JASC 5315
Service difficulty reports · 44,220
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201108163311Floorbeam · corrodedCORROSION TOP TEE FLOORBEAM BS 560, LBL 12. CUTOUT DAMAGE AREA, FABRICATED REPAIR AND INSTALLED IAW SRM 53-10-8, FOG 8 AND SRM 51-30-2.SDR CALA2011081500541Floorbeam · corrodedFLOORBEAM UPPER TEE CORRODED AT BS 325 LBL 27-55. CORROSION REMOVED OUT IAW SRM 53-00 -51 1 FIG 101. REPAIRED AS PER SRM 53-00-51 REPAIR 1 FIG 201.SDR SWAA115907Floorbeam · corrodedDURING SCHEDULED 12Y CHECK, FOUND FLOORBEAM CORRODED AT BS 328, BETWEEN RBL 48 TO RBL 55. REPAIRED BEAM PER SRM.SDR A6WA201140854Floorbeam · crackedFLOORBEAM CRACKED AT FS484.0, LBL27.0. R & R FLOORBEAM TEE IAW REO 601R-53-41-059.SDR USAA2011083100006Floorbeam · corrodedS2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR66 TO FR68, S23L. REPLACED FLOORBEAM BETWEEN FR66 TO FR68, S23L IAW A319 SRM 51-42-11.SDR USAA2011083100005Floorbeam · corrodedS2 CHECK - LEVEL 2 FILIFORM CORROSION ON FLOORBEAM BETWEEN FR68 TO FR69, S23L. REPLACED FLOORBEAM BETWEEN FR68 TO FR69, S23L IAW A319 SRM 51-42-11.SDR USAA2011083100004Floorbeam · corrodedS2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM 4 INCHES FORWARD OF FR69, -Y1292. REPLACED FLOORBEAM 4 INCHES FORWARD OF FR69, -Y1292 IAW A319 SRM 51-72-11.SDR USAA2011083100003Floorbeam · corrodedS2 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR66, -Y1292. REPLACED FLOORBEAM AT FR66, -Y1292 IAW A319 SRM 51-72-11.SDR FDEA201108153318Floorbeam · corrodedCORROSION ON TOP FLOORBEAM TEE, BS 720D, BL 0 TO RBL 12. CUTOUT DAMAGE AREA, FABRICATED REPAIR & INSTALLED REPAIR IAW SRM 53-10-8, FIG 3 & SRM 51-30-2.SDR SWAA115865Floorbeam · corrodedDURING SCHEDULED 22Y CHECK, FOUND FLOOR BEAM CORRODED AT BS 967, LBL 5. REPAIRED BEAM IAW SRM.SDR SWAA115844Floorbeam · crackedDURING SCHEDULED 24Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 663.75, RBL 24.5. REPAIRED CHORD IAW EA.SDR USAA2011081600012Floorbeam · corrodedC11, SY6 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR66 TO FR68, Y1292. REPLACED FLOORBEAM BETWEEN FR66 TO FR68, Y1292 IAW A319 SRM 51-72-11 AND AIRBUS DRAWING D53472780.SDR USAA2011081600011Floorbeam · corrodedC11, SY6 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR16 TO FR24, Y-254. REPLACED FLOORBEAM BETWEEN FR16 TO FR24, Y-254 IAW A319 SRM 51-72-11.SDR USAA2011081600010Floorbeam · corrodedC11, SY6 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR20 TO FR24, -Y254. REPLACED FLOORBEAM BETWEEN FR20 TO FR24, -Y254 IAW A319 SRM 51-72-11.SDR USAA2011081600009Floorbeam · corrodedC11, SY6 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR16 TO FR20, Y1292. REPLACED FLOORBEAM BETWEEN FR16 TO FR20, Y1292 IAW A319 SRM 51-72-11, 51-42-11 AND AIRBUS DRAWING D53112812.SDR USAA2011081600008Floorbeam · corrodedC11, SY6 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM AT FR16, -Y765. REPLACED FLOORBEAM AT FR16, -Y765 IAW A319 SRM 51-43-00.SDR SWAA115822Floorbeam · crackedDURING SCHEDULED 24Y CHECK, FOUND FLOORBEAM CHORD CRACKED AT BS 663+3, RBL 24.5. REPAIRED CHORD IAW EA.SDR CALA2011081500540Floorbeam · corrodedCABIN FLOORBEAM UPPER CHORD CORRODED AT BS 303 LBL 11-53. CABIN FLOOR UPPER CHORD CORROSION REMOVED