JASC 5315
Service difficulty reports · 44,187
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2026100529532Floorbeam · corrodedCORRODED FLOORBEAM, BS 947, RBL 49, WL 208.1. PERFORMED A PERMANENT REPAIR ON THE FLOORBEAM IAW SRM 53-70-51-2R-5, REPAIR 5, ALTERNATIVE 2.SDR REXA2026101601932Floorbeam · corrodedAFTER FLOORBEAM REMOVAL IAW NRC 200, THE LT FLOORBEAM AT FS280 WAS FOUND CORROSION. THE FLOORBEAM WAS REPLACED IAW SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001-A01, & SRM 51-42-22-001-001-A01.SDR JR2R20260827633Floorbeam · corrodedFWD CABIN FLOOR ATTACH ANGLE AT APPROX RBL30 AT THE AFT SIDE OF FR12 IS CORRODED. REPLACEDSDR HNAA2026092500903Floorbeam · corrodedCENTER FUSELAGE IV, THE RH CROSS BEAM GUSSET HAD CORROSION AT FR57. REMOVED AND REPLACED RT CROSS BEAM AT FR57 IAW EMB 145 SRM 51-40-02.SDR DALA2026082804879Floorbeam · corrodedWHILE WORKING CC# 5300-01163-10, FOUND CORROSION (LEVEL 2) ON THE BS 947 FLOORBEAM, LBL 50, UPPER FLANGE SURFACE, COMMON TO THE LAV D, OB ATTACH FITTING. BLENDED CORROSION ON UPPER FLANGE UPPER SURFACE OF FLOOR BEAM BS 947.5 LBL 50 WL 208. FOUND OUT OF LIMITSDR SWAA2026092882375Floorbeam · corrodedFOUND CORROSION ON FLOORBEAM AT SEVERAL LOCATIONS AT BS 328, RBL 55 TO LBL 14, WL 208. REPAIRED THE FLOORBEAM IAW SRM 53-10-51-2R-7, REPAIR-7.SDR DALA2026082604851Floorbeam · corrodedAFT FUSELAGE WET AREA - BL 0 AT BS 947 CORRODED. ACCOMPLISHED A FLOORBEAM REPAIR BS 947 UPPER TEE IAW SRM 53-70-51-2R-5. (1776249) AIRCRAFT WAS GROUNDED.SDR DALA2026082604847Floorbeam · corrodedAFT FUSELAGE WET AREA, FROM LT TO RT ALL ALONG THE FLOORBEAM TEE AT BS 986 CORRODED. ACCOMPLISHED A FLOORBEAM REPAIR FS 986 UPPER TEE IAW SRM 53-70-51-2R-4. (1776263) AIRCRAFT WAS GROUNDEDSDR REXA2026101601930Floorbeam · crackedCRACKED FLOORBEAMS (2 EA) BTWN LBL 12 - RBL 12, BS 280 & 265. THE FLOORBEAMS MANUFACTURED IAW DWG CC670-33199, REV B, & DLA 5039 & WERE REPLACED IAW SRM 51-42-21-001-001-A01, & SRM 51-42-06-001-001-A01.SDR REXA2026101601929Floorbeam · crackedCRACKED FLOORBEAMS (2 EA) BTWN LBL12 - RBL12, BS 280 & 265. THE FLOORBEAM REMOVED IAW DWG CC670-33199 REV -B & DLA 5039. THE FLOORBEAMS WERE REPLACED IAW SRM 51-42-21-001-001-A01, AND SRM 51-42-06-001-001-A01.SDR SIMA20260823001Floorbeam · corrodedRH FLOORBEAM BETWEEN FR 87-88 IS CORRODED. (MAJOR REPAIR) (LEVEL 2 CORROSION) RAR THE RT AFT GALLEY FLOORBEAM