JASC 5315
Service difficulty reports · 44,220
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2014032626542Floorbeam · corrodedAFT CARGO FLOORBEAM CORRODED AT BS 867+12, RBL 8. R & R BEAM IAW SRM.SDR SWAA2014032626541Floorbeam · corrodedAFT CARGO FLOORBEAM CORRODED AT BS 867+12, RBL 3. R & R BEAM IAW SRM.SDR SWAA2014032626540Floorbeam · corrodedAFT CARGO FLOORBEAM CORRODED AT BS 867, RBL 3. R & R BEAM IAW SRM.SDR SWAA2014032626539Floorbeam · corrodedAFT CARGO FLOORBEAM CORRODED AT BS 807+18, RBL 3. R & R BEAM IAW SRM.SDR SWAA2014032626538Floorbeam · corrodedAFT CARGO FLOORBEAM CORRODED AT BS 747+7, RBL 3. R & R BEAM IAW SRM.SDR SWAA2014032626537Floorbeam · corrodedAFT CARGO FLOORBEAM CORRODED BETWEEN BS 727D+4 TO BS 727D+6, RBL 3. R & R BEAM IAW SRM.SDR SWAA2014032626536Floorbeam · corrodedAFT CARGO FLOORBEAM CORRODED BETWEEN BS 727D+4 TO BS 727D+6, LBL 3. R & R BEAM IAW SRM.SDR SWAA2014032626535Floorbeam · corrodedAFT CARGO FLOORBEAM CORRODED AT BS 727B+2.5, LBL 3. R & R BEAM IAW SRM.SDR SWAA2014032526503Floorbeam · corrodedAFT CARGO FLOORBEAM CORRODED AT BS 907, LBL 3. R & R FLOORBEAM IAW SRM.SDR SWAA2014032126313Floorbeam · corrodedAFT CARGO FLOOR BEAM CORRODED BETWEEN STATION 767+4 TO STATION 767+6, RBL 8. REPAIRED BEAM IAW EA.SDR SWAA2014032126312Floorbeam · corrodedAFT CARGO FLOOR BEAM CORRODED BETWEEN STATION 767+4 TO STATION 767+6, LBL 8. REPAIRED BEAM IAW EA.SDR SWAA2014032026295Floorbeam · corrodedAFT CARGO FLOORBEAM CORRODED AT BS 807+12, RBL 13. R & R FLOORBEAM SECTION IAW SRM.SDR DALA14017023155Floorbeam · corrodedCORROSION ON AFT PAX CABIN FLOORBEAM Y1292 FRAME 66. REPLACED FLOORBEAM IAW SRM A319 51-72-11 AND DWG D53472815.SDR DALA14017003155Floorbeam · corrodedCORROSION ON AFT PAX CABIN FLOORBEAM BETWEEN Y1292 - Y1162, FRAME 67. REPLACED FLOORBEAM IAW SRM 51-72-11 AND DWG D53472780.SDR DALA2016103108034Floorbeam · corrodedCORROSION ON FLOORBEAM -Y254 IN FWD PAX CABIN FLOOR STRUCTURE. LOC BTW FR 12 TO FR 24, REPAIR ON FLOORBEAM -Y254 IN FWD PAX CABIN FLOOR STRUCTURE LOC BTW FR 12 TO FR 24 AS PER ER/A 523452-14 REVISION 0 AND REVISION ORIGINAL.SDR SWAA2014040926950Floorbeam · crackedFLOORBEAM UPPER CHORD CRACKED AT BS 947.5, LBL 53. REPAIRED CHORD IAW EA.SDR SWIA201436870Floorbeam · crackedFS 280 FLOORBEAM AT LBL 9 INBD AND OTBD ANGLES ARE CRACKED. C-CHECK, REPLACED CRACKED INBD AND OTBD ANGLES IAW SRM.SDR SWIA201436869Floorbeam · crackedFS 280 FLOORBEAM AT RBL 9 OTBD AND INBD ANGLES ARE CRACKED. C-CHECK, REPLACED CRACKED ANGLES AT FS 280 FLOORBEAM IAW SRM.SDR SWIA201436868Floorbeam · crackedFS 280 FLOORBEAM RT LOWER RADIUS CRACKED AT RBL 11. C-CHECK, REPLACED DAMAGED FLOORBEAM RADIUS SECTION IAW REO.SDR ASOA2014040410285Floorbeam · corrodedCORROSION ON END OF FLOORBEAM BS 349 RT SIDE. MAJOR REPAIR.SDR USAA2014032700015Floorbeam · corrodedS2 CHECK, LEVEL 2 FILIFORM