ON LOWER SURFACE. REMOVED DAMAGE IAW SRM 51-10-02. REMOVED 0.009. MAX, REMAINING 0.121. DAMAGE REMOVAL IS OUT OF LIMITS IAW SRM 53-10-51-1A-1, FIG 104, DETAIL C. PERFORMED DVI OF DAMAGE REMOVASDR AALA202609306864Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: FILIFORM CORROSION ON FLOOR BEAM AROUND FASTENER HOLE AT STATION 986 FROM LBL 48 (GIRT BAR FITTING AREA). MAINTENANCE INSTALLED REPAIR PARTS AT STATION 986 FROM LBL 48 PER B737-NG SRM 53-70-51-2R-6 ALT.4.SDR DALA2026090905050Floorbeam · corrodedAFT WET AREA BS 986.5 FLOORBEAM CAP CORRODED AROUND FASTENER HOLES FROM RBL23-RBL42. REMOVED DAMAGED SECTION OF STA. 986.5 FLOORBEAM. REPAIRED UPPER T CAP SECTION BETWEEN LBL50 TO RBL 50 STA. 986.5 IAW SRM 53-70-51-2R-4 REPAIR 4 FIG 204. (1801766) AIRCRAFT WSDR JR2R20260908450Floorbeam · corrodedFLOOR BEAM LBL11 CORRODED BETWEEN FR18 THRU FR20. REPAIREDSDR SWAA2026101490831Floorbeam · corrodedCORRODED FLOORBEAM, BS 947, RBL 50, WL 208.1. PERFORMED A PERMANENT REPAIR ON THE FLOORBEAM IAW EA M-24-153-02031, REV A, & SRM 53-70-51-2R-5, REPAIRSDR IPXA2026091018202Floorbeam · corrodedMAIN DECK, BS 860 BTW BL 0 TO LBL 24.75, FLOORBEAM HAS EXFOLATION.SDR IPXA2026090912765Floorbeam · corrodedMAIN DECK STA 1500 BTW LBL 45.50 TO 54.9 FLOORBEAM HAS CORROSION AROUND SCREW HOLE. VERIFIED STEP 9 REF GMM RII 04-02. EVALUATED REWORKED AREA ON MAIN DECK STA 1500 BTW LBL 45.50 TO 54.9 FLOORBEAM UPPER FLANGE, DIMENSIONS L:1.700" W:1.300" X:0.011", ORIG. MATSDR IPXA2026101507031Nut Plate · damagedMAIN DECK STA 1681.1 AND BTW LBL 45.50 AND 54.9 RETAINER NUT HAS CORROSION BOTTOM SURFACE OF THE TOP FLANGE, INSTALLED NEW NUT PLATE RETAINER STRIP ON MAIN DECK STA 1681.1 AND BTW LBL 45.50 AND 54.9 IAW SRM 51-40-02-0G-0 PAR.4 REV 126.SDR SWIA2026090577154Floorbeam · crackedBS 22000, RBL 12, COCKPIT FLOORBEAM POSSIBLE CRACK, INSIDE PANEL 132AR, PERFORMED REPAIR TO FS220 RBL12 FLOORBEAM IAW ALL STEPS OF REO 670-53-11-2373 REV--, COMPLIED WITH TASK CARD 51-900-1002-SKY.SDR YENA2026091000786Floorbeam · not reportedDURING HEAVY MAINTEANCE, (CPCP) "REFERENCE AEROMA W.O.2026 266/1 NR 2026-432734. REMOVED AND REPLACED FLOOR BEAM -Y464.8 AT AFT GALLEY AREA IAW SRM 51-72-11, SRM 51-42-11.SDR YENA2026091000784Floor Support · not reportedDURING HEAVY MAINTEANCE, (CPCP) "REF AEROMAN N/R 2026-432640, REMOVED AND REPLACED FLOOR BEAM (Y765) LOC. BTW FR12 TO FR 24 AT FWD GALLEY AREA I.A.W SRM 51-42-11, 51-72-11-911-001, DWG D53112813 AND DWG D53110876.SDR YENA2026091000783Floorbeam · not reportedDURING HEAVY MAINTEANCE, (CPCP) "REF AEROMAN N/R 2026-432642, REMOVED AND REPLACED FLOOR BEAM (Y1292) LOC.BTW FR 12 TO FR 24 AT AFT GALLEY AREA I.A.W A320 SRM 51-42-11, A320 SRM 51-72-11-911-001, DWG D53112813 AND DWG D53110876.SDR YENA2026091000782Floorbeam · crackedDURING HEAVY MAINTEANCE, CRACK INDICATION FOUND ON THE