BETWEEN FR86 - FR 89 IAW SRM 51-40-08.SDR REXA2026101601899Floorbeam · corrodedCORROSION ON FLOOR SUPPORT ANGLE AND ANGLES ON FS 280 BTW RBL12 TO LBL 12 AT PASSENGER FLOOR. CORROSION ON FLOOR SUPPORT ANGLE AND ANGLES ON BS 280 BTWN RBL12 TO LBL 12 AT PASSENGER FLOOR WAS REMOVED IAW SRM 51-21-06-001-001-A01 AND FLOOR SUPPORT BS 280 BTW SDR SWAA2026092992864Floorbeam · crackedCRACKED FLOORBEAM, BS 270, BTWN BL 0 - LBL 1, WL 208.1. REPAIRED THE TRANSVERSAL BEAM IN THE FLT COMPARTMENT IAW EA 26-153-02313, EA 26-153-02313-WIP1, AND EA 26-153-02313-WIP2.SDR SWAA2026092832479Attach Angle · crackedCRACK FOUND AT BS 692.75, RBL 0.2, WL 207, UNDER 241AF FLOOR PANEL. REMOVED AND REPLACED THE FLOORBEAM ATTACH ANGLE IAW SRM 51-40-02, & DWG 273A9111, REV -.SDR VNAA202610280012Floorbeam · damagedCRACK ON BOTH ANGLE SUPPORT OF FLOORBEAM BTW FS280 RBL=10. BOTH ANGLE SUPPORT OF FLOORBEAM WERE REPAIRED IAW REO 690-53-11-1677 REV -.SDR SWAA2026092862752Floorbeam · corrodedCORROSION ON FLOORBEAM UPPER FLANGE AT NUTPLATE HOLE, BS 986.5, LBL 43, WL 208. REPAIRED THE FLOORBEAM FWD UPPER FLANGE IAW SRM 51-40-02-0G-0 AND SRM 53-70-51-2R-6, REPAIR 6.SDR SWAA2026092476359Floorbeam · corrodedCORRODED FLOORBEAM, BS 986.5, RBL 43, WL 208.1 IN THE AFT GALLEY AREA. REPAIRED THE FLOORBEAM, IAW SRM 53-70-51-2R-6, REPAIR 6.SDR VNAA202610280013Floorbeam · crackedCRACKED FLOORBEAM AT BS 280, LBL 10. THE CROSSBEAM WAS REPAIRED IAW REO 690-53-11-1677 REV -.SDR AALA202608198342Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR BEAM BETWEEN FR 68 AND FR 69 AT Y1162 LEFT - MAINTENANCE REPLACED FLOOR BEAM PER SRM 53-41-14-283-009SDR SWAA2026092973898Floorbeam · corrodedCORRODED FLOORBEAM, BS 947, RBL 49, WL 208.1. REPAIRED THE FLOORBEAM BS 947 BTWN RBL 30 - 58.6 IAW SRM 53-70-51-2R-5, REPAIR 5, ALTERNATIVE 2, & EA M-24-153-02031, REV A.SDR SWAA2026092933108Floorbeam · corrodedCORRODED FLOORBEAM, BS 947, LBL 52, AND WL 208.1 IN THE AFT GALLEY AREA. REPAIRED THE FLOORBEAM IAW SRM 53-70-51-2R-5, REPAIR 5, ALTERNATIVE 2, & EA M-24-153-02022, REV A.SDR REXA2026092101850Floorbeam · crackedCRACKED CENTER COCKPIT FLOORBEAM RBL 12 AT FS 280.00 FLOOR INTERNAL SUPPORT STRUCTURE BELOW FLIGHT COMPARTMENT CRACKED CENTER COCKPIT FLOORBEAM RBL 12 AT FS 280.00 FLOOR INTERNAL SUPPORT STRUCTURE BELOW FLIGHT COMPARTMENT WAS REPAIRED PER REO 690-53-11-2248 RSDR CALA2026081818709Floorbeam · corrodedAFT WET AREA FLOOR BEAM WITH CORROSION AREA AROUND HARD POINT FITTING BS 947 LBL 50. INSTALLED REPAIR ON STA 947.5 TRANSVERSE FLOOR BEAM UPPER CHORD IN ACCORDANCE WITH SRM 53-70-51-2R-5, AAR-MIA ESR-WI NO.: 2024492-4-15612 REV. IR, AND UNITED EC/RA 5370-01250 SDR ASAA2026081468793Floorbeam · corrodedUPON REMOVAL OF DAMAGED LAV MOUNT FITTINGS FOUND CORROSION ON BS 947 FLOORBEAM UPPER CAP AT ALL 4 LAV MOUNT FITTING LOCATIONS. GROUNDED - YES. REPAIRED FLOORBEAM 947.5 LBL-59-RBL-59 IAW SRM 53-70-51-2R-5 REPAIR 5, EA 900ER-53EA-30665.SDR MASA20260824212Floorbeam · corrodedDURING HEAVY CHECK OF CFIII, AFT WET AREA, CORRODED FLOORBEAM AT FR 86 TO FR 89 LT, RBL 11, HAS BEEN REMOVED AND REPLACED IAW SRM 51-41-01, 51-42-01, AND SRM 51-43-03. NRC# 4502709-1000-0106. REV 45, REV 50.SDR IPXA2026102375933Floorbeam · crackedMAIN DECK FLOOR, STRUCTURE AT FR 12A & Y-1959 HAS A CRACK. INSPECTED REMOVED AND REPLACED CRACKED BRACKET ON MAIN DECK FLOOR, STRUCTURE AT FR 12A & Y-1959 IAW A300-600 SRM 51-40-21. {JOB COMPLETE}SDR AALA202609090986Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: FOUND EXFOLIATION CORROSION ON FLOORBEAM STATION 294.5, LBL12. REMOVAL OF DAMAGED AREA REPAIRED WITH REINFORCED MATERIAL IAW SRM 53-10-51-2R PROCEDURE 16 ALTERNATIVE 1 AND EA 378147.SDR AALA202609012102Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM FUSELAGE STATION 344, LBL11. FOUND FILIFORM CORROSION. REPAIRED IAW SRM 53-10-51-2R PROCEDURE 9.SDR CALA2026081818707Floorbeam · corrodedPASSENGER CABIN AFT WET AREA FLOOR STRUCTURE STA 947 LBL 50 BEAM FOUND WITH CORROSION UNDERNEATH FITTING REF AAR N/R 100057376 ACCOMPLISHED FLOORBEAM REPAIR AT AFT WET AREA STA 947.5, LBL 39.7 TO LBL 56 PER SRM 53-70-51-2R-5 AND ESR -WI : 1-15605. ACCOMPLISHSDR FDEA202608131118Floorbeam · corrodedMAIN CABIN FLOORBEAM AT BS 1200 BETWEEN BL 0 TO LBL 24.75 WITH CORROSION FLOORBEAM SECTION OUT OF LIMITS AT MAIN CABIN B.S 1200 BETWEEN LBL 5 TO LBL 11 WAS REPAIRED IAW B-757 SRM 53-00-51-2R FIG 201 REPAIR 5.SDR IPXA2026100654726Floorbeam · corrodedMAIN DECK FLOOR STRUCTURE, CLS AT FR 34 BETWEEN Y0 & -Y450 HAS CORROSION INSTALLED NEW CLS ADAPTER P/N UP-B53774136200 IAW A300-600 SRM 51-40-21-001.SDR AALA202609012108Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: FOUND FILIFORM CORROSION ON FLOORBEAM BS 947 BETWEEN LBL 60 TO RBL 60. REPAIRED FLOORBEAM