AS PER SRM 51-10-02 AND BLENDED AREA D:0.042"X W:2"X L:3" (ORG 0.090") OUT OF SRM 53-00-51 ALLOWABLE DAMAGE 1 FIG 101 LIMIT AND CORRODED UPPER CHORD REPAIRED ASDR SWIA201127225Floorbeam · cracked(C-CHECK) LEFT FS 274 FLOORBEAM IS BUCKLED AND RIGHT FS 274 FLOORBEAM IS CRACKED. REPLACED BOTH LEFT AND RIGHT FS 274 FLOORBEAMS PER SRM.SDR CALA2011081500538Floorbeam · corrodedCORROSION ON TOP OF FLOORBEAM STA 1640 RBL 3. REPAIRED FLOORBEAM AT STA 1640 RBL 3 PER ECRA 5321-01102.SDR FOTR2011081201226Floorbeam · misrepairedFLOORBEAM, BS 1280, BL 0 MISREPAIRED. REPAIRED ON FASI WO 21119, NR 01226.SDR FDEA201108123253Floorbeam · corrodedCORROSION TOP FLOORBEAM TEE, BS 380, LBL 25 - 45. CUTOUT DAMAGE AREA, FABRICATED FLOORBEAM REPAIR & INSTALLED REPAIR IAW SRM 53-10-8, FIG 8 & SRM 51-30-2.SDR FDEA201108123251Floorbeam · bentAFT CARGO FLOORBEAM AT FRAME 63 IS BENT, BS 4150. FABRICATED CHANNELS FOR FLOORBEAM REPAIR IAW SRM 53-10-15, FIG 207. REPAIR ACCOMPLISHED ON SNRM N00007 AND EA 6-5310-152428.SDR FDEA201108123232Floorbeam · corrodedCENTER CARGO COMPARTMENT ALONG STA 1841, BETWEEN LONGERON 45L AND LONGERON 48R, FLOORBEAM WEB AREAS FOUND SURFACE CORROSION. CORROSION REMOVED IAW SRM 51-21-01, REV 47. FOUND EXCEEDED LIMIT IAW SRM 53-00-00, FIG 202, REV 47. R & R IAW SRM 51-35-01, REV 47SDR FDEA201108123231Floorbeam · corrodedAFT CARGO FLOORBEAM AT STA 1841 X=58.0 TO X=-58.0 FOUND CORROSION AT SEVERAL ANCHOR NUTS AREA. CORROSION REMOVED AND FOUND EXCEEDED LIMIT IAW SRM 53-00-00, FIG 202, REV 47 AND NEW UPPER TEE INSTALLED IAW SRM 51-35-01, REV 47. REPAIR CLASSIFIED AS MAJOR IAW GMSDR USAA2011083100014Floorbeam · corrodedS2 CHECK - LEVEL 2 SURFACE CORROSION ON FLOORBEAM AT FR66, Y1732. REPLACED FLOORBEAM AT FR66, Y1732 IAW A319 SRM-51-72-11 & AIRBUS DRAWING D53474250.SDR USAA2011083100007Floorbeam · corrodedS2 CHECK - LEVEL 2 INTERGRANULAR CORROSION ON FLOORBEAM BETWEEN FR16 TO FR20, Y1292. REPLACED FLOORBEAM BETWEEN FR16 TO FR20, Y1292 IAW A319 SRM 51-72-11.SDR DALA1148899015Floorbeam · corrodedAFT LAV FLOORBEAM STA 1322 LBL 28 LBL 20 EVIDENCE OF CORROSION, FABRICATED -9 AND -11 FILLER IAW SRM MD80 53-05 IFG 79A AND SRM 51-10-4.N FABRICATED LOCATED AND DRILLED FLOORBEAM REPAIR ANGLE STA 1322 LBL 36-53 IAW MD80 SRM 53-05 FIG 79A. INSTALLED FILLER REPSDR UALA2011081504263Floorbeam · corrodedFLOORBEAM AT BS 1681, RBL 37 - RBL 42 CORRODED. REMOVED DAMAGED TEE ENTIRE LENGTH BETWEEN RBL 60 TO LBL 60. FABRICATED A REPLACEMENT TEE ANGLE AND FILLERS AND ASSOCIATED REPAIR PARTS PER REO G 13868, REV. C AND INSTALLEDSDR SWIA201127207Floorbeam · corroded(C-CHECK) FS 280 FLOORBEAM CORRODED. REPLACED PER REO.SDR ASOA201101509Crossbeam · corrodedBS 280 CROSSBEAM CORRODED. BLENDED .002 IN OUT .063 THICKNESS. FOUND DAMAGE TO BE WITHIN LIMITS IAW SRM 51-21-06-001-001-A01.SDR ASOA201101504Crossbeam · corrodedBS 280 CROSSBEAM IS CORRODED. REMOVED AND REPLACED CROSSBEAM IAW REO 670-53-11-047.SDR DALA1147630672Floorbeam · corrodedMAIN CABIN FLOORBEAM UPPER SURFACE HAS CORROSION SAT 1640 LBL 58 TO RBL 58. ACCOMPLISHED PERM REPAIR PER ERA 494611-14 REV O.SDR USAA2011082900008Attach Angle · crackedQ3 CHECK - CRACK ON FLOORBEAM VERTICAL ATTACH ANGLE AT BS 328, RBL 32. REPLACED FLOORBEAM VERTICAL ATTACH