HORIZONTAL FLOOR BEAM RADIUS BACKSIDE OF THE FRONT SPAR VERTICAL STRINGER Ñ2 FRAME 36. CRACK L= 0.320 INCH.; REF AEROMAN WO 2026 280/1 NR 2026-346060 ACCOMPLISHED PERMANENT REPAIR OF CRACK DAMAGES ON THE CSDR YENA2026091000781Floorbeam · crackedDURING HEAVY MAINTEANCE, CRACK INDICATION FOUND ON THE HORIZONTAL FLOOR BEAM RADIUS BACKSIDE OF THE FRONT SPAR VERTICAL STRINGER Ñ3 FRAME 36. CRACK L= 0.405 INCH.; REF AEROMAN WO 2026 280/1 NR 2026-346061, ACCOMPLISHED PERMANENT REPAIR OF CRACK DAMAGES ON THE SDR YENA2026091000780Floorbeam · crackedDURING HEAVY MAINTEANCE, CRACK INDICATION FOUND ON THE HORIZONTAL FLOOR BEAM RADIUS BACKSIDE OF THE FRONT SPAR VERTICAL STRINGER Ñ4 FRAME 36. CRACK L= 0.316 INCH.; (RESOLVED ON W/O: 1458309 TASKCARD: NR-00078 ) REF AEROMAN WO 2026-280/1, NR 2026 - 346062: ACCSDR YENA2026091000779Floorbeam · crackedDURING HEAVY MAINTEANCE, CRACK INDICATION FOUND ON THE HORIZONTAL FLOOR BEAM RADIUS BACKSIDE OF THE FRONT SPAR VERTICAL STRINGER Ñ5 FRAME 36. CRACK L= 0.450 INCH.; REF AEROMAN WO 2026 280/1 NR 2026-346063ACCOMPLISHED PERMANENT REPAIR OF CRACK DAMAGES ON THE CESDR YENA2026091000766Floorbeam · crackedDURING HEAVY MAINTEANCE,FRONT SPAR STRINGERS & HORIZONTAL FLOORBEAMS FR36 CRACKED. PERMANENT REPAIR (CONSIDERED A MAJOR REPAIR)SDR SWAA2026100917915Floorbeam · corrodedCORRODED FLOORBEAM, BS 947.5, RBL 50, WL 208.1. PERFORMED A PERMANENT REPAIR CATEGORY A ON THE FLOORBEAM BS 947.5 BTWN RBL 30 - 58.60 IAW SRM 53-70-51-2R-5, REPAIR 5, ALTERNATIVE 2.SDR SWAA2026100996673Floorbeam · corrodedCORRODED FLOORBEAM, BS 947, LBL 23, WL 208.1. REPAIRED UPPER TEE OF THE FLOORBEAM BS 947.5 BTWN LBL 2 - 58.60, WL 208.1. REPAIR WILL BE INSTALLED ON FAULT TTG8Q01E4RVD IAW EA 26-153-02558-WIP1, REV B, & SRM 53-70-51-2R-5, REPAIR 5.SDR SWAA2026100936251Floorbeam · corrodedCORRODED FLOORBEAM, BS 947, LBL 50, WL 208.1. PERFORMED PERMANENT REPAIR ON FLOORBEAM IAW EA 26-153-02558-WIP1, REV B, & SRM 53-70-51-2R-5, REPAIR 5.SDR VNAA202610230067Floorbeam · crackedCRACK ON PREVIOUS REPAIR AT FS 280, WL 70, LBL 12 APPROX (FWD SIDE OF CROSS BEAM) ON FLIGHT DECK FLOOR STRUCTURE. PREVIOUS REPAIR AT FS 280, WL 70, LBL 12 APPROX (FWD SIDE OF CROSS BEAM) ON FLIGHT DECK FLOOR STRUCTURE WAS REPLACED PER REO 690-53-11-1596 REV-.SDR AALA202610022038Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON CABIN FLOORBOARD SUPPORT AT STA 950 LBL 23 AND LBL 49. REMOVED AND REPLACED FLOOR SUPPORT IAW 51-00-05-1 AND BOEING DWG 147A5650.SDR AALA202610026183Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION IN MULTIPLE LOCATIONS ON FLOOR BEAM AT STATION 947.5 FROM 53LBL TO 53RBL. COMPLETED INSTALL OF ALL REPAIR PARTS. REPAIRED IAW SRM 53-70-51-2R-5 ALT 1SDR AALA202609306951Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: FILIFORM CORROSION ON FLOOR BEAM AROUND FASTENER HOLE AT STATION 