IAW SRM 53-70-51-2R, PROCEDURE 5 AND EA378086.SDR IPXA2026100732340Floorbeam · damagedFLOORBEAM AT FR54, BTW Y2462 AND Y1959 HAS A GOUGE AROUND SCREW HOLE ON BOTTOM SIDE. INSTALLED NEW FLOORBEAM AT FR54, BTW Y2462 AND Y1959 MDC, IAW SRM 51-40-21.SDR SWIA2026081177533Floorbeam · elongatedWHILE LOCATING AND DRILLING NEW SERVICEABLE RH CAP ANGLE PN CC670-34096-1, ELONGATED 1EA NUTPLATE HOLE IN FS 280 BEAM PN CC670-34094JP-2 AT APPROX RBL 38 C-CHECK RO 10062026COMPLIED WITH CUTOUT REPAIR TO ELONGATED NUTPLATE SCREW HOLE IN FS280 CROSSBEAM BETWESDR KCSA202608111188Floorbeam · corrodedUNDERSIDE OF FLOOR PANEL SUPPORT HAS CORROSION IN AFT BULK CARGO COMPARTMENT APPROX STA 2160 LBL 5-12SDR KCSA202608111181Floorbeam · corrodedFLIGHT DECK FLOORBEAM UPPER SURFACE CORRODED AT WEB SEAM BS 330 LBL 41 TO RBL 41.SDR SIMA20260810002Floorbeam · corrodedAFT WET AREA FLOOR STRUCTURE CORROSION ON RH BEAM AT FR 87 Y +12". (MAJOR REPAIR) (LEVEL 2 CORROSION) BLEND MEASUREMENTS OF AFT WET AREA FLOOR STRUCTURE CORROSION ON RH BEAM AT FR 87 Y +12" MEASURE L=.3" W=.2" D=.022". PART IS OUT OF LIMITS PER EMB 175 SRM 53-SDR SIMA20260810001Floorbeam · corrodedAFT WET AREA FLOOR STRUCTURE CORROSION ON LT BEAM AT FR 87 Y -12". (MAJOR REPAIR) (LEVEL 2 CORROSION) MEASUREMENTS OF AFT WET AREA FL OOR STRUCTURE CORROSION ON LH BEAM AT FR 87 Y -12" MEASURES L=.2" W=.1" D=.025" FOUND TO BE OUT OF LIMITS PER EMB 175 SRM 53-2SDR SIMA20260809006Floorbeam · corrodedFWD GALLEY CROSBEAM CORRODED BTWN RH FLOOR BEAM AND SERV DOOR CUTOUT AT FR 1. (MAJOR REPAIR). INSTALLED REPAIR PARTS (FILLER & INNER DOUBLER) ON FWD GALLEY CROSSBEAM FR 17 IAW ERJ-170 SRM 53-00-10 RE03.SDR REXA2026092101831Floorbeam · corrodedRT BS 280 BEAM HAS CORROSION UNDER UPPER SPLICE STRIP. BLENDED CORROSION ON RT BEAM UNDER UPPER SPLICE STRIP IAW SRM 51-21-06-001-001-A01 & FOUND TO HAVE 100% MATERIAL LOSS. BEAM REQUIRES REPLACEMENT. LOCATED & DRILLED NEW SERVICEABLE RT CROSSBEAM IAW SRM 5SDR REXA2026092101830Floorbeam · corrodedLT FS280 BEAM HAS CORROSION ON FWD SIDE UNDER J-ANGLE. BLENDED CORROSION ON LH FS280 BEAM UNDER J-ANGLE & UNDER UPPER SPLICE STRIP IAW SRM 51-21-06-001-001-A01 & FOUND TO HAVE 100% MATERIAL LOSS. LT 280 BEAM REQUIRES REPLACEMEMNT. INSTALLED UPPER SPLICE STRIP SDR REXA2026090401773Floorbeam · corrodedJ-ANGLE AT BS 280 IS CORRODED AROUND FASTENER HOLES. EVAL CORROSION ON