ANGLE AT BS 328, RBL 32 IAW EA 103286.SDR USAA2011082300013Floorbeam · corroded2S CHECK - LEVEL 2 GALVANIC CORROSION ON LONGITUDINAL BEAM BETWEEN FR64 TO FR66, Y1292. REPLACED LONGITUDINAL BEAM BETWEEN FR64 TO FR66, Y1292 IAW A320 SRM 53-00-14 FIG 102 & 51-42-11.SDR USAA2011082300012Floorbeam · corroded2S CHECK - LEVEL 2 GALVANIC CORROSION ON LONGITUDINAL BEAM BETWEEN FR68 TO FR69, Y1162. REPLACED LONGITUDINAL BEAM BETWEEN FR68 TO FR69, Y1162 IAW A320 SRM 53-00-14 FIG 102 & 51-42-11.SDR USAA2011082300011Floorbeam · corroded2S CHECK - LEVEL 2 GALVANIC CORROSION ON LONGITUDINAL BEAM BETWEEN FR66 TO FR68, Y1162. REPLACED LONGITUDINAL BEAM BETWEEN FR66 TO FR68, Y1162 IAW A320 SRM 53-00-14 FIG 102 & 51-42-11.SDR USAA2011082300010Floorbeam · corroded2S CHECK - LEVEL 2 GALVANIC CORROSION ON LONGITUDINAL BEAM BETWEEN FR68 TO FR70, Y160. REPLACED LONGITUDINAL BEAM BETWEEN FR68 TO FR70, Y160 IAW A320 SRM 53-11-14 FIG 104 & 51-42-11.SDR UALA2011081204238Floorbeam · brokenMAIN CABIN FLOORBEAM AT BS 500L IS BROKEN OFF FROM LBL 45 TO THE END OF THE BEAM. REMOVED DAMAGED SECTION OF FLOORBEAM AND FABRICATED A REPLACEMENT FLOORBEAM SEGMENT, REPAIR CHANNELS, REPAIR ANGLES, AND DOUBLERS AND INSTALLED PER REO G1385 9, REV.SDR IPXA11568694Floorbeam · damagedINSPECTION TYPE:C3, REPAIRED THE BS 480, FLOORBEAM BETWEEN LBL 45-62 IAW ENGINEERING. REPAIRED IAW ATS ER 11-03951.SDR SWAA115787Floorbeam · crackedDURING SCHEDULED 22Y CHECK, FOUND LONGITUDINAL FLOORBEAM UPPER CHORD CRACKED AT BS 727B, RBL 24.8. REPAIRED CHORD IAW EA.SDR EIAA2011107Floorbeam · damagedDT EVALUATION UPPER DECK FLOORBEAM UPPER CHORD AFT FLANGE HAS DOUBLE HOLE AT BS 540 LBL 33. FLOORBEAM REPAIR PER B747 SRM 53-10-07, FIGURE 21.SDR UALA2011081004189Floorbeam · corrodedMAIN CABIN FLOORBEAM T-CAP UPPER SURFACE CORRODED AT BS 322, RBL 41-50. MAJOR REPAIR ACCOMPLISHED. REMOVED CORROSION & FOUND TO BE OUT OF LIMITS PER SRM. BLENDED DAMAGED AREA AND FABRICATED REPAIR ANGLES AND FILLER AND INSTALLED PER TIMCO REO G13891, REV B SDR AALA20110810TUL11Floorbeam · damagedHUMP IN PREVIOUS REPAIRS ON FLOORBEAM. PERFORM TEE CAP REPAIR PER EA B757-53-018541.SDR USAA2011081600007Floorbeam · corrodedC11, SY6 CHECK - LEVEL 2 EXFOLIATION CORROSION ON FLOORBEAM BETWEEN FR16 TO FR21, Y254. REPLACED FLOORBEAM BETWEEN FR16 TO FR21, Y254 IAW A319 SRM 51-72-11.SDR SWAA115746Floorbeam · crackedDURING SCHEDULED 24Y CHECK, FOUND FLOORBEAM WEB CRACKED BETWEEN BS 713 TO BS 708, RBL 0. REPAIRED WEB IAW SI.SDR FOTR2011080901225Floorbeam · misrepairedFLOORBEAM BS 700, BL 0 MISREPAIRED. REPAIRED ON FASI WO 21119, NR 01225.SDR FDEA201108093149Floorbeam · corrodedCORRODED FLOORBEAM TOP TEE, BL 0 TO RBL 25, STA 560. CUTOUT DAMAGE AREA, FABRICATED NEW REPAIR AND INSTALLED NEW REPAIR IAW SRM 53-10-8 FIG 3 & SRM 51-30-2.SDR USAA2011082300015Floorbeam · corroded2S CHECK - LEVEL 2 GALVANIC CORROSION ON LONGITUDINAL BEAM BETWEEN FR64 TO FR66, -Y765. REPLACED LONGITUDINAL BEAM BETWEEN FR64 TO FR66, -Y765 IAW A320 SRM 53-00-14 FIG 102 & 51-42-11.SDR USAA2011082300014Floorbeam · corroded2S CHECK - LEVEL 2 GALVANIC CORROSION ON LONGITUDINAL BEAM AT FR66, Y512. REPLACED LONGITUDINAL BEAM AT FR66, Y512 IAW A320 SRM 53-00-14 FIG 102 & 51-42-11.
Back to JASC 5315