CORROSION ON FLOORBEAM BETWEEN FRAME 20 TO FRAME 21, Z-500 & -Y 189. REPLACED FLOORBEAM BETWEEN FRAME 20 TO FRAME 21, Z-500 & -Y 189 IAW SRM 51-72-11.SDR USAA2014032700014Floorbeam · corrodedS2 CHECK, LEVEL 2 FILIFORM CORROSION ON FLOORBEAM BETWEEN FRAME 16 TO FRAME 20, Z-500 & -Y 254. REPLACED FLOORBEAM BETWEEN FRAME 16 TO FRAME 20, Z-500 & -Y 254 IAW SRM 51-72-11 & 51-42-11.SDR USAA2014032600008Floorbeam · corrodedS2 CHECK LEVEL 2, FILIFORM CORROSION ON UPPER SURFACE OF FLOORBEAM BETWEEN FRAME 16 TO FRAME 20, Z-500 & -Y1290. REPLACED FLOORBEAM BETWEEN FRAME 16 TO FRAME 20, Z-500 & -Y1290 IAW SRM 51-72-00 & SRM 51-75-12.SDR SWIA201436849Floorbeam · crackedCOCKPIT FLOORBEAM CRACKED AT FS 274. C-CHECK, REPAIRED FLOORBEAM IAW REO.SDR SWIA201436847Floorbeam · crackedFS 280 FLOORBEAM CRACKED LT SIDE AND RT SIDE. C-CHECK, REPLACED FLOORBEAM IAW SRM.SDR USAA2014032500011Floorbeam · corrodedS2 CHECK LEVEL 2 GALVANIC CORROSION ON FLOORBEAM AT FRAME 16, Z-500 & Y495. REPLACED FLOORBEAM AT FRAME 16, Z-500 & Y495 IAW SRM 51-42-11.SDR DALA14016103220Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT AT FRAME 65+22 Y254. REPLACED FLOOR SUPPORT BETWEEN FRAMES 58-66 IAW SRM 51-72-11 AND DWG D53472000.SDR FDEA201403110489Floorbeam · corrodedFLOORBEAM AT FS 1640 RBL-LBL 65, HAS AREAS OF CORROSION ON TOP TEE. REMOVED CORROSION ON FLOORBEAM. FOUND OUT OF LIMITS, REMOVED FLOORBEAM , FABRICATED NEW FLOORBEAM. INSTALLED FLOORBEAM IAW DWG 146N5136 & SRM 51-40-02. MAJOR REPAIR.SDR CALA2014031000310Floorbeam · corrodedCORROSION UPPER SURFACE FLOOR BEAM RBL 6 - LBL 6 BS 1640. REPAIRED FLOOR BEAM AT RBL 6 - LBL 6 BS 1640 IAW ECRA NR 5300-01862.SDR FDEA201403090466Floorbeam · gougedFLOORBEAM GOUGED ON THE EXISTING REPAIR AT BS 1680 AT LBL 13 UPPER SIDE. REPAIRED IAW EA F-5310-T0306261 PART 1. REPAIR CLASSIFIED AS MAJOR.SDR FDEA201403090464Floorbeam · gougedFLOORBEAM GOUGED ON THE EXISTING REPAIR AT BS 1680 AT LBL 12 UPPER SIDE. REPAIRED IAW EA F-5310-T0306261 PART 1. REPAIR CLASSIFIED AS MAJOR.SDR FDEA201403090463Floorbeam · gougedFLOORBEAM GOUGED ON THE EXISTING REPAIR AT BS 1680 AT LBL 11 UPPER SIDE. REPAIRED IAW EA F-5310-T0306261 PART 1. REPAIR CLASSIFIED AS MAJOR.SDR FDEA201403090462Floorbeam · gougedFLOORBEAM GOUGED ON THE EXISTING REPAIR AT BS 680 AT LBL 9 UPPER SIDE. REPAIRED IAW EA F-5310-T0306261 PART 1. REPAIR CLASSIFIED AS MAJOR.SDR FDEA201403090461Floorbeam · corrodedCABIN FLOORBEAM CORRODED ON EXISTING REPAIR AT BS 1683 AT RBL 15 - 18 LOWER SIDE.SDR SWIA201436841Floorbeam · corrodedRT FLOORBEAM CORRODED BS 280. C-CHECK, REMOVED CORROSION IAW REO.SDR USAA2014032400007Floorbeam · corrodedC4 CHECK CORROSION ON FLOOR BEAM UPPER CHORD AT BS 1660, WL 208, RBL 57. REPAIRED FLOOR BEAM UPPER CHORD AT BS 1660, WL 208, RBL 57 IAW SRM 51-40-02-0G & 53-00-51-2R-8.SDR SWAA2014032126314Floorbeam · corrodedCABIN