FS280 J-ANGLE. UPON FURTHER INVESTIGATION FOUND DAMAGE TO BE 100% MATERIAL LOSS AT CAMLOCK RECEPTACLE. J-ANGLE REQUIRES REPLACEMENT. LOCATED AND DRILLED NEW SERVICEABLE J-ANGLE FROM FS 280 SDR IPXA2026090377567Floorbeam · crackedMAIN DECK FLOORBEAM AT RT FR79 (-Y1580.5) HAS CRACKED. INSTALLED A NEW ANGLE IN MAIN DECK FLOORBEAM AT RH FR79 (-Y1580.5). IAW SRM 51-40-21-001 AND SRM 53-18-15-001.SDR IPXA2026090377650Floorbeam · crackedMAIN DECK FLOORBEAM HAS CRACKED SUPPORT AT LT FR79 (Y1580.5). INSTALLED NEW ANGLE IN MAIN DECK FLOOR BEAM AT LH FR79 (Y1580.5). IAW SRM 51-40-21-001 AND SRM 53-18-15-001.SDR SWAA2026091004636Floorbeam · corrodedCORROSION FOUND ON TOP & UNDERSIDE AFT (WET AREA) FLOOR STRUCTURE AT LBL 2 BS 986 WL 208 {MARKED} {PICTURES UPLOADED} EVALUATED CORROSION ON BS986 LBL2 WL208 FLOOR BEAM UPPER FLANGE ORIGINAL MATERIAL THICKNESS IS 0.150" LOWEST REMAINING MATERIAL IS 0.130" DAMSDR SWAA2026091059678Floorbeam · corrodedCORROSION FOUND ON TOP & UNDERSIDE AFT (WET AREA) FLOOR STRUCTURE AT RBL 49 BS 986 WL 208 . REPAIRED FUSELAGE FLOORBEAM UPPER CHORD REPAIR AT BS 986.5 BETWEEN LHS & RHS TERMINATING ENDS AS PER EA 26-153-02137SDR SWAA2026091015537Floorbeam · corrodedCORROSION FOUND ON UNDERSIDE AFT (WET AREA) FLOOR STRUCTURE AT LBL 12 BS 986 WL 208. EVALUATED CORROSION ON BS986 LBL12 WL208 FLOOR BEAM UPPER FLANGE ORIGINAL MATERIAL THICKNESS IS 0.150" LOWEST REMAINING MATERIAL IS 0.130" DAMAGE FOUND TO BE OUT LIMITS PESDR SWAA2026091013321Floorbeam · corrodedCORROSION FOUND ON TOP & UNDERSIDE AFT (WET AREA) FLOOR STRUCTURE AT RBL 8 BS 986 WL 208. EVALUATED CORROSION ON BS986 RBL8 WL208 FLOOR BEAM UPPER FLANGE ORIGINAL MATERIAL THICKNESS IS 0.150" LOWEST REMAINING MATERIAL IS 0.090" DAMAGE FOUND TO BE OUT LIMITSSDR SWAA2026091033325Floorbeam · corrodedCORROSION FOUND ON TOP & UNDERSIDE AFT (WET AREA) FLOOR STRUCTURE AT RBL 41 BS 986 WL 208. EVALUATED CORROSION ON BS986 RBL41 WL208 FLOORBEAM UPPER FLANGE ORIGINAL MATERIAL THICKNESS IS 0.150" LOWEST REMAINING MATERIAL IS 0.110" DAMAGE FOUND TO BE OUT LIMITSDR SWAA2026091009965Floorbeam · corrodedCORROSION FOUND ON TOP & UNDERSIDE AFT (WET AREA) FLOOR STRUCTURE AT RBL 35 BS 986 WL 208 {MARKED} {PICTURES UPLOADED} EVALUATED CORROSION ON BS986 RBL35 WL208 FLOOR BEAM UPPER FLANGE ORIGINAL MATERIAL THICKNESS IS 0.150" LOWEST REMAINING MATERIAL IS 0.120" D
Back to JASC 5315