986 FROM RBL 27 TO RBL 49. MAINTENANCE INSTALLED REPAIR AT STATION 986 FROM RBL 27 TO RBL 49 PER SRM 53-70-51-2R-6, ALT 4 AND EA 378897 DRAFT 4.SDR REXA2026102001949Floorbeam · corrodedCORROSION ON FLOORBEAM BS 280. FLOORBEAM BS 280 RT WAS REPLACED IAW SRM 51-10-06-001-001-A01, AND SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001-A01 AND SRM 51-42-10-001-001-A01.SDR SWAA2026100509448Floorbeam · corrodedCORROSION ON FLOORBEAM LOCATED BS 344 LBL 51 WL 208.1. REPAIRED FLOORBEAM IAW EA 26-153-02438-WIP1, EA 26-153-02438-WIP2, AND EA# 26-153-02438.SDR JR2R20260901702Floorbeam · corrodedFLOORBEAM RBL11 AT FR86 IS CORRODED.SDR SWIA2026083177281Floorbeam · corrodedFWD WET AREA HAS CORROSION ON LONGITUDINAL FLOORBEAM AT FR 17, Y-10. REMOVED AND REPLACED THE FLOORBEAM AT FR 17 AND Y-10 IAW SRM 51-40-08.SDR SWIA2026083177279Floorbeam · corrodedFWD WET AREA FLOORBEAM WAS CORRODED, FR 17, Y-10. REPAIRED FLOORBEAM IAW SRM 53-00-10,REPAIR 3P. NO FURTHER ACTION REQUIREDSDR VNAA2026083114Floorbeam · corrodedFS 280 FWD FLOORBEAM ANGLE CORRODED. REMOVED CORROSION IAW SRM 51-21-06-001-001-A01, FOUND J ANGLE TO BE OUT OF LIMITS DUE TO NO LIMITS GIVEN IN SRM. REMOVED THE J ANGLE AT BS 280 BTWN LBL 12 AND RBL 12 IAW SRM 51-42-06-001-001-A01 & SRM 51-42-21-001-001-A01SDR VNAA2026083113Floorbeam · corrodedBS. 280 LT FLOORBEAM WEB IS CORRODED AT LBL9. LOCATED, DRILLED, & INSTALLED FLOORBEAM IAW SRM-51-40-11-001-001-A01, 51-42-06-001-001-A01, 51-42-13-001-001-A01, AND 51-42-22-001-001-A01.SDR VNAA2026083110Floorbeam · corrodedFLOORBEAM ANGLE CORRODED ON AFT SIDE OF BS 280, STR 26R TO STR 26L. BLENDED CORROSION ON 3 AREAS OF THE AVI FLOORBEAM ANGLE IAW SRM 51-21-06-001-001-A01. ON FURTHER EVALUATION, FOUND CORROSION TO BE HEAVILY EXFOILIATED AND IS NEAR FULL MATERIAL LOSS AND IS SDR VNAA2026083107Floorbeam · corrodedWHILE INSTALLING AV-DEC TAPE FOUND CORROSION AROUND FASTENER HOLE ON FLOORBEAM LOCATED AT BB 333, RBL9 - RBL42. REPAIRED THE FLOORBEAM UPPER FLANGE IAW REO 670-53-21-2943 REV: -.SDR VNAA2026083106Floorbeam · corrodedWHILE INSTALLING AV-DEC TAPE FOUND 3EA SPOTS OF CORROSION ON FLOORBEAM LOCATED AT BS 333 LBL9 - LBL42. REPAIRED FLOORBEAM UPPER FLANGE IAW REO 670-53-21-2943 REV--SDR REXA2026102001972Floorbeam · corrodedCORRODED FLOORBEAM ANGLE, BS 280, LBL 9 - RBL 9. EVALUATED OUT OFF LIMITS IAW SRM 53-00-00-101-001-A01, THE FLOORBEAM WAS REPLACED SRM 51-42-06-001-001-A01, AND SRM 51-42-21-001-001-A01.SDR REXA2026102001952Floorbeam · corrodedAFTER ANGLE REMOVAL, CORROSION FOUND ON THE BS 280 FLOORBEAM. THE FLOORBEAM WAS REPLACED IAW SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001-A01, AND SRM 51-42-10-001-001-A01.SDR REXA2026102001950Floorbeam · crackedCRACKED COCKPIT FLOORBEAM, LBL 12, BS 280. THE FLOORBEAM WAS REPAIRED IAW REO 690-53-11-2255, REV--.
Back to JASC 5315