FLOOR BEAM CORRODED AT STATION 986.5, RBL 30 TO RBL 47. REPAIRED BEAM IAW EA.SDR SWAA2014031225992Floorbeam · corrodedFLOOR BEAM NUTPLATE CORRODED AT BS 344, LBL 12. R & R BEAM IAW SRM.SDR V0XD201402240042Floorbeam · corrodedFLOORBEAM AT FRAME 19A X5633 AND Y0 TO 479.0 IS CORRODED. R & R FLOORBEAM IAW SRM 51-40-02.SDR R61A201403080367Floorbeam · corrodedDURING HEAVY CHECK, LT SIDE OF THE FRAME 88 FLOORBEAM HAS CORROSION. MX R & R IAW SRM 1-43-04.SDR REXA2014031100029Floorbeam · corrodedMAINTENANCE FOUND THE UPPER FLANGE OF THE FLOOR BEAM AT FS 349 TO BE CORRODED FROM RBL 33.20 TO RBL 42.50. THE CORROSION MEASURES 4.25 INCHES X 1.00 INCH X .034 INCH DEEP. REPAIRED IAW EA CRJ253-02335 & ASSOCIATED 8110-3.SDR REXA2014031100028Floorbeam · corrodedMAINTENANCE FOUND THE UPPER FLANGE OF THE FLOOR BEAM AT FS 349 TO BE CORRODED SURROUNDING TWO NUTPLATE FASTENER HOLES BETWEEN RBL 9.00 & LBL 45.00. REPAIRED IAW EA CRJ253-02333 & ASSOCIATED 8110-3.SDR DALA14015353155Floorbeam · corrodedCORROSION ON FLOORBEAM FRAME 16, LEVEL Y765. REWORKED IAW SRM 51-74-00. FOUND WITHIN LIMITS IAW SRM 53-11-15, PARA 4.B, FIG 106 AND APPLIED PROTECTIVE TREATMENT IAW SRM 51-21-11 AND SRM 51-23-11.SDR V0XD201403080001Floorbeam · corrodedFLOOR BEAM AT FS 1036, LBL 27 CORRODED. CUT OUT CORRODED SECTION OF FLOOR BEAM. INSTALLED NEW PART IAW REO 670-53-00-029 REV A, CRJ 700 AMM 20-70-00, CRJ 700, SRM 51-24-36, 51-40-11, 51-21-11, 51-25-06 & 51-25-16.SDR SWAA2014040326791Floorbeam · crackedCROSSBEAM LOWER FLANGE CRACKED AT BS 947.5, LBL 55. REPAIRED FLANGE IAW EA.SDR 7AHR2014030782487Floorbeam · corrodedCORROSION ON UPPER FLANGE CABIN FLOORBEAM, BS 807 BETWEEN LBL 45 AND RBL 45. INSTALLED REPAIR IAW DWG 53-14034-1 WITH 8110-3 APPROVAL.SDR ASAA2014030607367Floorbeam · corrodedAFT ENTRY DOOR AREA, FLOORBEAM IS CORRODED, BS 986.5, RBL 48, WL 200. ACFT GROUNDED. REMOVED CORROSION IAW SRM 53-70-51. FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51. REPAIRED FLOORBEAM IAW SRM 53-70-51-2R-4.SDR ASAA2014030607366Floorbeam · corrodedFLOOR STRUCTURE WET AREAS, FLOORBEAM IS CORRODED INBD OF AFT SERVICE DOOR. BS 986.5, LBL 47, WL 200. ACFT GROUNDED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51. REPAIRED FLOORBEAM IAW SRM 53-70-51-2R-4.SDR SWIA201436704Floorbeam · crackedFS 484, BELOW FLOOR, LT OTBD AND INBD ATTACH ANGLES FOR CONTROL CABLE PULLEY STRUCTURE AT LBL 27 AND LBL 35, BOTH ANGLES ARE CRACKED IN THE UPPER RADIUS AND CRACKED AROUND FAST. C-CHECK, REPLACED INBD AND OTBD ATTATCH ANGLES AT FS 484.0, LBL 27 AND 35, PN 60SDR SWIA201436703Floorbeam · crackedBS 484, RT BELOW FLOOR, RT OTBD AND INBD ATTACH ANGLES FOR CONTROL CABLE PULLIES STRUCTURE AT RBL 27 AND RBL 35 BOTH ANGLES ARE CRACKED IN UPPER RADIUS AND AROUND FAST. C-CHECK, R & R OTBD & INBD ANGLES AT FS484, RT RBL27 & RBL35 IAW SRM AND REO.
Back to JASC 5315